DC Input Alarm Trips
|
|
| Click
here to download DC Input pdf |
| Model
| Input
| Output
| Power |
API
1000 G
DC Input DPDT Alarm
|
| DC
Voltage or Current
Specify Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1020 G
DC Input Dual SPDT
Alarms
| DC
Voltage or Current
Specify Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1005 G
4-20 mA
Input DPDT Alarm
|
| 4-20
mA
18V Loop Supply
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1025 G
4-20 mA
Input Dual SPDT Alarms
| 4-20
mA
18V Loop Supply
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1040 G
DC Input SPDT Alarm +
Transmitter
|
| DC
Voltage or Current
Specify Range
18V Loop Supply
| 1
SPDT Contact Set
Field Adjustable Hi Alarm
Non-Isolated DC Voltage or
Current Transmitter
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1080 G
Field Settable
DC Input DPDT Alarm
1080
G Ranges
1080
G Help
|
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
| 1
DPDT Contact Set
Field Adjustable
Selectable Alarm Action
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1080 DIN
Field Settable
DC Input DPDT Alarm
|
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| 1
DPDT Contact Set
Field Adjustable
Selectable Alarm Action
| 80-265
VAC
48-300 VDC |
API
1090 G
Field Settable DC Input
Dual SPDT Alarms
1090
G Ranges
1090
G Help
|
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
| 2
SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1090 DIN
Field Settable DC Input
Dual SPDT Alarms
|
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| 2
SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
| 80-265
VAC
48-300 VDC |
API
1090 DD
Field Settable DC Input
Dual SPDT Alarms
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| 2
SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
| 9-30
VDC |
|
DC - DC Transmitters
|
|
| Click
here to download DC Input pdf |
| Model
| Input
| Output
| Power |
API
4010 G
DC-DC Transmitter,
Non-Isolated
|
| DC
Voltage or Current
Specify Range
18V Loop Supply
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4050 G
DC-DC Transmitter,
Non-Isolated
Narrow Input Span
| DC
Voltage or Current
Specify Range
Narrow Input Span
18V Loop Supply
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4300 G
DC-DC Transmitter, Isolated
|
| DC
Voltage or Current
Factory Set Range
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4310 G
DC-DC Transmitter, Isolated
Narrow Input Span
| DC
Voltage or Current
Specify Range
Narrow Input Range
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4380 G
DC-DC
Transmitter, Isolated
Field Rangeable
4380
G Ranges
4380
G Help
|
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully
Isolated
C Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4380 GHV3
Hi Voltage DC-DC Transmitter,
Isolated
Field Rangeable
4380
GHV3 Ranges
| DC
Voltage or Current
Field Selectable Ranges
High Voltage Input to
±200 VDC
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4380 DIN
DC-DC
Transmitter, Isolated
Field Rangeable
4380
DIN Help
|
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 80-265
VAC
48-300 VDC |
API
4380 DD
DC-DC Transmitter, Isolated
Field Rangeable
4380 DIN Help
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 9-30
VDC |
API
4385 G
DC-DC Transmitter, Isolated
Field Rangeable
4385 G Ranges
|
| DC
Voltage or Current
Field Selectable Ranges
True Offset
Non-Interacting Controls
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
DPI
HV-DC
Hi
Voltage DC-DC Transmitter,
Isolated
Field Rangeable
DPI
HV-DC Ranges
|
| High
Voltage DC
0-100VDC to 0-1200VDC
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
API
4390
2 Channel DC-DC Transmitter,
Isolated
|
| DC
Volts or mA
2 Independent Channels
| Fully
Isolated
DC Voltage or Current
2 Independent Channels
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API
4391
2 Channel DC-DC Transmitter,
Isolated, Bipolar Output
|
| DC
Volts or mA
2 Independent Channels
| Fully
Isolated
Bipolar ±5 Volts or ±10 Volts
2 Independent Channels
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API
4392
2 Channel DC-DC Transmitter,
Isolated, Bipolar Input & Output
|
| Bipolar
±DC Volts or ±mA
2 Independent Channels
| Fully
Isolated
Bipolar ±DC Volts or mA
2 Independent Channels
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API
4393
IsoSplitter
™
DC-DC
Signal Splitter,
Isolated
|
| One
DC Voltage or Current
| Fully
Isolated
Two Independent
DC Voltage or
Current Channels
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API
4393 L1
IsoSplitter
™
DC-DC Signal Splitter,
Isolated
Sourced Input,
Source or Sink Outputs
|
| One
4-20 mA
18V Loop Power Supply
| Fully
Isolated
Two Independent
4-20 mA Channels
Source or Sink Outputs
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
|
Loop-Powered
Isolators
|
|
| Click
here to download DC Input pdf |
| Model
| Input
| Output
| Power |
API
LPI-1
Loop-Powered Isolator
|
| 4-20
mA
| Fully
Isolated
4-20 mA
| Loop
Powered |
API
LPI-2
Dual Channel
Loop-Powered Isolator
| Two
4-20 mA
| Fully
Isolated
Two 4-20 mA
| Loop
Powered |
DPI-2
Dual Channel
Loop-Powered Isolator
|
| Two
4-20 mA
| Fully
Isolated
Two 4-20 mA
| Loop
Powered |
|
Loop
Power Supplies
|
|
| |
| Model
| Input
| Output
| Power |
API
9046
Power Supplies
|

|
115
VAC Std.
Opt. 230 VAC
|
Isolated
Regulated DC Voltage
Specify 5 to 32 VDC
|
115
VAC Std.
Opt. 230 VAC
|
API
9046 CH
Bipolar Power Supplies
|
115
VAC Std.
Opt. 230 VAC
|
Isolated
Regulated DC Voltage
Bipolar (±) Output VDC
Specify ±5 to ±15 VDC
|
115
VAC Std.
Opt. 230 VAC
|
|
Thermocouple Input
|
|
| Click
here to download Temperature Input pdf |
| Model
| Input
| Output
| Power |
API
1200 G
T/C Input DPDT
Alarm
|
| J,
K, T, E Thermocouple
Specify Type & Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1220 G
T/C Input Dual SPDT
Alarms
| J,
K, T, E Thermocouple
Specify Type & Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Types
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4000 G
T/C or RTD Input Transmitter,
Isolated
Field Rangeable
4000 G Ranges
4000
G Help
|
| J,
K, T, E, R, S Thermocouple
Most RTDs &
Resistance Elements
Field Selectable Type & Range
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API
4100 G
T/C Input Transmitter,
Non-Isolated, Non-Linearized
|
| J,
K, T, E Thermocouple
Specify Type & Range
|
DC
Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API
4130 GL
T/C Input Transmitter,
Isolated, Linearized
| J,
K, T, E Thermocouple
Specify Type & Range
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
|
RTD
Input
|
|
| Click
here to download Temperature Input pdf |
| Model
| Input
| Output
| Power |
API
1400 G
RTD Input DPDT
Alarm
|
| 10
Ω to 2000 Ω RTDs
Factory Set Type & Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1420 G
RTD Input Dual SPDT
Alarms
| 10
Ω to 2000 Ω RTDs
Specify Type & Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Types
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4000 G
T/C or RTD Input Transmitter,
Isolated
Field Rangeable
4000
G Ranges
4000
G Help
|
| Most
RTDs &
Resistance Elements
J, K, T, E, R, S Thermocouple
Field Selectable Type & Range
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4001 G
RTD Input Transmitter,
Non-Isolated,
Non-Linearized
|
| 10
Ω to 2000 Ω RTDs
Specify Type & Range
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4001 GL
RTD Input Transmitter,
Isolated,
Linearized
| 10
Ω to 2000 Ω RTDs
Specify Type & Range
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4001 G SA-B
Differential 2 RTD Input
Transmitter,
Non-Isolated,
Non-Linearized
|
| Two
100 Ω 0.00385 RTDs
For Differential Temperature
Factory Set,
Can Be Field Calibrated
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
Frequency
Modules
|
Click
at Right for Details:
|
| Click
here to download Frequency pdf |
| Model
| Input
| Output
| Power |
API
1700 G
Frequency Input DPDT Alarm
|
| 10
Hz to 20 KHz
Specify Input Span
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1720 G
Frequency Input Dual SPDT
Alarms
| 10
Hz to 20 KHz
Specify Input Span
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7010 G
Frequency to
DC Transmitter, Isolated
|
| 10
Hz to 20 KHz
Specify Input Span
|
Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7500 G
DC to Frequency
Transmitter, Isolated
7500
G Ranges
7500
G Help
|
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully
Isolated
0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7500 G SS
DC to Low Frequency
Transmitter, Isolated
7500 G SS Ranges
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully
Isolated
0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7580 G
Frequency to
DC Transmitter, Isolated
Field Rangeable
7580
G Ranges
7580
G Help
|
| 100
Hz to 30 KHz
Field Selectable Ranges
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
AC
Input
|
|
| Click
here to download AC Input pdf |
| Model
| Input
| Output
| Power |
API
1600 G
AC
Input DPDT Alarm
|
| AC
Voltage or Current
Specify Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1620 G
AC
Input Dual SPDT Alarms
| AC
Voltage or Current
Specify Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
6010 G
AC
to DC Transmitter, Isolated
|
| AC
Voltage or Current
Specify Range
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
6010 G 5A &
API 6010 G 20A
C to DC Transmitters, Isolated
High Current
|
| AC
Current (up to 20 A)
Specify Range
Socket & Shunt Included
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
6380 G
AC
to DC Transmitter, Isolated
Field Rangeable
6380 G Ranges
6380
G Help
|
| AC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API
6380 G S
True RMS AC
to DC Transmitter,
Isolated
Field Rangeable
6380 G S Ranges
6380
G S Help
| True
RMS
AC Voltage or Current
Field Selectable Ranges
18V Loop Supply
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
|
Potentiometer
|
|
| Click
here to download Potentiometer Input pdf |
| Model
| Input
| Output
| Power |
API
1800 G
Potentiometer Input DPDT Alarm
|
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1820 G
Potentiometer Input
Dual SPDT Alarms
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4003 G
Potentiometer to DC
Transmitter,
Non-Isolated
|
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4003 G I
Potentiometer to DC
Transmitter,
Isolated
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4008 G
Potentiometer to DC
Transmitter,
Isolated
Field Rangeable
|
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
Strain
Gauge,
Bridge, Load Cell Input
|
|
| Click
here to download Strain Gauge Input pdf |
| Model
| Input
| Output
| Power |
API
1500 G
Strain
Gauge Input DPDT Alarm
|
| Strain
Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1520 G
Strain
Gauge Input Dual
SPDT Alarms
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4051 G
Single Strain Gauge
to
DC Transmitter,
Non-Isolated
|
| Strain
Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4058 G
1-4 Strain Gauge to
DC Transmitter,
Non-Isolated
4058
G Ranges
4058
G Help
|
| 1
to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
DC
Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4059 G
1-4 Strain Gauge to
DC Transmitter, Isolated
4059
G Help
4059
G Ranges
|
| 1
to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
API
4059 DIN
1-4 Strain Gauge to
DC Transmitter, Isolated
4059
DIN Ranges
|
| 1
to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
SUM 000
Strain
Gauge Summing Board
API
SUM 025
Summing
Board with API 4059
API
SUM 100
Summing
Board w. NEMA 4X Box
API
SUM 125
Summing
Board, API 4059, NEMA 4X Box
|
| Summing
Assembly Board
1 to 4 Strain Gauges,
Bridges, or Load Cells
Individually Adjustable
Excitation & Signal Trim
Optional SS Housing
|
DC
Voltage or Current
Use with 4058 G or
4059 G
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
Valve
Position,
Math & P-I Converters
|
|
| Click
here to download Valve/Math pdf |
| Model
| Input
| Output
| Power |
API
3200 G
Valve
Positioner/Actuator
|
| DC
Voltage or Current
Specify Range
100 Ω to 100 kΩ
Feedback Pot
| Valve
/ Actuator
Positioner / Controller
2 SPST Relays
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4400 G
(A+B+C+D)
/ 4
API 4401 G
(A+B+C)
/ 3
API 4402 G
(A+B)
/ 2
API 4403 G
(A+B+C–D)
/ 3
API 4404 G
(A+B–C–D)
/ 4
API 4405 G
(A–B–C–D)
API 4406 G
(A+B–C)
/ 2
API 4407 G
(A–B–C)
API 4408 G
(A–B)
|
| Up
to 4 DC Voltage or
Current Inputs
Specify Ranges
| Addition,
Subtraction,
Averaging Versions
Fully Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4440 G
DC
to DC Transmitter,
Square Root Extraction
|
| DC
Voltage or Current
Specify Range
18V Loop Supply
| Square
Root Extraction
Full Isolated
DC Voltage or Current
Square Root of Input
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
DPG1000L3-15PSIG
Pressure
to Current Converter
|
| 3.00
to 15.00 psig
| 4-20
mA
| Loop
Powered |
F4L3-15PSIG
Pressure
to Current Converter,
NEMA 4X
|
| 3.00
to 15.00 psig
| 4-20
mA
| Loop
Powered |
|
Module
Accessories
|
|
| Click
here to download Accessories pdf |
| Sockets
& Housings
|

| 8-Pin,
11-Pin Sockets
8-Pin, 11-Pin Finger-Safe Sockets
DIN Rail
Module Housings |
|
Current
|
|
| Click
here to download current Sensor pdf |
| Model
| Input
| Output
| Power |
CTX-ACR
AC Current Transmitters
|
| True
RMS
0-2 Amps to
0-200 Amps AC
| Isolated
Output
4-20 mA
| Loop
Powered |
CTX-ACR-3S
& 4S
High AC Current Transmitters
|
| True
RMS
0-375 Amps to
0-2000 Amps AC
| Isolated
Output
4-20 mA
| Loop
Powered |
CTX-DC
DC Current Transmitters
|
| 0-50
Amps to
0-400 Amps DC
| Isolated
Output
4-20 mA
| 20-50
VDC or
22-38 VAC |
CS-AC
AC
Current Switches
|
| 1.5-150
Amps AC
| 0.15
Amp SSR
LED Status Indicator
NC or NO Models
| Self
Powered |
CS-DC
DC
Current Switches
|
| 5-100
Amps DC
| 0.3
Amp SSR or
5 Amp Relay
LED Status Indicator
| 20-28
VAC/VDC or
12 VAC/VDC
LED Power Indicator |
2RL/5RL/7RL/8RL
AC
Current Transformers
|
| 600
VAC
50:5 to 1600:5 Ratios
| Proportional
to Input
| Self
Powered |
|
OEM Products
|
| Custom
Electronics
| Custom
Signal Conditioners, Signal Converters,
Instrumentation
Call
us at 800-783-6664 or
email Sales
Department |