DC Input Alarm Trips Loop Power Supplies  Frequency Modules

Strain Gauge,
 Bridge, Load Cell Input
 

 DC Transmitters Thermocouple Input

AC Input

Valve Position,
 Math & P-I Converters

Loop-Powered Isolators RTD Input Potentiometer Input 

Current Sensors 

  DC Input Alarm Trips

 

Click here to download DC Input pdf
Model Input Output Power
API 1000 G
DC Input DPDT Alarm
DC Voltage or Current
Specify Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1020 G
DC Input Dual SPDT Alarms
DC Voltage or Current
Specify Range
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1005 G
4-20 mA Input DPDT Alarm
4-20 mA
18V Loop Supply
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1025 G
4-20 mA Input Dual SPDT Alarms
4-20 mA
18V Loop Supply
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1040 G
DC Input SPDT Alarm +
Transmitter
DC Voltage or Current
Specify Range
18V Loop Supply
1 SPDT Contact Set
Field Adjustable Hi Alarm
Non-Isolated DC Voltage or
Current Transmitter
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1080 G
Field Settable
DC Input DPDT Alarm

1080 G Ranges
1080 G Help
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
1 DPDT Contact Set
Field Adjustable
Selectable Alarm Action
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1080 DIN
Field Settable
DC Input DPDT Alarm
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
1 DPDT Contact Set
Field Adjustable
Selectable Alarm Action
80-265 VAC
48-300 VDC
API 1090 G
Field Settable DC Input
Dual SPDT Alarms

1090 G Ranges
1090 G Help
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
2 SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1090 DIN
Field Settable DC Input
Dual SPDT Alarms
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
2 SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
80-265 VAC
48-300 VDC
API 1090 DD
Field Settable DC Input
Dual SPDT Alarms
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
2 SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
9-30 VDC

  DC - DC Transmitters

 

Click here to download DC Input pdf
Model Input Output Power
API 4010 G
DC-DC Transmitter, Non-Isolated
DC Voltage or Current
Specify Range
18V Loop Supply
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4050 G
DC-DC Transmitter, Non-Isolated
Narrow Input Span
DC Voltage or Current
Specify Range
Narrow Input Span
18V Loop Supply
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4300 G
DC-DC Transmitter, Isolated
DC Voltage or Current
Factory Set Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4310 G
DC-DC Transmitter, Isolated
Narrow Input Span
DC Voltage or Current
Specify Range
Narrow Input Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4380 G
DC-DC Transmitter, Isolated
Field Rangeable

4380 G Ranges
4380 G Help
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
C Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4380 GHV3
Hi Voltage DC-DC Transmitter,
Isolated
Field Rangeable

4380 GHV3 Ranges
DC Voltage or Current
Field Selectable Ranges
High Voltage Input to
±200 VDC
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4380 DIN
DC-DC Transmitter, Isolated
Field Rangeable

4380 DIN Help
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
80-265 VAC
48-300 VDC
API 4380 DD
DC-DC Transmitter, Isolated
Field Rangeable

4380 DIN Help
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
9-30 VDC
API 4385 G
DC-DC Transmitter, Isolated
Field Rangeable

4385 G Ranges
DC Voltage or Current
Field Selectable Ranges
True Offset
Non-Interacting Controls
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
DPI HV-DC
Hi Voltage DC-DC Transmitter,
Isolated
Field Rangeable

DPI HV-DC Ranges
High Voltage DC
0-100VDC to 0-1200VDC
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4390
2 Channel DC-DC Transmitter,
Isolated

DC Volts or mA
2 Independent Channels
Fully Isolated
DC Voltage or Current
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4391
2 Channel DC-DC Transmitter,
Isolated, Bipolar Output
DC Volts or mA
2 Independent Channels
Fully Isolated
Bipolar ±5 Volts or ±10 Volts
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4392
2 Channel DC-DC Transmitter,
Isolated, Bipolar Input & Output
Bipolar ±DC Volts or ±mA
2 Independent Channels
Fully Isolated
Bipolar ±DC Volts or mA
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4393
IsoSplitter

DC-DC Signal Splitter,
Isolated
One DC Voltage or Current Fully Isolated
Two Independent
DC Voltage or
Current Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4393 L1
IsoSplitter

DC-DC Signal Splitter,
Isolated
Sourced Input,
Source or Sink Outputs
One 4-20 mA
18V Loop Power Supply
Fully Isolated
Two Independent
4-20 mA Channels
Source or Sink Outputs
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC

 Loop-Powered Isolators

 

Click here to download DC Input pdf
Model Input Output Power
API LPI-1
Loop-Powered Isolator
4-20 mA Fully Isolated
4-20 mA
Loop Powered
API LPI-2
Dual Channel
Loop-Powered Isolator
Two 4-20 mA Fully Isolated
Two 4-20 mA
Loop Powered
DPI-2
Dual Channel
Loop-Powered Isolator
Two 4-20 mA Fully Isolated
Two 4-20 mA
Loop Powered

Loop Power Supplies 

 

 
Model Input Output Power
API 9046
Power Supplies

115 VAC Std.
Opt. 230 VAC

Isolated
Regulated DC Voltage
Specify 5 to 32 VDC

115 VAC Std.
Opt. 230 VAC

API 9046 CH
Bipolar Power Supplies

115 VAC Std.
Opt. 230 VAC

Isolated
Regulated DC Voltage
Bipolar (±) Output VDC
Specify ±5 to ±15 VDC

115 VAC Std.
Opt. 230 VAC

  Thermocouple Input

 

Click here to download Temperature Input pdf
Model Input Output Power
API 1200 G
T/C Input DPDT Alarm
J, K, T, E Thermocouple
Specify Type & Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1220 G
T/C Input Dual SPDT Alarms
J, K, T, E Thermocouple
Specify Type & Range
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable

4000 G Ranges
4000 G Help
J, K, T, E, R, S Thermocouple
Most  RTDs &
Resistance Elements
Field Selectable Type &  Range

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4100 G
T/C Input Transmitter,
Non-Isolated, Non-Linearized
J, K, T, E Thermocouple
Specify Type & Range

DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4130 GL
T/C Input Transmitter,
Isolated, Linearized
J, K, T, E Thermocouple
Specify Type & Range

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

 RTD Input 

 

Click here to download Temperature Input pdf
Model Input Output Power
API 1400 G
RTD Input DPDT Alarm
10 Ω to 2000 Ω RTDs
Factory Set Type & Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1420 G
RTD Input Dual SPDT Alarms
10 Ω to 2000 Ω RTDs
Specify Type & Range
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable

4000 G Ranges
4000 G Help
Most  RTDs &
Resistance Elements
J, K, T, E, R, S Thermocouple
Field Selectable Type &  Range
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4001 G
RTD Input Transmitter, Non-Isolated,
Non-Linearized
10 Ω to 2000 Ω RTDs
Specify Type & Range
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4001 GL
RTD Input Transmitter, Isolated,
Linearized
10 Ω to 2000 Ω RTDs
Specify Type & Range
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4001 G SA-B
Differential 2 RTD Input Transmitter,
Non-Isolated,
Non-Linearized
Two 100 Ω 0.00385 RTDs
For Differential Temperature
Factory Set,
Can Be Field Calibrated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  Frequency Modules

 Click at Right for Details:

Click here to download Frequency pdf
Model Input Output Power
API 1700 G
Frequency Input DPDT Alarm
10 Hz to 20 KHz
Specify Input Span
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1720 G
Frequency Input Dual SPDT Alarms
10 Hz to 20 KHz
Specify Input Span
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7010 G
Frequency to DC Transmitter, Isolated
10 Hz to 20 KHz
Specify Input Span

Fully Isolated
DC Voltage or Current
Specify Range

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7500 G
 DC to Frequency Transmitter, Isolated

7500 G Ranges
7500 G Help
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7500 G SS
DC to Low Frequency Transmitter, Isolated

7500 G SS Ranges
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7580 G
Frequency to DC Transmitter, Isolated
Field Rangeable

7580 G Ranges
7580 G Help
100 Hz to 30 KHz
Field Selectable Ranges
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  AC Input

 

Click here to download AC Input pdf
Model Input Output Power
API 1600 G
AC Input DPDT Alarm
AC Voltage or Current
Specify Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1620 G
AC Input Dual SPDT Alarms
AC Voltage or Current
Specify Range
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6010 G
AC to DC Transmitter, Isolated
AC Voltage or Current
Specify Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6010 G 5A &
API 6010 G 20A

C to DC Transmitters, Isolated
High Current
AC Current (up to 20 A)
Specify Range
Socket & Shunt Included
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6380 G
AC to DC Transmitter, Isolated
Field Rangeable

6380 G Ranges
6380 G Help
AC Voltage or Current
Field Selectable Ranges
18V Loop Supply

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 6380 G S
True RMS AC to DC Transmitter,
Isolated
Field Rangeable

6380 G S Ranges
6380 G S Help
True RMS
AC Voltage or Current
Field Selectable Ranges
18V Loop Supply

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  Potentiometer

 

Click here to download Potentiometer Input pdf
Model Input Output Power
API 1800 G
Potentiometer Input DPDT Alarm
0-100 Ω to
0-1 Mega Ω
Potentiometer
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1820 G
Potentiometer Input Dual SPDT Alarms
0-100 Ω to
0-1 Mega Ω
Potentiometer
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4003 G
Potentiometer to DC Transmitter,
Non-Isolated
0-100 Ω to
0-1 Mega Ω
Potentiometer
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4003 G I
Potentiometer to DC Transmitter,
Isolated
0-100 Ω to
0-1 Mega Ω
Potentiometer
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4008 G
Potentiometer to DC Transmitter,
Isolated
Field Rangeable
0-100 Ω to
0-1 Mega Ω
Potentiometer
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

 Strain Gauge,
 Bridge, Load Cell Input
 

 

Click here to download Strain Gauge Input pdf
Model Input Output Power
API 1500 G
Strain Gauge Input DPDT Alarm
Strain Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1520 G
Strain Gauge Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4051 G
Single Strain Gauge to
DC Transmitter,
Non-Isolated
Strain Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4058 G
1-4 Strain Gauge to
DC Transmitter,
Non-Isolated

4058 G Ranges
4058 G Help
1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation

DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4059 G
1-4 Strain Gauge to
DC Transmitter, Isolated

4059 G Help
4059 G Ranges
1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4059 DIN
1-4 Strain Gauge to
DC Transmitter, Isolated

4059 DIN Ranges

1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API SUM 000
Strain Gauge Summing Board
API SUM 025
Summing Board with API 4059
API SUM 100
Summing Board w. NEMA 4X Box
API SUM 125
Summing Board, API 4059, NEMA 4X Box
Summing Assembly Board
1 to 4 Strain Gauges,
Bridges, or Load Cells
Individually Adjustable
Excitation & Signal Trim
Optional SS Housing

DC Voltage or Current
Use with 4058 G or
4059 G

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

 Valve Position,
 Math & P-I Converters

 

Click here to download Valve/Math pdf
Model Input Output Power
API 3200 G
Valve Positioner/Actuator
DC Voltage or Current
Specify Range
100 Ω to 100 kΩ
Feedback Pot
Valve / Actuator
Positioner / Controller
2 SPST Relays
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4400 G (A+B+C+D) / 4
API 4401 G
(A+B+C) / 3
API 4402 G
(A+B) / 2
API 4403 G
(A+B+C–D) / 3
API 4404 G
(A+B–C–D) / 4
API 4405 G
(A–B–C–D)
API 4406 G
(A+B–C) / 2
API 4407 G
(A–B–C)
API 4408 G
(A–B)
Up to 4 DC Voltage or
Current Inputs
Specify Ranges
Addition, Subtraction,
Averaging Versions
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4440 G
DC to DC Transmitter,
Square Root Extraction
DC Voltage or Current
Specify Range
18V Loop Supply
Square Root Extraction
Full Isolated
DC Voltage or Current
 Square Root of Input
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
DPG1000L3-15PSIG
Pressure to Current Converter
3.00 to 15.00 psig 4-20 mA Loop Powered
F4L3-15PSIG
Pressure to Current Converter,
NEMA 4X
3.00 to 15.00 psig 4-20 mA Loop Powered

  Module Accessories

 

Click here to download Accessories pdf
Sockets & Housings

 

8-Pin, 11-Pin Sockets
8-Pin, 11-Pin Finger-Safe Sockets
DIN Rail
Module Housings

 Current

 

Click here to download current Sensor pdf
Model Input Output Power
CTX-ACR
AC Current Transmitters
 True RMS
 0-2 Amps to 
 0-200 Amps AC
Isolated Output
4-20 mA
Loop Powered
CTX-ACR-3S & 4S
High AC Current Transmitters
 True RMS
 0-375 Amps to 
 0-2000 Amps AC
Isolated Output
4-20 mA
Loop Powered
CTX-DC
DC Current Transmitters
 0-50 Amps to
 0-400 Amps DC
Isolated Output
4-20 mA
20-50 VDC or
 22-38 VAC
CS-AC
AC Current Switches
 1.5-150 Amps AC 0.15 Amp SSR
LED Status Indicator
NC or NO Models
Self Powered
CS-DC
DC Current Switches
 5-100 Amps DC 0.3 Amp SSR or
5 Amp Relay
LED Status Indicator
20-28 VAC/VDC or
12 VAC/VDC
LED Power Indicator
2RL/5RL/7RL/8RL
AC Current Transformers
 600 VAC 
 50:5 to 1600:5 Ratios
Proportional to Input Self Powered

  OEM Products

Custom Electronics Custom Signal Conditioners, Signal  Converters,  Instrumentation
Call us at 800-783-6664 or email Sales Department
 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117