Shopping Cart: MyProfile | Log Out
0   Items  In Cart |  Total: $0.00

Abbeon
AEMC
Alnor
Amprobe
APG
Atago
Bacharach
Checkline
Compact Inst.
Cooke
Datatrack
Defelsko
Dickson
Digimed
Extech
Fluke
F.W. Bell
GIC
Global Water
Goldak
Graphtec
Hart Scientific
Hanna
Honeywell
Horiba
Instek
Jenco
McDonnellMiller
Megger
Monarch
Novasina
Oakton
Partlow
Reed
Revere
Rotronic
Rustrak
Shimpo
Signet
Vulcain
West Instruments
YSI
See Whole List . . .

Clamp-On Meters
Electrical
Force Meters
Multimeters
Power Quality Analyzers
Stroboscope
Tachometers
See Whole List . . .

Air Quality
Combustion Gas Analyzer
Controllers
LightMeters
SoundMeters
See Whole List . . .
Flow
Level
Pressure
Data Chart
Panel Indicator
Paperless
Humidity
Thermometers
Water Quality



Api Product Line
Return To Main Page



DC Input Alarm Trips | Loop Power Supplies | Frequency Modules | Strain Gauge Bridge,
Load Cell Input
| DC Transmitters | Thermocouple Input | AC Input | Current Sensors
Valve Position, Math & P-I Converters | Loop-Powered Isolators | RTD Input
Potentiometer Input | OEM Products | Module Accessories

DC Input Alarm Trips
Model Input Output Power
API 1000 G
DC Input DPDT Alarm
DC Voltage or Current
Specify Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1020 G
DC Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
API 1005 G
4-20 mA Input DPDT Alarm
4-20 mA
18V Loop Supply
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1025 G
4-20 mA Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
API 1040 G
DC Input SPDT Alarm +
Transmitter
DC Voltage or Current
Specify Range
18V Loop Supply
1 SPDT Contact Set
Field Adjustable Hi Alarm
Non-Isolated DC Voltage or Current Transmitter
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1080 G
Field Settable DC Input DPDT Alarm
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
1 DPDT Contact Set
Field Adjustable
Selectable Alarm Action
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1080 DIN
Field Settable DC Input DPDT Alarm
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
1 DPDT Contact Set
Field Adjustable
Selectable Alarm Action
80-265 VAC
48-300 VDC
API 1090 G
Field Settable DC Input
Dual SPDT Alarms
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
2 SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1090 DIN
Field Settable DC Input
Dual SPDT Alarms
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
2 SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
80-265 VAC
48-300 VDC
API 1090 DD
Field Settable DC Input
Dual SPDT Alarms
9-30 VDC
DC Transmitters
Model Input Output Power
API 4010 G
DC-DC Transmitter, Non-Isolated
DC Voltage or Current
Specify Range
18V Loop Supply
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4050 G
DC-DC Transmitter, Non-Isolated, Narrow Input Span
API 4300 G
DC-DC Transmitter, Isolated
  DC Voltage or Current
Factory Set Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4310 G
DC-DC Transmitter, Isolated, Narrow Input Span
API 4380 G
DC-DC Transmitter, Isolated, Field Rangeable
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
C Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4380 GHV3
HiVoltage DC-DC Transmitter Isolated, Field Rangeable
DC Voltage or Current
Field Selectable Ranges
High Voltage Input to
±200 VDC
18V Loop Supply
API 4380 DIN
DC-DC Transmitter, Isolated Field Rangeable
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
80-265 VAC
48-300 VDC
API 4380 DD
DC-DC Transmitter, Isolated Field Rangeable
9-30 VDC
API 4385 G
DC-DC Transmitter, Isolated Field Rangeable
DC Voltage or Current
Field Selectable Ranges, True Offset
Non-Interacting Controls
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
DPI HV-DC
HiVoltage DC-DC Transmitter, Isolated, Field Rangeable
High Voltage DC
0-100VDC to 0-1200VDC
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4390
2 Channel DC-DC Transmitter,
Isolated
DC Volts or mA
2 Independent Channels
Fully Isolated
DC Voltage or Current
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4391
2 Channel DC-DC Transmitter,
Isolated, Bipolar Output
Fully Isolated
Bipolar ±5 Volts or ±10 Volts
2 Independent Channels
API 4392
2 Channel DC-DC Transmitter,
Isolated, Bipolar Input & Output
Bipolar ±DC Volts or ±mA
2 Independent Channels
Fully Isolated
Bipolar ±DC Volts or mA
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4393 IsoSplitter ™
DC-DC Signal Splitter,
Isolated
One DC Voltage or Current Fully Isolated
Two Independent
DC Voltage or
Current Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4393 L1 IsoSplitter ™
DC-DC Signal Splitter,
Isolated Sourced Input,
Source or Sink Outputs
One 4-20 mA
18V Loop Power Supply
Fully Isolated
Two Independent
4-20 mA Channels
Source or Sink Outputs
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
Loop Powered Isolators
Model Input Output Power
API LPI-1
Loop-Powered Isolator
4-20 mA Fully Isolated 4-20 mA Loop Powered
API LPI-2
Dual Channel
Loop-Powered Isolator
Two 4-20 mA Fully Isolated Two 4-20 mA Loop Powered
DPI-2
Dual Channel
Loop-Powered Isolator
Two 4-20 mA Fully Isolated Two 4-20 mA Loop Powered
Loop Power Supplies
Model Input Output Power
API 9046
Power Supplies
115 VAC Std.
Opt. 230 VAC
Isolated
Regulated DC Voltage
Specify 5 to 32 VDC
115 VAC Std.
Opt. 230 VAC
API 9046 CH
Bipolar Power Supplies
Isolated
Regulated DC Voltage
Bipolar (±) Output VDC
Specify ±5 to ±15 VDC
Thermocouple Input
Model Input Output Power
API 1200 G
T/C Input DPDT Alarm
J, K, T, E Thermocouple
Specify Type & Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1220 G
T/C Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
API 4000 G
T/C or RTD Input Transmitter, Isolated, Field Rangeable
J, K, T, E, R, S Thermocouple
Most RTDs &
Resistance Elements
Field Selectable Type & Range
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4100 G
T/C Input Transmitter,
Non-Isolated, Non-linearized
J, K, T, E Thermocouple
Specify Type & Range
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4130 GL
T/C Input Transmitter, Isolated, Linearized
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
RTD Input
Model Input Output Power
API 1400 G
RTD Input DPDT Alarm
10Ω to 2000Ω RTDs
Factory Set Type & Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1420 G
T/C Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
API 4001 G
RTD Input Transmitter, Non-Isolated,
Non-Linearized
10Ω to 2000Ω RTDs
Factory Set Type & Range
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4001 GL
RTD Input Transmitter, Isolated, Linearized
Fully Isolated
DC Voltage or Current
Specify Range
API 4001 G SA-B
Differential 2 RTD Input Transmitter, Non-Isolated, Non-Linearized
Two 100Ω 0.00385 RTDs For Differential Temperature Factory Set, Can Be Field Calibrated DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
Frequency Modules
Model Input Output Power
API 1700 G
Frequency Input DPDT Alarm
10 Hz to 20 KHz
Specify Input Span
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1720 G
Frequency Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
API 7010 G
Frequency to DC Transmitter, Isolated
10 Hz to 20 KHz
Specify Input Span
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7500 G
DC to Frequency Transmitter, Isolated
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7500 G SS
DC to Low Frequency Transmitter, Isolated
Fully Isolated
0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL
API 7580 G
Frequency to DC Transmitter, Isolated
Field Rangeable
100 Hz to 30 KHz
Field Selectable Ranges
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
AC Input
Model Input Output Power
API 1600 G
AC Input DPDT Alarm
AC Voltage or Current
Specify Range
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1620 G
AC Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
API 6010 G
AC to DC Transmitter, Isolated
AC Voltage or Current
Specify Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6010 G 5A &
API 6010 G 20A
C to DC Transmitters, Isolated High Current
AC Current (up to 20 A)
Specify Range
Socket & Shunt Included
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6380 G
AC to DC Transmitter, Isolated Field Rangeable
AC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6380 G S
True RMS AC to DC Transmitter, Isolated
Field Rangeable
True RMS
AC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Potentiometer Input
Model Input Output Power
API 1800 G
Potentiometer Input DPDT Alarm
0-100Ω to 0-1 MegaΩ
Potentiometer
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1820 G
Potentiometer Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
API 4003 G
Potentiometer to DC Transmitter, Non-Isolated
0-100Ω to 0-1 MegaΩ
Potentiometer
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4003 G I
Potentiometer to DC Transmitter, Isolated
Fully Isolated
DC Voltage or Current
Specify Range
API 4008 G
Potentiometer to DC Transmitter, Isolated Field Rangeable
0-100Ω to 0-1 MegaΩ
Potentiometer
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
Strain Gauge, Bridge, Load Cell Input
Model Input Output Power
API 1500 G
Strain Gauge Input DPDT Alarm
Strain Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 1520 G
Strain Gauge Input Dual SPDT Alarms
2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
API 4051 G
Single Strain Gauge to
DC Transmitter,
Non-Isolated
Strain Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4058 G
1-4 Strain Gauge to
DC Transmitter, Non-Isolated
1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4059 G
1-4 Strain Gauge to
DC Transmitter, Isolated
1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4059 DIN
1-4 Strain Gauge to
DC Transmitter, Isolated
1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API SUM 000
Strain Gauge Summing Board
API SUM 025
Summing Board with API 4059
API SUM 100
Summing Board w. NEMA 4X Box
API SUM 125
Summing Board, API 4059, NEMA 4X Box
Summing Assembly Board
1 to 4 Strain Gauges,
Bridges, or Load Cells
Individually Adjustable
Excitation & Signal Trim
Optional SS Housing
DC Voltage or Current
Use with 4058 G or
4059 G
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
Valve Position, Math & P-I Converters
Model Input Output Power
API 3200 G
Valve Positioner/Actuator
DC Voltage or Current
Specify Range
100Ω to 100kΩ
Feedback Pot
Valve / Actuator
Positioner / Controller
2 SPST Relays
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4400 G
API 4401 G
API 4402 G
API 4403 G
API 4404 G
API 4405 G
API 4406 G
API 4407 G
API 4408 G
Up to 4 DC Voltage or
Current Inputs
Specify Ranges
Addition, Subtraction,
Averaging Versions
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4440 G
DC to DC Transmitter,
Square Root Extraction
DC Voltage or Current
Specify Range
18V Loop Supply
Square Root Extraction
Full Isolated
DC Voltage or Current
Square Root of Input
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
DPG1000L3-15PSIG
Pressure to Current Converter
3.00 to 15.00 psig 4-20 mA Loop Powered
F4L3-15PSIG
Pressure to Current Converter, NEMA 4x
Module Accessories
Model Description
Sockets & Housings 8-Pin, 11-Pin Sockets
8-Pin, 11-Pin Finger-Safe Sockets
DIN Rail
Module Housings
Current
Model Input Output Power
CTX-ACR
AC Current Transmitters
True RMS
0-2 Amps to
0-200 Amps AC
Isolated Output
4-20 mA
Loop Powered
CTX-ACR-3S & 4S
High AC Current Transmitters
True RMS
0-375 Amps to
0-2000 Amps AC
Isolated Output
4-20 mA
Loop Powered
CTX-DC
DC Current Transmitters
0-50 Amps to
0-400 Amps DC
Isolated Output
4-20 mA
20-50 VDC or
22-38 VAC
CS-AC
AC Current Switches
1.5-150 Amps AC 0.15 Amp SSR
LED Status Indicator
NC or NO Models
Self Powered
CS-DC
DC Current Switches
5-100 Amps DC 0.3 Amp SSR or
5 Amp Relay
LED Status Indicator
20-28 VAC/VDC or
12 VAC/VDC
LED Power Indicator
2RL/5RL/7RL/8RL
AC Current Transformers
600 VAC
50:5 to 1600:5 Ratios
Proportional to Input Self Powered
OEM Products
Custom Electronics Custom Signal Conditioners, Signal Converters, Instrumentation
Call us at 800-783-6664