ABBE
REFRACTOMETER DR-A1 |
|
|
By
very simple operation that needs only to set the boundary line
of refraction at the cross hairs, this refractometer directly
indicates a measured value ( in refractive index or Brix ( % ) ,
selective ) in digits together with temperature on the display.
This refractometer enables anybody to carry out measurement
easily without reading of analog graduation.
*Dispersive value cannot be measured by this refractometer. |
|
|
| Cat.No. |
1310 |
| Model |
DR-A1 |
| Measurement
range |
Refractive
index ( nD ) 1.3000 to 1.7100
Brix 0.0 to 95.0%
( Automatic Temperature Compensation is executed
at 5 to 50°C ) |
| Minimum
indication |
Refractive
index ( nD ) 0.0001
Brix 0.1% |
| Measurement
accuracy |
Refractive
index ( nD ) ± 0.0002
Brix ± 0.1% |
Measurement
temperature range |
5 to 50°C
( at unit of 0.1°C ) |
| Indication |
Refractive
index ( nD ) or Brix ( % ) and temperature ( °C
) |
| Power
supply |
With AC
adapter ( 100 to 240V ( 50/60Hz ) AC input ) |
| Power
consumption |
10VA |
| Optional |
| RE-1581 |
Adapter for film sample |
|
| Parts |
| RE-1501 |
Main & secondary prism for DR-A1 |
| RE-1592 |
Pack of desiccant tablets |
| RE-8507 |
Tube band |
|
| Dimensions
and weight |
Refractometer
13x29x31cm, 6.0kg
AC adapter 10.5x17.5x4 cm, 0.7kg |
|
|
|
| The NAR-1T is an
Abbe refractometer of standard type, measures refractive indices
of liquids and solids quickly and accurately. It is designed to
give refractive indices of D line without using a sodium lamp. |
|
|
| Cat.No. |
1210 |
| Model |
NAR-1T |
| Measurement
range |
Refractive
index ( nD )
1.3000 to1.7000
Brix 0.0 to 95.0% |
| Minimum
scale |
Refractive
index ( nD ) 0.001
Brix 0.5% |
| Measurement
accuracy |
Refractive
index ( nD ) ± 0.0002
Brix± 0.1% |
Measurement
temperature range |
0 to 50°C |
| Light
source |
8V,0.15A
tungsten lamp |
| Power
supply |
115V,
220V, 240V ( Select one when you place an order.
) 50/60Hz |
| Power
consumption |
6VA |
| Optional |
| RE-1498 |
Test piece D for measurement of film |
| RE-1196 |
Monobromona-phthalene as contact
liquid |
| RE-1199 |
Methylene iodide containing sulfur
solution |
| RE-1145 |
Eyepiece for polarizing |
|
| Parts |
| RE-1103 |
Main prism for 1T (For 3PIN)* |
| RE-1104 |
Main prism for 1T (For 4PIN)* |
| RE-1111 |
Secondary prism for 1T |
| RE-1164 |
Thermo display unit (DTM-1)
<110V> * |
| RE-1165 |
Thermo display unit (DTM-1)
<220V> * |
| RE-1166 |
Thermo display unit (DTM-1)
<240V> * |
| RE-1157 |
Thermistor unit C * |
| RE-1158 |
Thermistor unit E * |
| RE-1170 |
Lamp for illuminator (8V, 0.15A) |
| RE-1175 |
Lamp cable |
| RE-1187 |
Desiccant 10g |
| RE-1152 |
Fuse ( 0.315A ) |
| RE-1195 |
Test piece A with
m-naphthalene |
| RE-8507 |
Tube band |
*Please inform us of a
serial number in the case of an order. |
| Dimensions
and weight |
Refractometer
13x18x23cm, 3.4kg
Thermometer 8x10x11cm, 0.8kg |
|
|
|
|
| Designed for use
with compounds which require measurement at high temperature. |
|
|
| Cat.No. |
1220 |
| Model |
NAR-2T |
| Measurement
range |
Refractive
index ( nD ) 1.3000 to 1.7000
Brix 0.0 to 95.0% |
| Minimum
scale |
Refractive
index ( nD ) 0.001
Brix 0.5% |
| Measurement
accuracy |
Refractive
index ( nD ) ± 0.0002
Brix ± 0.1% |
| Average
dispersion value |
nF-nC (
to be calculated according to conversion table ) |
| Digital
thermometer |
Indication
range 0.0 to 50.0°C
( Accuracy ± 0.2°C Minimum indication 0.1°C ) |
Measurement
temperature range |
0 to 120°C |
| Power
supply |
115V,
220V, 240V ( Select one when you place an order.
) 50/60Hz |
| Power
consumption |
6VA |
| Optional |
| RE-1498 |
Test piece D for measurement of film |
| RE-1196 |
Monobromona-phthalene as contact
liquid |
| RE-1199 |
Methylene iodide containing sulfur
solution |
| RE-1145 |
Eyepiece for polarizing |
|
| Parts |
| RE-1203 |
Main & secondary prism for 2T (For
3PIN)* |
| RE-1204 |
Main & secondary prism for 2T (For
4PIN)* |
| RE-1164 |
Thermo display unit (DTM-1)
<110V> * |
| RE-1165 |
Thermo display unit (DTM-1)
<220V> * |
| RE-1166 |
Thermo display unit (DTM-1)
<240V> * |
| RE-1357 |
Thermistor unit D* |
| RE-1358 |
Thermistor unit F* |
| RE-1170 |
Lamp for illuminator (8V, 0.15A) |
| RE-1187 |
Desiccant 10g |
| RE-1152 |
Fuse (0.315A) |
| RE-1195 |
Test piece A with
m-naphthalene |
| RE-8507 |
Tube band |
*Please inform us of a
serial number in the case of an order. |
| Dimensions
and weight |
Refractometer
12x20x25cm, 5.8kg
Thermometer 8x10x11cm, 0.8kg |
|
|
|
|
| The NAR-3T has
been developed to give improved measuring accuracy and ease of
use. This has been achieved by making fundamental improvements
to the optical system, utilizing a larger scale, incorporating a
high intensity lamp and using a double control knob to give
quick and finer control. |
|
|
| Cat.No. |
1230 |
| Model |
NAR-3T |
| Measurement
range |
Refractive
index ( nD ) 1.30000 to 1.71000
Brix 0.00 to 95.00% |
| Minimum
scale |
Refractive
index ( nD ) 0.0002
Brix 0.1% |
| Measurement
accuracy |
Refractive
index ( nD ) ± 0.0001
Brix ± 0.05% |
| Average
dispersion value |
nF-nC (
to be calculated according to conversion table ) |
| Digital
thermometer |
Indication
range 0.0 to 50.0°C
( Accuracy ± 0.2°C Minimum indication 0.1°C ) |
Measurement
temperature range |
0 to 50°C |
| Light
source |
6V,1.2A
tungsten lamp for sample illuminator |
| Power
supply |
115V,
220V, 240V ( Select one when you place an order.
) 50/60Hz |
| Power
consumption |
18VA |
| Optional |
| RE-1498 |
Test piece D for measurement of film |
| RE-1196 |
Monobromona-phthalene as contact
liquid |
| RE-1199 |
Methylene iodide containing sulfur
solution |
| RE-1145 |
Eyepiece for polarizing |
|
| Parts |
| RE-1303 |
Main & secondary prism for 3T (For
3PIN)* |
| RE-1304 |
Main & secondary prism for 3T (For
4PIN)* |
| RE-1364 |
Thermo display unit (DTM-1)
<110V> * |
| RE-1365 |
Thermo display unit (DTM-1)
<220V> * |
| RE-1366 |
Thermo display unit (DTM-1)
<240V> * |
| RE-1357 |
Thermistor unit D* |
| RE-1358 |
Thermistor unit F* |
| RE-1170 |
Lamp for illuminator (8V, 0.15A) |
| RE-1372 |
Lamp for sample filed illuminator (6V,
1.2A) |
| RE-1187 |
Desiccant 10g |
| RE-1152 |
Fuse (0.315A) |
| RE-1195 |
Test piece A with
m-naphthalene |
| RE-8507 |
Tube band |
*Please inform us of a
serial number in the case of an order. |
| Dimensions
and weight |
Refractometer
12x31x25cm, 9.0kg
Thermometer 8x10x11cm, 0.8kg |
|
|
|
| R&D on new
materials for modern technologies is being actively conducted in
every industry. Many of these materials ( especially polymer
film and related materials ) are of high refractive index-often
too high for the existing Abbe refractometers. But these are now
covered with the nD1.4700 to 1.8700 range of the NAR-4T. |
|
|
| Cat.No. |
1240 |
|
Model
|
NAR-4T |
| Measurement
range |
Refractive
index ( nD ) 1.4700 to 1.8700 |
| Minimum
scale |
Refractive
index ( nD ) 0.001 |
| Measurement
accuracy |
Refractive
index ( nD ) ± 0.0002 |
| Digital
thermometer |
Indication
range 0.0 to 50.0°C
( Accuracy ± 0.2°C Minimum indication 0.1°C ) |
Measurement
temperature range |
0 to 50°C |
| Light
source |
8V,
0.15A tungsten lamp |
| Power
supply |
115V,
220V, 240V ( Select one when you place an order.
) 50/60Hz |
| Power
consumption |
6V |
| Optional |
| RE-1499 |
Test piece D for measurement of film |
| RE-1196 |
Monobromona-phthalene as contact
liquid |
| RE-1199 |
Methylene iodide containing sulfur
solution |
| RE-99005 |
Contact liquid LH |
| RE-1145 |
Eyepiece for polarizing |
|
| Parts |
| RE-1403 |
Main prism for 4T (For 3PIN) * |
| RE-1404 |
Main prism for 4T (For 4PIN) * |
| RE-1411 |
Secondary prism for 4T |
| RE-1164 |
Thermo display unit (DTM-1)
<110V> * |
| RE-1165 |
Thermo display unit (DTM-1)
<220V> * |
| RE-1166 |
Thermo display unit (DTM-1)
<240V> * |
| RE-1357 |
Thermistor unit C * |
| RE-1358 |
Thermistor unit E * |
| RE-1170 |
Lamp for illuminator (8V, 0.15A) |
| RE-1175 |
Lamp cable |
| RE-1187 |
Desiccant 10g |
| RE-1152 |
Fuse (0.315A) |
| RE-1195 |
Test piece A with
m-naphthalene |
| RE-8507 |
Tube band |
*Please inform us of a
serial number in the case of an order. |
| Dimensions
and weight |
Refractometer
13x18x23cm, 3.4kg
Thermometer 8x10x11cm, 0.8kg |
|
|
Abbe Refractometers for low refractive index and high
refractive index measurements
In addition to our standard Abbe Refractometer NAR-1T, 2T, 3T,
4T and DR-A1, we can supply the following Abbe models.
We shall ask you to use them if the specifications of our
standard Abbe Refractometers do not meet your requirements.
Another Optional
*We can supply Abbe Refractometer with measurement range of
"nD 1.7000 to 2.0800" and with measurement temperature
range of "0 to 50°C" or "0 to 120°C".
Note:You are requested to convert measured refractive indices to
"real refractive indices" ( with referring to
conversion tables ) , since the above Abbe Refractometers have
the same scales as our standard Abbe Refractometer NAR-1T and
2T.
|
|
|
| Cat.No. |
1217 |
| Model |
1TLO |
| Measurement
range |
Refractive
index ( nD ) 1.1500 to 1.4800 |
| Measurement
temperature range |
0 to 50°C |
| Optional |
| RE-1196 |
Monobromona-phthalene as contact
liquid |
| RE-1199 |
Methylene iodide containing sulfur
solution |
| RE-1145 |
Eyepiece for polarizing |
|
| Parts |
| RE-1111 |
Secondary prism for 1T |
| RE-1164 |
Thermo display unit (DTM-1)
<110V> * |
| RE-1165 |
Thermo display unit (DTM-1)
<220V> * |
| RE-1166 |
Thermo display unit (DTM-1)
<240V> * |
| RE-1157 |
Thermistor unit C * |
| RE-1158 |
Thermistor unit E * |
| RE-1170 |
Lamp for illuminator (8V, 0.15A) |
| RE-1175 |
Lamp cable |
| RE-1187 |
Desiccant 10g |
| RE-1152 |
Fuse (0.315A) |
| RE-1195 |
Test piece A with m-naphthalene |
| RE-8507 |
Tube band |
*Please inform us of a
serial number in the case of an order. |
|
|
|
|
| Cat.No. |
1227 |
| Model |
2TLO |
| Measurement
range |
Refractive
index ( nD ) 1.1500 to 1.4800 |
| Measurement
temperature range |
0 to 120°C |
| Optional |
| RE-1498 |
Test piece D for measurement of film |
| RE-1196 |
Monobromona-phthalene as contact
liquid |
| RE-1199 |
Methylene iodide containing sulfur
solution |
| RE-1145 |
Eyepiece for polarizing |
|
| Parts |
| RE-1164 |
Thermo display unit (DTM-1)
<110V> * |
| RE-1165 |
Thermo display unit (DTM-1)
<220V> * |
| RE-1166 |
Thermo display unit (DTM-1)
<240V> * |
| RE-1357 |
Thermistor unit D* |
| RE-1358 |
Thermistor unit F* |
| RE-1170 |
Lamp for illuminator (8V, 0.15A) |
| RE-1187 |
Desiccant 10g |
| RE-1152 |
Fuse (0.315A) |
| RE-1195 |
Test piece A with
m-naphthalene |
| RE-8507 |
Tube band |
*Please inform us of a
serial number in the case of an order. |
|
|
|
|
| Cat.No. |
1228 |
| Model |
2THI |
| Measurement
range |
Refractive
index ( nD ) 1.4700 to 1.8700 |
| Measurement
temperature range |
0 to 120°C |
| Optional |
| RE-1498 |
Test piece D for measurement of film |
| RE-1196 |
Monobromona-phthalene as contact
liquid |
| RE-1199 |
Methylene iodide containing sulfur
solution |
| RE-99005 |
Contact liquid LH |
| RE-1145 |
Eyepiece for polarizing |
|
| Parts |
| RE-1164 |
Thermo display unit (DTM-1)
<110V> * |
| RE-1165 |
Thermo display unit (DTM-1)
<220V> * |
| RE-1166 |
Thermo display unit (DTM-1)
<240V> * |
| RE-1357 |
Thermistor unit D
* |
| RE-1358 |
Thermistor unit F * |
| RE-1170 |
Lamp for illuminator (8V, 0.15A) |
| RE-1187 |
Desiccant 10g |
| RE-1152 |
Fuse (0.315A) |
| RE-1195 |
Test piece A with
m-naphthalene |
| RE-8507 |
Tube band |
*Please inform us of a
serial number in the case of an order. |
|
|
|
| The 60-C3 is an
external circulation type constant temperature water tank
provided with a thermo-module. The temperature can be set in the
range of 10 to 60°C and the unit is perfectly suited for
connection with a refractometer. |
|
|
| Cat.No. |
1921 |
| Model |
60-C3 |
| Tank
capacity |
0.5 lit |
| Temperature
setting range |
10 to 60°C
( water ) |
| Constant-tempereture
accuracy |
± 0.2°C
or less |
| Temperature
control |
PID
control method using a thermo-module |
| Flow
rate |
4
lit./min |
| Temperature
display |
LED ( red ) |
| Setting display |
LED ( green ) |
| Nozzle |
External
diameter of 9mm, 2 pieces |
| Temperature
sensor |
Platinum
thermometer bulb |
| Safety
device |
Overheating
preventing device and low-water cut off device |
| Power
supply |
AC 100
to 240V, 50 / 60Hz |
| Power
consumption |
370VA |
| Size
& weight |
38x24x27cm,
11kg |
| Accessory |
Connection
hose ( 2m ) |
|
|
 |
 |