MULTI-WAVELENGTH
ABBE REFRACTOMETER DR-M2 |
|
|
|
Refractive
index or Abbe number ( v d or v e ) can be measured at different
wavelengths ranging from 450 to 1,100nm.
The DR-M2 digitally displays measurement result of refractive
index or Abbe number on the LCD.
Measurement can be achieved by matching the boundary line with
the intersection point of the cross hairs.
This refractometer is connectable with digital
printer DP-21 ( A ) ( Optional ). |
|
|
| Cat.No. |
1410 |
| Model |
DR-M2 |
| Measurement
range |
Wavelength
450nm : Refractive index 1.3277 to 1.7379
Wavelength 589nm : Refractive index 1.3000 to
1.7100
Wavelength 680nm : Refractive index 1.2912 to
1.7011
Wavelength 1,100nm : Refractive index 1.2746 to
1.6843 |
| Minimum
indication |
0.0001
in refractive index
0.1 in Abbe number |
| Measurement
accuracy |
±
0.0002 in refractive index
± 0.1 in Abbe number |
Measurement
temperature range |
5 to 50°
C |
| Output
terminal |
For
printer, DP-21 (A) (Optional) |
| Power
supply |
AC100 to
240V 50/60Hz |
| Optional |
| Cat.No.3011 |
Digital Printer DP-21
(A) |
| RE-3520 |
589nm (D) Interference filter |
| RE-3521 |
486nm (F) Interference filter |
| RE-3522 |
656nm (C) Interference filter |
| RE-3523 |
546nm (e) Interference filter |
| RE-3524 |
480nm (F') Interference filter |
| RE-3525 |
644nm (C') Interference filter |
| RE-3526 |
Interference filter (select one
wavelength) |
| 450nm to 539nm |
| 540nm to 680nm |
| 681nm to 799nm |
| 800nm to 1550nm |
| RE-9115 |
Near-infrared ray viewer (with
Adaptor) |
|
|
Parts
|
| RE-1600 |
Main & secondary prism for DR-M2 |
| RE-4170 |
Illuminating lamp for DR-M2 |
| RE-1592 |
Pack of desiccant tablets |
|
| Dimensions
and weight |
Refractometer
13x29x31cm, 6.0kg
Light source unit 15x33x11cm, 3.0kg |
|
|
 |
MULTI-WAVELENGTH
ABBE REFRACTOMETER DR-M4 |
|
|
|
Refractive
index or Abbe number ( v d or v e ) can be measured at different
wavelengths
ranging from 450 to 1,100nm ( For measurement at wavelengths
ranging from 681 to 1,100nm, the Optional Near Infrared Ray
Viewer ( RE-9115 ) is required. )
The DR-M4 displays measurement result of refractive index or
Abbe number digitally on the LCD.
Measurement can be achieved by matching the boundary line with
the intersection point of the cross hairs.
This refractometer is connectable with digital
printer DP-21 ( A ) ( Optional ) . |
|
|
| Cat.No. |
1414 |
| Model |
DR-M4 |
| Measurement
range |
Wavelength
450nm: Refractive index 1.5164 to 1.9164
Wavelength 589nm: Refractive index 1.4700 to
1.8700
Wavelength 680nm: Refractive index 1.4558 to
1.8557
Wavelength 1,100nm: Refractive index 1.4304 to
1.8303 |
| Minimum
indication |
0.0001
in refractive index
0.1 in Abbe number |
| Measurement
accuracy |
±
0.0002 in refractive index ( with the attached
test piece at 500 to 650nm ) |
| Wavelength
range |
From 450
to 1100nm ( with interference filters )
( For measurement at wavelengths ranging from
681 to 1100nm, the Near Infrared Ray Viewer (
Optional ) is required ) |
Measurement
temperature range |
5 to 50°
C |
| Output
terminal |
For
printer, DP-21 (A) (Optional) |
| Power
supply |
AC100 to
240V 50/60Hz |
| Dimensions
and weight |
Refractometer
13x29x31cm, 6.0kg
Light source unit 15x33x11cm, 3.0kg |
| Optional |
| Cat.No.3011 |
Digital Printer DP-21
(A) |
| RE-3520 |
589nm (D) Interference filter |
| RE-3521 |
486nm (F) Interference filter |
| RE-3522 |
656nm (C) Interference filter |
| RE-3523 |
546nm (e) Interference filter |
| RE-3524 |
480nm (F') Interference filter |
| RE-3525 |
644nm (C') Interference filter |
| RE-3526 |
Interference filter (select one
wavelength) |
| 450nm to 539nm |
| 540nm to 680nm |
| 681nm to 799nm |
| 800nm to 1550nm |
| RE-9115 |
Near-infrared ray viewer (with
Adaptor) |
|
| Parts |
| RE-1640 |
Main & secondary prism for DR-M2 |
| RE-4170 |
Illuminating lamp for DR-M2 |
| RE-1592 |
Pack of desiccant tablets |
|
|
|
 |
MULTI-WAVELENGTH
ABBE REFRACTOMETER DR-M2/1550 |
|
Refractive
index or Abbe number ( v d or v e ) can be measured at different
wavelengths
ranging from 450 to1,550nm. This refractometer digitallys
display measurement result of refractive index or Abbe number on
the LCD.This measurement can be achieved by matching the
boundary line withthe intersection point of the cross hairs This
is connectable with digital printer DP-21(A)
(Optional). |
|
|
| Cat.No. |
1412 |
| Model |
DR-M2/1550 |
| Main
components |
Refractometer,
power supply unit,
monochromatic light source device,
near infrared ray viewer,
Interference filter ( 589nm ) . |
| Measurement
range |
Refractive
index
1.3000 to 1.7100 ( at 589nm ) |
| Minimum
indication |
0.0001
in refractive index
0.1 in Abbe number |
| Measurement
accuracy |
±
0.0002 in refractive index ( with the attached
test piece at 589nm ) |
| Wavelength
range |
From 450
to 1,550nm
( with interference filters ) |
Measurement
temperature range |
5 to 50°
C |
| Output
terminal |
For
printer, DP-21 (A) (Optional) |
| Power
supply |
AC100 to
240V 50/60Hz |
| Optional |
| Cat.No.3011 |
Digital Printer DP-21(A) |
| RE-16501 |
Interference filter
589nm (D) |
| RE-16502 |
Interference filter 486nm (F) |
| RE-16503 |
Interference filter 656nm (C) |
| RE-16504 |
Interference filter 546nm (e) |
| RE-16505 |
Interference filter 480nm (F') |
| RE-16506 |
Interference filter 644nm (C') |
| RE-16507 |
Interference filter (select one
wavelength) |
| 450nm to 539nm |
| 540nm to 680nm |
| 681nm to 799nm |
| 800nm to 1550nm |
| RE-16511 |
Frame for Interference Filter 589nm,
DR-M2, M4/1550 |
| RE-16512 |
Frame for Interference Filter 486nm,
DR-M2, M4/1550 |
| RE-16513 |
Frame for Interference Filter 656nm,
DR-M2, M4/1550 |
| RE-16514 |
Frame for Interference Filter 546nm,
DR-M2, M4/1550 |
| RE-16515 |
Frame for Interference Filter 486nm,
DR-M2, M4/1550 |
| RE-16516 |
Frame for Interference Filter 644nm,
DR-M2, M4/1550 |
| RE-16517 |
Frame for Interference Filter of
Optional, DR-M2, M4/1550 |
| RE-9115 |
Near-infrared ray viewer (with
Adaptor) |
|
| Parts |
| RE-16500 |
Main & secondary prism for
DR-M2/1550 |
| RE-1592 |
Pack of desiccant tablets |
|
| Dimensions
and weight |
Refractometer
13x29x31cm, 6.0kg
Light Source unit 15x33x11cm, 3.0kg |
|
|
 |
MULTI-WAVELENGTH
ABBE REFRACTOMETER DR-M4/1550 |
|
|
|
Refractive
index or Abbe number ( v d or v e ) can be measured atdifferent
wavelengths ranging from 450 to 1,550nm. This refractometer
digitallys display measurement result of refractive index or
Abbe number on the LCD.This measurement can be achieved by
matching the boundary line withthe intersection point of the
cross hairs This is connectable with digital
printer DP-21(A)
(Optional). |
|
|
| Cat.No. |
1415 |
| Model |
DR-M4/1550 |
| Main
components |
Refractometer,
power supply unit, monochromatic light source
device,
near infrared ray viewer,
Interference filter ( 589nm ) |
| Measurement
range |
Refractive
index
1.4700 to 1.8700 ( at 589nm ) |
| Minimum
indication |
0.0001
in refractive index
0.1 in Abbe number |
| Measurement
accuracy |
±
0.0002 in refractive index ( with the attached
test piece at 589nm ) |
| Wavelength
range |
From 450
to 1,550nm
( with interference filters ) |
Measurement
temperature range |
5 to 50°
C |
| Output
terminal |
For
printer, DP-21(A)(Optional) |
| Power
supply |
AC100 to
240V 50/60Hz |
| Optional |
| Cat.No.3011 |
Digital Printer DP-21(A) |
| RE-16501 |
Interference filter
589nm (D) |
| RE-16502 |
Interference filter 486nm (F) |
| RE-16503 |
Interference filter 656nm (C) |
| RE-16504 |
Interference filter 546nm (e) |
| RE-16505 |
Interference filter 480nm (F') |
| RE-16506 |
Interference filter 644nm (C') |
| RE-16507 |
Interference filter (select one
wavelength) |
| 450nm to 539nm |
| 540nm to 680nm |
| 681nm to 799nm |
| 800nm to 1550nm |
| RE-16511 |
Frame for Interference Filter 589nm,
DR-M2, M4/1550 |
| RE-16512 |
Frame for Interference Filter 486nm,
DR-M2, M4/1550 |
| RE-16513 |
Frame for Interference Filter 656nm,
DR-M2, M4/1550 |
| RE-16514 |
Frame for Interference Filter 546nm,
DR-M2, M4/1550 |
| RE-16515 |
Frame for Interference Filter 486nm,
DR-M2, M4/1550 |
| RE-16516 |
Frame for Interference Filter 644nm,
DR-M2, M4/1550 |
| RE-16517 |
Frame for Interference Filter of
Optional, DR-M2, M4/1550 |
| RE-9115 |
Near-infrared ray viewer (with
Adaptor) |
|
| Parts |
| RE-1640 |
Main & secondary prism for
DR-M4/1550 |
| RE-1592 |
Pack of desiccant tablets |
|
| Dimensions
and weight |
Refractometer
13x29x31cm, 6.0kg
Power supply unit 15x33x11cm, 3.0kg |
|
|
 |
DIGITAL
PRINTER DP-21 ( A ) |
|
| The
DP-21 ( A ) is a printer for Digital Refractometer
DBX-55A,Multi-wavelength Abbe Refractometer DR-M2 and DR-M4. It
automatically prints out the number of samples, measurement
results, and measured temperature whenever the refractometer
completes measurement. |
|
|
| Cat.No. |
3011
|
| Model |
DP-21
( A ) |
| Printing
method |
Thermal
dot printing |
| Power
supply |
From AC
adapter ( for the printer ) |
| Power
consumption |
26VA |
| Dimensions
and weight |
14 ( W )
x10 ( D ) x4 ( H ) cm, 390g |
| Parts |
RE-8413
|
Printer paper fo DP-21 |
RE-8415
|
Printer paper for long-term storage
for DP-21 |
|
|
|

|
 |
|