•MULTI-WAVELENGTH ABBE REFRACTOMETERS
MULTI-WAVELENGTH ABBE REFRACTOMETER DR-M2
Refractive index or Abbe number ( v d or v e ) can be measured at different wavelengths ranging from 450 to 1,100nm.
The DR-M2 digitally displays measurement result of refractive index or Abbe number on the LCD.
Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs.
This refractometer is connectable with digital printer DP-21 ( A ) ( Optional ).

Cat.No. 1410
Model DR-M2
Measurement range Wavelength 450nm : Refractive index 1.3277 to 1.7379
Wavelength 589nm : Refractive index 1.3000 to 1.7100
Wavelength 680nm : Refractive index 1.2912 to 1.7011
Wavelength 1,100nm : Refractive index 1.2746 to 1.6843
Minimum indication 0.0001 in refractive index
0.1 in Abbe number
Measurement accuracy ± 0.0002 in refractive index
± 0.1 in Abbe number
Measurement
temperature range
5 to 50° C
Output terminal For printer, DP-21 (A) (Optional)
Power supply AC100 to 240V 50/60Hz
Optional
Cat.No.3011 Digital Printer DP-21 (A)
RE-3520 589nm (D) Interference filter
RE-3521 486nm (F) Interference filter
RE-3522 656nm (C) Interference filter
RE-3523 546nm (e) Interference filter
RE-3524 480nm (F') Interference filter
RE-3525 644nm (C') Interference filter
RE-3526 Interference filter (select one wavelength)
450nm to 539nm
540nm to 680nm
681nm to 799nm
800nm to 1550nm
RE-9115 Near-infrared ray viewer (with Adaptor)

Parts

RE-1600 Main & secondary prism for DR-M2
RE-4170 Illuminating lamp for DR-M2
RE-1592 Pack of desiccant tablets
Dimensions and weight Refractometer 13x29x31cm, 6.0kg
Light source unit 15x33x11cm, 3.0kg
MULTI-WAVELENGTH ABBE REFRACTOMETER DR-M4
Refractive index or Abbe number ( v d or v e ) can be measured at different wavelengths
ranging from 450 to 1,100nm ( For measurement at wavelengths ranging from 681 to 1,100nm, the Optional Near Infrared Ray Viewer ( RE-9115 ) is required. )
The DR-M4 displays measurement result of refractive index or Abbe number digitally on the LCD.
Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs.
This refractometer is connectable with digital printer DP-21 ( A ) ( Optional ) .

Cat.No. 1414
Model DR-M4
Measurement range Wavelength 450nm: Refractive index 1.5164 to 1.9164
Wavelength 589nm: Refractive index 1.4700 to 1.8700
Wavelength 680nm: Refractive index 1.4558 to 1.8557
Wavelength 1,100nm: Refractive index 1.4304 to 1.8303
Minimum indication 0.0001 in refractive index
0.1 in Abbe number
Measurement accuracy ± 0.0002 in refractive index ( with the attached test piece at 500 to 650nm )
Wavelength range From 450 to 1100nm ( with interference filters )
( For measurement at wavelengths ranging from 681 to 1100nm, the Near Infrared Ray Viewer ( Optional ) is required )
Measurement
temperature range
5 to 50° C
Output terminal For printer, DP-21 (A) (Optional)
Power supply AC100 to 240V 50/60Hz
Dimensions and weight Refractometer 13x29x31cm, 6.0kg
Light source unit 15x33x11cm, 3.0kg
Optional
Cat.No.3011 Digital Printer DP-21 (A)
RE-3520 589nm (D) Interference filter
RE-3521 486nm (F) Interference filter
RE-3522 656nm (C) Interference filter
RE-3523 546nm (e) Interference filter
RE-3524 480nm (F') Interference filter
RE-3525 644nm (C') Interference filter
RE-3526 Interference filter (select one wavelength)
450nm to 539nm
540nm to 680nm
681nm to 799nm
800nm to 1550nm
RE-9115 Near-infrared ray viewer (with Adaptor)
Parts
RE-1640 Main & secondary prism for DR-M2
RE-4170 Illuminating lamp for DR-M2
RE-1592 Pack of desiccant tablets
MULTI-WAVELENGTH ABBE REFRACTOMETER DR-M2/1550
Refractive index or Abbe number ( v d or v e ) can be measured at different wavelengths
ranging from 450 to1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD.This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with digital printer DP-21(A)
(Optional).

Cat.No. 1412
Model DR-M2/1550
Main components Refractometer, power supply unit,
monochromatic light source device,
near infrared ray viewer,
Interference filter ( 589nm ) .
Measurement range Refractive index
1.3000 to 1.7100 ( at 589nm )
Minimum indication 0.0001 in refractive index
0.1 in Abbe number
Measurement accuracy ± 0.0002 in refractive index ( with the attached test piece at 589nm )
Wavelength range From 450 to 1,550nm
( with interference filters )
Measurement
temperature range
5 to 50° C
Output terminal For printer, DP-21 (A) (Optional)
Power supply AC100 to 240V 50/60Hz
Optional
Cat.No.3011 Digital Printer DP-21(A)
RE-16501 Interference filter
589nm (D)
RE-16502 Interference filter 486nm (F)
RE-16503 Interference filter 656nm (C)
RE-16504 Interference filter 546nm (e)
RE-16505 Interference filter 480nm (F')
RE-16506 Interference filter 644nm (C')
RE-16507 Interference filter (select one wavelength)
450nm to 539nm
540nm to 680nm
681nm to 799nm
800nm to 1550nm
RE-16511 Frame for Interference Filter 589nm, DR-M2, M4/1550
RE-16512 Frame for Interference Filter 486nm, DR-M2, M4/1550
RE-16513 Frame for Interference Filter 656nm, DR-M2, M4/1550
RE-16514 Frame for Interference Filter 546nm, DR-M2, M4/1550
RE-16515 Frame for Interference Filter 486nm, DR-M2, M4/1550
RE-16516 Frame for Interference Filter 644nm, DR-M2, M4/1550
RE-16517 Frame for Interference Filter of Optional, DR-M2, M4/1550
RE-9115 Near-infrared ray viewer (with Adaptor)
Parts
RE-16500 Main & secondary prism for DR-M2/1550
RE-1592 Pack of desiccant tablets
Dimensions and weight Refractometer 13x29x31cm, 6.0kg
Light Source unit 15x33x11cm, 3.0kg
MULTI-WAVELENGTH ABBE REFRACTOMETER DR-M4/1550
Refractive index or Abbe number ( v d or v e ) can be measured atdifferent wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD.This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with digital printer DP-21(A)
(Optional).

Cat.No. 1415
Model DR-M4/1550
Main components Refractometer, power supply unit, monochromatic light source device,
near infrared ray viewer,
Interference filter ( 589nm )
Measurement range Refractive index
1.4700 to 1.8700 ( at 589nm )
Minimum indication 0.0001 in refractive index
0.1 in Abbe number
Measurement accuracy ± 0.0002 in refractive index ( with the attached test piece at 589nm )
Wavelength range From 450 to 1,550nm
( with interference filters )
Measurement
temperature range
5 to 50° C
Output terminal For printer, DP-21(A)(Optional)
Power supply AC100 to 240V 50/60Hz
Optional
Cat.No.3011 Digital Printer DP-21(A)
RE-16501 Interference filter
589nm (D)
RE-16502 Interference filter 486nm (F)
RE-16503 Interference filter 656nm (C)
RE-16504 Interference filter 546nm (e)
RE-16505 Interference filter 480nm (F')
RE-16506 Interference filter 644nm (C')
RE-16507 Interference filter (select one wavelength)
450nm to 539nm
540nm to 680nm
681nm to 799nm
800nm to 1550nm
RE-16511 Frame for Interference Filter 589nm, DR-M2, M4/1550
RE-16512 Frame for Interference Filter 486nm, DR-M2, M4/1550
RE-16513 Frame for Interference Filter 656nm, DR-M2, M4/1550
RE-16514 Frame for Interference Filter 546nm, DR-M2, M4/1550
RE-16515 Frame for Interference Filter 486nm, DR-M2, M4/1550
RE-16516 Frame for Interference Filter 644nm, DR-M2, M4/1550
RE-16517 Frame for Interference Filter of Optional, DR-M2, M4/1550
RE-9115 Near-infrared ray viewer (with Adaptor)
Parts
RE-1640 Main & secondary prism for DR-M4/1550
RE-1592 Pack of desiccant tablets
Dimensions and weight Refractometer 13x29x31cm, 6.0kg
Power supply unit 15x33x11cm, 3.0kg
DIGITAL PRINTER DP-21 ( A )
The DP-21 ( A ) is a printer for Digital Refractometer DBX-55A,Multi-wavelength Abbe Refractometer DR-M2 and DR-M4. It automatically prints out the number of samples, measurement results, and measured temperature whenever the refractometer completes measurement.

Cat.No.

3011

Model DP-21 ( A )
Printing method Thermal dot printing
Power supply From AC adapter ( for the printer )
Power consumption 26VA
Dimensions and weight 14 ( W ) x10 ( D ) x4 ( H ) cm, 390g
Parts
RE-8413
Printer paper fo DP-21
RE-8415
Printer paper for long-term storage for DP-21

BACK

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117