• Shopping Cart:
  • 0 Items In Cart
  • Total: $0.00
call today

TOLL FREE 1.800.783.6664

Voice: 813.971.5001 Fax : 813.971.5117

sales@omnicontrols.com

 


Prof Dmm W Non-Contact Volt Tester

 




Price starts at $89.95

Product Code : 30XR-A

Manufacturer : Amprobe

Add To Cart Email Friend Add To Saved Cart
For more features and specs on Resistance, Continuity, Diode Test, Battery Test, Overload Protection please click on the Detailed Specs link.

  • Non-contact voltage detector
  • Separate door for easy battery and fuse access
  • Manual Ranging; Display: 3-1/2 digit LCD, 1999 counts
  • Display Update Rate: 2.5/sec, nominal
  • Power Battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
  • Operating Temperature: 0 °C to 45 °C at < 70 % R.H.
  • Storage Temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
  • Low battery indication
  • Overrange indication
  • Min/Max and Data Hold
  F E A T U R E S
Warranty:      One Year
Battery Life:      200 hrs typical (carbon-zinc)
Size:      7.7" x 3.5" x 2.4" (196 x 92 x 60 mm)
Weight:      (Including battery): 0.94 lb (426 gr)
Safety:      Cat II 600V, Cat III 300v
Instruction Manual:      Yes
Detailed Specs:      Yes
Hi-Resolution Image:      Yes

  S P E C I F I C A T I O N S

DC Voltage Ranges:     200 mV, 2 V, 20 V, 200 V, 600 V
DC Voltage Accuracy:     all ranges: ± (1 % rdg + 1 dgt)
DC Voltage Resolution:     100 μV
DC Voltage Input Impedance:     10 MΩ
AC Voltage (45 Hz to 500 Hz) Ranges:     200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) Accuracy:     all ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) Resolution:     100 μV
AC Voltage (45 Hz to 500 Hz) Input Impedance:     10 MΩ
DC Current Ranges:     200 μA, 2 mA, 20 mA, 200 mA, 10 A
DC Current Accuracy:     200 μA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
DC Current Accuracy:     10 A range: ± (2.0 % rdg + 3 dgts)
DC Current Resolution:     0.1 μA
DC Current Voltage Burden (Max):     200 μA range: 1 mV/μA
DC Current Voltage Burden (Max):     2 mA range: 100 mV/1mA
DC Current Voltage Burden (Max):     20 mA range: 13 mV/1 mA
DC Current Voltage Burden (Max):     200 mA range: 4.6 mV/1 mA
DC Current Voltage Burden (Max):     10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz) Ranges:     200 μA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) Accuracy:     200 μA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) Accuracy:     10A range: ± (2.5 % rdg + 4 dgts)
AC Current Resolution:     0.1 μA
AC Current Voltage Burden:     See DC Current
Non-Contact Voltage Detector (NCV) AC Volts:     70 to 600 V ac
Non-Contact Voltage Detector (NCV):     Red LED and Audible Indicator

  O P T I O N A L    A C C E S S O R I E S

Part Number     Description
VC221A Padded vinyl, zipper, belt loop
DL248C Deluxe test lead kit
DC207B Heavy duty case
HV231-10 Specialty handheld tester
TC253A no description
TP254 Higher-temperature immersion probe