• Shopping Cart:
  • 0 Items In Cart
  • Total: $0.00
call today

TOLL FREE 1.800.783.6664

Voice: 813.971.5001 Fax : 813.971.5117

sales@omnicontrols.com

 


Underground Cable and Pipe Locator System

 




Price starts at $6,995.00

Product Code : AT-5005

Manufacturer : Amprobe

Add To Cart Email Friend Add To Saved Cart
  • Model Name Description  
    AT-5005
    • Locates underground energized and de-energized wires, cables and pipes, eliminates exploratory digging in parking lots or under floors for buried pipes and wires
    • New technology makes tracing much faster, accurate and unambiguous when compared to standard locators
    • Three testing modes for best accuracy.
    • Includes receiver (R-5000), transmitter (T-5000), connection cable, ground stake, ground cable, and carrying case and A-Frame
    Included Accessories: AT-5000 receiver and transmitter, A-5000 ground fault locator A-frame attachement

 

  • Locates underground energized and de-energized wires, cables and pipes, eliminates exploratory digging in parking lots or under floors for buried pipes and wires
  • New technology makes tracing much faster, accurate and unambiguous when compared to standard locators:
  • Signal select and distortion alert icon indicates clean signal of the traced line, versus “ghost and ‘return’ path signals coming from the neighboring lines
  • Forward-looking guidance coil alerts for bends and “T
  • Distance sensitive left/right guidance guides the user to the exact location of the buried utilities and eliminates “blind searches for the line
  • Three testing modes for best accuracy:
  • Passive power mode (50, 60, 100 and 120 Hz) – tracing energized lines conducting current
  • Passive radio mode (RF) – using surrounding radio waves to traceunderground object
  • Active mode - T-5000 signal generator with broad frequency selection between 491 Hz and 166 kHz with induction mode or directly connected to the cable with test leads or optional clamp
  • Active mode depth measurement up to 20’ (6m)
  • Bright color ¼ VGA receiver graphical display and audible signal indicators provide clear reading to the user
  • Strong testing signal generated by 10 watt variable output transmitter for dependable depth and distance locating
  • Powerful digital signal processing in both receiver and transmitter provides outstanding performance in tracing when compared to analog devices
  • Automatic or manual gain mode allows respectively quick and easy tracing of the line or precise pinpointing of the fault
  • Receiver Bluetooth® wireless communication for downloading relevant images and archiving of meaningful digital information (previous survey results)
  • Ground fault locating with A-Frame adapter for power and telecom cables (optional for AT-5000)
  • Precise pinpointing of buried services and exceptionally fast sound and meter response
  • Rugged durable construction, weatherproof and drop resistant to 3’
  • Includes receiver (R-5000), transmitter (T-5000), connection cable, ground stake, ground cable, and carrying case and A-Frame
FEATURE AT-5000 AT-3500
Depth measurement 20 ft 16 ft
Passive tracing frequencies 50 Hz, 60 Hz, 100 Hz and 120 Hz 50 Hz / 60 Hz
Transmitter frequency Selectable: 491 to 166 kHz Single, non-adjustable
Receiver active frequencies (Hz) 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America)
491, 512, 577, 640, 982, 8k, 8.44k, 9.82k, 35k, 65.5k, 82k, 83k (Worldwide)
32.768 kHz
Receiver passive frequencies (Hz) 50, 60, 100, 120, RF (14k-21k)
Extended and special frequency sets available
Range 1: radio 15 kHz to 23 kHz
Range 2: power network 50 Hz / 60 Hz;
optionally 100 Hz (can be adjusted by Amprobe service personnel)
Receiver depth display accuracy 0-10 ft: +/- (5 %+2)
under ideal field conditions
10-20 ft: +/- 10%
under ideal field conditions
Range 1: radio +/- 20 %
Range 2: power network +/- 20 %
Range 3: transmitter +/- 5 % (>5m (6-FT)),
+/- 20 % (<5m (15-FT))
Receiver depth range Maximum 20 ft (600 cm) Maximum 16 ft (488 cm)
Receiver antenna (distance sensitive left/right guidance) -
Line ID (signal select, guidance compass, distortion alert) -

Specifications
Depth measurement: 20 ft
Passive tracing frequencies: 50, 60, 100 and 120 Hz
Transmitter frequency: Adjustable from 491 to 166 kHz
A-Frame ground fault locating: Optional
R-5000 Active frequencies (Hz): 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America) 491, 512, 577, 640, 982, 8k, 8.44k, 9.82k, 35k, 65.5k, 82k, 83k
R-5000 Passive frequencies (Hz): 50, 60, 100, 120, RF (14k-21k) extended and special frequency sets available
R-5000 Depth display accuracy: 0-10ft: ±(5%+2) under ideal field conditions 10-20ft: ±10% under ideal field conditions
R-5000 Depth range: Maximum 20ft (600 cm)
R-5000 Battery type: Li-ion rechargeable 9 AA alkaline
R-5000 Antenna: Distance sensitive left/right guidance
R-5000 Dimensions: 8 ¼ W x 13 ¼ H x 29 L (21.0cm x 33.7 cm x 74.3cm)
T-5000 Output frequencies (Hz): 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America) 491, 577, 640, 982, 8.192k, 8.44k, 9.82k, 35k, 82k, 83k Extended and special frequency sets available
T-5000 Output power: Variable to 10W
T-5000 Simultaneous output: Up to three active frequencies
T-5000 Controls: Frequency select, measurement units (mA, Volts, Ohms, Watts), output power, Signal Select™, menu, 4-way navigation, select, SFL, On/Off
T-5000 Display indicators: Battery status, audio volume, output mode, frequency setting, frequency output, % output in SFL or induction mode, output graph, loop resistance graph
T-5000 Display: 1/8 VGA monochrome
T-5000 Battery life: NiMH rechargeable or six (6) D alkaline
T-5000 Dimensions: 11 W x 6 ¾ H x 9 L (27.9 cm x 17.1 cm x 22.9 cm)
T-5000 Regulatory compliance: FCC, CE
T-5000 Environmental: IP54
Included accessories: Receiver (R-5000), transmitter (T-5000), connection cable, ground stake, ground cable, and carrying case



script async src="http://tp.multiview.com/dpx.js?cid=10024&action=100&segment=omnicontrols&m=1">