Digital Panel Meter
|
|
|
|
Price starts at
$159.00
|
|
Product Code : 1000pro
|
|
Manufacturer : Doric
|
|
|
|
|
| Models: |
|
|
|
| Voltage: |
|
|
|
| Options: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
600 Series Ordering
Guide
|
| Base
Model |
Power
Code |
Range
Codes |
Options
Code |
610
612 |
1=
90-132VAC
2=190-262VAC |
-1
(Thermocouple)
-2 (Voltage)
-4 (Current & Loop)
-5 (RTD)
-6 (Thermistor) |
See
600 Series Options List for individual details and codes. |
620
621
622 |
|
-8 (Strain-gage) |
| Examples: |
610-1-1-03
612-2-5-21-21-06-04
621-18
622-1-8-16-03-03-07 |
-
Laboratory
Accuracy to 0.01%
-
Full
5-digit (99999 Counts) Resolution
-
14
Plug-in Options
-
Sensitivity
to 1 Microvolt/Count
-
Simple,
Front Panel Programming
-
Superior
Temperature Measurement
-
Process
Voltage and Current Loop
-
Strain-Gage
Measurement
-
LED
Displayed Engineering Units
-
Made in
USA
|
Click
for 600 Series Manual
A
custom, DORIC-designed, integrating voltage-to-frequency A/D converter
combined with precision filtering, isolated electronics, and
multi-segment digital linearizations lets the Series 600 accommodate
wide measuring ranges at a very high resolution - high enough to achieve
laboratory accuracy in process and test measurements. The Series 600
offers repeatability, reliability, and compatibility with most sensors.
Temperature
can be measured from -460 to +4206°F, -273 to 2318°C, or 0 to 2592K,
all with 0.1° resolution. DC voltage can be measured to 1µV and ranges
are available up to 100V. Process voltage and current loops can easily
be scaled from the front panel, within 99999 display counts. And,
strain-gage indicators measure load cells, pressure, torque, thrust, and
force with 0.01% precision.
Whether
you're measuring the temperature of molten metal or testing jet engine
performance, make your choice a Series 600 digital indicator.
A
Broad Selection of Options
Series
600 instruments offer unparalleled flexibility, allowing you to
configure them specifically for your application. The series has the
industry's widest selection of options. Specify only those options you
need by adding option cards into the instrument's rear slots.
Convenience
From The Front
Just
about everything can be done from the front panel--even calibration.
Simple display instructions prompt you every step of the way. Change
sensor type selection, change °F or °C, set alarm points, or reset
math options-from the front panel. And when an option is installed,
you'll be prompted appropriately.
Also,
all output options are fully isolated, keeping unwanted ground loops
from affecting the instrument's measuring system. This further maintains
the instrument's high accuracy and increases your confidence in the
displayed value.
Unique
Sensor Error Compensation
Compensate
for sensor offset errors with SensorMatch™ - errors like those that
commonly occur with thermocouples. SensorMatch corrects offset errors
inherent in sensors, leadwires, and deviations from reference operating
conditions. Use it to optimize measuring systems at a single measurement
point such as monitoring a calibration bath.
EMI/RFI
Noise Protection
The
Series 600 operates accurately in tough environments where RFI and EMI
can cause problems for other panel indicators. An all-metal case, bezel,
and rear panel isolate the internal electronics from outside
interference.
|
Temperature
Measurement
|
|
The
Series 600 measures and displays as few as one input point or, with
multi-input options, as many as twenty-four. Model 610 is a single input
instrument for rack or panel mounting and can accommodate up to two
option cards. Model 612 is an expanded, double-width indicator that
accommodates up to five options. Both are compatible with a wide
selection of temperature sensors.
Sensor
compatibility is easy to specify because only 3 range cards accommodate
all sensor types. The thermocouple range card accommodates the fourteen
types of thermocouples shown in the range table. The RTD range card
accommodates the six types of RTD sensors. The thermistor range card
accommodates both types of thermistors. They offer 0.1° resolution with
thermocouples and RTD sensors and provide 0.01° to 0.02° resolution
for thermistors.
A
specific sensor type (e.g., type J thermocouple) is keypad selectable
from the front panel. The front panel keypad is also used to select °F,
°C, or Kelvin display units.
Order
Model 610--1 for thermocouple inputs, 610--5 for RTD inputs, 610--6 for
thermistor inputs (Specify up to two option cards, e.g., 610T--______.)
Order
Model 612--X for thermocouple inputs, 612--X for RTD inputs, 612--X for
thermistor inputs (Specify up to five option cards, e.g.,
612--5-___-___-___-___).
NOTE:
" " specifies power: 1 = 115VAC, 2 = 230VAC.
|
RTD
Range Table
|
|
Sensor Type
|
Order Code
|
Range/Display
|
Accuracy(±)
|
Resolution
|
|
Platinum-100
at 0°C
3 or 4-wire, a=0.00385/
Din 43670 curve
|
-5
|
-332°
to +1571°F
-202° to +855°C
70 to 1128 K
|
0.2°F
0.1°C
0.1 K
|
0.1°F
0.1°C
0.1 K
|
|
Platinum-100
at 0°C
3 or 4-wire
a=0.00392
|
-5
|
-401°
to +1572°F
-240° to +855°C
32 to 1128 K
|
0.2°F
0.1°C
0.1 K
|
0.1°F
0.1°C
0.1 K
|
|
Platinum-200
at 0°C
3 or 4-wire
a=0.00392
|
-5
|
-330°
to +1566°F
-201° to +852°C
72 to 1125 K
|
0.2°F
0.1°C
0.1 K
|
0.1°F
0.1°C
0.1 K
|
|
Platinum-1000
at 0°C
3 or 4-wire, a=0.00375/
Hycal, Ultra 7 curve
|
-5
|
-330°
to +1025°F
-204° to +1200°C
68 to 1473 K
|
0.2°F
0.1°C
0.1 K
|
0.1°F
0.1°C
0.1 K
|
|
Copper-10
at 25°C
3 or 4-wire, per
Minco table 16-9
|
-5
|
-337°
to +507°F
-205° to +264°C
68 to 537 K
|
0.8°F
0.4°C
0.4 K
|
0.1°F
0.1°C
0.1 K
|
|
Nickle-120
at 0°C
3 or 4-wire, per
Minco table 7-120
|
-5
|
-112°
to +608°F
-80° to +320°C
192 to 593 K
|
0.4°F
0.2°C
0.2 K
|
0.1°F
0.1°C
0.1 K
|
Thermocouple
Range Table
|
|
Sensor
Type
|
|
Order
Code
|
Range/Display
|
Accuracy(±)
|
Resolution
|
|
Iron-Constantan
|
J
|
-1
|
-336°
to +2193F
-204° to +1200°C
68 to 1473 K
|
0.5°F
0.3°C
0.3 K
|
0.1°F
0.1°C
0.1 K
|
|
Chromel®*-Alumel®*
|
K
|
-1
|
-299°
to +2503F
-184° to +1373°C
88 to 1646 K
|
0.6°F
0.3°C
0.3 K
|
0.1°F
0.1°C
0.1 K
|
|
Copper-Constantan
|
T
|
-1
|
-373°
to +753°F
-225° to +400°C
56 to 1275 K
|
0.4°F
0.3°C
0.3 K
|
0.1°F
0.1°C
0.1 K
|
|
Chromel®*-Constantan
|
E
|
-1
|
-358°
to +1835°F
-217° to +1001°C
56 to 1275 K
|
0.6°F
0.3°C
0.3 K
|
0.1°F
0.1°C
0.1 K
|
|
Platinum-Platinum
13%, Rhodium
|
R
|
-1
|
+32°
to +3219°F
0° to +1770°C
273 to 2043 K
|
1.2°F
(above 79.0°F)
0.7°C
(above 26.0°C)
0.7K
(above 299.2 K)
|
0.1°F
0.1°C
0.1 K
|
|
Platinum-Platinum
10%, Rhodium
|
S
|
-1
|
+32°
to +3216°F
0° to +1769°C
273 to 2042 K
|
1.2°F
(above 79.0°F)
0.7°C
(above 26.0°C)
0.7K
(above 299.2 K)
|
0.1°F
0.1°C
0.1 K
|
|
Platinum
30%,
Rhodium-Platinum
6%, Rhodium
|
B
|
-1
|
+899°
to +3309°F
+481° to +1820°C
755 to 2094 K
|
2.0°F
1.1°C
1.1 K
|
0.1°F
0.1°C
0.1 K
|
|
Nicrosil-Nisil
|
N
|
-1
|
+32°
to +2301°F
0° to +1260°C
273 to 1543 K
|
0.5°F
0.3°C
0.3 K
|
0.1°F
0.1°C
0.1 K
|
|
Tungsten
5%,
Rhenium-Tungsten
26%, Rhenium
|
C
|
-1
|
-10°
to +4200°F
-23° to +2318°C
249 to 2589 K
|
1.1°F
0.6°C
0.6 K
|
0.1°F
0.1°C
0.1 K
|
|
Tungsten-Tungsten
26%, Rhenium
|
G
|
-1
|
+295°
to +4206°F
+146° to +2318°C
419 to 2592 K
|
1.1°F
0.6°C
0.6 K
|
0.1°F
0.1°C
0.1 K
|
|
Tungsten
3%,
Rhenium-Tungsten
25%, Rhenium
|
D
|
-1
|
-8°
to +4203°F
-22° to +2317°C
250 to 2590 K
|
1.1°F
0.6°C
0.6 K
|
0.1°F
0.1°C
0.1 K
|
|
Chromel®*-Gold
.07%, Atomic Iron
|
CGI
|
-1
|
-460°
to +44°F
-273° to +7°C
0 to 280 K
|
0.4°F
0.2°C
0.2 K
|
0.1°F
0.1°C
0.1 K
|
|
Iron
Constantan
DIN
|
FeCon
|
-1
|
-330°
to +1654°F
-201° to +901°C
71 to 1174 K
|
0.9°F
0.2°C
0.5 K
|
0.1°F
0.1°C
0.1 K
|
|
Copper-Constantan
DIN
|
CuCon
|
-1
|
-331°
to +1114°F
-201° to +601°C
71° to 874 K
|
0.9°F
0.5°C
0.5 K
|
0.1F
0.1°C
0.1 K
|
|
*CHROMEL®
and ALUMEL® are registered trademarks of the Hoskins
Manufacturing Company.
|
Thermistor
Range Table
|
|
Sensor
Type
|
Order
Code
|
Range/Display
|
Accuracy
()
|
Resolution
|
|
Thermistor
Series
YSI 400, 225
@25°C
2-wire
|
-6
|
-42°
to +221°F
-41° to +105°C
231 to 458 K
|
0.4°F
0.2°C
0.2 K
|
0.02°F
0.01°C
0.01 K
|
|
Thermistor
Series
YSI 700
3-wire
|
-6
|
+31°
to +213°F
0° to +100°C
272 to 373 K
|
0.4°F
0.2°C
0.2 K
|
0.01°F
0.01°F
0.01 K
|
|
DC
and Scaled DC Measurement and Display
|
|
DC
Voltage. Functioning as a digital voltmeter, the Series 600 provides
precision measurement and display of DC voltages. Four ranges, 100mV,
1V, 10V, and 100V, are standard. Each range is displayed to its highest
resolution within the full 99999 counts of the Series 600 Indicators.
With 0.01% accuracy and 1 digit repeatability, lab quality measurements
are possible with a panel mount indicator.
For
applications demanding more than measurement and display, look to the
Series 600 Options. You can enhance the basic VDC measurement with
multi-input switching, scanning, analog or digital outputs, delta inputs
or math expressions - options that meet the most demanding applications.
Order
Model 610--2 plus up to 2 options; 612--2 plus up to 5 options.
NOTE:
" " specifies power: 1 = 115VAC, 2 = 230VAC.
Scaled
DC Voltage and Current Loop. The Series 600 can accurately measure
and display commonly found process signals to proportional engineering
units. There are three basic configurations to consider when configuring
for your desired input and scaled display.
First,
for current loop measurements, the standard "current" input
card allows selection of either 4-20mA or 10-50mA as its input. Then,
this input is prescaled and displayed to you as 0.00 to 100.00%.
Second,
when you desire to display something other than 0 to 100%, you can add
the scaling and offset options, 600-01. This option allows you to
rescale the display anywhere within ±99999 counts, change the
engineering units, and/or reposition the decimal point location (e.g.,
4-20mA displayed as 0.00 to 560.0 GPM).
Third,
for scaled DC voltages the same scaling and offset option, -SCL, can be
specified for use with the DC Voltage Input Range Card. Any input with
the ranges shown in the DC Voltage Range Table can be scaled, offset,
have engineering units assigned, and/or have decimal position changed
(e.g., 1-5 VDC input can be displayed as 200.0 to 750.0 PSI).
Order
Model 610--4 for current loop inputs as 0-100% and up to 2 options,
612--4-01 for current loop inputs with scaling and up to 5 options,
610--4-01 for current loop inputs with scaling and up to one other
option, 612--4-01 for current loop inputs with scaling and up to four
other options, 610--2-01 for VDC inputs with scaling and up to one other
option, 612--2-01 for VDC inputs with scaling and up to four other
options.
NOTE:
" " specifies power: 1 = 115VAC, 2 = 230VAC.
|
DC
Voltage Range Table
|
|
|
Sensor
Type
|
Order
Code
|
Range/Display**
|
Accuracy(±)*
|
Resolution
|
|
DC mV
|
-2
|
-15.000
to +99.999mV
|
.01%
|
0.001mV
|
|
DC mV
|
-2
|
-150.00
to +999.99mV
|
.01%
|
0.01mV
|
|
DC
Volts
|
-2
|
-1.5000
to +9.9999V
|
.01%
|
0.0001V
|
|
DC
Volts
|
-2
|
-15.000
to +99.999V
|
.01%
|
0.001V
|
|
*
Accuracy percentage is of reading, ±1digit.
*
With order code -2 and Scaling and Offset Option (-01), any input from
-15 to +100V can be scaled to display within
-10000 to ±99999 display counts.
|
Scaled
Range Table
|
|
|
Sensor
Type
|
Order
Code
|
Range/Display**
|
Accuracy(±)*
|
Resolution
|
|
.4-20mA
|
-4
|
0 to
100%
|
.01%
|
0.01%
|
|
10-50mA
|
-4
|
0 to
100%
|
.01%
|
0.01%
|
|
*
Accuracy percentage is of reading, ±1digit.
**
With order code -4 and Scaling and Offset Option (-01), input can be
scaled to display within -10000 to ±99999 display counts.
|
|
|
Digital
Strain-gage Indicators
|
|
The
Series 600 of Digital Strain-gage Indicators is equally compatible with
lower output bonded foil type transducers as with high output
semiconductor transducers (up to 100mV). Each instrument allows
selection from one of four full-scale voltage ranges to optimize
sensitivity.
The
measuring technique used is the unique voltage-to-frequency conversion,
dual slope method with a true, four-wire ratio measurement. This method
assures accurate and stable readings even in noisy environments that can
occur with fluctuating excitation power. Also, it allows for use of
indicators with floating or grounded transducers.
Three
alphanumeric LEDs are supplied either for display of engineering unit
tables (e.g., PSI, KG, LBS) or as "0" for active display of
dead zeros.
Digital
scaling is standard. Drift-free scaling is set to precise engineering
units and decimal location via the instrument's simple, front panel
keyboard entry.
Dual
engineering units (e.g., LBS and KG) are standard. The primary and
secondary engineering unit displays are easily toggled via the front
panel. For example, the primary could be pounds (lbs) while the
secondary, a mathematically proportional kilograms (kg). Because of
their math equivalency, all options function correctly, regardless of
display selection.
System
calibration can be accomplished using a 3-point "live" load,
such as actual weight on a scale, or via electronic instrument
calibration using a DC voltage source.
To
reduce settling indications on the display or option outputs, the
display may be rounded to count by 1, 2, 5, 10, or 100 counts via a
simple program menu selection.
Auto
zero (tare) may be accomplished by the auto zero menu command or while
the process is running. A simple, simultaneous push of the arrow down -
(Ø) and ENT keys rezeros the indicator.
Three
Base Models
There
are three base models of strain-gage indicators from which you can
select. The models vary by their excitation power supply and the
availability of option slots.
The
Model 620 is for a user-supplied, external excitation source. It has
two available option slots.
The
Model 621 includes a built-in excitation supply capable of driving
one or two 350
bridges. Supply voltage is switch selectable for 5, 10, or 15VDC. One
option slot is available.
The
Model 622 includes a higher output built-in excitation supply and,
because it comes in a larger double-width chassis, the ability to add up
to four options. This excitation supply provides 5, 10, 15, or 20VDC
selection with the capability to excite up to eight 350
bridges.
Order
Models 620G--8 for use with external supply and up to two options, 621G
-8 for built-in supply and one option slot, 622g--8 for built-in supply
and four options slots.
NOTE:
" " specifies power: 1 = 115VAC, 2 = 230VAC.
|
Strain-gage
Range Table
|
|
|
Range
|
Order
Code
|
Accuracy(±)*
|
Resolution
|
|
-15mV
to +100mV
|
-8
|
0.01%
|
1µV
per count
|
|
-30mV
to +200mV
|
-8
|
0.01%
|
1µV
per count
|
|
-75mV
to +500mV
|
-8
|
0.01%
|
1µV
per count
|
|
-1500mV
to +1V
|
-8
|
0.01%
|
1µV
per count
|
|
*
Accuracy percentage is of reading, ±1digit.
|
|
|
Series
600 Options
|
|
Tailor
the basic instruments and your applications with options to extend your
measurement capabilities. A complete explanation, any usage
restrictions, and option ordering codes are included in the following
descriptions. Any option can be ordered now or added in the future so
your Series 600 Indicator will never be obsolete.
Available
options slot summary: 610 Models: 2, 612 Models: 5, 620 Model: 2,
621 Model: 1, 622 Model: 4.
Multiple
inputs. Monitor as many as 24 inputs. The first multiple input card
provides an additional five channels of thermocouple or voltage, or two
channels of RTD, or thermistor inputs. Additional cards add six more
thermocouple or voltage, or three more RTD or thermistor inputs. One
card per Model 610 or a maximum of 4 cards per Model 612 instruments.
(This feature is not for use with current loop or strain-gage versions.)
Order Option -21 for 6 input of thermocouple or voltage, -21 for 3
inputs of RTD or thermistor.
Differential
measurement. This card provides an additional input channel and the
capability to display the difference (sT) between the two
channels.
The
-22 option card can be specified with thermocouple and voltage input
models. The -23 option is specifically for use with RTD or thermistor
configurations.
This
function can be combined with other options: maximum, minimum, and
average deltas when used with math capability, scaled analog output of
differentials when used with analog output, and alarm points based on
differential limits (Cannot be used in same indicator with -20 and -21
options. Not for use with current loop or strain-gage versions.) Order
Option -22 for DELTA and 2 thermocouple or voltage inputs, -23 for DELTA
and 2 RTD or thermistor inputs.
Scaling
and offset. Specifically designed for use with voltage and current
loop versions of the 610 and 612, this option provides wide range user
scaling of the display to process units.
With
this option you can rescale and offset inputs for display in direct
engineering units to ±99999 counts. In addition, you can assign
alphanumeric labels or dead zeros to the displayed units.
For
example, 4-20mA could be scaled to display "0.00-255.00 PSI",
"LBS", "KG", "GPM", etc. And it's easy.
Unlike
with other instruments, you need not perform any computations or enter
any formulas. Simply enter upper and lower input and output values. The
Series 600 does the rest, adjusting the optimum slope and offset for you
automatically. (This option is not for use with Models 620, 621, or 622
as digital scaling is included as standard.) Order Option -1
Math
expressions. Provides display of maximum, minimum, rate of change,
or the timed average value of measurements. Front panel keys allow you
to view the math value or switch back to view the actual measured value.
Order Option -04
Alarms.
Each option card provides two alarms with separate limits and relays. Up
to two cards can be specified. Any combination of high, low, or ±
values can be used to trigger the alarm from either actual or math
processed input. Trigger delay and a settable dead-band are included as
standard. Order Option -03 (Up to 2 per instrument.)
DC
power. For automotive, marine, aviation, or plant DC power loops,
the Series 600 can be configured for 12 or 24VDC power operation.
(Cannot be used in Models 621 or 622.) Order Option -10 for 9-16VDC,
-11 for 18-32VDC (One type per instrument.)
Analog
output. For output to recorders or other analog input instruments,
you can choose from two fully isolated linearized and analog outputs.
Both output types, 4-20mA or 0-10VDC, can be fully scaled. Output can be
assigned to direct measurements or math values. Order Option: -06 for
4-20mA, -05 for 0-10VDC
Scanning
Option. The scanning option gives the capability to scan multiple
inputs by working with the multi-input cards in your indicator. This new
option requires no programming; thus, no special menu prompts are given
with this option installed.
The
display readout shows the value of multi-input card channels at a
default rate of 3.4 seconds a channel. The display rate can be made
slower (6.8 sec) - refer to the configuration instructions to change the
rate of display.
It is
recommended that the scanning option not be used with a communications
option such as serial output, etc., since measurement data cannot be
identified as discrete channels. Order Option: -31
|
Digital
Outputs
|
|
Three
digital output modes are available for output to digital equipment.
Serial
output. RS232C or 20mA interface sends display information in serial
ASCII format. Includes user-selectable transmission rates from 300 to
9600 baud, line feed, and carriage return. Order Option -07
IEEE-488
output. For integrating IEEE-488 Bus based measurement or analytical
systems. Main indicator and other options can be programmed via the
IEE-488 Bus. Order Option -08
Series
600 accessories. The Rack Adapter Plate permits mounting of the
Series 600 instruments in a standard 19" (48.2cm) instrument rack.
Different versions have cutouts for 1, 2, or 3 indicators.
Order
Accessory -RKM1 for 1 cutout for Models 610, 620, or 621; -RKM2 for 2
cutouts for Models 610, 620, or 621; -RKM3 for 3 cutouts for Models 610,
620, or 621; -RKD1 for 1 cutout for Models 612 or 622.
|
Model
600 Series General Specifications
|
Repeatability
±1 digit
Stability with Ambient Temperature
Zero: 0.5µV/°C
Span: 0.005% rdg/°C
Reference Junction automatic built-in,
0.018°/° for 0°-50°C J, K, T, E, N, C,
G, D, CGI,FeCon, and CuCon thermocouples
For R, S, and B thermocouples: 0.03°/°
Noise Rejection
NMRR: 60dB at 50Hz or 60Hz ±0.1Hz
CMRR: 120dB at 50Hz or 60Hz ±0.1Hz
Overload Protection
Power lead to ground: 1500VDC or VAC RMS
Input to ground: 270VDC or VAC RMS
Across inputs: 270VDC or VAC RMS continuous
4-20mA range: 80mA
10-50mA range: 200mA
Input Impedance
Thermocouples: 22M (with 20nA of break
detect current)
RTDs: I1 to VinLo (10M ),
12 to VinLo (12.3K ),
depending on range VinHi to VinLo (500M )
Thermistors: I1 to VinHi (3.2K ),
I1-12, (9.45K )
Voltage: 10M to 500M depending on range
Current: <15
Strain-gage: 10M to 500M depending on range
Environmental Ranges
Operating: 0° to 50°C
Storage: -40° to +65°C
Humidity: 90%RH noncondensing
Display
8 digits, 14-segment alphanumeric red LEDs
0.54" (13.7mm) H.
Also one negative ("-") LED at left of array
Input Connections
Sensors: screw terminal blocks
Multi-input: quick connect
AC power: plug-in
DC power: screw terminal blocks
Alarms Option
2 alarm settings per alarm option -
up to 2 alarm options per instrument,
Form C relay output (1A at 120VAC) reset
auto, manual, remote, and override selectable
alarm delay and deadband
Multi-input Options -20 and -21 Accuracy
Thermocouple: ±10µV to ±70µV depending on
T/C type and measurement point
RTD:
Cu10: ±10m
All others: ±50m
Current loop and thermistor: no effect
Point Update Rate
2 readings per second,
1 reading/second for R, S, B, C, G, D,
and CGI thermocouples
Linearization, Temperature Inputs
100% digital, using variable length,
second-order, polynomial segments
Program Storage
EEROM
Case Construction
Metal, black anodized, extruded aluminum
Reliability
40,000 hours MTBF
Installation
Panel mounting from front, secured at sides
by rail clamps supplied with each indicator
Size (H x W x D)
Single-wide Models 610, 620, 621
Case: 2.63" x 5.34" x 9.87"
(6.7cm x 13.6cm x 25cm)
Bezel: 2.84" x 5.67" (7.2cm x 14.4cm)
Panel cutout: 2.68" x 5.44" (6.8cm x 13.8cm)
Double wide Models 612, 622
Case: 2.63" x 10.69" x 9.87"
(6.7cm x 27.2cm x 25cm)
Bezel: 2.84" x 11.01" (7.2cm x 28.cm)
Panel cutout: 2.68" x 10.79" (6.8cm x 27.4cm)
Weight
Single-wide: 4 lbs (1800 g)
Double-wide: 6 lbs (2800 g) without options
Power
AC power, 90V to 132V: 48Hz to 400Hz,
190V to 262 V: 48Hz to 400Hz,
8.0W typical (without options)
detachable 6-foot (1.8m) power cord is supplied,
two detachable 6-foot power cords are supplied
with Model 622
Excitation Supply
Model 621: 5, 10, and 15 volts, switch selectable
isolated, will drive two parallel 350
strain-gages at 15V (90mA)
Model 622: 5, 10, 15, and 20 volts, switch selectable,
isolated, will drive eight parallel 350
strain-gages at 15V (350mA)
Warranty
1 Year
|
600
Series Ordering Guide
|
|
Base
Model
|
Power
Code
|
Range
Codes
|
Options
Code
|
|
610
612
|
1=
90-132VAC
2=190-262VAC
|
-1
(Thermocouple)
-2 (Voltage)
-4 (Current & Loop)
-5 (RTD)
-6 (Thermistor)
|
See
600 Series Options List for individual details and codes.
|
|
620
621
622
|
|
-8 (Strain-gage)
|
|
Examples:
|
610-1-1-03
612-2-5-21-21-06-04
621-18