PosiTector 6000 Series Probes
|
|
|
|
Price starts at
$445.00
|
|
Product Code : PT-6000-Probe
|
|
Manufacturer : DeFelsko
|
|
|
|
|
| Non-Magnetic Coatings on Ferrous metals: |
|
|
|
| Non-Conductive Coatings on Non-ferrous Metals: |
|
|
|
| Both: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
All Separate Probes are interchangeable
"Regular separate probes are suitable for underwater use, i.e. FS1, FNS1, etc |
| Probe Details:
Several probe configurations are available for measuring a wide variety of
coating thickness application. | |
 |
Selection Note:
F - for
ferrous metals (i.e. FS) N - for non-ferrous metals (i.e.
PosiTector 6000 NS) FN - for all metal
substrates (i.e. PosiTector 6000 FNS) |
Built-in probes
|
|
Gage Models: |
F1, F2, F3 |
N1, N2, N3 |
FN1, FN2, FN3 |
FT1, FT2, FT3 |
|
|
|
Range: |
0 - 60 mils |
0 -250 mils |
| 0 - 1500
um |
0 - 6 mm |
|
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2
mils
+ (0.1 mils + 1%) > 2
mils |
+
(0.5 mils + 1%)
0 - 100 mils + (0.5 mil
+ 3%) > 100
mils |
+ (1 um + 1%) 0 - 50
um + (2 um +
1%) > 50
um |
+ (0.01 mm
+ 1%) 0 -
2.5 mm +
(0.01 mm + 3%) >
2.5 mm |
| *Accuracies are stated as a fixed value
plus a percentage of the gage's actual reading. |
Separate Regular Probes
|
|
Probe Models: |
FS |
NS |
FNS |
NAS |
FTS |
|
|
|
Range: |
0 - 60 mils |
0 -25 mils |
0 -250 mils |
| 0 - 1500
um |
0 - 625 um |
0 - 6 mm |
|
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2
mils
+ (0.1 mils + 1%) > 2
mils |
+ (0.02 mils + 1%) 0 - 4
mils + (0.1
mils + 3%)
> 4 mils |
+
(0.5 mils + 1%)
0 - 100 mils + (0.5 mil
+ 3%) > 100
mils |
+ (1 um + 1%) 0 - 50
um + (2 um +
1%) > 50
um |
+ (.5 um + 1%) 0 - 100
um + (2 um +
3%) >
100 um |
+ (0.01 mm
+ 1%) 0 -
2.5 mm +
(0.01 mm + 3%) >
2.5 mm |
| *Accuracies are stated as a fixed value
plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
FRS |
NRS |
FNRS |
|
|
|
Range: |
0 - 60 mils |
| 0 - 1500
um |
|
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2
mils
+ (0.1 mils + 1%) > 2
mils |
+ (1 um + 1%) 0 - 50
um + (2 um +
1%) > 50
um |
| *Accuracies are stated as a fixed value
plus a percentage of the gage's actual reading. |
Separate Microprobes
|
|
Probe Models: |
F0S |
N0S
|
|
|
|
Range: |
0 - 25 mils |
| 0 - 625
um |
|
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4
mils + (0.1
mils + 3%)
> 4 mils |
+ (.5 um + 1%) 0 - 100
um + (2 um +
3%) >
100 um |
| *Accuracies are stated as a fixed value
plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
F45S |
N45S
|
|
|
|
Range: |
0 - 25 mils |
| 0 - 625
um |
|
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4
mils + (0.1
mils + 3%)
> 4 mils |
+ (.5 um + 1%) 0 - 100
um + (2 um +
3%) >
100 um |
| *Accuracies are stated as a fixed value
plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
F90S |
N90S
|
|
|
|
Range: |
0 - 25 mils |
| 0 - 625
um |
|
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4
mils + (0.1
mils + 3%)
> 4 mils |
+ (.5 um + 1%) 0 - 100
um + (2 um +
3%) >
100 um |
| *Accuracies are stated as a fixed value
plus a percentage of the gage's actual reading. |
Separate High-Range Probes
|
|
Probe
Models: |
FNTS
|
FKS |
NKS |
|
|
|
Range: |
0 -250 mils |
0 -500 mils |
| 0 - 6
mm |
0 - 13
mm |
|
Accuracy*: |
+ (0.5 mils + 1%) 0 - 100
mils + (0.5 mil
+ 3%) > 100
mils |
+ (1 mils + 3%) 0 - 500
mils + (0.02 mm
+ 3%) 0 - 13
mm |
|
+ (0.01 mm
+ 1%) 0 -
2.5 mm +
(0.01 mm + 3%) >
2.5 mm |
| *Accuracies are stated as a fixed value
plus a percentage of the gage's actual reading. |
|
|
|
|
|
|