Rotronic Probes
|
|
|
|
Price starts at
$875.00
|
|
Product Code : HygroClip2 Probes
|
|
Manufacturer : Rotronic
|
|
|
|
|
| HygroClip2 Probes: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HygroPalm HP22: Probe Options
|
|
| HC2-S:
measurement in ambient air |
 |
-
Humidity
measuring range: 0…100 %RH
-
Temperature
limits -40…100 °C (-40…212 °F)
-
Diameter:
15mm (0.6”), length: 85 mm (3.3”)
-
Housing
and filter cap: polycarbonate, black
-
Standard
dust filter: NSP-PCB-PE (Polyethylene)
-
Weight:
approx. 10 g (0.35 oz)
|
| HC2-P05:
measurement in air ducts |
 |
-
Humidity
measuring range: 0…100 %RH
-
Temperature
limits -40…85 °C (-40…185 °F)
-
Barrel:
diameter: 5 mm (0.2”), length: 200 mm (7.9”)
-
Probe
cable length: 2 m (6.5 ft)
-
Handgrip:
POM, black - barrel: stainless steel
-
Weight:
approx. 160 g (5.6 oz)
|
| HC2-C04:
measurement in tight spaces |
 |
-
Humidity
measuring range: 0…100 %RH
-
Temperature
limits -40…100 °C (-40…212 °F)
-
Diameter:
4 mm (0.16”), cable length (electronics – probe tip: about 2 m
(6.5 ft)
-
Probe
body: polycarbonate, black
- Weight: approx. 150 g
(5.3 oz)
|
| HC2-C05:
measurement in tight spaces |
 |
-
Same
as HC2-C05 but with 5 mm diameter (0.2”)
-
Can
be equipped with PTFE dust filter SP-T05 (see Accessories)
-
Weight:
approx. 160 g (5.6 oz)
|
| HC2-HK25
/ HC2-HK40: air probe for measurement at temperature extremes |
 |
-
Humidity
measuring range: 0…100 %RH
-
Temperature
limits at sensor:
HK25: -100…150 °C (-148…302 °F)
HK40: -100…200 °C (-148…392 °F)
-
Barrel:
HK25: diameter: 15 mm (0.6”), length: 250 mm (9.8”)
HK40: diameter: 15 mm (0.6”), length: 400 mm (15.7”)
-
Probe
cable length: 2 m (6.5 ft)
-
Handgrip:
POM, black -, barrel: PPS, black
-
Filter
base (NSP-ME) with wire mesh filter cartridge (SP-M15)
- Weight:
HK25: approx. 210 g (7.4 oz)
HK40: approx. 240 g (8.5 oz)
|
| HC2-HP28
/ HC2-HP50: measurement of materials in bulk |
 |
-
Humidity
measuring range: 0…100 %RH
-
Temperature
limits at sensor -40…85 °C (-40…185 °F)
-
Barrel:
HP28: diameter: 10 mm (0.4”), length: 280 mm (11.0”)
HP50: diameter: 10 mm (0.4”), length: 500 mm (19.7”)
-
Probe
cable length: 2 m (6.5 ft)
-
Handgrip:
POM, black - barrel: stainless steel
-
Filter
base (NSP-ME) and sintered steel filter cartridge (SP-S15)
-
Weight:
HP28: approx. 200 g (7.1 oz)
HP50: approx. 250 g (8.8 oz)
|
| HC2-HS28
/ HC2-HS42: measurement of paper stacks and rolls |
 |
-
Humidity
measuring range: 0…100 %RH
-
Temperature
limits at sensor -40…85 °C (-40…185 °F)
-
Blade
HS28: thickness: 4 mm (0.16”), width: 22 mm (0.87”), length: 280
mm (11.0”)
HS42: thickness: 4 mm (0.16”), width: 22 mm (0.87”), length: 420
mm (16.5”)
-
Probe
cable length: 2 m (6.5 ft)
-
Handgrip:
POM, black - blade: aluminum
-
Weight
HS28:: approx. 240 g (8.5 oz)
HS42: approx. 300 g (10.6 oz)
|
|
|
|
|
|