  • Bandwidth DC up to 50 MHz
  • Nominal current 30 A
  • Max. current 50 A, < 10 s
  • Automatic zero adjustment and degauss functions
  • Overheating and Head Unlocked warning
  • Rise time < 7 ns
  • External magnetic field rejection rate AC and DC 60 dB
  • Rejection rate of fast dv/dt (5kV/_s) < 15 mA t
Electrical Characteristics
Nominal current (In)
 ± 30 A dc or A rms
Measuring range (duration <10 sec)
 I max ±50 A pk
Output Sensitivity
 low range 1 V/A (1 MΩ)
 High range 100 mV/A (1 MΩ)
Overall accuracy (dc to 100 Hz at 25 °C)
 ± 0.5 % at In typical
 ± 1.5 % at I max
Gain variation (max)
 ± 0.04 % of rdg/ °C
Step response
 in Data Sheet
Frequency response
 in Data Sheet
Insertion impedance (ZI)
 in Data Sheet
 < 0.1 Ω up to 10 MHz
 < 0.4 Ω 10 MHz to 50 MHz
External magnetic field rejection rate
 60 dB (ac and dc)
Rejection rate of fast dV/dt at 5 kV/ μs
 < 15 m At (during dV/dt)
Output noise level (measured with a filter at 25 MHz)
 1 m At rms typical
Output noise level (measured with a filter at 25 MHz)
 9 mA tpp

 

Dynamic Characteristics
Bandwidth
 DC to 50MHz(-3dB)
Frequency derating (see Figure 4)
 10 A at 10MHz
Rise time, (10 % to 90 %)
 tr < 7ns
Delay time
 td < 25 ns
Overshoot
 < 5 % of reading

 

General Characteristics
Aperture dimensions
 5 x 5 mm (0.2 in x 0.2 in)
Max primary conductor temp
 60 ° C (140 °F)
Dielectric withstand
 1350 Vrms / 50 Hz / 1 min
Working Voltage
 300 Vrms or DC (CAT I)
 150 Vrms or DC (CAT II)
Operating temperature
 °C to + 40 °C (32 °F to 104 °F)
Storage temperature
 -10 °C to + 60 °C (14 °F to 140 °F)
Maximum Altitude
 2000 m (6600 ft)
Maximum relative humidity
 80 % , 31 °C (87 °F)
Environment
 indoor use only
Power supply
 ± 12 V ± 0.5 V
Current consumption at nominal
 30 A 550 mA
Current consumption during demagnetization
 1.3 A (for 6 sec) Probe
Output cable length
 2 m (6.6 ft)