<%@ Register TagPrefix="uc1" TagName="TopSubBanner" Src="CommonControls/TopSubBanner.ascx" %>
<%@ Register TagPrefix="uc1" TagName="TopBanner" Src="CommonControls/TopBanner.ascx" %>
<%@ Register TagPrefix="uc1" TagName="Instruction" Src="CommonControls/Instruction.ascx" %>
<%@ Register TagPrefix="uc1" TagName="LeftColumnNav" Src="CommonControls/LeftColumnNav.ascx" %>
<%@ Register TagPrefix="uc1" TagName="Footer" Src="CommonControls/Footer.ascx" %>
<%@ Register TagPrefix="uc1" TagName="RightColumnNav" Src="CommonControls/RightColumnNav.ascx" %>
<%@ Page Language="vb" AutoEventWireup="false" Codebehind="default.aspx.vb" Inherits="StoreFront.StoreFront.DefaultPage" EnableViewState=True TargetSchema="http://schemas.microsoft.com/intellisense/nav4-0"%>
Dwyer Instruments : Fluke : Calibrators : Thermometers : Valves : Data Loggers : OMNI Controls Online
<%
'@BEGINVERSIONINFO
'@APPVERSION: 6.0.1.0
'@STARTCOPYRIGHT
'The contents of this file are protected under the United States
'copyright laws and is confidential and proprietary to
'LaGarde, Incorporated. Its use or disclosure in whole or in part without the
'expressed written permission of LaGarde, Incorporated is expressly prohibited.
'
'(c) Copyright 2002 by LaGarde, Incorporated. All rights reserved.
'@ENDCOPYRIGHT
'@ENDVERSIONINFO
%>
<% Me.PageHeader %>
General Specifications:
- HL20: records up to 20,000 pairs
of relative humidity and temperature values
- HL21: records up to 20,000 pairs
of temperature values
- Non-volatile EEPROM memory
- Internal sensors (no apparent
probe). Temperature is measured with a Pt100 RTD. Relative
humidity is measured with a ROTRONIC Hygromer IN1 capacitive
sensor.
- Humidity range: 0 to 100 %RH
(non condensing)
- Temperature range: -10 to 60°C
(14 to 140°F) - models with LC display: 0 to 50°C (32 to 122°F)
- Accuracy at 23 °C: ± 0.8 %RH
and 0.1 °C
Interface & Display
- Function key: starts and stops
data logging, turns optional LC display on and off
- Optional LC display with
backlight (values, message bar and battery charge indicator)
- Connector for data download,
configuration and log function programming
Required Accessories
- PC with the ROTRONIC HW4
software installed (version 2.4.0 or higher)
- Cable AC3006 (plugs into a USB
port of the PC)
Power
- 3 x AA batteries (1.5V)
- Up to 20 months of data
recording without replacing the batteries.
Other Features
- English or metric unit system
- Real time clock powered for up
to 4 hours without batteries
- Programmable alarm function
(out-of-limit value)
- Automatic sensor failure alarm
- Status indicator (green and red
LED). The green side of the LED flashes every 5 seconds when
logging is active. The red side of the LED flashes every 5
seconds when a measured value is out of limits or when the
logger requires attention (low battery, memory full, major
sensor failure – such as open or shorted sensor)
- Display Sleep function:
substantially extends the lifetime of the battery
- Simulator function (fixed output
signals) for validating the recording function
- HL20: can be set compute and
display the dew or frost point