With true-rms ac voltage and current measurements, the Fluke 375 Clamp Meter
can ready up to 600 V and 600 A in both ac and dc modes, and is capable of
frequency measurement up to 500 Hz. Additionally, the 375 is compatible with the
new iFlex flexible current probe (sold separately), which expands the
measurement range to 2500 A ac.
Safety Conformance
EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV
Features and benefits
|
- Wireless technology allows the display
to be carried up to 30 ft. away from the point of measurement for
added flexibility without interference with measurement accuracy
- The removable magnetic display can be
conveniently mounted where it is easily seen
- iFlex flexible current probe expands the
measurement range to 2500 A ac
- CAT IV 600 V, CAT III 1000 V
- Integrated low pass filter and state of
the art signal processing allows for use in noisy electrical
environments while providing stable readings
- Proprietary inrush measurement
technology to filter out noise and capture motor starting current
exactly as the circuit protection sees it
- Ergonomic design fits in your hand and
can be used while wearing protective equipment
- Radio transmitter automatically sets the
correct measurement range so you do not need to change the switch
positions while taking a measurement
- Three-year warranty
- Soft carrying case
|
|
Safety conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV

|
What’s the difference between the clamp
meter models?
| |
Fluke-365 |
Fluke-373 |
Fluke-374 |
Fluke-375 |
Fluke-376 |
Fluke-381 |
| Measure ac current |
200.0 A |
600.0 A |
600.0 A |
600.0 A |
999.9 A |
999.9 A |
| Measure ac current
via iFlex |
|
|
2500 A |
2500 A |
2500 A |
2500 A |
| Measure ac voltage |
600.0 V |
600.0 V |
600.0 V |
600.0 V |
600.0 V |
600.0 V |
| Measure continuity |
≤ 30 Ω |
≤ 30 Ω |
≤ 30 Ω |
≤ 30 Ω |
≤ 30 Ω |
≤ 30 Ω |
| Measure dc voltage |
200.0 A |
|
600.0 A |
600.0 A |
999.9 A |
999.9 A |
| Measure dc voltage |
600.0 V |
600.0 V |
600.0 V |
600.0 V |
600.0 V |
600.0 V |
| Measure resistance |
6,000 Ω |
6,000 Ω |
6,000 Ω |
60k Ω |
60k Ω |
60k Ω |
| Measure frequency |
|
|
|
500 Hz |
500 Hz |
500 Hz |
| Measure inrush |
|
|
100 mS |
100 mS |
100 mS |
100 mS |
| Work in poorly lit
areas |
Backlight |
Backlight |
Backlight |
Backlight |
Backlight |
Backlight |
| Measure non-linear
loads |
True-rms |
True-rms |
True-rms |
True-rms |
True-rms |
True-rms |
| Specifications |
| Diameter of measurable
conductor |
01.26” or 32 mm max |
| Operating temperature |
-14 to 122ºF (-10 to 50ºC) |
| Storage Temperature |
-40 to 140ºF (-40 to 60ºC) |
| Operating Humidity |
< 90% @ 10 to 30 ºC, < 75% @ 30 to 40ºC |
| Operating Altitude |
0 to 3000 m |
| Size |
232 x 85 x 45 mm, (9.133 x 3.346 x 1.771
in.) |
| Weight |
370g, (13 oz.) |
| Temperature Coefficient |
0.01% ºC
(<18ºC or > 28ºC) |
| Warranty |
Three years for electronics