Fluke IR Thermal Imaging Camera
|
|
|
|
Price starts at
$23,790.00
|
|
Product Code : FLK-TI50FT-20/54
|
|
Manufacturer : Fluke
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Specifications
(PDF)
The professional’s
choice when demanding the highest sensitivity
Choose the Fluke Ti5x models when you need the best
images. They feature 320 x 240 detectors with industry leading thermal
sensitivity (≤ 0.05 °C;50 mK NETD)
for high resolution, ultra high-quality
images. In addition, with a 60 Hz detector acquisition rate temperatures are
displayed live on the large 5-inch color display.
All FT models feature the innovative IR-Fusion®
technology. IR-Fusion captures a visible light image in addition to the infrared
image and takes the mystery out of IR
image analysis. It helps to better
identify and report suspect components and enable the repair to be done right
the first time. To find out more select IR-Fusion on the
side navigation of this
page.
Typical applications
- Predictive maintenance – Identify electrical and mechanical problems before
they cause failure
- Power/utilities – Real-time analysis of substations, transmission lines and
equipment
- Process monitoring – Real-time observation to ensure efficient and safe
operation
- Research and development – Quantify heat patterns to improve product designs
- Electronic design – Close up circuit board analysis
|
| Fluke
Ti50FT and Ti55FT IR FlexCam® Thermal Imagers with IR-Fusion® Technology |
 |
 |
| Fluke
IR-Fusion Technology |
| Infrared
and Visible light images are fused together - enabling you
to view images in a range of modes from full IR to full
visible light, and see exactly what you are viewing. |
 |
| To
find out more select "IR Fusion" in the side
navigation of this page. |
|
See exactly
what you are viewing
Fluke IR-Fusion® technology links a real world
visual image with a thermal image. It merges the two images into one, with
the possibility to blend between the two images or create
picture-in-picture combinations. Alarm limits can be superimposed over the
visible light image to exactly pinpoint the components exceeding a
specified temperature limit. Both the visual images and thermal images are
available for use in reports. This speeds up documentation by reducing the
need to look for individual images taken with a separate digital camera.
IR Fusion helps to better identify and report suspect components and
enable the repair to be done right the first time.
Large,
sharp thermal images
Thanks to the largest display (five-inch)
available on this type of thermal imager in combination with low-noise VOx
sensors, the Fluke IR FlexCam units produce exceptionally high-quality
images making even the smallest temperature differences visible. This is
comparable with images normally only obtained on far more expensive
instruments.
A sharp
image in every situation
The innovative 180 ° articulating lens makes
it possible to view and capture images in areas with poor accessibility.
The display remains clearly visible while viewing over high objects, under
a machine or around immoveable obstructions. The SmartFocus wheel
simplifies getting a stable and sharp image. No need to take your hand off
the instrument to turn a focus ring.
Make
anomalies visible
Thanks to built-in functions like AutoCapture,
the IR FlexCam Thermal Imagers help to troubleshoot difficult problems.
The instrument is easily set up to automatically capture only those images
where a temperature limit is exceeded. This way, difficult to find
intermittent problems can be captured and analyzed quicker by
concentrating only on the images containing the anomalies.
Analysis
and reporting comes standard
The SmartView™ software (supplied with the
unit) includes a complete range of infrared image viewing, analysis,
annotation and reporting tools. It even allows for customized reports to
accommodate specific company work processes or requirements like multiple
image reporting and comparisons. To find out more select SmartView on the
side navigation of this page.
Radiometric
measurement – the ‘data behind the picture’
Fully radiometric thermal imagers capture and
store calibrated temperature data for the matrix of thousands of points
that make up a thermal image. This makes it possible to perform detailed
analysis and change key parameters like emissivity or temperature range
either in the field on the camera or in the office using the PC software.
| |
Ti55FT |
Ti50FT |
| High
resolution, low noise VOx detector for high quality images |
320
x 240 |
| Temperature
range to cover broad industrial applications |
-20
to +600 ºC (-4 to 1112 ºF) |
-20
to +350 ºC (-4 to 662 ºF) |
| High
thermal sensitivity for viewing even the smallest temperature
differences |
≤0.05
ºC |
≤0.07
ºC |
| 180º
articulating flexible lens to view images in every situation |
• |
• |
| Choice
of 3 interchangeable lenses to cover every application |
• |
• |
| Large
5" high contrast color LCD for a clear picture independent of
lighting conditions |
• |
• |
| Fully
radiometric for detailed temperature analysis and tracking |
• |
• |
| SmartFocus
for best image quality and accurate temperature measurements |
• |
• |
| Windows®
CE based menu structure for ease of use |
• |
• |
| Personalized
instrument set-up for multiple use |
• |
• |
| CompactFlash
memory cards to store over 1000 IR images plus fully radiometric
temperature data |
• |
• |
| SmartView
reporting and analysis software included |
• |
• |
| AutoCapture
for making intermittent problems visible |
• |
|
| On-board
analysis functions |
• |
|
| User
defined text annotations for simplified reporting |
• |
|
| Built-in
visible light (digital) camera |
• |
• |
| IR/Visible
Alarm function |
• |
|
| Laser
pointer for easy targeting |
• |
• |
| Flash
and torch light for high quality images in dark environments |
• |
• |
|
| Fluke
Ti50FT and Ti55FT IR FlexCam® Thermal Imagers with IR-Fusion® Technology |
 |
| Specifications |
| Imaging
performance |
| Thermal |
|
| Field
of view (FOV) |
20
mm lens 23° x 17° FOV 10.5 mm lens 42° x 32° 54 mm
lens 9° x 6 ° |
| Spatial
resolution (IFOV)* |
1.30
mrad |
| Min
focus distance* |
0.15
m |
| Thermal
sensitivity (NETD) |
Ti55:
≤ 0.05 °C (50 mK)at 30 °C
Ti50: ≤ 0.07 °C (70 mK) at 30 °C |
| Detector
data acquisition* |
60
Hz |
| Focus |
SmartFocus;
one finger continuous focus |
| IR
digital zoom |
Ti55:
2x, 4x, 8x |
|
Ti50:
2x |
| Detector
type |
320
x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled
Microbolometer with 25 micron pitch |
| Spectral
band |
8
µm to 14 µm |
| Digital
image enhancement |
Automatic
full-time enhanced |
| Visual |
|
| On
camera operating modes |
Full
Thermal, full visual light or merged thermal-visual
images. Picture-in-Picture |
| Visible
light camera |
1280
x 1024 pixels, full color |
| Visible
light digital zoom |
Ti55:
2x, 4x |
|
Ti50:
2x |
|
| Temperature
measurement |
| Calibrated
temperature range |
Ti55:
-20 ˚C to 600 ˚C (-4 to 1112 ºF) in 3 ranges
Ti50: -20 ˚C to 350 ˚C (-4 to 662 ºF) in 2
ranges |
| Range
1 |
Ti55:
-20 ˚C to 100 ˚C (-4 to 212 ºF) |
|
Ti50:
-20 ˚C to 100 ˚C (-4 to 212 ºF) |
| Range
2 |
Ti55:
-20 ˚C to 350 ˚C (-4 to 662 ºF) |
|
Ti50:
-20 ˚C to 350 ˚C (-4 to 662 ºF) |
| Range
3 |
Ti55:
250 ˚C to 600 ˚C (482 to 1112 ºF) |
| Accuracy |
±2
°C or 2 % (whichever is greater) |
| Measurement
modes |
Ti55:
Centerpoint, center box (area min/max, average), moveable
spots/boxes, user defined field/text annotations,
isotherms, automatic hot and cold point detection, visible
color alarm above and below |
|
Ti50:
Centerpoint, center box (area min/max, average) |
| Emissivity
correction |
0.1
to 1.0 (0.01 increments) |
|
| Image
presentation |
| Digital
display |
5"
large high-resolution digital display |
| LCD
backlight |
Sunlight
readable color LCD |
| Video
output |
RS170
EIA/NTSC or CCIR/PAL composite video |
| Palettes |
Grayscale,
grayscale inverted, blue red, high contrast, hot metal,
ironbow, amber, amber inverted |
|
| Optional
lenses (Only available at time of purchase) |
| 54
mm Telephoto lens |
High
precision Germanium lens |
| Field
of view (FOV) |
9
º horizontal x 6 º vertical |
| Spatial
resolution (IFOV) |
0.47
mrad |
| Min
focus distance |
0.6
m |
| 10.5
mm wide angle lens |
High
precision Germanium lens |
| Field
of view (FOV) |
42
º horizontal x 32 º vertical |
| Spatial
resolution (IFOV) |
2.45
mrad |
| Min
focus distance |
0.3
m |
|
| Image
and data storage |
| Storage
medium |
Compact
flash card stores over 1000 IR images (512 MB card
standard) |
| File
formats supported |
14
bit measurement data included. Exportable JPEG, BMP, PCX,
PNG, PSD. |
|
| Interfaces
and software |
| Interface |
Compact
flash card reader included |
| Software |
SmartView;
Full analysis and reporting software included |
|
| Laser |
| Classification |
Class
II |
| Laser
targeting |
Laser
dot visible on screen when blending thermal and visible
image |
|
| Controls
and adjustments |
| Set-up
controls |
Date/time,
temperature units C/F/K, language, scale, LCD intensity
(high/normal/low) |
| Image
controls |
Level,
span, auto adjust (continuous/manual) |
| On-screen
indicators |
Battery
status, target emissivity, background temperature and real
time clock |
|
| Power,
battery life |
| Battery
type |
Li-Ion
smart battery, rechargeable, field-replaceable |
| Battery
operating time |
3
hours continuous operation (2 hours with IR-Fusion
engaged) |
| Battery
charging |
2
bay intelligent charger powered via AC outlet |
| AC
operation |
AC
adapter 110/220 VAC, 50/60 Hz (Ti55 only) |
| Power
saving |
Automatic
shutdown and sleep modes (user specified) |
|
| Environmental
and mechanical design |
| Operating
temperature |
-10
°C to +50 °C (14 °F to 122 °F) |
| Storage
temperature |
-40
°C to +70 °C (-40 °F to 158 °F) |
| Relative
humidity |
Operating
and storage 10 % to 95 %, non-condensing |
| Water
and dust resistant |
IP54 |
| Weight
(including batteries) |
1.95
kg (4.3 lbs) |
| Camera
size (HxWxD) |
162
x 262 x 101 mm (6.5" x 10.5" x 4.0") |
|
| Other |
|
7.5 Hz
models are available in some geographies. Check with your Fluke sales
representative for additional information.
|
Ordering
Information
| FLK-TI50FT-10/20 |
2649238 |
IR
FLXCM THERM IMAGER,320,S F/W,FUSN,10.5/20MM |
| FLK-TI50FT10/20/54 |
2649277 |
IR
FLX THERM IMAGE,320,S F/W,FUSN,10.5/20/54MM |
| FLK-TI50FT-20 |
2649195 |
IR
FLEXCAM THERM IMAGER,320,S F/W,FUSION,20MM |
| FLK-TI50FT-20/54 |
2649250 |
IR
FLXCM THERM IMAGER,320,S F/W,FUSION 20/54MM |
| FLK-TI55FT-10/20 |
2649094 |
IR
FLXCM THERM IMAGER,320,D F/W,FUSN,10.5/20MM |
| FLK-TI55FT10/20/54 |
2649139 |
IR
FLX THERM IMAGE,320,D F/W,FUSN,10.5/20/54MM |
| FLK-TI55FT-20 |
2649053 |
IR
FLXCAM THERM IMAGER,320,DLX F/W,FUSION,20MM |
| FLK-TI55FT-20/54 |
2649117 |
IR
FLEXCAM THERM IMAGER,320,D F/W,FUSN,20/54MM |
| FLK-TI-SBC |
2648355 |
104465,IR
SMART BATTERY CHARGER |
| FLK-TI-SBP |
2648343 |
104464,IR
SMART BATTERY PACK |
|
|
|
|
|
|