• Shopping Cart:
  • 0 Items In Cart
  • Total: $0.00
call today

TOLL FREE 1.800.783.6664

Voice: 813.971.5001 Fax : 813.971.5117

sales@omnicontrols.com

 


Fluke 566 Infrared and Contact Thermometer

 




Price starts at $309.95

Product Code : Fluke-566

Manufacturer : Fluke

Add To Cart Email Friend Add To Saved Cart
In Stock!

Features and benefitsof the Fluke 566:

  • Measure -40 øC to 800 øC /-40 øF to 1472 øF (568) or -40 øC to 650 øC/-40 øF to 1202 øF (566)
  • Easily access advanced features with the soft-key buttons and dot-matrix display
  • Measure smaller objects from further away, with a distance-to-spot ratio of 50:1 (568) or 30:1 (566)
  • Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments
  • Confidently measure a wide variety of surfaces, with the adjustable emissivity feature, including a built-in material table
  • Capture multiple points of data (up to 99 with the 568, and 20 with the 566), for downloading and recalling later
  • Easily adapt to lighting conditions with 2 levels of backlight
  • Audible and visual alarms instantly alert you to measurements outside of your set limits
  • Quickly identify problems with the MIN, MAX, AVG, and DIF functions
  • Make contact thermometer measurements right away with the included Type-K thermocouple bead probe
  • Confidently troubleshoot equipment with 1 % measurement accuracy
  • Versatile interface with 6 languages from which to choose
Product specifications
Infrared temperature range
566: -40 øC to 650 øC (-40 øF to 1202 øF)
Infrared accuracy
< 0 øC (32 øF): ñ (1.0 øC (ñ 2.0 øF) + 0.1ø/1 øC or øF);
> 0 øC (32 øF): ñ 1 % or ñ 1.0 øC (ñ 2.0 øF), whichever is greater
Display resolution
0.1 øC / 0.1 øF
Infrared spectral response
8 æm to 14 æm
Infrared response time
< 500 msec
Thermocouple Type-K input temperature range
-270 øC to 1372 øC (-454 øF to 2501 øF)
Thermocouple Type-K input accuracy
-270øC to -40øC: ñ (1 øC + 0.2 ø/1 øC) (-454 øF to -40 øF: ñ (2 øF + 0.2 ø/1 øF))
-40øC to 1372øC: ñ 1 % or 1 øC (-40 øF to 2501 øF: ñ 1 % or 2 øF), whichever is greater
D:S (distance to measurement spot size)
566: 30:1
Laser sighting
Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size
19 mm (0.75 in)
Emissivity adjustment
By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage with Date/Time stamp
566: 20 points
568: 99 points
PC Interface and cable
566: None
Hi/Low alarms
Audible and two-color visual
Min/Max/Avg/Dif
Yes
Display
Dot matrix 98 x 96 pixels with function menus
Backlight
Two levels, normal and extra bright for darker environments
Trigger lock
Yes
Switchable Celsius and Fahrenheit
Yes
Power
566: 2 AA/LR6 Batteries
Battery life
If used continuously: laser and backlight on,12 hours; laser and backlight off, 100 hours
Operating temperature
0 øC to 50 øC (32 øF to 122 øF)
Storage temperature
-20 øC to 60 øC (-40 øF to 140 øF)
Bead thermocouple Type-K range
-40 øC to 260 øC (-40 øF to 500 øF)
Bead thermocouple Type-K accuracy
ñ 1.1 øC (2.0 øF) from 0 øC to 260 øC (32 øF to 500 øF), typically within 1.1 øC (2.0 øF) from -40 øC to 0 øC (-40 øF to 32 øF)