API Thermocouple Alarms and Conditioners
|
|
|
|
Price starts at
$259.00
|
|
Product Code : API-Thermocouple Transmitters
|
|
Manufacturer : API
|
|
|
|
|
| Models Available: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Thermocouple Input Alarms and Transmitters |
Download pdf with all products on this page
Temperature
Input Alarms and
Temperature Transmitters
Click on model numbers below for data sheets and application information |
Hot-Swappable Plug-In Design
LoopTracker® LEDs
Output Test
Lifetime Warranty |
Reference Info
Common
Thermocouple Sensors
Alarm
Terminology & Deadband
Relay
Protection & EMI Suppression |
| Model |
Input |
Output |
Features |
|
API
1200 G
T/C Input Single Alarm Trip |
Specify T/C
type and
Temperature range
in °F or °C
Factory Configured
Also available in °F
–100-100°C type E
–100-200°C type J, E
0-100°C type J, T, E
0-150°C type J, T, E
0-200°C type J, K, T, E
0-400°C type J, K, T, E
0-500°C type J, K, E
0-600°C type J, K, E
0-700°C type J, K, E
0-800°C type K, E
0-1000°C type K
0-1200°C type K |
1 DPDT 7A
Contact Set
Field Adjustable
Specify Alarm Type
See data sheet for alarm options |
- Hot-Swappable Plug-In Design
- Replaces Action AP1220
- LoopTracker LEDs for Input
- Alarm Status LEDs
- Push to Test/Reset
- Automatic Cold Junction Comp.
- Upscale Burnout Protection
- Uses API-011 11-Pin Socket
- 115 VAC Powered
- A230 option for 230 VAC Power
- D option for 9-30 VDC Power (+$60)
|

 |
API
1220 G
T/C Input Dual Alarm Trip |
2 SPDT 7A
Contact Sets
Field Adjustable
Specify Alarm Type
See data sheet for alarm options |
Sineax
V624
Programmable
Isolated RTD or T/C to DC Transmitter
Microprocessor-Based |
T/C types
J, K, T, E, R, S, N, B, W5, W3, L, U
RTD
2-, 3-, or 4-wire
100 Ω 0.00385α
100 Ω 0.003916α
Thermistor
Custom |
Specify if Current or
Voltage
Output
0-2 mA to
0-20 mA,
20-0 mA,
0-1 V to
0-10 V,
10-0 V |
- PC Programmable
- Reverse Output Programmable
- Custom Input Linearization
- Programmable Sensor Fault Response
- Removable Plugs
- 3.7 kV Input/Output/Power Isolation
- 24-60 or 85-230 VAC/VDC Powered
Instructions
Software |

 |
API
4130 GL
Isolated & Linearized
T/C-DC Transmitter |
Specify T/C type and
Temperature range in °F or °C
Factory Configured
Also available in °F
–100-100°C type E
–100-200°C type J, E
0-100°C type J, T, E
0-150°C type J, T, E
0-200°C type J, K, T, E
0-400°C type J, K, T, E
0-500°C type J, K, E
0-600°C type J, K, E
0-700°C type J, K, E
0-800°C type K, E
0-1000°C type K
0-1200°C type K |
Specify Output Range
Factory Configured
Others available
0-1 V
0-5 V
1-5 V
0-10 V
±5 V
±10 V
0-20 mA
4-20 mA |
- Hot-Swappable Plug-In Design
- T/C Linearization
- Full I/O/Power Isolation
- Direct Replacement for Action AP 4130
- I/O LoopTracker LEDs
- Output Test Button
- Automatic Cold Junction Comp.
- Uses API-008 8-Pin Socket
- 115 VAC Powered
- A230 option for 230 VAC Power
- D option for 9-30 VDC Power (+$60)
|

 |
| Discontinued Products |
| API
4000 G |
RTD or T/C to DC Transmitter. Replaced by the
Sineax V624 |
| API
4100 G |
Non-Isolated T/C-DC Transmitter. Replaced by
the API 4130 GL |
|
|
|
|
|