Simple Logger® II Model L101 2126.02
|
|
|
|
Price starts at
$349.00
|
|
Product Code : L101
|
|
Manufacturer : AEMC
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Specifications
(PDF)
|
L101 AC Current
Loggers
The Simple Logger® II
Model L101 is a one channel recording device powered by an
alkaline battery pack. Line tracking is performed such that 64
samples over one line cycle are taken. Frequency tracking is
performed over the range of ±2Hz around the nominal line
frequency (50 or 60Hz). Harmonic measurements are calculated from
these 64 samples (Harmonics are only available from the Simple
Logger® II Control Panel within the DataView®
software).
The Simple Logger® II records TRMS at a rate of up to
eight times per second. The measurement process is performed no
more than eight times per second. TRMS calculations are performed
on a single line cycle. This means that the input(s) are ignored
between measurement intervals.
The main advantage of the logger is its ability to perform a
variety of recording tasks with easy and intuitive setup from a
computer using DataView® software.
Analog information on the input is sampled and converted to a
digital signal. This digital signal is processed and stored along
with scale and time information. An optically isolated Universal
Serial Bus (USB) port provides for the transfer of data from the
instrument’s internal memory to the computer for analysis. |
| |
Features
- Compatible standard current probes with voltage output and
BNC connection
- 64 samples per cycle
- Programmable storage rates from 8 every second to 1 every
day
- 3 user selectable storage modes
- Stores up to 240,000 measurements in non-volatile memory
- Powered by standard Alkaline batteries
- Lightweight, compact, fits anywhere
- 5 LED indicators quickly and clearly display Logger status
- Includes DataView® software for data storage,
real-time waveform display, analysis and report generation
- Isolated USB communication
- 50V Cat III
|
| |
Applications
- Load profiling
- Fault current detection
- Intermittent problem detection
- Demand recording
- Neutral current monitoring
- Harmonic current recording using DataView®
software
- Metering CT resizing
|
|
|
|
|
|
|