|
|
HI 3893
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
Many parameters affect the well being and growth of
fish in aquaculture and aquariums. Hanna offers a wide range of single and
multi-parameter test kits as well as electronic pocket and portable instruments
to help operators keep all of these parameters under strict control. HI 3893 is
part of Hannas efforts in addressing the needs of operators in these
fields. HI 3893 unifies in one package 4 different tests, namely, ammonia,
nitrate, nitrite and pH. It is an ideal kit for crab and lobster aquariums and
saltwater holding tanks at wholesalers as well as at retail shops. The kit
provides for 50 tests each of pH, nitrite, nitrate and ammonia. All the
apparatus necessary to perform the tests are also included in the package. The
simplicity of the kit and its affordable price make it suitable for specialists
and hobbyists whether technically oriented or not.
|
| Specifications: | Method | Range* | Smallest Increment |
Chemical Method | # of Tests |
| Ammonia | Colorimetric | 0-2.5 mg/L NH3-N | 0.5 mg/L | Nessler | 50 |
| Nitrate | Colorimetric | 0-50 mg/L NO-3-N | 10 mg/L | Cadmium reduction | 50 |
| Nitrite | Colorimetric | 0-1 mg/L NO-2-N | 0.2 mg/L | Sulfanilamide | 50 |
| pH | Colorimetric | 6.0-8.5 pH | 0.5 pH | pH Indicators | 50 |
* 1 mg/L = 1 ppm.
![]() |
HI 98321 and HI 98322 - Waterproof EC/TDS/°C/°F Meters
|
The new HI 98321 & HI 98322 portable meters from Hanna are designed for quick and easy, high accuracy EC, TDS and temperature measurements. These new waterproof instruments have a dual-level LCD that desplays EC or TDS and °C or °F. These microprocessor meters have been developed in direct response to the requests of users in water treatment, boilers and cooling towers, reverse osmosis and agriculture. The rugged, easy-to-use HI 98321 & HI 98322 feature an on board sample cell with built-in funnel, digital readout, push button automatic calibration and automatic temperature compensation. The EC/TDS conversion factor and temperature coefficient (ß) are user adjustable for application-specific measurements.
At startup the HI 98321 & HI 98322 perform a self-check and then display the battery level to assure proper working condition. They also have a stablity indicator and hold feature to prompt the user when to take the reading and freeze the display for easy and acccurate recording.
Choose your meter according to the proper EC / TDS ranges for your application:
HI 98321 & HI 98322 are supplied complete with 4 x 1.5V batteries and instructions.
| Specifications: | HI 98321 | HI 98322 | |
| Range | EC | 0 to 3999 µS/cm | 0.00 to 20.00 mS/cm |
| TDS | 0 to 2000 ppm | 0.00 to 10.00 ppt | |
| Temperature | 0.0 to 60.0 °C or 32.0 to 140.0 °F | ||
| Resolution | EC | 1 µS/cm | 0.01 mS/cm |
| TDS | 1 ppm | 0.01 ppt | |
| Temperature | 0.1 °C or 0.1 °F | ||
| Accuracy (@ 20°C/68°F) | EC | ±2% Full Scale | |
| TDS | ±2% Full Scale | ||
| Temperature | ±0.5 °C or ±1 °F | ||
| Typical EMC Deviation | EC | ±2% Full Scale | |
| TDS | ±2% Full Scale | ||
| Temperature | ±0.5 °C or ±1 °F | ||
| EC / TDS Calibration | Automatic 1 point at 1413 µS/cm |
Automatic 1 point at 12.88 mS/cm |
|
| EC / TDS Conversion Factor | Adjustable from 0.45 to 1.00 | ||
| Temperature Compensation |
Automatic with BETA (ß) = adjustable from 0.0 to 2.4% per °C | ||
| Environment | 0 to 50°C (32 to 122°F); R.H. 100% | ||
| Battery Type / Life | 4 x 1.5V / 2000 hours | ||
| Auto Shut-off | After 8 minutes | ||
| Dimensions | 120 x 53 x 81 mm (4.7 x 2.1 x 3.1") | ||
| Weight | 225 g (7.8 oz.) | ||
![]() |
HI 9835 Waterproof, Autoranging, EC/TDS/NaCl/°C Meter
|
| |
|
The Hanna HI 9835 can measure conductivity, total dissolved solids, NaCl, and temperature, all with one probe. The temperature of all conductivity and TDS measurements is automatically or manually compensated for by the meter's ATC circuitry. The temperature coefficient is user selectable from 0.00 to 6.00 %/°C (for EC and TDS only) and the TDS factor can be set from 0.40 to 0.80.
The meter is constructed with a waterproof, rugged housing which allows the versatility required for both laboratory and field use. Moreover, HI 9835 is equipped with a large LCD that helps the user through operation and calibration with large comprehensive symbols. Besides displaying the measurements, the LCD simultaneously displays the temperature. The display gives a low battery warning and switches itself off after 5 minutes of non-use to save the batteries.
HI 9835 is supplied complete with HI 76309 Conductivity/TDS probe with 3.3' (1 m) screened cable, AA size Alkaline Batteries (4 pcs) and instruction manual in a rugged carrying case.
| Specifications: | HI 9835 | |||
| EC (Autoranging) |
TDS (Autoranging) |
NaCl | Temperature | |
| Range | 00.0 to 29.99 µS/cm 30.0 to 299.9 µS/cm 300 to 2999 µS/cm 3.00 to 29.99 mS/cm 30.0 to 200.0 mS/cm Up to 500.0 mS/cm actual (*) Conductivity |
0.00 to 14.99 ppm 15.0 to 149.9 ppm 150 to 1499 ppm 1.50 to 14.99 g/L 15.0 to 100.0 g/L Up to 400.0 g/L actual (*) TDS (with 0.80 factor) |
0.0 to 400.0 % | 0.0 to 60.0°C |
| Resolution | 0.01 µS/cm (from
0.00 to 29.99 µS/cm) 0.1 µS/cm (from 30.0 to 299.9 µS/cm) 1 µS/cm (from 300 to 2999 µS/cm) 0.01 mS/cm (from 3.00 to 29.99 mS/cm) 0.1 mS/cm (over 30.0 mS/cm) |
0.01 ppm (from 0.00 to
14.99 ppm) 0.1 ppm (from 15.0 to 149.9 ppm) 1 ppm (from 150 to 1499 ppm) 0.01 g/L (from 1.50 to 14.99 g/L) 0.1 g/L (over 15.0 g/L) |
0.1 % | 0.1°C |
| Accuracy (@ 20°C/68°F) |
±1% of reading ± (0.05 µS/cm or 1 digit, whichever greater) |
±1% of reading ± (0.03 ppm or 1 digit, whichever greater) |
±1% of reading | ±0.4°C |
| Typical EMC Deviation | ±1% of reading | ±1% of reading | ±1% of reading | ±0.1 °C |
| Calibration | 1 point with 6 memorized buffers: 84, 1413 ,5000,12880, 80000 or 111800 µS/cm |
1 point with HI 7037 buffer (optional) |
2 points at 0 and 50°C (plus ±1°C adjustment) |
|
| Temp. Compensation | Automatic or Manual from 0 to 60°C (can be disabled to measure actual conductivity) | |||
| Temp. Coefficient | 0.00 to 6.00 %/°C (for EC and TDS only) Default value is 1.90%/°C | |||
| TDS Factor | 0.40 to 0.80 (default value is 0.50) | |||
| Probe | HI 76309 4-ring probe, K=1 nominal and built-in temperature sensor (included) | |||
| Power Supply | 4x1.5V AA alkaline type batteries (included), or 12 VDC adapter | |||
| Auto Off | After 5 minutes (can be disabled) | |||
| Casing | IP 67 | |||
| Environment | 32 to 122°F (0 to 50°C); RH 100% | |||
| Dimensions | 7.7 x 3.1 x 2.4" (196 x 80 x 60 mm) | |||
| Weight | 18 oz (500 g) | |||
| (*) Actual conductivity (or TDS) is the non-temperature compensated conductivity (or TDS) value of a solution. | ||||
| |
|
![]() |
HI 9932 Autoranging Bench EC/TDS/NaCl/°C Meter
|
| |
|
HI 9932 is the most technologically advanced bench-top conductivity meter on the market. In addition to the wide range of Conductivity, this meter will measure Total Dissolved Solids, NaCl and temperature. The autoranging feature of the EC and TDS ranges automatically sets the meter to the scale with the highest possible resolution. Measurements can be automatically (ATC) or manually (MTC) compensated for temperature and the temperature coefficient value is user selectable. It is also possible to disable the temperature compensation and measure the actual conductivity. The meter is equipped with a stability indicator. HI 9932 also features GLP capability and allows transfer of data to a computer through an RS232 port. In addition, the meter allows the user to enter an ID code to uniquely identify the instrument.
Conductivity Range: 6 different ranges: 00.0 to 29.99 µS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm. Up to 500.0 mS/cm actual (*) Conductivity. The temperature coefficient is user selectable from 0.00 to 6.00 %.
Total Dissolved Solids: TDS factor can be adjusted from 0.40 to 0.80 (default value is 0.50). TDS ranges are: 0.00 to 14.99 ppm,15.0 to 149.9 ppm,150 to 1499 ppm,1.50 to 14.99 g/L,15.0 to 100.0 g/L and up to 400.0 g/L actual (*) TDS (with 0.80 factor).
HI 9932 is supplied complete with an HI 76310 Conductivity/TDS probe with 1m (3.3') cable, 12V DC power adapter and a dust cover.
| Specifications: | HI 9932 | |||
| EC (Autoranging) |
TDS (Autoranging) |
NaCl | Temperature | |
| Range | 00.0 to 29.99 µS/cm 30.0 to 299.9 µS/cm 300 to 2999 µS/cm 3.00 to 29.99 mS/cm 30.0 to 200.0 mS/cm Up to 500.0 mS/cm actual (*) Conductivity |
0.00 to 14.99 ppm 15.0 to 149.9 ppm 150 to 1499 ppm 1.50 to 14.99 g/L 15.0 to 100.0 g/L Up to 400.0 g/L actual (*) TDS (with 0.80 factor) |
0.0 to 400.0 % | 0.0 to 60.0°C |
| Resolution | 0.01 µS/cm (from
0.00 to 29.99 µS/cm) 0.1 µS/cm (from 30.0 to 299.9 µS/cm) 1 µS/cm (from 300 to 2999 µS/cm) 0.01 mS/cm (from 3.00 to 29.99 mS/cm) 0.1 mS/cm (over 30.0 mS/cm) |
0.01 ppm (from 0.00 to
14.99 ppm) 0.1 ppm (from 15.0 to 149.9 ppm) 1 ppm (from 150 to 1499 ppm) 0.01 g/L (from 1.50 to 14.99 g/L) 0.1 g/L (over 15.0 g/L) |
0.1 % | 0.1°C |
| Accuracy (@ 20°C/68°F) |
±1% of reading ± (0.05 µS/cm or 1 digit, whichever greater) |
±1% of reading ± (0.03 ppm or 1 digit, whichever greater) |
±1% of reading | ±0.4°C |
| Typical EMC Deviation | ±1% of reading | ±1% of reading | ±1% of reading | ±0.1 °C |
| Calibration | 1 point with 6 memorized buffers: 84, 1413 ,5000,12880, 80000 or 111800 µS/cm |
1 point with HI 7037 buffer (optional) |
2 points at 0 and 50°C (plus ±1°C adjustment) |
|
| Temp. Compensation | Automatic or Manual from 0 to 60°C (can be disabled to measure actual conductivity) | |||
| Temp. Coefficient | 0.00 to 6.00 %/°C (for EC and TDS only) Default value is 1.90%/°C | |||
| TDS Factor | 0.40 to 0.80 (default value is 0.50) | |||
| Probe | HI 76310 Platinum 4-ring probe, K=1 nominal and built-in temperature sensor (included) | |||
| GLP | Storing of last calibration data | |||
| Serial Interface | RS232 - downloading of last calibration data | |||
| Power Supply | 12 VDC adapter (included) | |||
| Auto Off | After 5 minutes (can be disabled) | |||
| Casing | IP 67 | |||
| Environment | 32 to 122°F (0 to 50°C); 95% RH non-condensing | |||
| Dimensions | 9.1 x 6.7 x 2.7" (230 x 170 x 70 mm) | |||
| Weight | 2.2 lb. (1 Kg) | |||
| (*) Actual conductivity (or TDS) is the non-temperature compensated conductivity (or TDS) value of a solution. | ||||
Combination pH Electrode for HI 99161
![]() |
||
| Code | FC 202D | |
| Body | Kynar® | |
| Reference | Junction | Single |
| Cell | Viscolene | |
| Junction | Type | Free Diffusion Layer |
| Tip | Shape | Conic |
| Dimension | Ø 12 x 12 mm | |
| Plug | Type | DIN |
| Cable | 5 wire | |
| Temp range °C | 0/+50 | |
| Pressure PSI/BAR | 1.45/0.1 | |
![]() |
HI 99161 Waterproof and heavy-duty
|
HI 99161’s waterproof casing provides excellent protection from water and humidity typically present in the food industry. HI 99161 comes supplied with the FC 202D pH electrode with built-in temperature sensor specially designed for use in the food sector. This electrode features a rugged, easy to clean, Kynar® body that tapers to a strong conic tip ideal for measurements in semisolids such as meats and cheeses. The electrode has a free diffusion sleeve type reference junction which prevents the typical problems of clogging in viscous liquids or samples with high solids content such as milk or condiments. The reference electrolyte used in the FC 202D is free from the poisonous silver chloride which prevents food contamination by the electrode. HI 99161 allows push button calibration at either NIST or standard buffer sets with auto recognition and a stability indicator. The temperature is always displayed on the secondary level of the large LCD.
| Specifications: | HI 99161 |
| Range | 0.00 to 14.00 pH; 0.0 to 60.0°C |
| Resolution | 0.01 pH/0.1°C |
| Accuracy | ±0.01 pH/±0.5°C |
| Typical EMC Deviation | ±0.3 pH/±1°C |
| Calibration | Automatic, 2 points with two sets of standard buffers |
| Temperature Compensation | Automatic, 0 to 60°C(32 to 140°F) |
| Electrode | FC 202D combination, DIN conn., 1 m cable (included) |
| Battery Type/Life | 4 x 1.5V AA; approx. 1000 hrs. continuous use |
| Environment | 0 to 50°C; RH 100% |
| Dimensions | 150 x 80 x 28 mm (5.9 x 3.1 x 1.1”) |
| Weight | 210 g (7.5 oz.) |
|