HI 93530 Microprocessor, K-Type Thermocouple Waterproof Thermometer
with 0.1 Resolution up to 999.9º C / F
- HOLD Function The HOLD function freezes the reading on the
display
- High Accuracy ±0.5°C (-100.0 to 999.9°C) or ±1.0°F
(-148.0 to 999.9°F), accuracy once only achievable with research-grade
equipment.
- Two Different Ranges HI 93530 measures in Centigrade as well
as Fahrenheit.
- Order Information
- Specifications
|
|
HI 93530 and HI 93530N are waterproof thermometers that use a powerful microprocessor
to linearize the response of the thermocouple to achieve high accuracy and
resolution. These instruments can read with a resolution of 0.1 in the -149.9
to 999.9°C and -24.9 to 999.9°F ranges. The meters are equipped with
a HOLD function that freezes the current reading on the LCD. A °C/°F
button will change between the Celsius and Fahrenheit ranges. An important
feature where measurements are necessary in degrees Celsius as well as Fahrenheit.
HI 93530N has a CAL button to allow the operator to calibrate the meter and
probe in an ice bath at 0°C. This will assure the removal of the combined
meter and probe interchange error. In addition to the calibration feature,
HI 93530N features a user-activated backlight for low or no light conditions.
Remaining battery power is displayed at startup and a low battery warning signal
and error prevention provides advanced power management to both instruments.
A wide range of thermocouple probes are available for applications such as
liquid, air and semisolids.
HI 93530 is supplied complete with wrist-strap, 3 x 1.5V AA batteries and
instruction manual. HI 93530N is supplied complete with wrist-strap, 3 x 1.5V
AA batteries and instruction manual.
| Specifications |
HI 93530/HI
93530N |
| Range |
-200.0 to 999.9°C
|
-328.0
to 999.9°F |
| |
1000 to 1371°C |
1000 to 2500°F |
Resolution
|
0.1°C (-149.9 to 999.9°C) |
0.1°F (-24.9 to
999.9°F) / 0.2°F (-249.9 to -25.0°F) |
| |
0.2°C (-200.0 to -150.0°C)
/ 1°C (outside) |
0.3°F (-328.0 to
-250.0°F) 1°F (outside) |
| Accuracy |
±0.5°C (-100.0
to 999.9°C) / ±1°C (outside) excluding probe error |
| |
±1°F (-148.0
to 999.9°F) / ±1.5°F (outside) for one year, excluding
probe error |
Typical EMC Deviation
|
±3°C |
±6°F |
| |
with HI 766 K-type
thermocouple probe |
Probe
|
K-type thermocouple
(optional) |
Battery Type
/ Life
|
3 x 1.5V AA / approx.
500 hours of continuous use. |
| |
Auto-off: selectable
60 minutes or OFF |
Environment
|
-10 to 60°C (14
to 140°F); RH 100% |
| Dimensions |
150 x 80 x 36 mm (5.9
x 3.1 x 1.4”) |
| Weight |
250 g (8.8 oz.) |
|