HI 221 HI 223 pH/ORP/Temperature Bench Meters.
Setting New Calibration Standards

  • "Log On Demand"Function can record up to 500 settings with the HI 223 and 100 with the HI 221
  • Exclusive Cal-Check™ system prevents common calibration errors
  • Windows Compatible - With the HI 92000 software and an RS232 port, download the data to your PC to produce tables and graphic formats.
  • Order Information
  • Specifications


HI 221 and HI 223 are pH/ORP/Temperature bench meters setting new calibration standards. A deep understanding of the pH calibration process can only come from a manufacturer of instruments as well as electrodes and calibration solutions. Hanna Instruments is one of the few manufacturers in the world to produce meters, electrodes and buffer solutions. Proper calibration of the pH meter and pH electrode system is critical in order to achieve reliable results and Hanna has developed a new system that monitors the two most important parameters during the calibration process, the pH electrode and the buffer solution: Cal-Check™. This new system warns the users in the event the pH electrode is dirty and if the calibration buffer is out of specification (cross contamination). When a pH electrode is not properly cleaned, even the smallest residues of samples left on the sensitive glass can produce slope errors up to a tenth of a pH unit.
A pH buffer solution that has been contaminated can also drift by a few tenths of a pH unit, resulting in erroneous calibration. Dirty pH electrodes and buffer solutions cannot be detected by conventional pH meters, resulting in wrong calibrations and subsequent erroneous pH measurements. Hanna's new pH meters have addressed this problem by displaying on the LCD status symbols that warn the user to clean or replace the pH electrode or to replace the buffer solution with a fresh one. This new calibration concept removes the guesswork, and guarantees the user that the equipment is in the best condition. Both instruments have a "log on demand" function to record 100 (HI 221) or 500 (HI 223) readings, RS232 port for computer connection, automatic or manual temperature compensation (ATC or MTC), and an extended range of 7 memorized calibration buffers. HI 221 offers pH readout of 0.01 pH, and HI 223 has a resolution of 0.001 pH.


   
GLP:
The instruments store calibration data. In addition, they can be programmed to give an alert when the instrument requires a new calibration
Recall:
Measurements taken with the HI 221 and HI 223 can be stored and recalled at a a later time.
  Log On Demand:
Both instruments have a "log on demand" function to record 100 (HI 221) or 500 (HI 223) readings.

 

Specifications
HI 221
HI 223
pH Range
-2.00 to 16.00
-2.00 to 16.00 or -2.000 to 16.000
pH Accuracy
±0.01
±0.01; ±0.002
pH Resolution
0.01
0.01; 0.001
mV Range
-699.9 to 699.9; -2000 to 2000
-999.9 to 999.9; -2000 to 2000
mV Accuracy
±0.2; ±1
±0.2 (±699.9); ±0.5 (±999.9); ±1 (±2000)
mV Resolution
0.1, 1
0.1; 1
°C Range
-20.0 to 120.0
-20.0 to 120.0
°C Accuracy
±0.4
±0.4
°C Resolution
0.1
0.1
Temperature Comp.
Manual (MTC) or Automatic (ATC) temperature compensation
pH electrode
HI 1131P glass body, single junction refillable cell, BNC + pin (included)
Temperature probe
HI 7669/2W stainless steel probe (included)
PC Interface
Opto-isolated RS232
Logging
100 points
500 points
Input impedance
1012 ohm
Power
12VDC adapter (included)
Environment
0 to 50°C (32 to 122°F) 100% RH
Dimensions
196 x 80 x 60 mm (7.7 x 3.1 x 2.4”)
Weight
425 g (15 oz.)

HI 991001 & HI 991002
Extended Range Waterproof pH/ORP and Temperature Meters

  • Stability Indicator and Hold Feature insure proper readings
  • Battery Life of over 1500 Hours
  • Automatic Calibration using N.I.S.T
  • Order Information
  • Specifications

The new HI 991001 and HI 991002 meters from Hanna offer IP 67 waterproof protection in a compact casing. The included multi-parameter electrode has a built-in temperature sensor. No additional temperature probe is required. The electrode also contains a mini amplifier to render your measurements impervious to noise and electrical interference. The large display shows readings in an extended range from -2.00 to 16.00 pH and simultaneously shows temperature from -5.0 to 105.0 °C or 23 to 221°F. HI 991002 also measures ORP from -1999 to 1999 mV. The mV scale of this meter can be used with the available HI 1296D pH/temperature electrode to check the condition of the pH electrode. These meters have a stability indicator and hold feature that prompts you when to take the reading & freezes the display for easy and accurate recording. The large display also has graphic symbols to guide you through all operations. The battery life of the meters guarantee over 1500 hours of continuous use. At startup, they perform a self-check and then display the remaining battery level to assure proper working condition. Calibration is performed automatically at one or two points using standard or N.I.S.T. buffers.

HI 991001 is supplied complete with HI 1296D pH/temperature electrode, 3 x 1.5V AA batteries and carrying case.
HI 991002 is supplied complete with HI 1297D pH/ORP/temperature electrode, 3 x 1.5V AA batteries and carrying case.

Specifications HI 991001 HI 991002
Ranges: pH -2.00 to 16.00
-2.00 to 16.00
  ORP - ±1999 mV
  Temperature -5.0 to 105.0°C or 23.0 to 221.0°F
-5.0 to 105.0°C or 23.0 to 221.0°F
Resolution: pH 0.01
0.01
  ORP - 1 mV
  Temperature 0.1°C or 0.1°F
0.1°C or 0.1°F
Accuracy pH ±0.02
±0.02
(@20°C/68°F): ORP -
±2 mV
  Temperature ±0.5 up to 60°C, ±1°C up to 105°C
±0.5 up to 60°C, ±1°C up to 105°C
    ±1°F up to 140°F, ±2°F up to 221°F
±1°F up to 140°F, ±2°F up to 221°F
Typical EMC pH ±0.02
±0.02
Deviation: ORP - ±2 mV
  Temperature ±0.2°C or ±0.4°F ±0.2°C or ±0.4°F
 pH Calibration  Automatic 1 or 2 points with 2 set of standardized buffers
  (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)
Temp. Compensation: Automatic from -5 to 105°C (23 to 221°F) (for pH only)
Electrode: HI 1296D combination amplified pH/temperature HI 1297D combination amplified pH/ORP/temperature
  with DIN connector and 1 m (3.3’) cable (included) with DIN connector and 1 m (3.3’) cable (included)
Environment: 0 to 50°C (32 to 122°F); RH 100%
Battery Type: 3 x 1.5V AA
Battery Life: approximately 1500 hours of continuous use. Auto-off after 8 minutes
Dimensions: 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight: 245 g (8.6 oz.)


HI 991003 - Portable pH Meter with Sensor Check

  • Stability Indicator and Hold Feature insure proper readings
  • Battery Life of over 1500 Hours
  • Automatic Calibration using N.I.S.T
  • Order Information
  • Specifications

With today’s high level of demand for quality and accuracy, it is critical, when measuring pH, to know the status of the electrode, since it is the most important element of the pH measurement system. An old, out of specifications pH electrode can result in erroneous pH measurements that can seriously damage the process. Hanna Instruments has solved this problem with the unique sensor check feature that allows the user to establish the status of the pH electrode before performing measurements. The sensor check feature consists of a mV pH scale that shows the characteristics (slope and offset) of the sensor, allowing the user to determine if the electrode is in good condition. In several countries, local agencies require pH electrodes to have slope % as high as 95%. This can only be done with the sensor check feature.
HI 991003 is protected in a waterproof casing for use in humid and wet environments. It also features a dual level LCD that displays pH or ORP and temperature (in degree C or F). Automatic pH calibration can be performed with 5 memorized buffers (for NIST or standard calibration).
HI 991003 provides over 1500 hours of battery life and an 8 minute auto-off period to save battery power.

HI 991003 is supplied complete with HI 1297D pH/ORP/temperature electrode, 3 x 1.5V AA batteries, carrying case and instructions.

Specifications HI 991404
Ranges: pH -2.00 to 16.00
  pH (in mV) ±825 mV
  ORP ±1999 mV
  Temperature -5.0 to 105.0°C or 23.0 to 221.0°F
Resolution: pH 0.01
  pH (in mV) 1 mV
  ORP 1 mV
  Temperature 0.1°C or 0.1°F
Accuracy pH ±0.02
(@20°C/68°F): pH (in mV) ±1 mV
  ORP ±2 mV
  Temperature ±0.5°C up to 60°C, ±1°C up to 105°C
    ±1.0°F up to 140°F, ±2°F up to 221°F
Typical EMC pH ±0.02
Deviation: pH (in mV) ±2 mV
  ORP ±2 mV
  Temperature ±0.2°C or ±0.4°F
 pH Calibration  Automatic 1 or 2 points with 2 set of standardized buffers
  (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)
Temp. Compensation: Automatic from -5 to 105°C (23 to 221°F) (for pH only)
Electrode: HI 1297D combination amplified pH/ORP/temperature electrode
  with DIN connector and 1 m (3.3’) cable (included)
Environment: 0 to 50°C (32 to 122°F); RH 100%
Battery Type: 3 x 1.5V AA
Battery Life: approximately 1500 hours of continuous use. Auto-off after 8 minutes
Dimensions: 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight: 245 g (8.6 oz.)


{short description of image}

HI 99131 Plating Baths pH Meter

  • Application Specific Electrode - The stainless steel HI 62911 is designed for continuous use in the harshest of industrial environments.
  • Stability Indicator- To simplify your measurement process, the LCD shows when the pH electrode has stabilized.
  • Easy To Use- Graphic symbols and automatic buffer recognition simplify your pH monitoring.
  • Automatic Temperature Compensation - With ATC, pH readouts are always accurate and precise.
  • Order Information
  • Specifications

The new HI 99131 from Hanna is a waterproof, portable pH/temperature meter ideal for use in plating baths. HI 62911 double junction pH electrode (included) has a stainless steel body and utilizes proven recessed flat tip technology. The body of the probe also functions as a potential matching pin to assure stable readings and an extended sensor life. The probe tip incorporates an annular Teflon® junction for maximum surface contact giving increased response and stability, as well as an integral temperature sensor eliminating the need for an additional temperature probe. The recessed flat tip is easy to clean and prevents solids in solution from collecting on the sensor. This advanced electrode also contains a mini amplifier to boost the electrode signal rendering the meter impervious to noise and interference.

The meter reads from -2.00 to 16.00 pH while simultaneously showing the temperature in °C or °F. Graphic icons guide operations and a stability indicator with hold feature determines when to freeze the reading for easy record keeping. Calibration is performed automatically at one or two points with standard or NIST calibration buffers. Battery life is over 1500 hours and at startup, the LCD shows the remaining battery power. In addition, BEPS (Battery Error Prevention System) prevents bad readings due to low voltage and an 8 minute auto-off period saves battery power.

HI 99131 is supplied complete with HI 62911 double junction pH electrode, 3 x 1.5V AA batteries, instruction manual and carrying case.

Specifications: HI 99131
Range pH -2.00 to 16.00
  Temperature -5.0 to 105.0°C or 23.0 to 221.0°F
Resolution pH 0.01
  Temperature 0.1 °C and °F
Accuracy pH ±0.02 pH
(@20°C/68°F) Temperature ±0.5°C up to 60°C; ±1°C outside
    ±1°F up to 140°F; ±2°F outside
Typical EMC pH ±0.3 pH; ±1°C
Deviation Temperature ±0.2°C or ±0.4°F
pH Calibration Automatic 1 or 2 points with 2 sets of 3 memorized buffers
(4.01/7.01/10.01 or 4.01/6.86/9.18)
Temp. Compensation Automatic
Electrode HI 62911 amplified pH electrode w/built-in temperature sensor & matching pin (included)
Battery Type 3 x 1.5V AA
Battery Life approximately 1500 hours. Auto-off after 8 minutes
Environment 0 to 50°C (32 to 122°F); 100% RH
Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight 207 g (7.3 oz.)


{short description of image}

HI 99141 - Plating Baths pH Meter

  • Rugged Electrode - The HI 72911 is nearly unbreakable thanks to its stainless steel body.
  • Automatic Calibration- Choose between five memorized buffers to automatically calibrate the instrument.
  • Messages on the Display- The operator is guided through operation on the LCD.
  • Automatic Temperature Compensation - With ATC, pH readouts are always accurate and precise.
  • Order Information
  • Specifications

Hanna’s new HI 99141 is a waterproof, portable pH/temperature meter specifically designed for boiler & cooling tower applications. HI 72911 double junction pH electrode (included) has an unbreakable stainless steel body and a flat tip. The electrode also features an annular Teflon® junction for maximum surface contact giving increased response and stability. The stainless steel body of the probe functions as a shield and adds to the sensor’s life. The flat tip is easy to clean and prevents solids in solution from collecting on the sensor. This advanced electrode also contains an integral temperature sensor and a mini amplifier to boost the electrode signal eliminating the effects of noise and interference.

The meter reads from -2.00 to 16.00 pH while simultaneously showing the temperature in °C or °F. Graphic icons guide operations and a stability indicator with hold feature determines when to freeze the reading for easy record keeping. Calibration is performed automatically at one or two points with standard or NIST calibration buffers. Battery life is over 1500 hours and at startup, the LCD shows the remaining battery power. In addition, BEPS (Battery Error Prevention System) prevents bad readings due to low voltage and an auto-off period of 8 minutes saves battery power.

HI 99141 is supplied complete with HI 72911 double junction pH electrode, 3 x 1.5V AA batteries, instruction manual and carrying case.

Specifications: HI 99141
Range pH -2.00 to 16.00
  Temperature -5.0 to 105.0°C or 23.0 to 221.0°F
Resolution pH 0.01
  Temperature 0.1 °C and °F
Accuracy pH ±0.02 pH
(@20°C/68°F) Temperature ±0.5°C up to 60°C; ±1°C outside
    ±1°F up to 140°F; ±2°F outside
Typical EMC pH ±0.3 pH; ±1°C
Deviation Temperature ±0.2°C or ±0.4°F
pH Calibration Automatic 1 or 2 points with 2 sets of 3 memorized buffers
(4.01/7.01/10.01 or 4.01/6.86/9.18)
Temp. Compensation Automatic
Electrode HI 72911 amplified pH electrode w/built-in temperature sensor & matching pin (included)
Battery Type 3 x 1.5V AA
Battery Life approximately 1500 hours. Auto-off after 8 minutes
Environment 0 to 50°C (32 to 122°F); 100% RH
Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight 207 g (7.3 oz.)

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117