C 221 Honey Color Analyzer & Refractometer


Honey color varies naturally in a wide range of tonalities, ranging from light yellow to amber, dark amber and black in extreme cases. Sometimes green or red hues may occur. Color of untreated honey depends on botanical origin: for this reason, color is very important for definition and commercial classification of monofloral honeys. Honey darkens with age, and other changes in color may result from beekeeper's interventions and from different ways of conservation (E.G.: use of old honeycombs, contact with metals, high temperatures, exposure to light, etc).

The primary characteristic for commercial honey classification is color. Color classes are expressed in millimeters (mm) Pfund grades, compared to an analytical grade Glycerol Standard Reference.

The C 221 portable microprocessor analyzer measures the percent of light transmittance of honey compared to analyitcal, reagent grade glycerol. The transmittance value allows for identification of the honey Pfund grade. The intrument directly displays the measurement result expressed in mm Pfund.

Measurements are made using matched square optical cuvets having a 10mm light path.

Display Codes aid the user in routine operations.

The C 221 features an auto-off feature that will turn the instrument of after 10 minutes of non-use.

The companion Honey Refractometer for measuring water content is rugged and simple to use with easily identifiable readings .


C 221
is supplied complete with the Honey Refractometer, (5) sample cuvets, (1) light shield cap, (1) 30ml bottle of glycerol, (2) 9V batteries, 12VDC transformer and instruction manual, and quick reference cards for the C 221 and Honey Refractometer


Specifications: C 221
Range 0 to 150mm Pfund
Resolution 1 mm Pfund
Accuracy ±2mm Pfund

USDA Color Standards
Designations
Color Range Pfund
Scales (mm)
Water White
< = 8
Extra White
> 8 - < = 17
White
> 17 - < = 34
Extra Light Amber
> 34 - < = 50
Light Amber
> 50 - < = 85
Amber
> 85 - < = 114
Dark Amber
> 114


HI 95759 HI 95760 Maple Syrup Colorimeters

  • Lightweight A rugged housing weighing under 300 grams (10 oz.), low battery warning, auto-shut-off and simple operation make the these meters indispensable in the field.
  • Versatile Available in English with USDA syrup grades and also in French with Canada Federal & Quebec grades.
  • Affordable and easy to use Battery operated, handheld with a rugged carrying case. Syrup grading has never been easier
  • Reagents Sets:
    C 219 Kit
  • Order Information
  • Specifications

What maple producers have been waiting for! Simply get your digital reading with push button ease and compare the digital readout to the grading chart printed on the face of your meter. Measurements are performed by using matched square optical cuvets having a 10mm light path. These maple syrup transmittance analyzers measure the percent light transmittance of maple syrup as compared to analytical reagent glycerol. The transmittance value displayed allows easy and indisputable identification of syrup quality class.

The HI 95759 and HI 95760 handheld, portable maple syrup transmittance analyzers are high precision, USDA (HI 95759) or Canada Federal and Quebec (HI 95760) compliant photometers that bring judging "by eye" to an end. Three button operation, battery powered with a rugged carrying case makes these meters ideal for extended field use.

These meters are supplied complete with six sample cuvets, one light shield cap, two 5 mL syringes, 30 mL of glycerol, one 9 volt battery, instruction manual and a heavy-duty carrying case.

Specifications: HI 95759 & HI 95760
Range 0.0 to 100.0% Transmittance
Resolution 0.1% Transmittance
Accuracy ±1% @ 75% Transmittance
Typical EMC Deviation ±0.1% Transmittance
Light Source Tungsten lamp with narrow band interference filter @ 560nm
Light Life Life of the Instrument
Light Detector Silicon Photocell
Battery Type 1 x 9V /
Auto-shut off after 10 minutes of non-use
Environment 32 to 122°F (0 to 50°C); RH 95% max non-condensing
Dimensions 7.1 x 3.3 x 1.8" (180 x 83 x 46mm)
Weight 10 oz. (290 grams)


HI 95711 Total and Free Chlorine photometer kit.

  • Lightweight A rugged housing weighing under 300 grams (10 oz.), low battery warning, auto-shut-off and simple operation make the these meters indispensable in the field.
  • Versatile Able to read both free and total chlorine
  • Affordable and easy to use Battery operated, handheld with a rugged carrying case.
  • Reagent Sets:
    • HI 93701-01/03
    • HI 93711-01/03
  • Order Information
  • Specifications

The HI 95711 measure free and total chlorine from 0.00 to 5.00 ppm. The new photometer design incorporates a tungsten lamp and narrow band fliter encapsulated in a transparant cell to protect against dust, dirt and water to ensure a high level of accuracy and repeatability. A Cal Check feature allows the user to verify the accuracy of the meter using a calibration/validation standard that is provided with easch meter. The HI 95711 complies with EPA testing standard 330.5 for wastewater and standard method 4500-Cl G for drinking water.

The HI 95711 Kit Includes:

  • Two Sample Cuvets and Caps
  • 9V Battery
  • Scissors
  • Instruction Manual
  • Rigid carrying case

Specifications: HI 95711 Free/Total
Range 0.00 to 5.00 mg/L / 0.00 to 5.00 mg/L
Resolution 0.01 mg/L from 0.00 to 3.50 / 0.10 mg/L above 3.50 mg/L
Accuracy ±0.02 mg/L @ 1.00 mg/L
Typical EMC Deviation ±0.01% mg/L
Light Source Tungsten lamp with narrow band interference filter @ 525nm
Light Life Life of the Instrument
Light Detector Silicon Photocell
Battery Type 1 x 9V /
Auto-shut off after 10 minutes of non-use
Environment 32 to 122°F (0 to 50°C); RH 95% max non-condensing
Dimensions 7.1 x 3.3 x 1.8" (180 x 83 x 46mm)
Weight 10 oz. (290 grams)


HI 95721 Iron High Range Kit

  • Lightweight A rugged housing weighing under 300 grams (10 oz.), low battery warning, auto-shut-off and simple operation make the these meters indispensable in the field.
  • Affordable and easy to use Battery operated, handheld with a rugged carrying case.
  • Reagent Sets:
    • HI 93721-01/03
  • Order Information
  • Specifications

The HI 95721 is an auto diagnostic portable microprocessor meter that benefits from hanna's years of experience as a manufacturer of analyitical instruments. It has the advanced optical system based on a special tungsten lam and a narrow band interference filter that allows most accurate and repeatable readings. All instruments are factory calibrated and the electronic and optical design minimizes the need of frequent calibration.

With the powerful CAL CHECK validation function you are able to validate good performance of your instrument at any time. The validation procedure is extremely user friendly. Just use the exclusive Hanna ready-made, Nist Traceable standards to verify the performance of the instrument and recalibrate if necessary.

The HI 95721 kit includes:

  • Two Sample Cuvets and Caps
  • 9V Battert
  • Scissors
  • Instruction Manual
  • Rigid carrying case
Specifications: HI 95721
Range 0.00 to 5.00 mg/L
Resolution 0.01 mg/L
Accuracy ±0.010 mg/L @ 1.50 mg/L
Typical EMC Deviation ±0.01 mg/L
Light Source Tungsten lamp with narrow band interference filter @ 525nm
Light Life Life of the Instrument
Light Detector Silicon Photocell
Method Adaptation of the USEPA method 315B and the Standard Method 3500-Fe B. The reaction between iron and the phenantroline reagent causes and orange tint in the sample.
Battery Type 1 x 9V /
Auto-shut off after 10 minutes of non-use
Environment 32 to 122°F (0 to 50°C); RH 95% max non-condensing
Dimensions 7.1 x 3.3 x 1.8" (180 x 83 x 46mm)
Weight 10 oz. (290 grams)


HI 93753 Chloride Meter

  • One touch Operation equals clear results fast
  • Long Battery Life - a 9V battery provides for 300+ ours of continuous operation, 10 minute auto shut-off assures long battery life
  • Easy Field Measurements The measurement procedure has been developed to get accurate readings both in laboratories and in the field. Easy-to-use chemicals and two button measurement .
  • Reagents Sets
    HI 93753-01
    HI 93753-03
  • Order Information
  • Specifications

Chloride ions are one of the major inorganic anions in water and wastewater. Although high concentrations of chloride in water are not known to be toxic to humans, its regulation is mainly due to adverse effects on taste.

It is essential to monitor chloride concentrations in boiler systems to prevent metal parts being damaged. In high levels, chloride can corrode stainless steel. The level of chloride concentrations in boiler and cooling towers varies from small quantities to very high levels. Furthermore high levels of chloride can be toxic to plant life.

Drinking water: Chloride is a common non-toxic material present in small amounts in drinking water and produces a detectable salty taste at the aesthetic objective level of 250 mg/L (limit referred to the EPA Maximum Contaminant Level [MCL]). Measured levels are normally under 20 mg/L (ppm).

Specifications
HI 93753 (Chloride)
Range
0.0 to 20.0 mg/L
Resolution
0.1 mg/L
Accuracy (@20°C/68°F)
±0.5 mg/L ±6% of reading
Typical EMC Deviation
±0.1 mg/L
Light Source
Light Emitting Diode @ 470 nm
Light Life
Life of the instrument
Light Detector
Silicon Photocell
Battery Type / Life
1 x 9V / approximately 40 hours of continuous use. Auto-off after 10 minutes of non-use
Environment
0 to 50°C (32 to 122°F); RH 95%
Dimensions
180 x 83 x 46 mm (7.1 x 3.3 x 1.8”)
Weight
290 g (10 oz.)
Method
Adaptation of the mercury (II) thiocyanate method. the intensity of color is proportional to the chloride ion concentration.

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117