Combination pH Electrode for HI 99161

Code FC 202D
Body Kynar®
Reference Junction Single
Cell Viscolene
Junction Type Free Diffusion Layer
Tip Shape Conic
Dimension Ø 12 x 12 mm
Plug Type DIN
Cable   5 wire
Temp range °C 0/+50
Pressure PSI/BAR 1.45/0.1

Combination pH Electrode for HI 991001, HI 991002 & HI 991003

Code HI 1296D
Body Ultem®
Reference Junction Single
Cell Gel
Junction Type 1 Ceramic Ø 1.2 mm
Tip Shape Sphere
Dimension Ø 5.0 mm
Plug Type DIN
Cable   7 wire
Temp range °C 0/+80
Pressure PSI/BAR 7.25/0.5

HI 991001 & HI 991002
Extended Range Waterproof pH/ORP and Temperature Meters

  • Stability Indicator and Hold Feature insure proper readings
  • Battery Life of over 1500 Hours
  • Automatic Calibration using N.I.S.T
  • Order Information
  • Specifications

The new HI 991001 and HI 991002 meters from Hanna offer IP 67 waterproof protection in a compact casing. The included multi-parameter electrode has a built-in temperature sensor. No additional temperature probe is required. The electrode also contains a mini amplifier to render your measurements impervious to noise and electrical interference. The large display shows readings in an extended range from -2.00 to 16.00 pH and simultaneously shows temperature from -5.0 to 105.0 °C or 23 to 221°F. HI 991002 also measures ORP from -1999 to 1999 mV. The mV scale of this meter can be used with the available HI 1296D pH/temperature electrode to check the condition of the pH electrode. These meters have a stability indicator and hold feature that prompts you when to take the reading & freezes the display for easy and accurate recording. The large display also has graphic symbols to guide you through all operations. The battery life of the meters guarantee over 1500 hours of continuous use. At startup, they perform a self-check and then display the remaining battery level to assure proper working condition. Calibration is performed automatically at one or two points using standard or N.I.S.T. buffers.

HI 991001 is supplied complete with HI 1296D pH/temperature electrode, 3 x 1.5V AA batteries and carrying case.
HI 991002 is supplied complete with HI 1297D pH/ORP/temperature electrode, 3 x 1.5V AA batteries and carrying case.

Specifications HI 991001 HI 991002
Ranges: pH -2.00 to 16.00
-2.00 to 16.00
  ORP - ±1999 mV
  Temperature -5.0 to 105.0°C or 23.0 to 221.0°F
-5.0 to 105.0°C or 23.0 to 221.0°F
Resolution: pH 0.01
0.01
  ORP - 1 mV
  Temperature 0.1°C or 0.1°F
0.1°C or 0.1°F
Accuracy pH ±0.02
±0.02
(@20°C/68°F): ORP -
±2 mV
  Temperature ±0.5 up to 60°C, ±1°C up to 105°C
±0.5 up to 60°C, ±1°C up to 105°C
    ±1°F up to 140°F, ±2°F up to 221°F
±1°F up to 140°F, ±2°F up to 221°F
Typical EMC pH ±0.02
±0.02
Deviation: ORP - ±2 mV
  Temperature ±0.2°C or ±0.4°F ±0.2°C or ±0.4°F
 pH Calibration  Automatic 1 or 2 points with 2 set of standardized buffers
  (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)
Temp. Compensation: Automatic from -5 to 105°C (23 to 221°F) (for pH only)
Electrode: HI 1296D combination amplified pH/temperature HI 1297D combination amplified pH/ORP/temperature
  with DIN connector and 1 m (3.3’) cable (included) with DIN connector and 1 m (3.3’) cable (included)
Environment: 0 to 50°C (32 to 122°F); RH 100%
Battery Type: 3 x 1.5V AA
Battery Life: approximately 1500 hours of continuous use. Auto-off after 8 minutes
Dimensions: 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight: 245 g (8.6 oz.)


HI 991003 - Portable pH Meter with Sensor Check

  • Stability Indicator and Hold Feature insure proper readings
  • Battery Life of over 1500 Hours
  • Automatic Calibration using N.I.S.T
  • Order Information
  • Specifications

With today’s high level of demand for quality and accuracy, it is critical, when measuring pH, to know the status of the electrode, since it is the most important element of the pH measurement system. An old, out of specifications pH electrode can result in erroneous pH measurements that can seriously damage the process. Hanna Instruments has solved this problem with the unique sensor check feature that allows the user to establish the status of the pH electrode before performing measurements. The sensor check feature consists of a mV pH scale that shows the characteristics (slope and offset) of the sensor, allowing the user to determine if the electrode is in good condition. In several countries, local agencies require pH electrodes to have slope % as high as 95%. This can only be done with the sensor check feature.
HI 991003 is protected in a waterproof casing for use in humid and wet environments. It also features a dual level LCD that displays pH or ORP and temperature (in degree C or F). Automatic pH calibration can be performed with 5 memorized buffers (for NIST or standard calibration).
HI 991003 provides over 1500 hours of battery life and an 8 minute auto-off period to save battery power.

HI 991003 is supplied complete with HI 1297D pH/ORP/temperature electrode, 3 x 1.5V AA batteries, carrying case and instructions.

Specifications HI 991404
Ranges: pH -2.00 to 16.00
  pH (in mV) ±825 mV
  ORP ±1999 mV
  Temperature -5.0 to 105.0°C or 23.0 to 221.0°F
Resolution: pH 0.01
  pH (in mV) 1 mV
  ORP 1 mV
  Temperature 0.1°C or 0.1°F
Accuracy pH ±0.02
(@20°C/68°F): pH (in mV) ±1 mV
  ORP ±2 mV
  Temperature ±0.5°C up to 60°C, ±1°C up to 105°C
    ±1.0°F up to 140°F, ±2°F up to 221°F
Typical EMC pH ±0.02
Deviation: pH (in mV) ±2 mV
  ORP ±2 mV
  Temperature ±0.2°C or ±0.4°F
 pH Calibration  Automatic 1 or 2 points with 2 set of standardized buffers
  (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)
Temp. Compensation: Automatic from -5 to 105°C (23 to 221°F) (for pH only)
Electrode: HI 1297D combination amplified pH/ORP/temperature electrode
  with DIN connector and 1 m (3.3’) cable (included)
Environment: 0 to 50°C (32 to 122°F); RH 100%
Battery Type: 3 x 1.5V AA
Battery Life: approximately 1500 hours of continuous use. Auto-off after 8 minutes
Dimensions: 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight: 245 g (8.6 oz.)

Combination pH Electrode for HI 991002 & HI 991003

Code HI 1297D
Body Ultem®
Reference Junction Single
Cell Gel
Junction Type 1 Ceramic Ø 1.2 mm
Tip Shape Conic Rod
Dimension Ø 3 mm
Plug Type DIN
Cable   7 wire
Temp range °C 0/+80
Pressure PSI/BAR 7.25/0.5


HI 991001 & HI 991002
Extended Range Waterproof pH/ORP and Temperature Meters

  • Stability Indicator and Hold Feature insure proper readings
  • Battery Life of over 1500 Hours
  • Automatic Calibration using N.I.S.T
  • Order Information
  • Specifications

The new HI 991001 and HI 991002 meters from Hanna offer IP 67 waterproof protection in a compact casing. The included multi-parameter electrode has a built-in temperature sensor. No additional temperature probe is required. The electrode also contains a mini amplifier to render your measurements impervious to noise and electrical interference. The large display shows readings in an extended range from -2.00 to 16.00 pH and simultaneously shows temperature from -5.0 to 105.0 °C or 23 to 221°F. HI 991002 also measures ORP from -1999 to 1999 mV. The mV scale of this meter can be used with the available HI 1296D pH/temperature electrode to check the condition of the pH electrode. These meters have a stability indicator and hold feature that prompts you when to take the reading & freezes the display for easy and accurate recording. The large display also has graphic symbols to guide you through all operations. The battery life of the meters guarantee over 1500 hours of continuous use. At startup, they perform a self-check and then display the remaining battery level to assure proper working condition. Calibration is performed automatically at one or two points using standard or N.I.S.T. buffers.

HI 991001 is supplied complete with HI 1296D pH/temperature electrode, 3 x 1.5V AA batteries and carrying case.
HI 991002 is supplied complete with HI 1297D pH/ORP/temperature electrode, 3 x 1.5V AA batteries and carrying case.

Specifications HI 991001 HI 991002
Ranges: pH -2.00 to 16.00
-2.00 to 16.00
  ORP - ±1999 mV
  Temperature -5.0 to 105.0°C or 23.0 to 221.0°F
-5.0 to 105.0°C or 23.0 to 221.0°F
Resolution: pH 0.01
0.01
  ORP - 1 mV
  Temperature 0.1°C or 0.1°F
0.1°C or 0.1°F
Accuracy pH ±0.02
±0.02
(@20°C/68°F): ORP -
±2 mV
  Temperature ±0.5 up to 60°C, ±1°C up to 105°C
±0.5 up to 60°C, ±1°C up to 105°C
    ±1°F up to 140°F, ±2°F up to 221°F
±1°F up to 140°F, ±2°F up to 221°F
Typical EMC pH ±0.02
±0.02
Deviation: ORP - ±2 mV
  Temperature ±0.2°C or ±0.4°F ±0.2°C or ±0.4°F
 pH Calibration  Automatic 1 or 2 points with 2 set of standardized buffers
  (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)
Temp. Compensation: Automatic from -5 to 105°C (23 to 221°F) (for pH only)
Electrode: HI 1296D combination amplified pH/temperature HI 1297D combination amplified pH/ORP/temperature
  with DIN connector and 1 m (3.3’) cable (included) with DIN connector and 1 m (3.3’) cable (included)
Environment: 0 to 50°C (32 to 122°F); RH 100%
Battery Type: 3 x 1.5V AA
Battery Life: approximately 1500 hours of continuous use. Auto-off after 8 minutes
Dimensions: 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight: 245 g (8.6 oz.)

 

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117