Combination pH Electrode for
HI 99161
 |
| Code |
FC 202D |
| Body |
Kynar® |
| Reference |
Junction |
Single |
| Cell |
Viscolene |
| Junction |
Type |
Free Diffusion Layer |
| Tip |
Shape |
Conic |
| Dimension |
Ø 12 x 12 mm |
| Plug |
Type |
DIN |
| Cable |
|
5 wire |
| Temp range °C |
0/+50 |
| Pressure PSI/BAR |
1.45/0.1 |
Combination pH Electrode for HI
991001, HI 991002 & HI 991003
 |
| Code |
HI 1296D |
| Body |
Ultem® |
| Reference |
Junction |
Single |
| Cell |
Gel |
| Junction |
Type |
1 Ceramic Ø 1.2 mm |
| Tip |
Shape |
Sphere |
| Dimension |
Ø 5.0 mm |
| Plug |
Type |
DIN |
| Cable |
|
7 wire |
| Temp range °C |
0/+80 |
| Pressure PSI/BAR |
7.25/0.5 |
The new HI 991001 and HI 991002 meters from
Hanna offer IP 67 waterproof protection in a compact casing.
The included multi-parameter electrode has a built-in temperature sensor. No
additional temperature probe is required. The electrode also contains a mini
amplifier to render your measurements impervious to noise and electrical
interference. The large display shows readings in an extended range from -2.00
to 16.00 pH and simultaneously shows temperature from -5.0 to 105.0 °C or 23 to
221°F. HI 991002 also measures ORP from -1999 to 1999 mV. The mV scale of this
meter can be used with the available HI 1296D pH/temperature
electrode to check the condition of the pH electrode. These meters have a
stability indicator and hold feature that prompts you when to take the reading
& freezes the display for easy and accurate recording. The large display
also has graphic symbols to guide you through all operations. The battery life
of the meters guarantee over 1500 hours of continuous use. At startup, they
perform a self-check and then display the remaining battery level to assure
proper working condition. Calibration is performed automatically at one or two
points using standard or N.I.S.T. buffers.
HI 991001 is supplied complete with HI 1296D
pH/temperature electrode, 3 x 1.5V AA batteries and carrying case.
HI 991002 is supplied complete with HI 1297D
pH/ORP/temperature electrode, 3 x 1.5V AA batteries and carrying case.
| Specifications |
HI 991001 |
HI 991002 |
| Ranges: |
pH |
-2.00 to 16.00
|
-2.00 to 16.00 |
| |
ORP |
- |
±1999 mV |
| |
Temperature |
-5.0 to 105.0°C or 23.0 to 221.0°F
|
-5.0 to 105.0°C or 23.0 to 221.0°F |
| Resolution: |
pH |
0.01
|
0.01 |
| |
ORP |
- |
1 mV |
| |
Temperature |
0.1°C or 0.1°F
|
0.1°C or 0.1°F |
| Accuracy |
pH |
±0.02
|
±0.02 |
| (@20°C/68°F): |
ORP |
-
|
±2 mV |
| |
Temperature |
±0.5 up to 60°C, ±1°C up to 105°C
|
±0.5 up to 60°C, ±1°C up to 105°C |
| |
|
±1°F up to 140°F, ±2°F up to 221°F
|
±1°F up to 140°F, ±2°F up to 221°F |
| Typical EMC |
pH |
±0.02
|
±0.02 |
| Deviation: |
ORP |
- |
±2 mV |
| |
Temperature |
±0.2°C or ±0.4°F |
±0.2°C or ±0.4°F |
| pH Calibration |
Automatic 1 or 2 points with
2 set of standardized buffers |
| |
(4.01, 7.01, 10.01 or 4.01,
6.86, 9.18) |
| Temp. Compensation: |
Automatic from -5 to 105°C
(23 to 221°F) (for pH only) |
| Electrode: |
HI 1296D combination amplified
pH/temperature |
HI 1297D combination amplified pH/ORP/temperature |
| |
with DIN connector and 1 m (3.3’) cable
(included) |
with DIN connector and 1 m (3.3’) cable
(included) |
| Environment: |
0 to 50°C (32 to 122°F); RH
100% |
| Battery Type: |
3 x 1.5V AA |
| Battery Life: |
approximately 1500 hours of
continuous use. Auto-off after 8 minutes |
| Dimensions: |
150 x 80 x 36 mm (5.9 x 3.1 x
1.4”) |
| Weight: |
245 g (8.6 oz.) |
|
 |
HI 991003 - Portable pH Meter with Sensor Check
- Stability Indicator and Hold Feature insure proper readings
- Battery Life of over 1500 Hours
- Automatic Calibration using N.I.S.T
- Order Information
- Specifications
|
|
With today’s high level of demand for quality and accuracy, it is critical,
when measuring pH, to know the status of the electrode, since it is the most
important element of the pH measurement system. An old, out of specifications
pH electrode can result in erroneous pH measurements that can seriously damage
the process. Hanna Instruments has solved this problem with the unique sensor
check feature that allows the user to establish the status of the pH electrode
before performing measurements. The sensor check feature consists of a mV pH
scale that shows the characteristics (slope and offset) of the sensor, allowing
the user to determine if the electrode is in good condition. In several countries,
local agencies require pH electrodes to have slope % as high as 95%. This can
only be done with the sensor check feature.
HI 991003 is protected in a waterproof casing for use in humid
and wet environments. It also features a dual level LCD that displays pH or
ORP and temperature (in degree C or F). Automatic pH calibration can be performed
with 5 memorized buffers (for NIST or standard calibration).
HI 991003 provides over 1500 hours of battery life and an
8 minute auto-off period to save battery power.
HI 991003 is supplied complete with HI 1297D pH/ORP/temperature
electrode, 3 x 1.5V AA batteries, carrying case and instructions.
| Specifications |
HI 991404 |
| Ranges: |
pH |
-2.00 to 16.00 |
| |
pH (in mV) |
±825 mV |
| |
ORP |
±1999 mV |
| |
Temperature |
-5.0 to 105.0°C or 23.0 to 221.0°F |
| Resolution: |
pH |
0.01 |
| |
pH (in mV) |
1 mV |
| |
ORP |
1 mV |
| |
Temperature |
0.1°C or 0.1°F |
| Accuracy |
pH |
±0.02 |
| (@20°C/68°F): |
pH (in mV) |
±1 mV |
| |
ORP |
±2 mV |
| |
Temperature |
±0.5°C up to 60°C, ±1°C
up to 105°C |
| |
|
±1.0°F up to 140°F, ±2°F
up to 221°F |
| Typical EMC |
pH |
±0.02 |
| Deviation: |
pH (in mV) |
±2 mV |
| |
ORP |
±2 mV |
| |
Temperature |
±0.2°C or ±0.4°F |
| pH Calibration |
Automatic 1 or 2 points with 2 set of
standardized buffers |
| |
(4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) |
| Temp. Compensation: |
Automatic from -5 to 105°C (23 to
221°F) (for pH only) |
| Electrode: |
HI 1297D combination amplified pH/ORP/temperature
electrode |
| |
with DIN connector and 1 m (3.3’)
cable (included) |
| Environment: |
0 to 50°C (32 to 122°F); RH 100% |
| Battery Type: |
3 x 1.5V AA |
| Battery Life: |
approximately 1500 hours of continuous
use. Auto-off after 8 minutes |
| Dimensions: |
150 x 80 x 36 mm (5.9 x 3.1 x 1.4”) |
| Weight: |
245 g (8.6 oz.) |
Combination pH Electrode for HI
991002 & HI 991003
 |
| Code |
HI 1297D |
| Body |
Ultem® |
| Reference |
Junction |
Single |
| Cell |
Gel |
| Junction |
Type |
1 Ceramic Ø 1.2 mm |
| Tip |
Shape |
Conic Rod |
| Dimension |
Ø 3 mm |
| Plug |
Type |
DIN |
| Cable |
|
7 wire |
| Temp range °C |
0/+80 |
| Pressure PSI/BAR |
7.25/0.5 |
|
 |
HI 991001 & HI 991002
Extended Range Waterproof pH/ORP and Temperature Meters
- Stability Indicator and Hold Feature insure proper readings
- Battery Life of over 1500 Hours
- Automatic Calibration using N.I.S.T
- Order Information
- Specifications
|
|
The new HI 991001 and HI 991002 meters from
Hanna offer IP 67 waterproof protection in a compact casing.
The included multi-parameter electrode has a built-in temperature sensor. No
additional temperature probe is required. The electrode also contains a mini
amplifier to render your measurements impervious to noise and electrical interference.
The large display shows readings in an extended range from -2.00 to 16.00 pH
and simultaneously shows temperature from -5.0 to 105.0 °C or 23 to 221°F.
HI 991002 also measures ORP from -1999 to 1999 mV. The mV scale of this meter
can be used with the available HI 1296D pH/temperature electrode
to check the condition of the pH electrode. These meters have a stability indicator
and hold feature that prompts you when to take the reading & freezes the
display for easy and accurate recording. The large display also has graphic
symbols to guide you through all operations. The battery life of the meters
guarantee over 1500 hours of continuous use. At startup, they perform a self-check
and then display the remaining battery level to assure proper working condition.
Calibration is performed automatically at one or two points using standard
or N.I.S.T. buffers.
HI 991001 is supplied complete with HI 1296D pH/temperature
electrode, 3 x 1.5V AA batteries and carrying case.
HI 991002 is supplied complete with HI 1297D pH/ORP/temperature
electrode, 3 x 1.5V AA batteries and carrying case.
| Specifications |
HI 991001 |
HI 991002 |
| Ranges: |
pH |
-2.00 to 16.00
|
-2.00 to 16.00 |
| |
ORP |
- |
±1999 mV |
| |
Temperature |
-5.0 to 105.0°C or 23.0 to 221.0°F
|
-5.0 to 105.0°C or 23.0 to 221.0°F |
| Resolution: |
pH |
0.01
|
0.01 |
| |
ORP |
- |
1 mV |
| |
Temperature |
0.1°C or 0.1°F
|
0.1°C or 0.1°F |
| Accuracy |
pH |
±0.02
|
±0.02 |
| (@20°C/68°F): |
ORP |
-
|
±2 mV |
| |
Temperature |
±0.5 up to 60°C, ±1°C
up to 105°C
|
±0.5 up to 60°C, ±1°C
up to 105°C |
| |
|
±1°F up to 140°F, ±2°F
up to 221°F
|
±1°F up to 140°F, ±2°F
up to 221°F |
| Typical EMC |
pH |
±0.02
|
±0.02 |
| Deviation: |
ORP |
- |
±2 mV |
| |
Temperature |
±0.2°C or ±0.4°F |
±0.2°C or ±0.4°F |
| pH Calibration |
Automatic 1 or 2 points with
2 set of standardized buffers |
| |
(4.01, 7.01, 10.01 or 4.01,
6.86, 9.18) |
| Temp. Compensation: |
Automatic from -5 to 105°C
(23 to 221°F) (for pH only) |
| Electrode: |
HI 1296D combination amplified pH/temperature |
HI 1297D combination amplified pH/ORP/temperature |
| |
with DIN connector and 1 m (3.3’)
cable (included) |
with DIN connector and 1 m (3.3’)
cable (included) |
| Environment: |
0 to 50°C (32 to 122°F);
RH 100% |
| Battery Type: |
3 x 1.5V AA |
| Battery Life: |
approximately 1500 hours
of continuous use. Auto-off after 8 minutes |
| Dimensions: |
150 x 80 x 36 mm (5.9 x 3.1
x 1.4”) |
| Weight: |
245 g (8.6 oz.) |
|