Data Sheet
User Manual
|
|
SPECIFICATIONS |
OPERATION
MODE |
Independent |
Two
independent outputs and 5V fixed output
Output from 0 to rating volts and 0 to rating amperes |
| Series |
Output from
0 to + rating volts at rating amperes each
Output from 0 to double rating volts at rating amperes |
| Parallel |
Output from
0 to double rating amperes at rating volts |
|
5V FIXED
OUTPUT |
Regulation |
Line
regulation < 5mV
Load regulation < 10mV |
| Ripple
& Noise |
<
2mVrms |
| Voltage
Accuracy |
5V +
0.25V |
| Output
Current |
3A |
|
TRACKING
OPERATION |
Tracking
Error |
<
0.5% + 10mV of the master |
| Series
Regulation |
<
300mV |
|
CONSTANT
VOLTAGE
OPERATION |
Regulation |
Line
regulation < 0.01% + 3mV
Load regulation < 0.01% + 3mV (rating current <
3A)
< 0.02% + 5mV (rating current < 10A) |
| Ripple
& Noise |
<
1mVrms 5Hz ~ 1MHz |
| Recovery
Time |
<
100µS (50% Load change, Minimum load 0.5A) |
|
CONSTANT
CURRENT
OPERATION |
Regulation |
Line
regulation < 0.2% + 3mA
Load regulation < 0.2% + 3mA |
| Ripple
Current |
<
3mArms |
|
|
METER |
Digital |
3 1/2 digits
0.5" LED display
3 1/2 digits 0.39" LED display ( for GPC-3030DQ )
Accuracy + (0.5% of rdg + 2 digits) |
|
|
INSULATION
|
Chassis
and Terminal |
20MΩ or
above ( DC 500V ) |
| Chassis
and AC Cord |
30MΩ or
above ( DC 500V ) |
|
POWER
SOURCE |
AC
100V/120V/220V/240V+10%, 50/60Hz |
|
|
ACCESSORIES |
Instruction
manual x 1,
Power cord x 1
Test lead GTL-105 x 3 (<3A) or GTL-104 x 3 (<10A) |
|
|
DIMENSIONS |
255(W)
x 145(H) x 335(D) mm
|
| |
|
Model |
Independent |
Series |
Parallel |
| |
Digital
|
GPC-1850D |
0~18V
x 2, 0~5A x 2 |
36V
5A |
18V
10A |
| GPC-3020D |
0~30V
x 2, 0~2A x 2 |
60V
2A |
30V
4A |
| GPC-3030D |
0~30V
x 2, 0~3A x 2 |
60V
3A |
30V
6A |
| GPC-3030DQ |
0~30V
x 2, 0~3A x 2 |
60V
3A |
30V
6A |
Data Sheet
|
|
SPECIFICATIONS |
OPERATION MODE |
Independent |
Two independent outputs and 5V fixed output
Output from 0 to rating volts and 0 to rating amperes |
| Series |
Output
from 0 to + rating volts at rating amperes each
Output from 0 to double rating volts at rating amperes |
| Parallel |
Output
from 0 to double rating amperes at rating volts |
|
|
5V FIXED OUTPUT |
Regulation |
Line
regulation < 5mV
Load regulation < 10mV |
| Ripple
& Noise |
<
2mVrms |
| Voltage
Accuracy |
5V
+ 0.25V |
| Output
Current |
3A |
|
|
TRACKING OPERATION |
Tracking
Error |
<
0.5% + 10mV of the master |
| Series
Regulation |
<
300mV |
|
CONSTANT VOLTAGE
OPERATION |
Regulation |
Line
regulation < 0.01% + 3mV
Load regulation < 0.01% + 5mV (rating current < 10A)
< 0.02% + 5mV (rating current > 10A) |
| Ripple
& Noise |
<
1mVrms 5Hz ~ 1MHz |
| Recovery
Time |
<
100µS (50% Load change, Minimum load 0.5A) |
|
CONSTANT CURRENT
OPERATION |
Regulation |
Line
regulation < 0.2% + 3mA
Load regulation < 0.2% + 3mA |
| Ripple
Current |
<
3mArms |
|
|
METER |
Analog |
V-meter
and I-meter each one
2.5 class
Dimension 50 x 50 mm |
| Digital |
3
1/2 digits 0.5" LED display
Accuracy + (0.5% of rdg + 2 digits) |
|
|
INSULATION |
Chassis
and Terminal |
100MΩ
or above ( DC 1000V ) |
| Chassis
and AC Cord |
100MΩ
or above ( DC 1000V ) |
|
|
POWER SOURCE |
AC
100V/120V/220V/240V+10%, 50/60Hz |
|
|
ACCESSORIES |
Instruction
manual x 1,
Power cord x 1
Test lead GTL-105 x 3 (<3A) or GTL-104 x 3 (<10A) |
|
|
DIMENSIONS |
255(W)
x 145(H) x 420(D) mm |
| |
|
| |
|
| |
Model |
Independent |
Series |
Parallel |
|
Digital
|
GPC-6030D |
0~60V
x 2, 0~3A x 2 |
120V
3A |
60V
6A |
| GPC-3060D |
0~30V
x 2, 0~6A x 2 |
60V
6A |
30V
12A |
D.C.
POWER SUPPLY (100 ~ 200VA)
 |
|
|
|
0.01% High Regulation
|
Constant Voltage and Constant Current Operation
|
Internal Select for Continuous or Dynamic Load
|
Low Ripple and Noise
|
Overload and Reverse Polarity Protection
|
3 1/2 Digits 0.5" LED Display
|
Data Sheet
User Manual
|
|
SPECIFICATIONS |
CONSTANT VOLTAGE
OPERATION |
Regulation |
Line regulation < 0.01% + 3mV |
| Load
regulation < 0.01% + 5mV ( < 10A) |
|
< 0.02% + 5mV ( > 10A) |
| Ripple
& Noise |
<
1mVrms 5Hz ~ 1MHz |
| Recovery
Time |
<
100µS (50% Load change, Minimum load 0.5A) |
| Output
Range |
0
to rating voltage continuously adjustable |
|
CONSTANT CURRENT
OPERATION |
Regulation |
Line
regulation < 0.2% + 3mA
Load regulation < 0.2% + 3mA |
| Ripple
Current |
<
3mArms |
| Output
Range |
0
to rating amperes continuously adjustable |
|
|
METER |
Analog |
V-meter
and I-meter each one
2.5 class
Dimension 60 x 80 mm |
| Digital |
3
1/2 digits 0.5" LED display
Accuracy + (0.5% of rdg + 2 digits) |
|
|
INSULATION |
Chassis
and Terminal |
20MΩ
or above ( DC 500V ) |
| Chassis
and AC Cord |
30MΩ
or above ( DC 500V ) |
|
|
POWER SOURCE |
AC
100V/120V/220V/240V+10%, 50/60Hz |
|
|
ACCESSORIES |
Instruction
manual x 1,
Power cord x 1
Test lead GTL-105 x 1 (<3A) or GTL-104 x 1 (<10A) |
|
|
DIMENSIONS |
255(W)
x 145(H) x 335(D) mm |
| |
|
| |
|
| |
Model |
Output
Volts (V) |
Output
Amps (A) |
| Digital |
GPR-1810HD |
0
~ 18 |
0
~ 10 |
| GPR-3060D |
0
~ 30 |
0
~ 6 |
| GPR-6030D |
0
~ 60 |
0
~ 3 |
Data Sheet
User Manual
|
|
SPECIFICATIONS |
CONSTANT VOLTAGE
OPERATION |
Regulation |
Line regulation < 0.01% + 3mV |
| Load
regulation < 0.01% + 5mV ( < 10A) |
|
< 0.02% + 5mV ( > 10A) |
| Ripple
& Noise |
<
1mVrms 5Hz ~ 1MHz |
| Recovery
Time |
<
100µS (50% Load change, Minimum load 0.5A) |
| Output
Range |
0
to rating voltage continuously adjustable |
|
CONSTANT CURRENT
OPERATION |
Regulation |
Line
regulation < 0.2% + 3mA
Load regulation < 0.2% + 3mA |
| Ripple
Current |
<
5mArms(<20A), < 20mArms(<50A) |
| Output
Range |
0
to rating amperes continuously adjustable |
|
|
METER |
Digital |
3
1/2 digits 0.5" LED display
Accuracy + (0.5% of rdg + 2 digits) |
|
|
INSULATION |
Chassis
and Terminal |
100MΩ
or above ( DC 1000V ) |
| Chassis
and AC Cord |
100MΩ
or above ( DC 1000V ) |
|
|
POWER SOURCE |
AC
100V/120V/220V/240V+10%, 50/60Hz |
|
|
ACCESSORIES |
Instruction
manual x 1,
Power cord x 1
Test lead GTL-105 x 1(<3A) or GTL-104 x 1(<10A)
or Not Available >10A |
|
|
DIMENSIONS |
255(W)
x 145(H) x 420(D) mm |
| |
Model |
Output
Volts (V) |
Output
Amps (A) |
|
Digital
|
GPR-0830HD |
0 ~ 8 |
0 ~ 30 |
| GPR-1820HD |
0 ~ 18 |
0 ~ 20 |
| GPR-3510HD |
0 ~ 35 |
0 ~ 10 |
| GPR-6060D |
0 ~ 60 |
0 ~ 6 |
| GPR-7550D |
0 ~ 75 |
0 ~ 5 |
| GPR-11H30D |
0 ~ 110 |
0 ~ 3 |
| GPR-30H10D |
0
~ 300 |
0
~ 1 |
|
CE APPROVED:GPR-1820HD,
GPR-3510HD, GPR-7550D, GPR-11H30D
|
Data
Sheet
User
Manual
Programmer
Manual
|
|
SPECIFICATIONS |
| |
MODEL
|
PST-3202
|
PST-3201 |
|
Output |
Voltage |
0~32V
x 2, 0~6V x 1 |
0~32V
x 3 |
| Current |
0~2A
x 2, 0~5A x 1 |
0~1A
x 3 |
| OVP |
0~33V
x 2, 0~7V x 1 |
0~
33V x 3 |
|
|
Load Effect |
Voltage |
<
3mV
|
| Current |
<
3mA
|
|
|
Source Effect |
Voltage |
<
3mV
|
| Current |
<
3mA
|
|
|
Resolution |
Voltage |
10mV
( 20mV rating voltage > 36V ) |
| Current |
1mA
( 2mA rating current > 3.5A ) |
| OVP |
10mV
( 20mV rating voltage > 36V ) |
|
Program Accuracy
( 25 +
5°C ) |
Voltage |
<
0.05% + 20mV ( +40mV rating voltage > 36V ) |
| Current |
<
0.1% + 5mA ( +10mV rating voltage > 3.0A ) |
| OVP |
<
0.05% + 20mV ( +40mV rating voltage > 36V ) |
|
Ripple & Noise
( 20Hz ~ 20MHz ) |
Voltage |
Ripple:<
1mVrms / 3mVp-p
Noise:< 2mVrms /
30mVp-p |
| Current |
<
3mArms ( < 5mArms rating current > 3.5A ) |
|
|
Temperature |
Voltage |
<
100ppm + 3mV |
|
Coefficient( 0 ~ 40°C ) |
Current |
<
100ppm + 3mA |
|
|
Read back Resolution |
Voltage |
10mV
( 20mV rating voltage > 36V ) |
| Current |
1mA
( 2mA rating current > 3.5A ) |
|
Read back Accuracy
( 25 + 5°C ) |
Voltage |
<
0.05% + 10mV ( + 20mV rating voltage > 36V ) |
| Current |
<
0.1% + 5mA |
|
|
Read back Temperature |
Voltage |
<
100ppm + 10mV ( + 20mV rating voltage > 36V ) |
|
Coefficient |
Current |
<
150ppm + 10mA |
|
|
Response Time |
Voltage
Up |
10%
~ 90%:< 100mS |
| Voltage
Down |
90%
~ 10%:< 100mS |
|
|
Drift |
Voltage |
<
100ppm + 10mV ( + 20mV rating voltage > 36V ) |
| Current |
<
150ppm + 10mA |
|
Track Operation
|
Tracking
Error |
<
0.1% + 20mV |
Series
(Load Effect) |
<
20mV |
|
Parallel Operation
|
Program
Accuracy
( 25 + 5°C ) |
Voltage:<
0.05% + 10mV ( + 20mV rating voltage > 36V ) |
Current:<
0.1% + 10mA
OVP:< 0.05% + 10mV |
|
Memory
|
Store/Recall
Points 0 ~ 99 |
|
Timer
|
Setting
Time |
0.1sec
~ 99Min59sec (max. 99Min59sec x 100) |
| Resolution |
0.1sec |
| Function |
Auto
Step running (for output working loop) |
|
|
Interface (Standard) |
RS-232 |
|
|
Interface (Option) |
GPIB
(IEEE 488.2) |
|
|
Power Source |
AC
100V/120V/220V/240V+10%, 50/60Hz |
|
|
Accessories |
Power
cord x 1,
Instruction manual x 1,
Test Lead x 3 sets |
|
|
Dimensions & Weight |
230(W)
x 140(H) x 380(D) mm, Approx. 10 kg |