Dwyer Series
DMF
Digital Mass Flow Controllers
Programmable, RS485 Interface, Up to 500 psig, ±1% Accuracy

Service Manual
Catalog Page

Dimensional Enlargement

Program, record, analyze, and control flow rates of various gases with Series DMF Digital Mass Flow Controller. Controllers are designed with straight tube sensors with restrictor flow elements to ensure laminar gas flow for accurate and repeatable results. Series DMF are unaffected by temperature and pressure variations.

Controllers can be programmed for various control functions including flow set point, totalizer, stop totalizer, totalize from preset flow, stop and preset total, auto zero, and more. Auto zero feature utilizes an automatic balancing circuit that virtually eliminates drift of zero and span. In addition, Series DMF controllers have two dry contact closures to operate pumps, valves, or other process equipment.

The Series DMF features an auto tune function to optimize control response for a specific gas under actual process conditions. Self diagnostic tests are run at power up to ensure the controller is in optimum working condition. Calibration information for up to 10 gases and conversion factors for up to 256 different gases are stored in memory. High and low gas flow alarm limits are programmed via RS-485 interface. Software supports programmable flow modes, allowing execution of custom programming of up to ten steps.

POPULAR MODELS
Model
Number
Range Price
 DMF-41401*  0 to 10 sccm   $1200.00
 DMF-41402*  0 to 20 sccm   $1200.00
 DMF-41403*  0 to 50 sccm   $1200.00
 DMF-41404*  0 to 100 sccm   $1200.00
 DMF-41405*  0 to 200 sccm   $1200.00
 DMF-41406*  0 to 500 sccm   $1200.00
 DMF-41407*  0 to 1 L/min   $1200.00
 DMF-41408*  0 to 2 L/min   $1200.00
 DMF-41409*  0 to 5 L/min   $1200.00
 DMF-41411*  0 to 15 L/min   $1200.00
 DMF-41431*  0 to 30 L/min   $1300.00
 DMF-41433*  0 to 50 L/min   $1300.00
 DMF-48442*  0 to 100 L/min   $1400.00
*Specified flow ranges are for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.

SPECIFICATIONS
Accuracy: ±1% FS including linearity between 59 to 77°F (15 to 25°C) and 10 to 60 psia (0.7 to 4 bar); ±2% FS from 32 to 122°F (0 to 50°C) and 5 to 150 psia (0.3 to 10 bar).
Repeatability: ±0.15% of full scale.
Temperature Limits: 41 to 122°F (5 to 50°C).
Pressure Limits: 500 psig (34.5 bar).
Response Time: 0.6 to 1.0 second to within ±2% of setpoint over 20% to 100% FS.
Power Supply: ±15 VDC; 13.5 Watts maximum.
Output: Linear 0-5 VDC (2000 Ω min. load impedance); 0-10 VDC (4000 Ω min. load impedance).
Temperature Coefficient: 0.05% FS/°C or better.
Pressure Coefficient: 0.01% FS/psi (0.07 bar) or better.
Leak Integrity: 1 x 10-9 sccs of Helium.
Maximum Particulate Size: 100 microns.
Computer Interface: RS-485.
Process Connections: 1/4" compression fitting for flow rates ≤50 L/m; 3/8" for flows ≥60 L/m.
Wetted Materials: 316 stainless steel, 416 Stainless steel, Viton® O-rings

 

ACCESSORIES
Model
Number
Description Price
 DMF-110P  110V Power Supply with 25-pin connector   $300.00
 DMF-220PE  20V Power Supply with 25-pin connector   $300.00
 DMF-CBL1  6 ft cable with branch to separate power supply   $57.00
 DMF-CBL2  6 ft cable with branch to computer port   $25.00

 

Dwyer Series
GFT
Flow Totalizer
Seven Digit Display, Easy Installation

Service Manual
Catalog Page

Dimensional Enlargement

Series GFT Flow Totalizer is designed to be used with mass flowmeters and mass flow controllers. The totalizer accepts analog output flow signals of either 0 to 5 VDC or 5 to 10 VDC. Series GFT integrates and accumulates up to 7 digits of direct engineering units for a given gas and flow rate (standard liters, standard cubic centimeters, etc.). Quickly connect the totalizer to Series GFC and GFM mass flow controllers and meters via the modular jack (replacing the LCD display) or use the optional cable to connect in parallel with the display.

POPULAR MODELS
Model
Number
Description Price
 GFT-05  Accepts 0 to 5 VDC input   $185.00
 GFT-10  Accepts 0 to 10 VDC input   $185.00


Dwyer Series
GFC/GFM
Gas Mass Flow Controllers/Meters
Flow Range up to 1000 L/min, Pressures up to 500 psi, NIST Traceable

Service Manual(GFC)
Catalog Page
Gas Mass Flow Controllers
Dimensional Enlargement
Gas Mass Flow Meters
Service Manual(GFM)
Catalog Page

Dimensional Enlargement

Series GFC/GFM Gas Mass Flow Controllers/Meters combine a straight tube sensor with a restrictor flow element to provide high accuracy and repeatability. Flow rates are virtually unaffected by temperature and pressure variations. Actual gas flow is displayed in engineering units on a 3-1/2 digit, 90° tiltable LCD readout. Units can be used with Series GFT Flow Totalizer for applications requiring totalization. Series GFC/GFM includes a NIST traceable certificate. Gas mass flow controllers utilize an electromagnetic valve and PID electronics to maintain continuous control by comparing measured sensor signal set to flow rates. Setpoints can be adjusted with local potentiometers or remotely via 0 to 5 VDC or 4 to 20 mA analog signal.
POPULAR MODELS
Model
Number
Flow Range Price
 GFC-1101  0-10 sccm   $775.00
 GFC-1102  0-20 sccm   $775.00
 GFC-1103  0-50 sccm   $775.00
 GFC-1104  0-100 sccm   $775.00
 GFC-1105  0-200 sccm   $775.00
 GFC-1106  0-500 sccm   $775.00
 GFC-1107  0-1 L/min   $775.00
 GFC-1108  0-2 L/min   $775.00
 GFC-1109  0-5 L/min   $775.00
 GFC-1111  0-15 L/min   $775.00
 GFC-1131  0-30 L/min   $940.00
 GFC-1133  0-50 L/min   $940.00
 GFC-1142  0-100 L/min   $1090.00
 GFC-1143  0-200 L/min   $1235.00
 GFC-1144  0-500 L/min   $1430.00
 GFC-1145  0-1000 L/min   $1820.00

 

POPULAR MODELS
Model
Number
Flow Range Price
 GFC-2101  0-10 sccm   $940.00
 GFC-2102  0-20 sccm   $940.00
 GFC-2103  0-50 sccm   $940.00
 GFC-2104  0-100 sccm   $940.00
 GFC-2105  0-200 sccm   $940.00
 GFC-2106  0-500 sccm   $940.00
 GFC-2107  0-1 L/min   $940.00
 GFC-2108  0-2 L/min   $940.00
 GFC-2109  0-5 L/min   $940.00
 GFC-2111  0-15 L/min   $940.00
 GFC-2131  0-30 L/min   $1140.00
 GFC-2133  0-50 L/min   $1140.00
 GFC-2142  0-100 L/min   $1290.00
 GFC-2143  0-200 L/min   $1900.00
 GFC-2144  0-500 L/min   $2200.00
 GFC-2145  0-1000 L/min   $2800.00

 

*Specified ranges are for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.

ACCESSORIES

Model
Number
Description Price
 GFC-110P  110V Power Supply   $60.00
 GFC-220PE  220V Power Supply   $70.00
 GFM-CBL1  8 ft cable with 15 pin connector   $45.00
 GFM-CBL3  3 ft extension cable for LCD readout   $25.00
 IO-1  0-5 VDC to RS232 Input to Output Signal Conditioner   $250.00

Dwyer Series
MF & MFC
Mass Flowmeters and Controllers
Integral Display, Adjustable Zero and Span

Service Manual (Series MF)
Service Manual (Series MFC)
Catalog Page

Series MFC
Dimensional Enlargement

Series MF
Dimensional Enlargement

Measure, Monitor and Control gas mass flow rates reliably with Series MF Thermal Mass Flowmeters and Series MFC Thermal Mass Flow Controllers. These units provide an accurate measurement of gas mass flow rate independent of changes in pressure or temperature. Actual gas mass flow rate is continuously displayed on a 3½ digit LCD readout.

POPULAR MODELS
Model
Number
Flow Range* Price
 MF1100002  0 to 20 SCCM   $565.00
 MF1100003  0 to 50 SCCM   $510.00
 MF1100004  0 to 100 SCCM   $510.00

*Specified flow ranges are for an equivalent flow of nitrogen at 70°F (21 °C) @ 760 mm Hg.

POPULAR MODELS
Model
Number
Flow Range* Price
 MFC1101  0 to 10 SCCM   $955.00
 MFC1102  0 to 20 SCCM   $955.00
 MFC1103  0 to 50 SCCM   $915.00
 MFC1104  0 to 100 SCCM   $915.00

 

SPECIFICATIONS
Service: Clean gases compatible with wetted parts.
Transducer Input Power: Series MF: 12 to 18 VDC; 15 VDC nominal ±10%; Series MFC: 15 to 24 VDC, ±10%.
Accuracy: ±1.5% FS including linearity over 15 to 25°C and 5 to 60 psia.
Repeatability: Series MF: ±0.5% FS; Series MFC: ±0.25% full scale.
Control Range (Series MFC only): 5 to 100% full scale.
Temperature Coefficient: Series MF: 0.15% FS per °C, or better; Series MFC: 0.08% FS per °C,or better.
Pressure Coefficient: 0.02% FS per psi (0.07 kg/cm²), or better.
Response Time: Series MF: 2 seconds within 2% final flow; Series MFC: 2 seconds within 63% of set point.
Pressure Limits: 150 psig (10 bar).
Temperature Limits: 32 to122°F (0 to 50°C).
Leak Integrity: 1 x 10-4 SCCS of helium max. to outside environment.
Output Signal: Series MF: Linear, 0 to 5 VDC; Series MFC: Linear, 4-20 mA into 1000Ω max. Ioad resistance, or 0-5 VDC.
Wetted Materials: Glass-filled Nylon® 316 SS, nickel plating, and Viton® O-rings.
Inlet/Outlet Connection: ¼" Female NPT.
Shipping Weight: Series MF: 3 lbs. (1.4 kg); Series MFC: 3.5 Ibs. (1.6 kg).


Dwyer Series
UF
Sonicflow Flowmeters
Non-Invasive, Flow Rate and Total Flow Indication, ±2% Accuracy, Portable

Catalog Page

Dimensional Enlargement

The Portable Series UF Sonicflow Flowmeters are non-invasive “transit time” ultrasonic flowmeters designed to help service/maintenance and commissioning engineers take quick, accurate flow readings. Flow rates from 0.07 to 26 ft/sec (0.02 to 8 m/sec) of almost any clear or cloudy liquid can be measured with ±2% accuracy. Easy to install flow transducers mount directly to a variety of pipe materials such as stainless steel, cast iron, ductile iron, PVC, copper, and concrete with diameters of 2" to 8½".

Set up is simple using the 15 key tactile membrane. Program flow rate indication in GPM, LPM, ft/sec, or m/s and display total flow in gallons or liters. Flowmeter includes transducer assembly, interconnecting cable, couplant, batteries, universal mains supply, case, and instruction manual.

POPULAR MODELS
Model
Number
Description Price
 UF20A  Sonicflow Flowmeter   $2875.00

SPECIFICATIONS
Range: 0.07 to 26 ft/sec (0.02 to 8 m/s).
Pipe Range: 2" to 8½". (50 to 215 mm) nominal bore.
Accuracy: ±2% of reading.
Repeatability: ±0.5% or ±0.1 LPM (whichever is greater).
Response Time: < 2 seconds.
Display Resolution: 0.1% of reading.
Display: 7-digit flow rate in GPM, LPM, LPS, m³/s, ft/sec and m/s; 7-digit totalization in gallons liters, or m³.
Temperature Limits: 32 to 113°F (0 to 45°C).
Storage Temperature: -4 to 131°F (-20 to 55°C).
Transducer Operating Temp: -4 to 212°F (-20 to 100°C).
Power: Two AA batteries or 110/240V, 50/60Hz mains supply.
Guide Rail Length: 8.25" x 1.4" x 1.06" (210 x 36 x 27 mm).
Cable Length: 6.5 feet (2 m).
Housing: Polymide PA6, IP55 rating.
Weight: 17.5 oz (500 g) including transducers.

Dwyer Model
UF10A/
UF35
Sonicflow Flowmeters
Non-Invasive, Flow Rate and Total Flow Indication, ±2% Accuracy, Portable

Catalog Page

Dimensional Enlargement

The Portable Series UF Sonicflow Flowmeters are non-invasive "transit time" ultrasonic flowmeters designed to help service/maintenance and commissioning engineers take quick, accurate flow readings. Flow rates from 1.6 to 26 ft/sec (0.5 to 8 m/sec) for UF35; 0.13 to 26 ft/sec (0.04 to 8 m/sec) for UF10A, of almost any clear or cloudy liquid can be measured with ±2% accuracy. Easy to install flow transducers mount directly to a variety of pipe materials such as stainless steel, cast iron, ductile iron, PVC, copper, and concrete with diameters of 1/2" to 4-1/2" using Model UF10A or 2" to 15.75" using Model UF35.

Set up is simple using the 15 key tactile membrane. Program flow rate indication in GPM, LPM, ft/sec, or m/s and display total flow in gallons or liters. Flowmeter includes transducer assembly, interconnecting cable, couplant, batteries, universal mains supply, case, and instruction manual.

POPULAR MODELS
Model
Number
Description Price
 UF10A  Sonicflow Flowmeter   $1995.00
 UF35  Sonicflow Flowmeter   $2995.00

SPECIFICATIONS
Range: UF10A: 0.13 to 26 ft/sec (0.04 to 8 m/s. UF35: 1.6 to 26 ft/sec (0.5 to 8 m/s).
Pipe Range: UF10A: 1/2" to 4-1/2" (13 to 115mm) nominal bore. UF35: 2" to 15.75" (50 to 400mm) nominal bore.
Accuracy: ±2% of reading.
Repeatability: ±0.5% or ±0.1 LPM (whichever is greater).
Display: 7-digit flow rate in GPM, LPM, LPS, m³/s, ft/sec and m/s; 7- digit totalization in gallons, liters, or m³.
Display Resolution: 0.1% of reading.
Response Time: < 2 seconds.
Operating Temperature: 32 to 113°F (0 to 45°C).
Storage Temperature: -4 to 131°F (-20 to 55°C).
Transducer Operating Temp: -4 to 257°F (-20 to 125°C).
Power: Four AA rechargeable batteries.
Guide Rail Length: UF35:15.6" x 1.3" x 1.7" (395 x 33 x 42mm). UF10A: 8.25" x 1.4" x 1.06" (210 x 36 x 27mm).
Cable Length: 6.5 feet (2 m).
Housing: ABS, IP55 rating.
Weight: 17.5 oz (500 g) including transducers.

 

 

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117