F W Bell Current Measurement
F W Bell Gun Series Meters
& Probes
 |
| Current
Meter Model mA-2000- ( fwb2000 ) |
| Description Advanced
patent pending design accurately measures DC and AC currents
from 0-2000mA |
|

Price - $995.00
CE Model Available
Description
Advanced patent pending design accurately measures DC and
AC currents from 0 to 2000 mA. Simply clamp the retractable probe on the conductor being
measured without breaking the circuit. Easy-to-read 31/2 digit LCD. An analog output is
provided for connection to an oscilloscope. Comes complete with batteries, optional
battery eliminator, hard carrying case and instructions. |
SPECIFICATIONS:
Features
- Measures low level DC & AC currents from 0 to 2000 mA
with resolution as low as 0.1mA
- Basic DC accuracy of 1% of reading
- True RMS measurement
- Frequency range DC to 250 kHz
- Built in 31/2 digit display
- BNC analog output for connection to oscilloscope or recorder
- Simple clamp-on operation
- Supplied with optional AC power adapter and hard carrying
case
Typical Applications
- Troubleshooting 4-20 mA control loops
- Isolating faults on electronic circuits
- Verification of power supply currents
- Automotive computer control diagnostics
- Measuring ground current
- Low current measurements in R&D laboratories
Specifications |
 |
|
|
| Range |
|
| Low |
0-200 mA (DC or RMS AC) |
| High |
0-2000 mA (DC or Peak AC) |
| Resolution |
|
| Low Range |
0.1 mA |
| High
Range |
1 mA |
| Frequency Range |
dc to 100 kHz |
| ac Low |
dc to 200 Hz |
| ac High |
200 Hz to 100 kHz |
| -3 dB |
250 kHz |
| Output |
|
| Analog |
1 mV/mA |
| Connection |
BNC |
| Accuracy |
|
| dc |
1% of reading |
| ac - up
to 200 Hz |
2% of reading |
| Repeatability |
0.5% of reading |
| Readout |
3 1/2 digit LCD |
|
 |
|
|
| Output (Analog) |
1 mV/mA |
| Output (Connector) |
BNC |
| Output (Noise) |
<100uV RMS |
| Influences On Accuracy |
|
|
Temperature Coefficient |
0.01%/oC |
| Adjacent
Conductor |
<100uA/A |
|
 |
|
|
| Operating Temperature |
0oC to 50oC |
| Storage Temperature Range |
-25oC to + 70oC |
| Battery |
Two 9V Alkaline (NEDA 1640 A) |
| Battery Life (Typical) |
15 hours |
| Safety |
IEC 1010 Cat 2 300 V Pollution degree 2 |
| Aperature Size |
0.21 inches (5.3 mm) |
| Size |
|
| Probe
Dimensions: |
Meter Dimensions: |
| 6.25
inches (15.9 cm) length |
5.2 inches (13.2 cm) length |
| 1.2
inches (3.0 cm) diameter |
5.3 inches (13.5 cm) width 1.5 inches (3.8 cm) height |
|
|
F W Bell Gun Series Meters & Probes
Y8100 AC/DC Current
Probe
Open Loop Current Sensors
Model CLN-25 Closed Loop Hall Effect
Model CLN-50/100 Closed Loop Hall
Effect
Model CLN-50/100SP1 Closed Loop
Hall Effect
Model CLN-300/500 Closed Loop
Hall Effect
Model CLN-300SP1/500SP1 Closed
Loop Hall Effect
Model CLO-300/500 Closed Loop Hall
Effect
Model CS-150 and CSS-150 Current
Switches
| The Current Gun Series of hand-held,
noncontact Meter and Probes has been Discontinued. We suggest you go to
the following page for possible
replacements Specifications
Model CG-100D
- *3-1/2 digit LCD with 5 second readout hold
- dc/ac Current Range: ±200 A FS
- Basic Accuracy: ± 0.75% F.S. to 100A, ± 3% of
reading, 100A to 200A
- Analog Output: ±2.0V/200A, ±1.0% of reading (plus above
stated accuracy)
- Frequency Response: dc to 1 kHz (readout ac mode 20 Hz to 1
kHz)
Model CG-120A
- dc/ac Current Ranges: ±50A FS, ±500A FS
- Basic Accuracy: ±5% of reading
- Overange Capability: 50 A Range-300% (150A) Accuracy stated
above plus ±1% of reading, 500 A range-None
- Analog Output: ±0.5V/50A ±0.5V/500A
- Frequency Response: dc to 1 kHz
Model CG-100A
- dc/ac Current Ranges: ±10A FS, ±100A FS
- Basic Accuracy: >100A, ±2.0% FS ± 0.9A, ±3.0% of
overrange,± 0.9A
- 65 Hz-1 kHz, 100A add ±6% of reading
- Analog Output: ±1.0V/10A, ±1.0V/100A
- Frequency Response: dc to 1 kHz
CA Series has been
Discontinued. We suggest you go to the following page for possible
replacements
|
|
Y8100 has been Discontinued.
We suggest you go to the following page for possible
replacements
Description
The F.W. Bell Y8100 is an exact replacement
for the Fluke Model Y8100 clamp-on current probe. It can be used with a digital
multimeter or oscilloscope to measure dc, ac or composite (ac/dc) currents. The
ergonomic pistol shape sets the standard for hand-held comfort. Two ranges, 20 A and 200
A, produce a 2 V output at full current range. An indicator light turns on when the
battery voltage is too low for proper operation.
SPECIFICATIONS:
|

|
| Ranges |
|
| Low |
20 A ac or dc |
| High |
200 A ac or dc |
| Full Scale Output |
2V |
| Basic Accuracy |
|
| DC to 65
Hz |
<100 A: +2% of
range >100 A: +3%
of range |
| 65 Hz to
100 Hz |
<100 A: add +3% of reading >100 A: add +6% of range |
| Calibration cycle |
1 year |
| Frequency response |
dc to 1 kHz |
| Recommended load |
> 1 mW, 100 pF |
| Temparature range |
+15oC to +35oC for
specified accuracy -10oC to +50oC
for storage & operation at reduced accuracy |
| Voltage rating |
|
| Core to
ouput |
600 Vdc or 480 Vac |
| Output to
ground |
42 Vdc or 30 Vac |
| Aperature Size |
0.75 inches (19 mm) diameter |
| Weight |
14 ounces with batteries |
| Batteries |
four "AA" cells |
| Battery Life |
Alkaline: 20 hours continuous |
| Case |
MaterialFrame retardant ABS plastic |
| Color |
Black |
|
|
Description
- Measures ac and dc currents
- No dc insertion loss
- Provides electrical isolation
- Low operating power
- Low Cost
|
|
Speifications
| Model |
Rated |
Full Scale Output (V) |
Linearity +% Full Scale |
Frequency Range |
Aperture Inches (mm) |
Mounting |
| NA-25 |
25 |
.0225 to .0625 |
1 |
dc to 1 kHz |
.2 (5.1) |
PCB |
| NAP-25 |
25 |
.0225 to .0625 |
1 |
dc to 1 kHz |
PCB connections |
PCB |
| BB-25 |
25 |
1 |
1 |
dc to 60 kHz |
0.4 (10.2) |
PCB |
| BB-100 |
100 |
5 |
1 |
dc to 60 kHz |
0.4 (10.2) |
PCB |
| BB-150 |
150 |
6 |
0.6 |
dc to 60 kHz |
0.8 (20.3) |
Panel |
| BB-300 |
300 |
6 |
0.7 |
dc to 10 kHz |
0.8 (20.3) |
Panel |
| BB-600 |
600 |
6 |
1.25 |
dc to 10 kHz |
0.8 (20.3) |
Panel |
| BBP-150F |
150 |
6 |
0.6 |
dc to 60 kHz |
0.8 (20.3) |
Panel/Flat |
| BBP-300F |
300 |
6 |
0.7 |
dc to 10 kHz |
0.8 (20.3) |
Panel/Flat |
| BBP-600F |
600 |
6 |
1.25 |
dc to 10 kHz |
0.8 (20.3) |
Panel/Flat |
| BBP-150H |
150 |
6 |
0.6 |
dc to 60 kHz |
0.8 (20.3) |
Panel/Horizontal |
| BBP-300H |
300 |
6 |
0.7 |
dc to 10 kHz |
0.8 (20.3) |
Panel/Horizontal |
| BBP-600 |
600 |
6 |
1.25 |
dc to 10 kHz |
0.8 (20.3) |
Panel/Horizontal |
| IHA-25 |
25 |
1 |
1 |
dc to 50 kHz |
0.38 (9.6) |
PCB/Panel |
| IHA-100 |
100 |
5 |
1 |
dc to 50 kHz |
0.38 (9.6) |
PCB/Panel |
| IHA-150 |
150 |
5 |
1 |
dc to 50 kHz |
0.84 (21.3) |
PCB/Panel |
| PI |
350 |
0.175-0.385 |
1.5 |
dc to 1 kHz |
0.8 (20.3) |
PCB |
| PI-600 |
600 |
0.150-0.330 |
2 |
dc to 1 kHz |
0.8 (20.3) |
PCB |
| IA-0100
|
100 |
10 |
0.5 |
dc only |
.67 (42.4) |
Panel |
| IA-0250 |
250 |
10 |
0.5 |
dc only |
.67 (42.4) |
Panel |
| IA-0500 |
500 |
10 |
0.5 |
dc only |
.67 (42.4) |
Panel |
| IA-1000 |
1000 |
10 |
0.5 |
dc only |
.67 (42.4) |
Panel |
| A-2000 |
2000 |
10 |
0.5 |
dc only |
.67 (42.4) |
Panel |
| IA-3000 |
3000 |
10 |
0.5 |
dc only |
.67 (42.4) |
Panel |
| IF-0100 |
100 |
10 |
0.5 |
dc to 1 kHz |
.67 (42.4) |
Panel |
| IF-0250
|
250 |
10 |
0.5 |
dc to 1 kHz |
.67 (42.4) |
Panel |
| IF-0500 |
500 |
10 |
0.5 |
dc to 1 kHz |
.67 (42.4) |
Panel |
| IF-1000 |
1000 |
10 |
0.5 |
dc to 1 kHz |
.67 (42.4) |
Panel |
| IF-2000 |
2000 |
10 |
0.5 |
dc to 1 kHz |
.67 (42.4) |
Panel |
| IF-3000 |
3000 |
10 |
0.6 |
dc to 1 kHz |
.67 (42.4) |
Panel |
|
Description:
The Model CLN-25 is a closed loop Hall effect
current sensor that accurately measures dc and ac currents and provides electrical
isolation between the current carrying conductor and the output of the sensor. |

|
| Electrical Specifications |
|
|
| Nominal current (IN) |
25 Ampere turns rms |
|
| Measuring range * |
0 to 36 Ampere turns (A.t.) |
|
| Sense resistor |
R. min. |
R. max. |
| with ±
12 V at 25 A.t. peak |
100 ohms |
200 ohms |
|
at 36 A.t. peak |
100 ohms |
140 ohms |
| with ±
15 V at 25 A.t. peak |
100 ohms |
320 ohms |
|
at 36 A.t. peak |
100 ohms |
190 ohms |
| Nominal analog output current |
25 mA |
|
| Turns ratio |
1-2-3-4-5:1000 |
|
| Overall accuracy at 25 °C and
±12 V |
± 0.7% of IN |
|
| Overall accuracy at 25 °C and ±
15 V |
± 0.5% of IN |
|
| Supply voltage (Vdc) |
± 12 to ± 15 (± 5%) |
|
| Dielectric strength |
between the current carrying conductor and the
output of the sensor: 5 kV rms/50 Hz/1 min. |
|
| Accuracy-Dynamic Performance |
Typical |
Max. |
| Zero current offset at 25 °C (±
15V) |
± 0.05 mA |
± 0.15 mA |
| Residual current offset after an
overload of 3 x IN |
± 0.05 mA |
± 0.15 mA |
| Offset current temperature drift
(± 15V) |
|
|
| (between
0 °C and +25 °C) |
± 0.06 mA |
± 0.25 mA |
|
(between +25 °C and +70 °C) |
± 0.1 mA |
± 0.35 mA |
| Linearity |
better than ±0.2% |
|
| Response time |
less than 1 µs |
|
| di/dt accurately followed |
better than 50 A/µs |
|
| Bandwidth |
0 to 150 kHz (- 1 dB) |
|
| General Information |
|
| Operating temperature |
-40 °C to +85 °C |
| Storage temperature |
-40 °C to +90 °C |
| Current drain 10 |
mA (at ± 15 V) plus output current |
| Coil resistance |
110 ohms (at 70 °C) |
| Package |
Flame retarded plastic case |
| Weight |
16 grams |
| Mounting: |
Designed to mount directly on PCB via through
hole connection pins |
| Output reference |
better than 50 A/µs |
| Bandwidth |
To obtain a positive output on the terminal
marked "O/P", current must flow from terminals 1,2,3,4 and 5 to terminals
10,9,8,7 and 6 (conventional flow) |
|
Description:
Models CLN-50 and CLN-100 are closed loop Hall
effect current sensors that accurately measure dc and ac current and provide electrical
isolation between the current carrying conductor and the output of the sensor. |
 
|
Specifications
| Electrical Specifications |
CLN-50 |
|
CLN-100 |
|
| Nominal current (IN) |
50 A rms |
|
100 A rms |
|
| Measuring range * |
0 to ± 90A |
|
0 to ± 150A |
|
| Sense resistor |
R. min. |
R. max. |
R. min. |
R. max. |
| with ±
12 V at 70 A peak |
50 ohms |
90 ohms |
n/a |
n/a |
|
at 100 A peak |
n/a |
n/a |
30 ohms |
55 ohms |
|
at 150 A peak |
n/a |
n/a |
30 ohms |
40 ohms |
| with ±
15 V at 90 A peak |
70 ohms |
100 ohms |
n/a |
n/a |
|
at 100 A peak |
n/a |
n/a |
30 ohms |
85 ohms |
|
at 150 A peak |
n/a |
n/a |
30 ohms |
40 ohms |
| Nominal analog output current |
50mA |
|
100mA |
|
| Turns ratio |
1:1000 |
|
1:1000 |
|
| Overall accuracy at 25 °C and
±12 V |
± 0.9% of I N |
|
± 0.9% of I N |
|
| Overall accuracy at 25 °C and ±
15 V |
± 0.5% of IN |
|
± 0.5% of IN |
|
| Supply voltage (Vdc) |
± 12 to ± 15 (± 5%) |
|
± 12 to ± 15 (± 5%) |
|
| Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.) |
3kV rms/50 Hz/1 min. |
|
3kV rms/50 Hz/1 min. |
|
| Accuracy-Dynamic Performance |
CLN-50 |
|
CLN-100 |
|
| Zero current offset at 25 °C (±
15V) |
± 0.2 mA max. |
|
± 0.2 mA max. |
|
| Offset current temperature drift |
|
|
|
|
| between 0
°C and +75 °C |
± 0.3 mA typ. |
± 0.6 mA max. |
± 0.3 mA typ. |
± 0.6 mA max. |
| between
-25 °C and +85 °C |
± 0.3 mA typ. |
± 0.8 mA max. |
± 0.3 mA typ. |
± 0.8 mA max. |
| Linearity |
better than ±0.1% |
|
better than ±0.1% |
|
| Response time |
less than 500 µs |
|
less than 500 µs |
|
| di/dt accurately followed |
better than 100 A/µs |
|
better than 100 A/µs |
|
| Bandwidth |
0 to 150 kHz (- 1 dB) |
|
0 to 150 kHz (- 1 dB) |
|
| General Information |
CLN-50 |
|
CLN-100 |
|
| Operating temperature |
-40 °C to +85 °C |
|
-40 °C to +85 °C |
|
| Storage temperature |
-40 °C to +90 °C |
|
-40 °C to +90 °C |
|
| Current drain (plus output
current) |
10 mA (at ± 15 V) |
|
14 mA (at ± 15 V) |
|
| Coil resistance |
110 ohms (at 70 °C) |
|
|
|
| at + 70oC |
30 ohms |
|
30 ohms |
|
| at + 85oC |
35 ohms |
|
|
|
| Package |
Flame retarded plastic case |
|
Flame retarded plastic case |
|
| Weight |
18 grams |
|
21 grams |
|
| Mounting: |
Designed to mount on PCB via thru hole
connection pins |
|
Designed to mount on PCB via thru hole
connection pins |
|
| Output reference |
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow) |
|
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow) |
|
| Aperture |
0.530" x 0.390" (13.5 mm x 10 mm) |
|
0.530" x 0.390" (13.5 mm x 10 mm) |
|
|
Description:
Models CLN-50SP1 and 100 SP1 are closed loop
Hall effect current sensors that accurately measure dc and ac currents and provide
electrical isolation between the current carrying conductor and the output of the sensor. |

|
SPECIFICATIONS
| Electrical Specifications |
CLN-50SP1 |
|
CLN-100SP1 |
|
| Nominal current (IN) |
50 A rms |
|
100 A rms |
|
| Measuring range * |
0 to ± 90A |
|
0 to ± 150A |
|
| Sense resistor |
R. min. |
R. max. |
R. min. |
R. max. |
| with ±
12 V at 70 A peak |
50 ohms |
90 ohms |
n/a |
n/a |
|
at 100 A peak |
n/a |
n/a |
30 ohms |
55 ohms |
|
at 150 A peak |
n/a |
n/a |
30 ohms |
40 ohms |
| with ±
15 V at 90 A peak |
70 ohms |
100 ohms |
n/a |
n/a |
|
at 100 A peak |
n/a |
n/a |
30 ohms |
85 ohms |
|
at 150 A peak |
n/a |
n/a |
30 ohms |
40 ohms |
| Nominal analog output current |
50mA |
|
100mA |
|
| Turns ratio |
1:1000 |
|
1:1000 |
|
| Overall accuracy at 25 °C and
±12 V |
± 0.9% of I N |
|
± 0.9% of I N |
|
| Overall accuracy at 25 °C and ±
15 V |
± 0.5% of IN |
|
± 0.5% of IN |
|
| Supply voltage (Vdc) |
± 12 to ± 15 (± 5%) |
|
± 12 to ± 15 (± 5%) |
|
| Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.) |
3kV rms/50 Hz/1 min. |
|
3kV rms/50 Hz/1 min. |
|
| Accuracy-Dynamic Performance |
CLN-50SP1 |
|
CLN-100SP1 |
|
| Zero current offset at 25 °C (±
15V) |
± 0.2 mA max. |
|
± 0.2 mA max. |
|
| Offset current temperature drift |
|
|
|
|
| between 0
°C and +75 °C |
± 0.3 mA typ. |
± 0.6 mA max. |
± 0.3 mA typ. |
± 0.6 mA max. |
| between
-25 °C and +85 °C |
± 0.3 mA typ. |
± 0.8 mA max. |
± 0.3 mA typ. |
± 0.8 mA max. |
| Linearity |
better than ±0.1% |
|
better than ±0.1% |
|
| Response time |
less than 500 µs |
|
less than 500 µs |
|
| di/dt accurately followed |
better than 100 A/µs |
|
better than 100 A/µs |
|
| Bandwidth |
0 to 150 kHz (- 1 dB) |
|
0 to 150 kHz (- 1 dB) |
|
| General Information |
CLN-50SP1 |
|
CLN-100SP1 |
|
| Operating temperature |
-40 °C to +85 °C |
|
-40 °C to +85 °C |
|
| Storage temperature |
-40 °C to +90 °C |
|
-40 °C to +90 °C |
|
| Current drain (plus output
current) |
10 mA (at ± 15 V) |
|
14 mA (at ± 15 V) |
|
| Coil resistance |
30 ohms (at 70 °C) |
|
30 ohms (at 70 °C) |
|
| Package |
Flame retarded plastic case |
|
Flame retarded plastic case |
|
| Weight |
26 grams |
|
27 grams |
|
| Mounting: |
Designed to mount on PCB via thru hole
connection pins |
|
Designed to mount on PCB via thru hole
connection pins |
|
| Output reference |
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow) |
|
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow) |
|
|
Description:
Models CLN-300 and CLN-500 are closed loop
Hall effect current sensors that accurately measure dc and ac currents and provide
electrical isolation between the current carrying conductor and the output of the sensor. |
 
|
| SPECIFICATIONS |
| Electrical Specifications |
CLN-300 |
|
CLN-500 |
|
| Nominal current (IN) |
300 A rms |
|
500 A rms |
|
| Measuring range * |
0 to ± 600 A |
|
0 to ± 1200 A |
|
| Sense resistor |
R. min. |
R. max. |
R. min. |
R. max. |
| with ±
12 V at 300 A peak |
0 ohms |
30 ohms |
n/a |
n/a |
|
at 600 A peak |
0 ohms |
5 ohms |
n/a |
n/a |
| with ±
15 V at 300 A peak |
5 ohms |
50 ohms |
n/a |
n/a |
|
at 500 A peak |
n/a |
n/a |
0 ohms |
50 ohms |
|
at 600 A peak |
5 ohms |
15 ohms |
n/a |
n/a |
|
at 1000 A peak |
n/a |
n/a |
0 ohms |
5 ohms |
| with ±
18 V at 300 A peak |
20 ohms |
70 ohms |
n/a |
n/a |
|
at 600 A peak |
20 ohms |
25 ohms |
n/a |
n/a |
| with ±
24 V at 500 A peak |
n/a |
n/a |
10 ohms |
130 ohms |
|
at 1200 A peak |
n/a |
n/a |
10 ohms |
25 ohms |
| Nominal analog output current |
50mA |
|
100mA |
|
| Turns ratio |
1:2000 |
|
1:5000 |
|
| Overall accuracy at 25 °C and
±12 V |
± 0.9% of I N |
|
± 0.9% of I N |
|
| Overall accuracy at 25 °C and ±
15 V |
± 0.5% of IN |
|
± 0.5% of IN |
|
| Supply voltage (Vdc) |
± 12 to ± 18 (± 5%) |
|
± 12 to ± 24 (± 5%) |
|
| Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.) |
7.5 kV rms/50 Hz/1 min. |
|
6 kV rms/50 Hz/1 min. |
|
| Accuracy-Dynamic Performance |
CLN-300 |
|
CLN-500 |
|
| Zero current offset at 25 °C (±
15V) |
± 0.3 mA max. |
|
± 0.2 mA max. |
|
| Offset current temperature
drift between 0 °C and +75 °C |
± 0.3 mA typ. |
± 0.5 mA max. |
± 0.2 mA typ. |
± 0.3 mA max. |
| Linearity |
better than ±0.1% |
|
better than ±0.1% |
|
| Response time |
less than 500 µs |
|
less than 1 µs |
|
| di/dt accurately followed |
better than 50 A/µs |
|
better than 50 A/µs |
|
| Bandwidth |
0 to 150 kHz (- 1 dB) |
|
0 to 100 kHz (- 1 dB) |
|
| General Information |
CLN-300 |
|
CLN-500 |
|
| Operating temperature |
-40 °C to +85 °C |
|
-40 °C to +85 °C |
|
| Storage temperature |
-40 °C to +90 °C |
|
-40 °C to +90 °C |
|
| Current drain (plus output
current) |
14 mA (at ± 18 V) |
|
22 mA (at ± 24 V) |
|
| Coil resistance |
25 ohms (at 70 °C) |
|
50 ohms (at 70 °C) |
|
| Package |
Flame retarded plastic case |
|
Flame retarded plastic case |
|
| Weight |
180 grams |
|
340 grams |
|
| Mounting: |
Panel mount via 2 holes |
|
Panel mount via 4 slots |
|
| Output reference |
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow) |
|
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow) |
|
| Aperture |
0.900 inch dia (23 mm) |
|
1.02 inch dia (26 mm) |
|
|
Description:
The Model CLN-300SP1/500SP1 are closed loop
Hall effect current sensors that accurately measure dc and ac currents and provide
electrical isolation between the current carrying conductor and the output of the sensor. |
 
|
SPECIFICATIONS:
| Electrical Specifications |
CLN-300SP1 |
|
CLN-500SP1 |
|
| Nominal current (IN) |
300 A rms |
|
500 A rms |
|
| Measuring range * |
0 to ± 600 A |
|
0 to ± 1200 A |
|
| Sense resistor |
R. min. |
R. max. |
R. min. |
R. max. |
| with ±
12 V at 300 A peak |
0 ohms |
30 ohms |
n/a |
n/a |
|
at 600 A peak |
0 ohms |
5 ohms |
n/a |
n/a |
| with ±
15 V at 300 A peak |
5 ohms |
50 ohms |
n/a |
n/a |
|
at 500 A peak |
n/a |
n/a |
0 ohms |
50 ohms |
|
at 600 A peak |
5 ohms |
15 ohms |
n/a |
n/a |
|
at 1000 A peak |
n/a |
n/a |
0 ohms |
5 ohms |
| with ±
18 V at 300 A peak |
20 ohms |
70 ohms |
n/a |
n/a |
|
at 600 A peak |
20 ohms |
25 ohms |
n/a |
n/a |
| with ±
24 V at 500 A peak |
n/a |
n/a |
10 ohms |
130 ohms |
|
at 1200 A peak |
n/a |
n/a |
10 ohms |
25 ohms |
| Nominal analog output current |
50mA |
|
100mA |
|
| Turns ratio |
1:2000 |
|
1:5000 |
|
| Overall accuracy at 25 °C and
±12 V |
± 0.9% of I N |
|
± 0.9% of I N |
|
| Overall accuracy at 25 °C and ±
15 V |
± 0.5% of IN |
|
± 0.5% of IN |
|
| Supply voltage (Vdc) |
± 12 to ± 18 (± 5%) |
|
± 12 to ± 24 (± 5%) |
|
| Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.) |
7.5 kV rms/50 Hz/1 min. |
|
6 kV rms/50 Hz/1 min. |
|
| Accuracy-Dynamic Performance |
CLN-300SP1 |
|
CLN-500SP1 |
|
| Zero current offset at 25 °C (±
15V) |
± 0.3 mA max. |
|
± 0.2 mA max. |
|
| Offset current temperature
drift between 0 °C and +75 °C |
± 0.3 mA typ. |
± 0.5 mA max. |
± 0.2 mA typ. |
± 0.3 mA max. |
| Linearity |
better than ±0.1% |
|
better than ±0.1% |
|
| Response time |
less than 500 µs |
|
less than 1 µs |
|
| di/dt accurately followed |
better than 50 A/µs |
|
better than 50 A/µs |
|
| Bandwidth |
0 to 150 kHz (- 1 dB) |
|
0 to 100 kHz (- 1 dB) |
|
| General Information |
CLN-300SP1 |
|
CLN-500SP1 |
|
| Operating temperature |
-40 °C to +85 °C |
|
-40 °C to +85 °C |
|
| Storage temperature |
-40 °C to +90 °C |
|
-40 °C to +90 °C |
|
| Current drain (plus output
current) |
14 mA (at ± 18 V) |
|
22 mA (at ± 24 V) |
|
| Coil resistance |
25 ohms (at 70 °C) |
|
50 ohms (at 70 °C) |
|
| Package |
Flame retarded plastic case |
|
Flame retarded plastic case |
|
| Weight |
730 grams |
|
885 grams |
|
| Mounting: |
Panel mount via 2 holes |
|
Panel mount via 4 slots |
|
| Output connection |
3 Faston terminals 0.248" x 0.031"
(6.32 mm x 0.80 mm) |
|
3 Faston terminals 0.248" x 0.031"
(6.32 mm x 0.80 mm) |
|
| Output reference |
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow) |
|
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow) |
|
|