Description Advanced
patent pending design accurately measures DC and AC currents
from 0-2000mA
Price - $995.00
CE Model Available
Description
Advanced patent pending design accurately measures DC and
AC currents from 0 to 2000 mA. Simply clamp the retractable probe on the conductor being
measured without breaking the circuit. Easy-to-read 31/2 digit LCD. An analog output is
provided for connection to an oscilloscope. Comes complete with batteries, optional
battery eliminator, hard carrying case and instructions.
SPECIFICATIONS:
Features
Measures low level DC & AC currents from 0 to 2000 mA
with resolution as low as 0.1mA
Basic DC accuracy of 1% of reading
True RMS measurement
Frequency range DC to 250 kHz
Built in 31/2 digit display
BNC analog output for connection to oscilloscope or recorder
Simple clamp-on operation
Supplied with optional AC power adapter and hard carrying
case
The Current Gun Series of hand-held,
noncontact Meter and Probes has been Discontinued. We suggest you go to
the following page for possible
replacements
Specifications
Model CG-100D
*3-1/2 digit LCD with 5 second readout hold
dc/ac Current Range: ±200 A FS
Basic Accuracy: ± 0.75% F.S. to 100A, ± 3% of
reading, 100A to 200A
Analog Output: ±2.0V/200A, ±1.0% of reading (plus above
stated accuracy)
Frequency Response: dc to 1 kHz (readout ac mode 20 Hz to 1
kHz)
Model CG-120A
dc/ac Current Ranges: ±50A FS, ±500A FS
Basic Accuracy: ±5% of reading
Overange Capability: 50 A Range-300% (150A) Accuracy stated
above plus ±1% of reading, 500 A range-None
Y8100 has been Discontinued.
We suggest you go to the following page for possible
replacements
Description
The F.W. Bell Y8100 is an exact replacement
for the Fluke Model Y8100 clamp-on current probe. It can be used with a digital
multimeter or oscilloscope to measure dc, ac or composite (ac/dc) currents. The
ergonomic pistol shape sets the standard for hand-held comfort. Two ranges, 20 A and 200
A, produce a 2 V output at full current range. An indicator light turns on when the
battery voltage is too low for proper operation.
SPECIFICATIONS:
Ranges
Low
20 A ac or dc
High
200 A ac or dc
Full Scale Output
2V
Basic Accuracy
DC to 65
Hz
<100 A: +2% of
range
>100 A: +3%
of range
65 Hz to
100 Hz
<100 A: add +3% of reading
>100 A: add +6% of range
Calibration cycle
1 year
Frequency response
dc to 1 kHz
Recommended load
> 1 mW, 100 pF
Temparature range
+15oC to +35oC for
specified accuracy
-10oC to +50oC
for storage & operation at reduced accuracy
The Model CLN-25 is a closed loop Hall effect
current sensor that accurately measures dc and ac currents and provides electrical
isolation between the current carrying conductor and the output of the sensor.
Electrical Specifications
Nominal current (IN)
25 Ampere turns rms
Measuring range *
0 to 36 Ampere turns (A.t.)
Sense resistor
R. min.
R. max.
with ±
12 V at 25 A.t. peak
100 ohms
200 ohms
at 36 A.t. peak
100 ohms
140 ohms
with ±
15 V at 25 A.t. peak
100 ohms
320 ohms
at 36 A.t. peak
100 ohms
190 ohms
Nominal analog output current
25 mA
Turns ratio
1-2-3-4-5:1000
Overall accuracy at 25 °C and
±12 V
± 0.7% of IN
Overall accuracy at 25 °C and ±
15 V
± 0.5% of IN
Supply voltage (Vdc)
± 12 to ± 15 (± 5%)
Dielectric strength
between the current carrying conductor and the
output of the sensor: 5 kV rms/50 Hz/1 min.
Accuracy-Dynamic Performance
Typical
Max.
Zero current offset at 25 °C (±
15V)
± 0.05 mA
± 0.15 mA
Residual current offset after an
overload of 3 x IN
± 0.05 mA
± 0.15 mA
Offset current temperature drift
(± 15V)
(between
0 °C and +25 °C)
± 0.06 mA
± 0.25 mA
(between +25 °C and +70 °C)
± 0.1 mA
± 0.35 mA
Linearity
better than ±0.2%
Response time
less than 1 µs
di/dt accurately followed
better than 50 A/µs
Bandwidth
0 to 150 kHz (- 1 dB)
General Information
Operating temperature
-40 °C to +85 °C
Storage temperature
-40 °C to +90 °C
Current drain 10
mA (at ± 15 V) plus output current
Coil resistance
110 ohms (at 70 °C)
Package
Flame retarded plastic case
Weight
16 grams
Mounting:
Designed to mount directly on PCB via through
hole connection pins
Output reference
better than 50 A/µs
Bandwidth
To obtain a positive output on the terminal
marked "O/P", current must flow from terminals 1,2,3,4 and 5 to terminals
10,9,8,7 and 6 (conventional flow)
Models CLN-50 and CLN-100 are closed loop Hall
effect current sensors that accurately measure dc and ac current and provide electrical
isolation between the current carrying conductor and the output of the sensor.
Specifications
Electrical Specifications
CLN-50
CLN-100
Nominal current (IN)
50 A rms
100 A rms
Measuring range *
0 to ± 90A
0 to ± 150A
Sense resistor
R. min.
R. max.
R. min.
R. max.
with ±
12 V at 70 A peak
50 ohms
90 ohms
n/a
n/a
at 100 A peak
n/a
n/a
30 ohms
55 ohms
at 150 A peak
n/a
n/a
30 ohms
40 ohms
with ±
15 V at 90 A peak
70 ohms
100 ohms
n/a
n/a
at 100 A peak
n/a
n/a
30 ohms
85 ohms
at 150 A peak
n/a
n/a
30 ohms
40 ohms
Nominal analog output current
50mA
100mA
Turns ratio
1:1000
1:1000
Overall accuracy at 25 °C and
±12 V
± 0.9% of I N
± 0.9% of I N
Overall accuracy at 25 °C and ±
15 V
± 0.5% of IN
± 0.5% of IN
Supply voltage (Vdc)
± 12 to ± 15 (± 5%)
± 12 to ± 15 (± 5%)
Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.)
3kV rms/50 Hz/1 min.
3kV rms/50 Hz/1 min.
Accuracy-Dynamic Performance
CLN-50
CLN-100
Zero current offset at 25 °C (±
15V)
± 0.2 mA max.
± 0.2 mA max.
Offset current temperature drift
between 0
°C and +75 °C
± 0.3 mA typ.
± 0.6 mA max.
± 0.3 mA typ.
± 0.6 mA max.
between
-25 °C and +85 °C
± 0.3 mA typ.
± 0.8 mA max.
± 0.3 mA typ.
± 0.8 mA max.
Linearity
better than ±0.1%
better than ±0.1%
Response time
less than 500 µs
less than 500 µs
di/dt accurately followed
better than 100 A/µs
better than 100 A/µs
Bandwidth
0 to 150 kHz (- 1 dB)
0 to 150 kHz (- 1 dB)
General Information
CLN-50
CLN-100
Operating temperature
-40 °C to +85 °C
-40 °C to +85 °C
Storage temperature
-40 °C to +90 °C
-40 °C to +90 °C
Current drain (plus output
current)
10 mA (at ± 15 V)
14 mA (at ± 15 V)
Coil resistance
110 ohms (at 70 °C)
at + 70oC
30 ohms
30 ohms
at + 85oC
35 ohms
Package
Flame retarded plastic case
Flame retarded plastic case
Weight
18 grams
21 grams
Mounting:
Designed to mount on PCB via thru hole
connection pins
Designed to mount on PCB via thru hole
connection pins
Output reference
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow)
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow)
Models CLN-50SP1 and 100 SP1 are closed loop
Hall effect current sensors that accurately measure dc and ac currents and provide
electrical isolation between the current carrying conductor and the output of the sensor.
SPECIFICATIONS
Electrical Specifications
CLN-50SP1
CLN-100SP1
Nominal current (IN)
50 A rms
100 A rms
Measuring range *
0 to ± 90A
0 to ± 150A
Sense resistor
R. min.
R. max.
R. min.
R. max.
with ±
12 V at 70 A peak
50 ohms
90 ohms
n/a
n/a
at 100 A peak
n/a
n/a
30 ohms
55 ohms
at 150 A peak
n/a
n/a
30 ohms
40 ohms
with ±
15 V at 90 A peak
70 ohms
100 ohms
n/a
n/a
at 100 A peak
n/a
n/a
30 ohms
85 ohms
at 150 A peak
n/a
n/a
30 ohms
40 ohms
Nominal analog output current
50mA
100mA
Turns ratio
1:1000
1:1000
Overall accuracy at 25 °C and
±12 V
± 0.9% of I N
± 0.9% of I N
Overall accuracy at 25 °C and ±
15 V
± 0.5% of IN
± 0.5% of IN
Supply voltage (Vdc)
± 12 to ± 15 (± 5%)
± 12 to ± 15 (± 5%)
Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.)
3kV rms/50 Hz/1 min.
3kV rms/50 Hz/1 min.
Accuracy-Dynamic Performance
CLN-50SP1
CLN-100SP1
Zero current offset at 25 °C (±
15V)
± 0.2 mA max.
± 0.2 mA max.
Offset current temperature drift
between 0
°C and +75 °C
± 0.3 mA typ.
± 0.6 mA max.
± 0.3 mA typ.
± 0.6 mA max.
between
-25 °C and +85 °C
± 0.3 mA typ.
± 0.8 mA max.
± 0.3 mA typ.
± 0.8 mA max.
Linearity
better than ±0.1%
better than ±0.1%
Response time
less than 500 µs
less than 500 µs
di/dt accurately followed
better than 100 A/µs
better than 100 A/µs
Bandwidth
0 to 150 kHz (- 1 dB)
0 to 150 kHz (- 1 dB)
General Information
CLN-50SP1
CLN-100SP1
Operating temperature
-40 °C to +85 °C
-40 °C to +85 °C
Storage temperature
-40 °C to +90 °C
-40 °C to +90 °C
Current drain (plus output
current)
10 mA (at ± 15 V)
14 mA (at ± 15 V)
Coil resistance
30 ohms (at 70 °C)
30 ohms (at 70 °C)
Package
Flame retarded plastic case
Flame retarded plastic case
Weight
26 grams
27 grams
Mounting:
Designed to mount on PCB via thru hole
connection pins
Designed to mount on PCB via thru hole
connection pins
Output reference
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow)
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow)
Models CLN-300 and CLN-500 are closed loop
Hall effect current sensors that accurately measure dc and ac currents and provide
electrical isolation between the current carrying conductor and the output of the sensor.
SPECIFICATIONS
Electrical Specifications
CLN-300
CLN-500
Nominal current (IN)
300 A rms
500 A rms
Measuring range *
0 to ± 600 A
0 to ± 1200 A
Sense resistor
R. min.
R. max.
R. min.
R. max.
with ±
12 V at 300 A peak
0 ohms
30 ohms
n/a
n/a
at 600 A peak
0 ohms
5 ohms
n/a
n/a
with ±
15 V at 300 A peak
5 ohms
50 ohms
n/a
n/a
at 500 A peak
n/a
n/a
0 ohms
50 ohms
at 600 A peak
5 ohms
15 ohms
n/a
n/a
at 1000 A peak
n/a
n/a
0 ohms
5 ohms
with ±
18 V at 300 A peak
20 ohms
70 ohms
n/a
n/a
at 600 A peak
20 ohms
25 ohms
n/a
n/a
with ±
24 V at 500 A peak
n/a
n/a
10 ohms
130 ohms
at 1200 A peak
n/a
n/a
10 ohms
25 ohms
Nominal analog output current
50mA
100mA
Turns ratio
1:2000
1:5000
Overall accuracy at 25 °C and
±12 V
± 0.9% of I N
± 0.9% of I N
Overall accuracy at 25 °C and ±
15 V
± 0.5% of IN
± 0.5% of IN
Supply voltage (Vdc)
± 12 to ± 18 (± 5%)
± 12 to ± 24 (± 5%)
Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.)
7.5 kV rms/50 Hz/1 min.
6 kV rms/50 Hz/1 min.
Accuracy-Dynamic Performance
CLN-300
CLN-500
Zero current offset at 25 °C (±
15V)
± 0.3 mA max.
± 0.2 mA max.
Offset current temperature
drift between 0 °C and +75 °C
± 0.3 mA typ.
± 0.5 mA max.
± 0.2 mA typ.
± 0.3 mA max.
Linearity
better than ±0.1%
better than ±0.1%
Response time
less than 500 µs
less than 1 µs
di/dt accurately followed
better than 50 A/µs
better than 50 A/µs
Bandwidth
0 to 150 kHz (- 1 dB)
0 to 100 kHz (- 1 dB)
General Information
CLN-300
CLN-500
Operating temperature
-40 °C to +85 °C
-40 °C to +85 °C
Storage temperature
-40 °C to +90 °C
-40 °C to +90 °C
Current drain (plus output
current)
14 mA (at ± 18 V)
22 mA (at ± 24 V)
Coil resistance
25 ohms (at 70 °C)
50 ohms (at 70 °C)
Package
Flame retarded plastic case
Flame retarded plastic case
Weight
180 grams
340 grams
Mounting:
Panel mount via 2 holes
Panel mount via 4 slots
Output reference
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow)
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow)
The Model CLN-300SP1/500SP1 are closed loop
Hall effect current sensors that accurately measure dc and ac currents and provide
electrical isolation between the current carrying conductor and the output of the sensor.
SPECIFICATIONS:
Electrical Specifications
CLN-300SP1
CLN-500SP1
Nominal current (IN)
300 A rms
500 A rms
Measuring range *
0 to ± 600 A
0 to ± 1200 A
Sense resistor
R. min.
R. max.
R. min.
R. max.
with ±
12 V at 300 A peak
0 ohms
30 ohms
n/a
n/a
at 600 A peak
0 ohms
5 ohms
n/a
n/a
with ±
15 V at 300 A peak
5 ohms
50 ohms
n/a
n/a
at 500 A peak
n/a
n/a
0 ohms
50 ohms
at 600 A peak
5 ohms
15 ohms
n/a
n/a
at 1000 A peak
n/a
n/a
0 ohms
5 ohms
with ±
18 V at 300 A peak
20 ohms
70 ohms
n/a
n/a
at 600 A peak
20 ohms
25 ohms
n/a
n/a
with ±
24 V at 500 A peak
n/a
n/a
10 ohms
130 ohms
at 1200 A peak
n/a
n/a
10 ohms
25 ohms
Nominal analog output current
50mA
100mA
Turns ratio
1:2000
1:5000
Overall accuracy at 25 °C and
±12 V
± 0.9% of I N
± 0.9% of I N
Overall accuracy at 25 °C and ±
15 V
± 0.5% of IN
± 0.5% of IN
Supply voltage (Vdc)
± 12 to ± 18 (± 5%)
± 12 to ± 24 (± 5%)
Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.)
7.5 kV rms/50 Hz/1 min.
6 kV rms/50 Hz/1 min.
Accuracy-Dynamic Performance
CLN-300SP1
CLN-500SP1
Zero current offset at 25 °C (±
15V)
± 0.3 mA max.
± 0.2 mA max.
Offset current temperature
drift between 0 °C and +75 °C
± 0.3 mA typ.
± 0.5 mA max.
± 0.2 mA typ.
± 0.3 mA max.
Linearity
better than ±0.1%
better than ±0.1%
Response time
less than 500 µs
less than 1 µs
di/dt accurately followed
better than 50 A/µs
better than 50 A/µs
Bandwidth
0 to 150 kHz (- 1 dB)
0 to 100 kHz (- 1 dB)
General Information
CLN-300SP1
CLN-500SP1
Operating temperature
-40 °C to +85 °C
-40 °C to +85 °C
Storage temperature
-40 °C to +90 °C
-40 °C to +90 °C
Current drain (plus output
current)
14 mA (at ± 18 V)
22 mA (at ± 24 V)
Coil resistance
25 ohms (at 70 °C)
50 ohms (at 70 °C)
Package
Flame retarded plastic case
Flame retarded plastic case
Weight
730 grams
885 grams
Mounting:
Panel mount via 2 holes
Panel mount via 4 slots
Output connection
3 Faston terminals 0.248" x 0.031"
(6.32 mm x 0.80 mm)
3 Faston terminals 0.248" x 0.031"
(6.32 mm x 0.80 mm)
Output reference
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow)
To obtain a positive output on the terminal
marked "O/P", aperture current must flow in the direction of the arrow
(conventional flow)
Models CLO-300 and CLO-500 are closed loop
Hall effect sensors that accurately measure dc and ac currents and provide
electrical isolation between the current carrying conductor and the output of the sensor.
SPECIFICATIONS
Electrical Specifications
CLO-300
CLO-500
Nominal current (IN)
300 A rms
500 A rms
Measuring range *
0 to ± 600A
0 to ± 1200 A
Sense resistor
R. min.
R. max.
R. min.
R. max.
with ±
12 V at 300 A peak
0 ohms
30 ohms
n/a
n/a
at 600 A peak
0 ohms
5 ohms
n/a
n/a
with ±
15 V at 300 A peak
20 ohms
50 ohms
n/a
n/a
at 500 A peak
n/a
n/a
0 ohms
50 ohms
at 600 A peak
5 ohms
10 ohms
n/a
n/a
at 1200 A peak
n/a
n/a
0 ohms
5 ohms
with ±
18 V at 300 A peak
20 ohms
70 ohms
n/a
n/a
at 600 A peak
20 ohms
25 ohms
n/a
n/a
Nominal analog output current
150mA
100mA
Turns ratio
1:2000
1:5000
Overall accuracy at 25 °C and ±
15 V
± 0.5% of IN
± 0.3% of IN
Supply voltage (Vdc)
± 12 to ± 18 (± 5%)
± 15 (± 5%)
Dielectric strength (between the
current carrying conductor and the output of the sensor: 5 kV rms/50 Hz/1 min.)
6kV rms/50 Hz/1 min.
3kV rms/50 Hz/1 min.
Accuracy-Dynamic Performance
CLO-300
CL0-500
Zero current offset at 25 °C
± 0.3 mA max.
± 0.2 mA max.
Offset current temperature drift
between 0
°C and +70 °C
± 0.3 mA typ.
± 0.5 mA max.
± 0.2 mA typ.
± 0.3 mA max.
between
-25 °C and +85 °C
± 0.3 mA typ.
± 0.8 mA max.
± 0.3 mA typ.
± 0.8 mA max.
Linearity
better than ±0.1%
better than ±0.1%
Response time
less than 1 µs
less than 1 µs
di/dt accurately followed
better than 50 A/µs
better than 50 A/µs
Bandwidth
0 to 150 kHz (- 1 dB)
0 to 150 kHz (- 1 dB)
General Information
CL0-300
CL0-500
Operating temperature
-40 °C to +85 °C
-40 °C to +85 °C
Storage temperature
-40 °C to +90 °C
-40 °C to +90 °C
Current drain (plus output
current)
14 mA (at ± 15 V)
20 mA (at ± 15 V)
Coil resistance
25 ohms (at 70 °C)
50 ohms (at 70 °C)
Package
Flame retarded plastic coil
Flame retarded plastic coil
Weight
120 grams
265 grams
Mounting:
Four mounting holes 0.169 inch (4.3 mm)
diameter
Four mounting holes 0.169 inch (4.3 mm)
diameter
Output reference
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow)
To obtain a positive output on the terminal
marked "O/P", aperature current must flow in the direction of the arrow
(conventional flow)