Hanna Hygrometers


HI 93640 Compact, Portable Thermo-Hygrometer

  • Portability and Simplicity HI 93640 is palm-sized and portable. One button for ON/OFF and 1 button for each range assures simple operation for even non-technical personnel.
  • Low Battery Indicator The LCD will indicate that the battery is low on power. This prevents the user from taking erroneous readings due to low battery power.
  • Liquid Crystal Display HI 93640 has a large, easy-to-read LCD that can be read from any angle.
  • Dual Temperature Range The temperature range is switchable from °F to °C at the touch of a button.


HI 93640 is a compact, one-hand portable, versatile hygrometer with a convenient wrist-strap so that you can monitor relative humidity anywhere. The built-in thin-film capacitance sensor assures accurate humidity measurements from 0.0 to 100.0% RH with a resolution of 0.1%. The rubber keypad protects the keyboard from dust or accidental splashes. A sintered cap can be placed on the sensor shaft for protection in dusty environments. If fast response is desired, the cap can be removed. Designed for one-hand operation, the compact housing fits easily into the palm of the hand. This simple-to-use meter is ideal for the HVAC field. HI 93640 comes complete with a built-in RH sensor and a sintered cap.

Specifications:

  Range: R.H.            0.0 to 100.0% RH

         °C              0.0 to 60.0°C

         °F              32 to 140 °F

  Resolution:            0.1% RH / 0.1°C / 1°F

  Accuracy:              ±2% RH (10% to 95%) / ±0.4°C / ±1°F

  Environment:           32 to 122°F (0 to 50°C)

  Battery:               9 volt  / with low battery indicator

  Battery Life:          100 hours of  continuous use

  Weight:                11.3 oz. (320 g)

  Dimensions:            7.5 x 3.1 x 1.5" (190 x 80 x 38mm)

  Maintenance Contract:  Annual service contract available


HI 8564 Portable Thermo-Hygrometer with Detachable Probe

  • Quick Response Time With no air circulation, the response time for this meter is under 30 seconds for 95% accurate Relative Humidity and under 15 seconds for 95% accurate temperature.
  • Long Cable for Maximum Flexibility This meter can be carried anywhere in the museum, library, archives or any place where relative humidity is important. The standard 7 foot (2 m) probe allows remote monitoring, for more remote applications, a 16½ foot (5 m) cable is available.
  • Two Meters in One Unit The rugged RH probe has a temperature sensor built-in, this makes HI 8564 an excellent stand-alone thermometer.


HI 8564 thermo-hygrometer provides readings with 95% precision in a very short time both for R.H. and for temperature. The detachable R.H. probe is housed in a rugged ABS cylinder with a thin-film polymer humidity sensor and a signal amplifier. A perforated cap on the probe allows the air to circulate while it protects the sensitive sensor. The standard cable is 7 feet long (2 m), and a 16½ foot (5 m) version is also available. Specially designed for internal applications such as museums, libraries, computer rooms and printing facilities. The smooth membrane keyboard has 4 keys that make operation simple and quick. A large LCD displays readings in easy-to-read digits, each with a symbol next to it to identify the operating mode.

Specifications:

  Range: RH              10.0 to 95.0% RH

         Temperature     32 to 140°F (0.0 to 60.0°C)

  Resolution:            0.1% RH; 1°F (0.1°C)

  Accuracy:              2% RH; 1°F (0.4°C)

  Probe:                 HI 70601/2 thin film polymer sensor 

                         Relative Humidity Probe

  Environment:           32 to 122°F (0 to 50°C)

  Battery:               9 volt battery

  Battery Life:          100 hours of  continuous use

  Weight:                11.1 oz. (315g)

  Dimensions:            7.3 x 3.2 x 1.8" (185 x 82 x 45mm)


HI 9064 & HI 9065 Water-resistant Hygrometers

  • Watertight and Dust proof Casing HI 9064 is supplied complete with a rugged carrying case which is water and dust proof, particularly useful for outdoor applications.
  • Relative Humidity Probe with Perforated Cap The RH probe has a thin-film polymer Humidity sensor protected behind a perforated, protective cap.
  • HOLD Key Freezes Current Reading Simply press the "HOLD" key, and the reading is frozen until you have recorded it.


HI 9064 and HI 9065 are heavy-duty hygrometers specially designed for field applications such as HVAC. They are housed in a rugged water-resistant case to provide maximum protection in the field. The Relative Humidity probe houses a thin-film polymer sensor which performs all R.H. readings to 95% accuracy very quickly. A "HOLD" key will instantly freeze the reading on the LCD. HI 9065 can also measure temperature with the R.H. probe's internal sensor from 32 to 140°F (0 to 60°C). A wide selection of R.H. probes is available for special applications. HI 9064 is supplied complete with a rugged carrying case and an HI 70608/2 RH probe with a 7' (2m) cable. HI 9065 is supplied with a rugged carrying case and an HI 70605/2 RH probe with a built-in temperature sensor and 7' (2 m) cable.

Specifications:

                            HI 9064                    HI 9065            

  Range:      R.H.       5.0 to 95.0%                5.0 to 95.0%

              °C             ----                   0.0 to 60.0°C

              °F             ----                    32 to 140°F

  Resolution: R.H.           0.1%                       0.1%

              °C             ----                       0.1°C

              °F             ----                        1°F

  Accuracy:   R.H.           ±2%                         ±2%

              °C             ----                      ±0.4°C

              °F             ----                       ±1°F

  Probe:                  HI 70608/2                 HI 70605/2

  Environment:                   32 to 122°F (0 to 50°C)

  Battery:            4 x 1.4 volt AAA / 200 hours of continuous use

  Weight:                   15 oz. (425g) KIT: 3.1 lbs (1.4 Kg)

  Dimensions:                7.7 x 3.1 x 2.4" (196 x 80 x 60mm)

  Service Contract:          Annual service contract available


HI 9161 Portable, Printing, Thermo-Hygrometer

  • Documented monitoring Ideal for constant monitoring of R.H. levels. It prints sample #, date and time of recording, printing interval, R.H. and ºC.
  • User Selectable Printing Intervals Choose from 1, 2, 5, 10, 15, 30, 60, 120 and 180 minute printing intervals.
  • Low Power Consumption Long battery life with up to 500 hours of use with 60 minute printing intervals. If used in the field, the meter can be plugged into a 12 VDC battery recharger for extended periods of printing.
  • No Need for Thermal Paper Type-belt printer uses regular, inexpensive, non-fading paper.


HI 9161 is the world's first portable, printing, thermo-hygrometer. This unique, lightweight meter gives instant print-outs of sample #, date and time of recording, printing interval, relative humidity and temperature at user-selectable intervals (R.H. & temp. print with 0.1 resolution). The intervals are selectable from 1, 2, 5, 10, 15, 30, 60, 120 and 180 minutes. The large LCD displays both the Relative Humidity reading and temperature reading simultaneously. When your laboratory recording requires high accuracy (2% RH and 0.4°C/1°F) and fast response, the HI 9161 is the meter of choice. It has been designed to read from two separate probes, an R.H. probe and a temperature probe for increased flexibility. An RH probe with a 5 meter cable (HI 70604/5) is also available for special applications. A wide selection of interchangeable HI 762 temperature probes is available. HI 9161 comes complete with an HI 70604/2 R.H. probe with 7' (2 m) cable, an HI 762L/2 temperature probe and a rugged carrying case.

Specifications:

                                HI 9161F                   HI 9161C           

  Range:      R.H.            5.0 to 95.0%               5.0 to 95.0%

              Temp          -20.0 to +60.0°C	       -4.0 to +140.0°F

  Resolution: R.H.                0.1%                       0.1%

              Temp                0.1°C	                     0.1°F

  Accuracy:   R.H.                 ±2%                        ±2%

              Temp               ±0.4°C	                     ±1°F

  Probe:                 HI 70604/2 TFPC R.H. probe; HI 762L/2 temp probe

  Printer:                 Low-power impact type belt, using plain paper

  Printing Intervals:   Selectable from 1,2,5,10,15,30,60,120 & 180 minutes

  Environment:                        32 to 122°F (0 to 50°C)

  Battery:              4 x 1.5 volt AA / 500 hours with 60 min. intervals

                                  Power socket for 12 VDC supply

  Weight:                       18oz (500g)  KIT: 3.1 lbs (1.4 Kg)

  Dimensions:                   8.7 x 3.2 x 2.6" (220 x 82 x 66mm)

  Service Contract:             Annual service contract available


HI 91610 Printing and Logging Thermo-Hygrometer

  • Logging Capacity Up to 16,000 readings can be stored in memory.
  • Documented monitoring Ideal for constant monitoring of R.H. levels. It prints sample #, date and time of recording, printing interval, R.H. and °F/ºC.
  • Computer Compatible Cordless Infrared Transmission to the HI 9200 RS232 receiver requires no extra cables.
  • No Need for Thermal Paper Printer uses readily available plain, non-fading paper (HI 92241/P).


HI 91610 combines the high accuracy and portability of the HI 9161 with an extensive printing and logging feature and an infrared, RS232, data transfer system. In addition to supplying the user with sample #, date and time, interval, R.H. and temperature at the touch of a button, it also provides datalogging facilities that store information for transfer to a PC or for retrieval and/or printing at a later date (R.H. and temp. print with 0.1 resolution). Sophisticated software allocates data (up to 16,000 readings) to maximize available space, regardless of what the logging interval is. The Relative Humidity probe houses a thin-film polymer sensor which performs all R.H. readings to 95% of final value accuracy very quickly. The probe is supplied with a 7 Foot (2 m) cable. An independent temperature probe provides highly accurate temperature readings. An R.H. probe with a 16½ Foot (5 m) cable (HI 70604/5) is also available for special applications. A wide selection of HI 762 temperature probes is available. HI 91610 is supplied complete with an HI 70604/2 RH probe with 7 Foot (2 m) cable, and HI 762L/2 temperature probe and a rugged carrying case. HI 9200 infrared transmitter is also available.

Specifications:

                              HI 91610F 	            HI 91610C

  Range         RH:        5.0 to 95.0% RH              5.0 to 95.0% RH

             °F/°C:       -4.0 to +140.0°F             -20.0 to +60.0°C	

  Resolution    RH:             0.1%                          0.1% 

             °F/°C:             0.1°F                         0.1°C

  Accuracy      RH:              ±2%                           ±2%

             °F/°C:             ±1°F                         ±0.4°C

  Probe:                            HI 70604/2 TFPC R.H. probe;

                                    HI 762L/2 temperature probe

  Printer:                 Low-power impact type-belt, 14 characters per 

                             line using 38mm plain paper (HI 92241/P)

  Printing Intervals:   Selectable from 1,2,5,10,15,30,60,120 & 180 minutes

  Environment Temp.:                 32 to 122°F (0 to 50°C)

  Battery:                                4 x 1.4 Volts

  Battery Life:                    150 hours of continuous use

  Weight:                       18oz (500g)  KIT:  3.1 lbs(1.4 Kg)

  Dimensions:                   8.7 x 3.2 x 2.6" (220 x 82 x 66mm)

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117