PROBES

 


CONDUCTIVITY PROBES

 

Hanna Instruments was the first instrumentation manufacturer to offer a 4-ring potentiometric probe with a conductivity meter. The potentiometric method of measuring electrical conductivity in liquids is by far the most accurate method available today. The four rings are aligned concentrically on the probe shaft. The two outer rings apply a voltage which creates a buffer field around the two inner rings. The inner rings pick up a current and measure the conductivity of the liquid inside the buffer field. This completely eliminates the polarization which occurs in the 2-ring amperometric method.

Without polarization, the probe can also measure a larger range of conductivity because it does not suffer from electrolysis. This 4-ring method is used in all of the following probes.

HI 3291 Detachable CONMET 1 ATC probe, length: 6.2" (158 mm).
HI 3292 Detachable CONMET 2 ATC probe, length: 6.2" (158 mm).
HI 3295 Detachable CONMET 3 ATC probe, length: 6.2" (158 mm).
HI 76301W Detachable 4-ring ATC conductivity probe for HI 8033, HI 8633 & HI 8734 with 3.3' (1 m) cable.
HI 76302W Detachable 4-ring ATC conductivity probe for HI 9033, HI 9034, HI 933300, HI 9130 with 3.3' (1 m) cable.
HI 76303 Detachable 4-ring platinum ATC conductivity probe for HI 933100 & HI 9635 with 3.3' (1 m) cable.
HI 7633W Detachable 4-ring ATC conductivity probe for HI 8733 with 3.3' (1 m) cable.
HI 7685 Detachable 4-ring platinum ATC conductivity probe for HI 8819 with 3.3' (1 m) cable.
HI 7686 Detachable 4-ring platinum ATC conductivity probe for HI 9032 with 3.3' (1 m) cable.
HI 7687 Detachable 4-ring platinum ATC conductivity probe for HI 8820 with 3.3' (1 m) cable.

 


DISSOLVED OXYGEN PROBE

The HI 76407 dissolved oxygen probe is specially shaped for BOD bottles making the meter and probe perfect for laboratory as well as field applications. Calibration is fast and simple and all DO measurements are temperature compensated. The pre-tensioned and ready-made Teflon© membrane can be changed in a few seconds without the need to stretch and cut the replacement. HI 76407 is offered with several cable lengths to meet your specific needs.

Item # Description
HI 76401 DO probe with 10 foot (3m) cable used with HI 8043.
HI 76407/4 DO probe with 13 foot (4m) cable used with, HI 9142, HI 9143, HI 9145, HI 9141, HI 91410.
HI 76407/10 DO probe with 33 foot (10m) cable used with, HI 9142, HI 9143, HI 9145, HI 9141 & HI 91410.
HI 76407/20 DO probe with 67 foot (20m) cable used with, HI 9142, HI 9143, HI 9145, HI 9141 & HI 91410.
HI 7041S Potassium Chloride electrolyte solution, 30 mL
HI 76407A/P Pack of 5 replacement membranes.

 


HI 766 K-TYPE THERMOCOUPLE PROBES

These Probes are all specially constructed for excellent contact with the surface being measured. The several different options below are designed to meet all of your surface temperature measurement needs. Due to the high surface temperatures involved, it is important that the probe handle does not reach a temperature above 302°F (150°C). If this happens, the probe may be damaged. Response times all refer to 63.2% of measuring range.

Part # Description Max Temp. Dimensions
HI 766 K-Type Thermocouple Probes with integral handle, 3.3' (1M) cable & mini-connector
HI 766A Roller surface probe 600°F (320°C) 11" x 4" (280mm x 100mm)
HI 766B Surface temp. probe 1200°F (650°C) 11" x 0.6" (280mm x 16mm)
HI 766C Penetration Probe 1650°F (900°C) 4.8" x 0.12" (120mm x 3mm)
HI 766D Air Temp. Probe 570°F (300°C) 9.6" x 0.12" (245mm x 3mm)
HI 766E1 General Purpose Probe 1650°F (900°C) 4.7" x 0.12" (120mm x 3mm)
HI 766E2 General Purpose Probe 1650°F (900°C) 8.5" x 0.2" (220mm x 5mm)
HI 766F High Temp. Probe 2000°F (1100°C) 10" x 0.06" (255mm x 1.5mm)
HI 766B1 90° Angle Surface Probe 840°F (450°C) 11.8" x 1.2" (300mm x 30mm)
HI 766B2 Surface Temp. Probe 1650°F (900°C) 5.1" x 0.3" (130mm x 8mm)
HI 766B3 Small Surface Temp. Probe 390°F (200°C) 5.1" x 0.2" (130mm x 5mm)
HI 766TV1 Pipe Clamp Temp. Probe 390°F (200°C) 1.4" (35mm) Opening
HI 766F1 Wire Temp. Probe 900°F (480°C) 3.3" x 0.08" (1m x 2mm)
HI 766 K-Type Thermocouple Probes With Detachable Handle
HI 766PA Roller surface probe 600°F (320°C) 11" x 4" (280mm x 100mm)
HI 766PB Surface temp. probe 1200°F (650°C) 7.9" x 0.6" (200mm x 16mm)
HI 766PC Penetration Probe 1650°F (900°C) 6.1" x 0.12" (155mm x 3mm)
HI 766PD Air Temp. Probe 570°F (300°C) 9.8" x 0.12" (250mm x 3mm)
HI 766PE1 General Purpose Probe 1650°F (900°C) 6.1" x 0.12" (155mm x 3mm)
HI 766PE2 General Purpose Probe 1650°F (900°C) 7.8" x 0.20" (200mm x 5mm)
HI 766HD Probe handle with 3.3' (1 m) cable fitted with a mini-connector for the detachable probes above.

 


RELATIVE HUMIDITY PROBES

Hanna Instruments Humidity probes are constructed of durable ABS & utilize a high-tech Thin-Film Polymer Capacitance humidity sensor. This sensor enables rapid response and high accuracy. Several different versions are available for your specific R.H. needs:

Code Description
HI 70601/2 Replacement RH/temp. probe for HI 8564, 7' (2m) cable with DIN Connector
HI 70601/5 Replacement RH/temp. probe for HI 8564, 16.5' (5m) cable with DIN Connector
HI 70604/2 Interchangeable RH/temp. probe for HI 1961, HI 91610 & HI 9261 with screw type connector and 7' (2m) cable.
HI 70604/5 Interchangeable RH/temp. probe for HI 1961, HI 91610 & HI 9261 with screw type connector and 16.5' (5m) cable.
HI 70605/2 Interchangeable RH/temp. probe for HI 9065 with screw type connector and 7' (2m) cable.
HI 70605/5 Interchangeable RH/temp. probe for HI 9065 with screw type connector and 16.5' (5m) cable.
HI 70606/2 Interchangeable RH/temp. probe for HI 9161 & HI 91610 with screw type connector, 7' (2m) cable and sintered cap.
HI 70606/5 Interchangeable RH/°C probe for HI 9161 & HI 91610 with screw type connector, 16.5' (5m) cable and sintered cap.
HI 70607/2 Interchangeable RH/°C probe for HI 9065 with screw type connector, 7' (2m) cable and sintered cap.
HI 70607/5 Interchangeable RH/°C probe for HI 9065 with screw type connector, 16.5' (5m) cable and sintered cap.
HI 70608/2 Interchangeable RH/°C probe for HI 9064 & HI 9160 with screw type connector & 7' (2m) cable.
HI 70608/5 Interchangeable RH/°C probe for HI 9064 & HI 9160 with screw type connector & 16.5' (5m) cable.

Temperature Probes for Hanna ATC pH meters

GENERAL SPECIFICATIONS FOR STANDARD PROBES:
Range: -58 to 302°F (-50 to 150°C)
Accuracy: ±0.9°F (±0.5°C)
Interchange error (MAX): 4°F (2°C)
Item # Description Sensor
HI 7669/2W General purpose probe for HI 8417, HI 8520, HI 8521, HI 9017, HI 9023, HI 9224, HI 9025, HI 9219, HI 9224, HI 92240, HI 9318, HI 9321, HI 31400, HI 931401, HI 9622, HI 9624, HI 9625, HI 96240, HI 96250, pH 300, pH 301 & pH 302. Silicon
HI 7669/2W General purpose probe for HI 8314, HI 8424 & HI 8915. Silicon
HI 7662 General purpose probe for HI 931100, HI 931101& HI 931102. Silicon

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.