| HI 3500 Mini-Titration System | |
![]() |
In order to perform titration, you must either use a chemical test kit or an automatic titrator. Chemical test kits are very reliable, but they have poor resolution. Automatic titrators have very high resolution, but are very complex, hard to use and expensive. Until now, there was no middle point between the two. Once again, Hanna is the first in the world to offer a simple to use manual titrator. HI 3500 is easy to understand and very reliable. The high resolution (0.01 pH, 0.1 mL) makes it perfect for use in labs and the field. |
HI 3500 consists of several components which can also be purchased separately:
| Specifications: | ||
| Part # | Description | Suggested Retail Price* |
| HI 3500D | Mini Titration System, including HI 3050N pH meter with built-in stirrer, HI 3500A Burette, HI 3500B reagent container, HI 3500C rubber bulb, HI 76503 magnetic stir bar, HI 1217D pH/°C electrode, HI 76405A electrode holder arm, HI 76405B steel base, 220/240V | $595 |
| HI 3500U | Mini Titration System, including HI 3050N pH meter with built-in stirrer, HI 3500A Burette, HI 3500B reagent container, HI 3500C rubber bulb, HI 76503 magnetic stir bar, HI 1217D pH/°C electrode, HI 76405A electrode holder arm, HI 76405B steel base, 110/115V | $575 |
| HI 3050N/D | pH meter with built-in stirrer for manual titration, automatic temperature compensation, set point and acoustic alarm. Supplied complete with 4-in-1, plastic-body, gel HI 1217D pH/°C electrode & stir bar, 220/240V | $425 |
| HI 3050N/U | pH meter with built-in stirrer for manual titration, automatic temperature compensation, set point and acoustic alarm. Supplied complete with 4-in-1, plastic-body, gel HI 1217D pH/°C electrode & stir bar, 110/115V | $425 |
| HI 3500A-1 | 10 mL Glass Dosing Burette (increments of .01 mL) | $67.00 |
| HI 3500A-2 | 25 mL Glass Dosing Burette (increments of .01 mL) | $67.00 |
| HI 3500A-3 | 50 mL Glass Dosing Burette (increments of .01 mL) | $67.00 |
| HI 3500B | Rugged glass reagent container with 0.4 L volume with rubber cap | $15.00 |
| HI 76405A | Cantilever arm to hold electrodes | $50.00 |
| HI 76405B | Enamel-coated steel base to hold components | $40.00 |
| PL 100 Free Chlorine Measurement through Amperometric Titration | |
![]() |
Hanna has manufactured two compact amperometric titrators for you to
choose from. PL 100, shown here, measures Free Chlorine while PL 101 is especially
designed for Total Chlorine measurements. Both models are supplied with a built-in stirrer
to maximize your lab space and optimize test results - all at a competitive price
|
The Hanna amperometric titration system measures the electrical current between two platinum electrodes of a probe. The platinum electrodes are immersed in a known quantity of a sample containing an unknown concentration of the chemical to be determined. The titration of Free Chlorine can be carried out with a reducing compound such as Sodium Thiosulphate or Phenylarsine Oxide (PAO). When a small voltage of about 0.10V is applied across the two platinum electrodes a small electrical current is generated inside the solution. A reversible reaction (Cl2 + 2e <=> 2Cl-) occurs at both electrodes as the reducible form is oxidized at the anode and the oxidized form is reduced at the cathode. The gradual addition of the reductant (titrant) irreversibly reduces the oxidized form of the Chlorine present. The final removal of all oxidized Chlorine terminates the reversible reaction and the probe current drops to zero. The concentration of Chlorine present in the sample is simply calculated by determining the exact amount of reductant added to extinguish the probe current.
PL 100C is supplied complete with HI 3500A-2 25 mL burette, HI 3500B reagent container, HI 3500C rubber bulb, HI 76503 50 mm (2") long (dia. 7 mm/0.3") magnetic stir bar, HI 3132B glass-body platinum-platinum electrode with 1 m (3.3") cable and BNC connector, HI 76405A electrode holder arm, HI 76405B steel base, HI 710005 or HI 710006 power adapter, recorder plug and instruction manual.
The PL 100 is supplied with 12VDC adapter and instruction manual.
| Specifications: | PL 100 |
| Range | 0.00 to 2.00 µA (probe current) |
| Accuracy (@20°C/68°F) | ±1% of reading or ±0.01 µA, whichever greater |
| Stirrer Speed | Constant at 300 ±10 rpm |
| Recorder Output | 0.00 to 2.00V corresponding to 0.00 to 2.00 µA |
| Power Supply | HI 710005 or HI 710006 12VDC adapter |
| Environment | 0 to 50°C (32 to 122°F); max. RH 95% non-condensing |
| Dimensions | 180 x 180 x 70 mm (7.1 x 7.1 x 2.8") |
| Weight | 1.6 Kg (3.6 lbs.) |
| PL 101 Amperometric Titrator for Total Chlorine Measurement | |
![]() |
PL 101 has been designed for rapid and accurate determination of total
chlorine content of a sample. The amperometric method is often recommended for determining
minute traces of chlorine, since it provides a greater degree of accuracy. Amperometric
Titrators are used in wastewater, drinking water and ultra pure water applications
|
PL 101 operates by providing a constant voltage to a dual platinum probe. As the titration proceeds, the electrode current changes and at an endpoint, the slope of the current curve drops abruptly to zero. Sample concentration is then derived from the endpoint value. The built-in stirrer uses a constant 300 rpm speed. The stirrer velocity is such to aid a rapid dilution of reductants yet not cause volatilization of the sample. Both PL 100 and PL 101 are powered by 12VDC adapter for safety and reduction of EMI. The probe voltage scale is 0 to 750VDC while the current is in the 0.00 to 2.00 µA range. The instrument case features a stainless steel top and a large 3 digit LCD display for viewing the probe current. The probe voltage can be electronically adjusted by the operator. Digital potentiometer setting is controlled by two "UP" and "DOWN" buttons right on the front panel. A static digital memory retains the set value even if power is suddenly lost or interrupted. PL 101 also features a recorder output which provides a low impedance voltage from 0.00 to 2.00V corresponding to the probe current of 0.00 to 2.00 µA.
PL 101C is supplied complete with HI 3500A-2 25 mL burette, HI 3500B reagent container, HI 3500C rubber bulb, HI 76503 50 mm (2") long (dia. 7 mm/0.3") magnetic stir bar, HI 3132B glass-body platinum-platinum electrode with 1 m (3.3") cable and BNC connector, HI 76405A electrode holder arm, HI 76405B steel base, HI 710005 or HI 710006 power adapter, recorder plug and instruction manual.
PL 101 is supplied with 12VDC adapter and instruction manual.
| Specifications: | PL 101 |
| Range | 0.00 to 2.00 µA (probe current) |
| Accuracy (@20°C/68°F) | ±1% of reading or ±0.01 µA, whichever greater |
| Stirrer Speed | Constant at 300 ±10 rpm |
| Recorder Output | 0.00 to 2.00V corresponding to 0.00 to 2.00 µA |
| Power Supply | HI 710005 or HI 710006 12VDC adapter |
| Environment | 0 to 50°C (32 to 122°F); max. RH 95% non-condensing |
| Dimensions | 180 x 180 x 70 mm (7.1 x 7.1 x 2.8") |
| Weight | 1.6 Kg (3.6 lbs.) |
|