• Highly Accurate
  • Simplicity of use
  • Wide Range

About Chemical Oxygen Demand
C 99 Chemical Oxygen Meter
C 9800 Test Tube Heater/Reactor
COD Reagents
C 99 Tailor-Made Accessories

Hanna’s COD analyzer is a powerful multi-parameter ion specific meter ideal for municipal water/wastewater treatment facilities. The C 99 measures up to 36 parameters and is engineered to be easy to operate and provide accurate, consistent results every time. C 99 along with Hanna’s C 9800 reactor & pre-dosed reagents are all you need to perform simple COD analysis in just a few short hours. The COD measurement procedure is based on the well-established Closed Reflux Colorimetric Method over 3 ranges: 0 to 150 mg/L, 0 to 1,500 mg/L and 0 to 15,000 mg/L. The analyzer has been designed for ease of use by personnel at all skill levels. It uses an advanced optical system, based on special tungsten lamps and narrow band filters, for highly accurate, repeatable readings. There is no need for complicated programming or installation of delicate filters. Hanna’s pre-dosed reagents reduce waste by minimizing the amount of necessary chemicals to properly test COD levels. Hanna also offers a recycling program to help with the safe and proper disposal of your reacted sample materials.


Tailor-Made Accessories
Choose from an array of spare parts and accessories designed to make your measurements simpler and safer:
  • C 9800-01 Hanna Reactor (115 VAC)
  • C 9800-02 Hanna Reactor (230 VAC)
  • HI 740142 Graduated syringe
  • HI 740143 Graduated syringe (6 pcs)
  • HI 740216 Test tube cooling rack (25 holes)
  • HI 740217 Laboratory bench safety shield
  • HI 740219 COD test tube adapter
  • HI 93703-50 Cuvet cleaning solution (230 mL)
  • HI 731318 Tissue for wiping cuvets (4 pcs)
  • HI 731321 Measurement cuvets (4 pcs)
  • HI 731325N Cuvet caps (4 pcs)
  • HI 92000 Windows® compatible software
    for C 99 series
  • HI 920010 9 to 9-pin connection cable

Spare COD Reagents Kits:

  • HI 93754A 0-150 mg/L
  • HI 93754B 0-1500 mg/L
  • HI 93754C 0-15000 mg/L

Most of the other spare reagents come in kits for 100 or 300 tests.
(See Table)

Each kit contains all the necessary reagents properly marked to avoid any use out of sequence.

Most of them are in powder form. These powder packets are pre-weighed. No time is wasted during the measurements: just open the packet and add the entire contents to the cuvet.

Liquid reagents are supplied with a graduated syringe for precise dosing.


  • Official Dichromate Method: Hanna Instruments' COD reagents are developed under the highest quality control standards in accordance with Standard Methods 5220D and USEPA Method 410.4.
  • Three ranges for different needs:
    • HI 93754A 0-150 mg/L
    • HI 93754B 0-1500 mg/L
    • HI 93754C 0-15000 mg/L
  • Sample size: Each pre-dosed vial has a diameter of 16mm and only a small amount of sample need be added
  • Pre-dosed vials for fast measurements: With Hanna’s pre-dosed vials, test preparation time is dramatically reduced. There is no time-consuming reagent preparation procedure or glassware cleaning.
  • View other Hanna Reagents (See Table)

Easy to use:
Using Hanna's pre-dosed test tubes, even a novice can run accurate COD tests in just 3 simple steps:
Step 1:
 Fill the pre-dosed vial with the sample.
Step 2:
 Place the vial in the reactor and set the timer.
Step 3:
 
Place the vial in the Hanna
C 99
and read the results.



Hanna Instruments is proud to introduce the new C 99 COD meter. This new, compact photometer operates in three different ranges to cover virtually every application: 0-150 mg/L, 0-1500 mg/L and 0-15000 mg/L.

The C 99 meets the design requirements of USEPA 410.4, guaranteeing high quality measurements to be used for reporting purposes.

 


  • Built-in RS232 port - The C 99 can be operated manually or from the PC. Data can be downloaded for analysis and documentation purposes with Hanna's optional HI 92000 software.
  • COD measurement made easy - The C 99 multi-parameter photometer is pre-calibrated to measure COD levels at three ranges. Simply use the scroll button to select the desired range and begin reading. The C 99 automatically selects the correct wavelength for the chosen range.
  • Outstanding measurement quality - The C 99 employs an advanced optical system assuring high accuracy measurements in the entire measurement range. The optics combine the power of a miniature light source with the precision of a narrow-band interference filter.
  • Save space in your laboratory - Measuring 23 x 17 x 7 cm and weighing less than 700 grams, the C 99 can easily be transported from place to place.

    C 99
    is supplied with 3 cuvets, transport cap, 2 x 9 V batteries, 12 VDC transformer (HI 710005 or HI 710006) and instruction manual.


C 99 Specifications Low Range Med. Range High Range
Range 0 - 150 mg/L 0 - 1500 mg/L 0 - 15000 mg/L
Resolution 1 mg/L 1 mg/L 10 mg/L
Precision (std. dev.) (@150 mg/L) ±4 mg/L (@ 1000 mg/L) ±22 mg/L (@10000 mg/L) ±220 mg/L
Typical EMC Deviation ±1 mg/L ±1 mg/L ±10 mg/L
Light Source Tungsten lamp Tungsten lamp Tungsten lamp
Wavelength 420 nm 610 nm 610 nm
Method Adaptation of the EPA 410.4 approved method.
Computer Interface RS232C
Power Supply 12 VDC power adapter / 2 x 9V battery
Dimensions 230 x 165 x 70 mm (9.0 x 6.5 x 2.8”)
Weight 640 g (22.6 oz.)

C 99: A Complete Laboratory at Your Fingertips!

C 99 is one of the most versatile photometers on the market. In addition to COD, this meter measures 36 of the most important water quality parameters. The C 99 runs for hours on two 9V batteries. In addition, it can operate continuously with the included 12 VDC power adapter. C 99 is also extremely simple to use. The front mask lists all the parameters in numerical order and the display shows the same numbers for a quick reference during testing.
Test Range Method Reagent Code
Aluminum 0.00 to 1.00 mg/L Aluminon HI 93712-01
Ammonia HR 0.00 to 9.99 mg/L Nessler HI 93715-01
Ammonia LR 0.00 to 3.00 mg/L Nessler HI 93700-01
Bromine 0.00 to 8.00 mg/L DPD HI 93716-01
Free Chlorine 0.00 to 2.50 mg/L DPD HI 93701-01
Total Chlorine 0.00 to 3.50 mg/L DPD HI 93711-01
Chlorine Dioxide 0.00 to 2.00 mg/L Chlorophenol Red HI 93738-01
Chromium VI HR 0 to 1000 µg/L Diphenylcarbohydrazide HI 93723-01
Chromium VI LR 0 to 300 µg/L Diphenylcarbohydrazide HI 93749-01
COD LR 0 to 150 mg/L Dichromate HI 93754A-25
COD MR 0 to 1500 mg/L Dichromate HI 93754B-25
COD HR 0 to 15000 mg/L Dichromate HI 93754C-25
Color 0 to 500 PCU Chloroplatinate
Copper HR 0.00 to 5.00 mg/L Bicinchoninate HI 93702-01
Copper LR 0 to 990 µg/L Bicinchoninate HI 93747-01
Cyanide 0.000 to 0.200 mg/L Pyridine-Pyrazalone HI 93714-01
Cyanuric Acid 0 to 80 mg/L Turbidimetric HI 93722-01
Fluoride 0.00 to 2.00 mg/L SPADNS HI 93729-01
Ca Hardness 0.00 to 2.70 mg/L Calmagite HI 93720-01
Mg Hardness 0.00 to 2.00 mg/L EDTA HI 93719-01
Hydrazine 0 to 400 µg/L p-Dimethylaminobenzaldehyde HI 93704-01
Iodine 0.0 to 12.5 mg/L DPD HI 93718-01
Iron HR 0.00 to 5.00 mg/L Phenantroline HI 93721-01
Iron LR 0 to 400 µg/L TPTZ HI 93746-01
Manganese HR 0.0 to 20.0 mg/L Periodate Oxidation HI 93709-01
Manganese LR 0 to 300 µg/L PAN HI 93748-01
Molybdenum 0.0 to 40.0 mg/L Mercaptoacetic Acid HI 93730-01
Nickel HR 0.00 to 7.00 g/L Photometric HI 93726-01
Nitrate 0.0 to 30.0 mg/L Cadmium Reduction HI 93728-01
Nitrite HR 0 to 150 mg/L Ferrous Sulfate HI 93708-01
Nitrite LR 0.00 to 0.35 mg/L Diazotization HI 93707-01
Dissolved Oxygen 0.0 to 10.0 mg/L Winkler HI 93732-01
pH 6.5 to 8.5 pH Phenol Red HI 93710-01
Phosphate HR 0.0 to 30.0 mg/L Amino Acid HI 93717-01
Phosphate LR 0.00 to 2.50 mg/L Ascorbic Acid HI 93713-01
Phosphorus 0.0 to 15.0 mg/L Amino Acid HI 93706-01
Silica 0.00 to 2.00 mg/L Heteropoly blue HI 93705-01
Silver 0.000 to 1.000 mg/L PAN HI 93737-01
Zinc 0.00 to 3.00 mg/L Zincon HI 93731-01


C 9800 Test Tube Heater
  • 25 Vial (16 mm) Heating Block ideal for performing large numbers of tests and increasing productivity
  • Factory Calibration provides a maintainted accuracy of ±2°C
  • Timer allows the reaction to take place unattended. After digestion, the C 9800 shuts off automatically.
  • Order Information
  • Specifications

C 9800 thermoreactor is constructed of durable materials with a vial capacity to perform up to 25 digestions simultaneously. The reactor is equipped with a user-selectable temperature setting to allow for COD and total phosphorus reactions at 150 ºC and also 105 ºC for total nitrogen analysis. To ensure the highest accuracy of digestion, a timer up to 120 minutes is incorporated. An audible alarm indicates when the incubating period is completed. The C 9800 is also equipped with an ON/OFF LED and a heating LED which advises the user when the selected temperature has been reached. For added safety, an auto-off feature is incorporated and an internal temperature sensor prevents over-heating of the samples.

Specifications C 9800-01 C 9800-02
Ambient Operation Temperature +5 to +50 °C
Storage Temperature -20 to +60 °C
Temperature Stability ±0.5 °C
Capacity 25 (16 x 100 mm vials), 1 receptacle for stainless steel probe thermometer
Accuracy ±2 °C @ 25 °C ambient
Warm-up Time 30-40 minutes, depending on set temperature
Temperature Setting Selectable temperature @ 105 °C or 150 °C
Operating Mode Timed procedure (0 - 20 min.) or infinity mode
Timer 0-120 minutes with acoustic alarm and automatic shut-off mode
Clock Aluminum
Power Requirements 115 VAC; 60Hz; 250W; Fuse 4A 230 VAC; 50Hz; 250W; Fuse 2A
Dimensions 190 x 300 x 95 mm (7.5 x 11.8 x 3”)
Weight Approx. 4.8 kg (10.6 lb.)


C 99 Chemical Oxygen Demand Meter - COD Made Easy

Hanna Instruments is proud to introduce the new C 99 COD meter. This new, compact photometer operates in three different ranges to cover virtually every application: 0-150 mg/L, 0-1500 mg/L and 0-15000 mg/L.

The C 99 meets the design requirements of USEPA 410.4, guaranteeing high quality measurements to be used for reporting purposes.

 


  • Built-in RS232 port - The C 99 can be operated manually or from the PC. Data can be downloaded for analysis and documentation purposes with Hanna's optional HI 92000 software.
  • COD measurement made easy - The C 99 multi-parameter photometer is pre-calibrated to measure COD levels at three ranges. Simply use the scroll button to select the desired range and begin reading. The C 99 automatically selects the correct wavelength for the chosen range.
  • Outstanding measurement quality - The C 99 employs an advanced optical system assuring high accuracy measurements in the entire measurement range. The optics combine the power of a miniature light source with the precision of a narrow-band interference filter.
  • Save space in your laboratory - Measuring 23 x 17 x 7 cm and weighing less than 700 grams, the C 99 can easily be transported from place to place.

    C 99
    is supplied with 3 cuvets, transport cap, 2 x 9 V batteries, 12 VDC transformer (HI 710005 or HI 710006) and instruction manual.


C 99 Specifications Low Range Med. Range High Range
Range 0 - 150 mg/L 0 - 1500 mg/L 0 - 15000 mg/L
Resolution 1 mg/L 1 mg/L 10 mg/L
Precision (std. dev.) (@150 mg/L) ±4 mg/L (@ 1000 mg/L) ±22 mg/L (@10000 mg/L) ±220 mg/L
Typical EMC Deviation ±1 mg/L ±1 mg/L ±10 mg/L
Light Source Tungsten lamp Tungsten lamp Tungsten lamp
Wavelength 420 nm 610 nm 610 nm
Method Adaptation of the EPA 410.4 approved method.
Computer Interface RS232C
Power Supply 12 VDC power adapter / 2 x 9V battery
Dimensions 230 x 165 x 70 mm (9.0 x 6.5 x 2.8”)
Weight 640 g (22.6 oz.)

C 99: A Complete Laboratory at Your Fingertips!

C 99 is one of the most versatile photometers on the market. In addition to COD, this meter measures 36 of the most important water quality parameters. The C 99 runs for hours on two 9V batteries. In addition, it can operate continuously with the included 12 VDC power adapter. C 99 is also extremely simple to use. The front mask lists all the parameters in numerical order and the display shows the same numbers for a quick reference during testing.
Test Range Method Reagent Code
Aluminum 0.00 to 1.00 mg/L Aluminon HI 93712-01
Ammonia HR 0.00 to 9.99 mg/L Nessler HI 93715-01
Ammonia LR 0.00 to 3.00 mg/L Nessler HI 93700-01
Bromine 0.00 to 8.00 mg/L DPD HI 93716-01
Free Chlorine 0.00 to 2.50 mg/L DPD HI 93701-01
Total Chlorine 0.00 to 3.50 mg/L DPD HI 93711-01
Chlorine Dioxide 0.00 to 2.00 mg/L Chlorophenol Red HI 93738-01
Chromium VI HR 0 to 1000 µg/L Diphenylcarbohydrazide HI 93723-01
Chromium VI LR 0 to 300 µg/L Diphenylcarbohydrazide HI 93749-01
COD LR 0 to 150 mg/L Dichromate HI 93754A-25
COD MR 0 to 1500 mg/L Dichromate HI 93754B-25
COD HR 0 to 15000 mg/L Dichromate HI 93754C-25
Color 0 to 500 PCU Chloroplatinate
Copper HR 0.00 to 5.00 mg/L Bicinchoninate HI 93702-01
Copper LR 0 to 990 µg/L Bicinchoninate HI 93747-01
Cyanide 0.000 to 0.200 mg/L Pyridine-Pyrazalone HI 93714-01
Cyanuric Acid 0 to 80 mg/L Turbidimetric HI 93722-01
Fluoride 0.00 to 2.00 mg/L SPADNS HI 93729-01
Ca Hardness 0.00 to 2.70 mg/L Calmagite HI 93720-01
Mg Hardness 0.00 to 2.00 mg/L EDTA HI 93719-01
Hydrazine 0 to 400 µg/L p-Dimethylaminobenzaldehyde HI 93704-01
Iodine 0.0 to 12.5 mg/L DPD HI 93718-01
Iron HR 0.00 to 5.00 mg/L Phenantroline HI 93721-01
Iron LR 0 to 400 µg/L TPTZ HI 93746-01
Manganese HR 0.0 to 20.0 mg/L Periodate Oxidation HI 93709-01
Manganese LR 0 to 300 µg/L PAN HI 93748-01
Molybdenum 0.0 to 40.0 mg/L Mercaptoacetic Acid HI 93730-01
Nickel HR 0.00 to 7.00 g/L Photometric HI 93726-01
Nitrate 0.0 to 30.0 mg/L Cadmium Reduction HI 93728-01
Nitrite HR 0 to 150 mg/L Ferrous Sulfate HI 93708-01
Nitrite LR 0.00 to 0.35 mg/L Diazotization HI 93707-01
Dissolved Oxygen 0.0 to 10.0 mg/L Winkler HI 93732-01
pH 6.5 to 8.5 pH Phenol Red HI 93710-01
Phosphate HR 0.0 to 30.0 mg/L Amino Acid HI 93717-01
Phosphate LR 0.00 to 2.50 mg/L Ascorbic Acid HI 93713-01
Phosphorus 0.0 to 15.0 mg/L Amino Acid HI 93706-01
Silica 0.00 to 2.00 mg/L Heteropoly blue HI 93705-01
Silver 0.000 to 1.000 mg/L PAN HI 93737-01
Zinc 0.00 to 3.00 mg/L Zincon HI 93731-01

About Chemical Oxygen Demand (COD)

     
   
COD Testing Applied
Oxygen Demand and COD
Official Reporting Method
The Hanna COD System
   
   

COD testing applied
COD
is used as a measurement of pollutants in natural and waste waters to assess the strength of discharged waste such as sewage and industrial effluent waters. It is normally measured in both municipal and industrial wastewater treatment plants and gives an indication of the efficiency of the treatment process. COD is measured in both influent and effluent water (before and after treatment). The efficiency of the treatment process is normally expressed as COD Removal, measured as a percentage of the organic matter removed during the cycle.

COD
has further applications in power plant operations, chemical manufacturing, commercial laundries, pulp & paper mills, agriculture & animal waste runoff, environmental studies and general education. The C 99 colorimeter can be used in the laboratory setting or field site testing by personnel at any skill level.. Back to Top

Oxygen Demand and COD
Untreated wastewater is generally rich in organic matter. This organic matter feeds the bacteria and algae normally present in healthy water sources. The presence of excessive amounts of nutrients discharged as a result of untreated wastewater will cause an increase in concentration of both bacteria and algae within the surface water. Beside organic matter, wastewater also contains both organic and oxidizable inorganic compounds. These organic and inorganic compounds directly and indirectly consume the available oxygen present in the ecosystem. This process is called eutrification and will eventually kill off other living organisms (plants, animals, & insects) in the aquatic system.
Governments strictly control these oxygen demanding pollutants by setting standards for maximum levels of “oxygen demand” for all discharged wastewaters. There are different methods known for measuring the oxygen demand but BOD (Biological Oxygen Demand) and COD (Chemical Oxygen Demand) are the most widely accepted methods. The COD test has many advantages over the BOD method. The COD test is more accurate and faster than the BOD method. The BOD method requires a five to seven day incubation period and is more subject to operator errors. The COD method usually takes under three hours and is easy to perform by technical and non-technical personnel alike. Hanna’s COD method also uses a special anti-interference agent that removes chloride interference. Back to Top

Official Reporting Method
Chemical Oxygen Demand (COD) is defined as the amount of specified oxidant that reacts with a sample under controlled conditions. The quantity of oxygen consumed is expressed in terms of its oxygen equivalent: mg/L of O2.
The Hanna COD method is based on the well established Closed Dichromate-Reflux Colorimetric Method and is in accordance with the two main official courses for chemical analysis in water and wastewater: “Standard Methods for the Examination of Water and Wastewater” (20th ed.) Method #5220D and “US Environmental Protection Agency, Methods and Guidance for Analyses of Water” (2nd ed.) EPA Method #410.4.
Furthermore, the US Environmental Protection Agency specifies that the dichromate reflux method is the only method acceptable for reporting purposes. The advantage in using this method includes highly accurate certifiable results. Back to Top

The Hanna COD System
The Hanna closed-reflux colorimetric COD system complies with the EPA recommended method, and all other recommended applications that are based on the potassium dichromate method. The individual components of the system are designed to interface with existing closed-reflux colorimetric test systems or to supply everything needed to perform simple COD tests in a few hours.

Our pre-dosed reagents have been developed to minimize the amount of required testing sample, reagent chemicals and the subsequent waste. Hanna has taken special precautions to remove any potential interference that may be caused by the presence of Chloride within the sample solution

As COD levels vary depending on the application and process measuring points, Hanna offers reagents to cover three separate ranges. Simply select the most appropriate range for the application. Each box of 25 vials is supplied with a Reagent Quality Certificate produced by our quality assurance team. The reagents are traceable to NIST SRM® 930e.

HI 93754A
Low Range 0-150 mg/L
HI 93754B
Medium Range 0-1500 mg/L
HI 93754C
High Range 0-15000 mg/L

The organic and inorganic compounds present in the water sample are oxidized under strong chromic acid conditions during a two-hour digestion period at 150°C in a preheated reactor.
The Hanna reactor C 9800 is a block heater type with an accurate temperature control system to ensure the digestion temperature is exactly 150°C ±2°C as required by Standard Methods. The C 9800 features a user-selectable timing mode (timed or infinite) and an acoustic alarm to alert the user that the digestion period is complete. In the timed mode, the reactor automatically switches off after the digestion has completed. During the digestion period, your safety is guaranteed using the HI 740217 protective shield.

After digestion, remove the vials from the reactor and place them in the HI 740216 cooling rack. When the vials are cooled down to about room temperature, direct COD readings can be obtained with the C 99 COD analyzer. Using the closed-reflux colorimetric method has many advantages over conventional methods.

With the Hanna COD solution, no volume correction is necessary after digestion. The colorimetric method is also advantageous because you are not required to perform time intensive and reagent consuming titrations as with other methods.
The C 99 multi-parameter photometer is a high precision instrument with an advanced optical system. A special microprocessor controlled tungsten lamp and narrow band optical filters allow extremely accurate and repeatable readings. This ion specific analyzer is programmed to test up to 39 parameters including COD. With the C 99, there is no need for complicated programming or installation of delicate filters. With a touch of a button, select the parameter you want to test and your photometer is ready for measurement. Back to Top

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117