- Highly Accurate
- Simplicity of use
- Wide Range
|
Hanna’s COD analyzer is a powerful multi-parameter
ion specific meter ideal for municipal water/wastewater treatment facilities.
The C 99 measures up to 36 parameters and is engineered
to be easy to operate and provide accurate, consistent results every time. C
99 along with Hanna’s C 9800 reactor
& pre-dosed reagents are all you need to perform simple COD
analysis in just a few short hours. The COD measurement
procedure is based on the well-established Closed Reflux Colorimetric Method
over 3
ranges: 0 to 150 mg/L, 0 to 1,500 mg/L and 0 to 15,000 mg/L. The
analyzer has been designed for ease of use by personnel at all skill levels.
It uses an advanced optical system, based on special tungsten lamps and narrow
band filters, for highly accurate, repeatable readings. There is no need
for
complicated programming or installation of delicate filters. Hanna’s
pre-dosed reagents reduce waste by minimizing the amount of necessary chemicals
to properly test COD levels. Hanna also offers a recycling
program to help with the safe and proper disposal of your reacted sample
materials.
|
| Tailor-Made Accessories
|
 |
| Choose from an array of spare
parts and accessories designed to make your measurements simpler and safer:
|
-
C 9800-01 Hanna Reactor (115 VAC)
-
C 9800-02 Hanna Reactor (230 VAC)
-
HI 740142 Graduated syringe
-
HI 740143 Graduated syringe (6 pcs)
-
HI 740216 Test tube cooling rack
(25 holes)
-
HI 740217 Laboratory bench safety
shield
-
HI 740219 COD test tube adapter
|
-
HI 93703-50 Cuvet cleaning solution
(230 mL)
-
HI 731318 Tissue for wiping cuvets
(4 pcs)
-
HI 731321 Measurement cuvets (4 pcs)
-
HI 731325N Cuvet caps (4 pcs)
-
HI 92000 Windows® compatible
software
for C 99 series
-
HI 920010 9 to 9-pin connection cable
|
| Spare COD Reagents Kits:
- HI 93754A 0-150 mg/L
- HI 93754B 0-1500 mg/L
- HI 93754C 0-15000 mg/L
Most of the other spare reagents come in kits for 100 or 300 tests.
(See Table)
Each kit contains all the necessary reagents properly marked to avoid
any use out of sequence.
Most of them are in powder form. These powder packets are pre-weighed.
No time is wasted during the measurements: just open the packet and add
the entire contents to the cuvet.
Liquid reagents are supplied with a graduated syringe for precise dosing. |
 |
|
|
| |
|
- Official Dichromate Method: Hanna Instruments' COD
reagents are developed under the highest quality control standards in
accordance with Standard Methods 5220D and USEPA Method 410.4.
- Three ranges for different needs:
- HI 93754A 0-150 mg/L
- HI 93754B 0-1500 mg/L
- HI 93754C 0-15000 mg/L
- Sample size: Each pre-dosed vial has a diameter of
16mm and only a small amount of sample need be added
- Pre-dosed vials for fast measurements: With Hanna’s
pre-dosed vials, test preparation time is dramatically reduced. There
is no time-consuming reagent preparation procedure or glassware cleaning.
- View other Hanna Reagents (See Table)
|
|
Easy
to use:
Using Hanna's pre-dosed test tubes, even a novice can run accurate COD
tests in just 3 simple steps: |
Step
1:
Fill the pre-dosed vial with the sample. |
Step
2:
Place the vial in the reactor and set the timer. |
Step 3:
Place the vial in the Hanna
C 99 and read the results. |
| 
|
 |
|
|
| |
Hanna Instruments is proud to introduce the
new C 99 COD meter. This new, compact photometer operates
in three different ranges to cover virtually every application: 0-150
mg/L, 0-1500 mg/L and 0-15000 mg/L.
The C 99 meets the design requirements of USEPA
410.4, guaranteeing high quality measurements to be used for reporting
purposes. |

|
|
|
|
- Built-in RS232 port - The C 99 can
be operated manually or from the PC. Data can be downloaded for analysis
and documentation purposes with Hanna's optional HI 92000
software.
- COD measurement made easy - The C 99
multi-parameter photometer is pre-calibrated to measure COD levels at
three ranges. Simply use the scroll button to select the desired range
and begin reading. The C 99 automatically selects the
correct wavelength for the chosen range.
- Outstanding measurement quality - The C 99
employs an advanced optical system assuring high accuracy measurements
in the entire measurement range. The optics combine the power of a miniature
light source with the precision of a narrow-band interference filter.
- Save space in your laboratory - Measuring 23 x 17
x 7 cm and weighing less than 700 grams, the C 99 can
easily be transported from place to place.
C 99 is supplied with 3 cuvets, transport cap, 2 x 9 V batteries,
12 VDC transformer (HI 710005 or HI 710006)
and instruction manual.
|
|
| C 99 Specifications |
Low Range |
Med. Range |
High Range |
| Range |
0 - 150 mg/L |
0 - 1500 mg/L |
0 - 15000 mg/L |
| Resolution |
1 mg/L |
1 mg/L |
10 mg/L |
| Precision (std. dev.) |
(@150 mg/L) ±4 mg/L |
(@ 1000 mg/L) ±22 mg/L |
(@10000 mg/L) ±220 mg/L |
| Typical EMC Deviation |
±1 mg/L |
±1 mg/L |
±10 mg/L |
| Light Source |
Tungsten lamp |
Tungsten lamp |
Tungsten lamp |
| Wavelength |
420 nm |
610 nm |
610 nm |
| Method |
Adaptation of the EPA
410.4 approved method. |
| Computer Interface |
RS232C |
| Power Supply |
12 VDC power adapter
/ 2 x 9V battery |
| Dimensions |
230 x 165 x 70 mm (9.0
x 6.5 x 2.8”) |
| Weight |
640 g (22.6 oz.) |
C 99: A Complete Laboratory at Your Fingertips!
| C 99 is one of the most versatile photometers on the
market. In addition to COD, this meter measures 36 of the
most important water quality parameters. The C 99 runs
for hours on two 9V batteries. In addition, it can operate continuously
with the included 12 VDC power adapter. C 99 is also extremely
simple to use. The front mask lists all the parameters in numerical order
and the display shows the same numbers for a quick reference during testing. |
| Test |
Range |
Method |
Reagent Code |
| Aluminum |
0.00 to 1.00 mg/L |
Aluminon |
HI 93712-01 |
| Ammonia HR |
0.00 to 9.99 mg/L |
Nessler |
HI 93715-01 |
| Ammonia LR |
0.00 to 3.00 mg/L |
Nessler |
HI 93700-01 |
| Bromine |
0.00 to 8.00 mg/L |
DPD |
HI 93716-01 |
| Free Chlorine |
0.00 to 2.50 mg/L |
DPD |
HI 93701-01 |
| Total Chlorine |
0.00 to 3.50 mg/L |
DPD |
HI 93711-01 |
| Chlorine Dioxide |
0.00 to 2.00 mg/L |
Chlorophenol Red |
HI 93738-01 |
| Chromium VI HR |
0 to 1000 µg/L |
Diphenylcarbohydrazide |
HI 93723-01 |
| Chromium VI LR |
0 to 300 µg/L |
Diphenylcarbohydrazide |
HI 93749-01 |
| COD LR |
0 to 150 mg/L |
Dichromate |
HI 93754A-25 |
| COD MR |
0 to 1500 mg/L |
Dichromate |
HI 93754B-25 |
| COD HR |
0 to 15000 mg/L |
Dichromate |
HI 93754C-25 |
| Color |
0 to 500 PCU |
Chloroplatinate |
— |
| Copper HR |
0.00 to 5.00 mg/L |
Bicinchoninate |
HI 93702-01 |
| Copper LR |
0 to 990 µg/L |
Bicinchoninate |
HI 93747-01 |
| Cyanide |
0.000 to 0.200 mg/L |
Pyridine-Pyrazalone |
HI 93714-01 |
| Cyanuric Acid |
0 to 80 mg/L |
Turbidimetric |
HI 93722-01 |
| Fluoride |
0.00 to 2.00 mg/L |
SPADNS |
HI 93729-01 |
| Ca Hardness |
0.00 to 2.70 mg/L |
Calmagite |
HI 93720-01 |
| Mg Hardness |
0.00 to 2.00 mg/L |
EDTA |
HI 93719-01 |
| Hydrazine |
0 to 400 µg/L |
p-Dimethylaminobenzaldehyde |
HI 93704-01 |
| Iodine |
0.0 to 12.5 mg/L |
DPD |
HI 93718-01 |
| Iron HR |
0.00 to 5.00 mg/L |
Phenantroline |
HI 93721-01 |
| Iron LR |
0 to 400 µg/L |
TPTZ |
HI 93746-01 |
| Manganese HR |
0.0 to 20.0 mg/L |
Periodate Oxidation |
HI 93709-01 |
| Manganese LR |
0 to 300 µg/L |
PAN |
HI 93748-01 |
| Molybdenum |
0.0 to 40.0 mg/L |
Mercaptoacetic Acid |
HI 93730-01 |
| Nickel HR |
0.00 to 7.00 g/L |
Photometric |
HI 93726-01 |
| Nitrate |
0.0 to 30.0 mg/L |
Cadmium Reduction |
HI 93728-01 |
| Nitrite HR |
0 to 150 mg/L |
Ferrous Sulfate |
HI 93708-01 |
| Nitrite LR |
0.00 to 0.35 mg/L |
Diazotization |
HI 93707-01 |
| Dissolved Oxygen |
0.0 to 10.0 mg/L |
Winkler |
HI 93732-01 |
| pH |
6.5 to 8.5 pH |
Phenol Red |
HI 93710-01 |
| Phosphate HR |
0.0 to 30.0 mg/L |
Amino Acid |
HI 93717-01 |
| Phosphate LR |
0.00 to 2.50 mg/L |
Ascorbic Acid |
HI 93713-01 |
| Phosphorus |
0.0 to 15.0 mg/L |
Amino Acid |
HI 93706-01 |
| Silica |
0.00 to 2.00 mg/L |
Heteropoly blue |
HI 93705-01 |
| Silver |
0.000 to 1.000 mg/L |
PAN |
HI 93737-01 |
| Zinc |
0.00 to 3.00 mg/L |
Zincon |
HI 93731-01 |
|
 |
C 9800 Test Tube Heater
- 25 Vial (16 mm) Heating Block ideal for performing
large numbers of tests and increasing productivity
- Factory Calibration provides a maintainted accuracy
of ±2°C
- Timer allows the reaction to take place unattended.
After digestion, the C 9800 shuts off automatically.
- Order Information
- Specifications
|
|
C 9800
thermoreactor is constructed of durable materials with
a vial capacity to perform up to 25 digestions simultaneously. The reactor is
equipped with a user-selectable temperature setting to allow for COD
and total phosphorus reactions at 150 ºC and also 105 ºC for total
nitrogen analysis. To ensure the highest accuracy of digestion, a timer up to
120 minutes is incorporated. An audible alarm indicates when the incubating
period is completed. The C 9800 is also equipped with an ON/OFF
LED and a heating LED which advises the user when the selected temperature has
been reached. For added safety, an auto-off feature is incorporated and an internal
temperature sensor prevents over-heating of the samples.
| Specifications |
C 9800-01 |
C 9800-02 |
| Ambient Operation Temperature |
+5 to +50 °C |
| Storage Temperature |
-20 to +60 °C |
| Temperature Stability |
±0.5 °C |
| Capacity |
25 (16 x 100 mm vials), 1 receptacle for stainless
steel probe thermometer |
| Accuracy |
±2 °C @ 25 °C ambient |
| Warm-up Time |
30-40 minutes, depending on set temperature |
| Temperature Setting |
Selectable temperature @ 105 °C or 150
°C |
| Operating Mode |
Timed procedure (0 - 20 min.) or infinity mode |
| Timer |
0-120 minutes with acoustic alarm and automatic
shut-off mode |
| Clock |
Aluminum |
| Power Requirements |
115 VAC; 60Hz; 250W; Fuse 4A |
230 VAC; 50Hz; 250W; Fuse 2A |
| Dimensions |
190 x 300 x 95 mm (7.5 x 11.8 x 3”) |
| Weight |
Approx. 4.8 kg (10.6 lb.) |
|
| C 99 Chemical Oxygen
Demand Meter - COD Made Easy |
Hanna Instruments is proud to introduce the
new C 99 COD meter. This new, compact photometer operates
in three different ranges to cover virtually every application: 0-150
mg/L, 0-1500 mg/L and 0-15000 mg/L.
The C 99 meets the design requirements of USEPA
410.4, guaranteeing high quality measurements to be used for reporting
purposes. |

|
|
|
|
- Built-in RS232 port - The C 99 can
be operated manually or from the PC. Data can be downloaded for analysis
and documentation purposes with Hanna's optional HI 92000
software.
- COD measurement made easy - The C 99
multi-parameter photometer is pre-calibrated to measure COD levels at
three ranges. Simply use the scroll button to select the desired range
and begin reading. The C 99 automatically selects the
correct wavelength for the chosen range.
- Outstanding measurement quality - The C 99
employs an advanced optical system assuring high accuracy measurements
in the entire measurement range. The optics combine the power of a miniature
light source with the precision of a narrow-band interference filter.
- Save space in your laboratory - Measuring 23 x 17
x 7 cm and weighing less than 700 grams, the C 99 can
easily be transported from place to place.
C 99 is supplied with 3 cuvets, transport cap, 2 x 9 V batteries,
12 VDC transformer (HI 710005 or HI 710006)
and instruction manual.
|
|
| C 99 Specifications |
Low Range |
Med. Range |
High Range |
| Range |
0 - 150 mg/L |
0 - 1500 mg/L |
0 - 15000 mg/L |
| Resolution |
1 mg/L |
1 mg/L |
10 mg/L |
| Precision (std. dev.) |
(@150 mg/L) ±4 mg/L |
(@ 1000 mg/L) ±22 mg/L |
(@10000 mg/L) ±220 mg/L |
| Typical EMC Deviation |
±1 mg/L |
±1 mg/L |
±10 mg/L |
| Light Source |
Tungsten lamp |
Tungsten lamp |
Tungsten lamp |
| Wavelength |
420 nm |
610 nm |
610 nm |
| Method |
Adaptation of the EPA
410.4 approved method. |
| Computer Interface |
RS232C |
| Power Supply |
12 VDC power adapter
/ 2 x 9V battery |
| Dimensions |
230 x 165 x 70 mm (9.0
x 6.5 x 2.8”) |
| Weight |
640 g (22.6 oz.) |
C 99: A Complete Laboratory at Your Fingertips!
| C 99 is one of the most versatile photometers on the
market. In addition to COD, this meter measures 36 of the
most important water quality parameters. The C 99 runs
for hours on two 9V batteries. In addition, it can operate continuously
with the included 12 VDC power adapter. C 99 is also extremely
simple to use. The front mask lists all the parameters in numerical order
and the display shows the same numbers for a quick reference during testing. |
| Test |
Range |
Method |
Reagent Code |
| Aluminum |
0.00 to 1.00 mg/L |
Aluminon |
HI 93712-01 |
| Ammonia HR |
0.00 to 9.99 mg/L |
Nessler |
HI 93715-01 |
| Ammonia LR |
0.00 to 3.00 mg/L |
Nessler |
HI 93700-01 |
| Bromine |
0.00 to 8.00 mg/L |
DPD |
HI 93716-01 |
| Free Chlorine |
0.00 to 2.50 mg/L |
DPD |
HI 93701-01 |
| Total Chlorine |
0.00 to 3.50 mg/L |
DPD |
HI 93711-01 |
| Chlorine Dioxide |
0.00 to 2.00 mg/L |
Chlorophenol Red |
HI 93738-01 |
| Chromium VI HR |
0 to 1000 µg/L |
Diphenylcarbohydrazide |
HI 93723-01 |
| Chromium VI LR |
0 to 300 µg/L |
Diphenylcarbohydrazide |
HI 93749-01 |
| COD LR |
0 to 150 mg/L |
Dichromate |
HI 93754A-25 |
| COD MR |
0 to 1500 mg/L |
Dichromate |
HI 93754B-25 |
| COD HR |
0 to 15000 mg/L |
Dichromate |
HI 93754C-25 |
| Color |
0 to 500 PCU |
Chloroplatinate |
— |
| Copper HR |
0.00 to 5.00 mg/L |
Bicinchoninate |
HI 93702-01 |
| Copper LR |
0 to 990 µg/L |
Bicinchoninate |
HI 93747-01 |
| Cyanide |
0.000 to 0.200 mg/L |
Pyridine-Pyrazalone |
HI 93714-01 |
| Cyanuric Acid |
0 to 80 mg/L |
Turbidimetric |
HI 93722-01 |
| Fluoride |
0.00 to 2.00 mg/L |
SPADNS |
HI 93729-01 |
| Ca Hardness |
0.00 to 2.70 mg/L |
Calmagite |
HI 93720-01 |
| Mg Hardness |
0.00 to 2.00 mg/L |
EDTA |
HI 93719-01 |
| Hydrazine |
0 to 400 µg/L |
p-Dimethylaminobenzaldehyde |
HI 93704-01 |
| Iodine |
0.0 to 12.5 mg/L |
DPD |
HI 93718-01 |
| Iron HR |
0.00 to 5.00 mg/L |
Phenantroline |
HI 93721-01 |
| Iron LR |
0 to 400 µg/L |
TPTZ |
HI 93746-01 |
| Manganese HR |
0.0 to 20.0 mg/L |
Periodate Oxidation |
HI 93709-01 |
| Manganese LR |
0 to 300 µg/L |
PAN |
HI 93748-01 |
| Molybdenum |
0.0 to 40.0 mg/L |
Mercaptoacetic Acid |
HI 93730-01 |
| Nickel HR |
0.00 to 7.00 g/L |
Photometric |
HI 93726-01 |
| Nitrate |
0.0 to 30.0 mg/L |
Cadmium Reduction |
HI 93728-01 |
| Nitrite HR |
0 to 150 mg/L |
Ferrous Sulfate |
HI 93708-01 |
| Nitrite LR |
0.00 to 0.35 mg/L |
Diazotization |
HI 93707-01 |
| Dissolved Oxygen |
0.0 to 10.0 mg/L |
Winkler |
HI 93732-01 |
| pH |
6.5 to 8.5 pH |
Phenol Red |
HI 93710-01 |
| Phosphate HR |
0.0 to 30.0 mg/L |
Amino Acid |
HI 93717-01 |
| Phosphate LR |
0.00 to 2.50 mg/L |
Ascorbic Acid |
HI 93713-01 |
| Phosphorus |
0.0 to 15.0 mg/L |
Amino Acid |
HI 93706-01 |
| Silica |
0.00 to 2.00 mg/L |
Heteropoly blue |
HI 93705-01 |
| Silver |
0.000 to 1.000 mg/L |
PAN |
HI 93737-01 |
| Zinc |
0.00 to 3.00 mg/L |
Zincon |
HI 93731-01 |
About Chemical
Oxygen Demand (COD)
| COD
testing applied
COD is used as
a measurement of pollutants in natural and waste waters to assess the
strength of discharged waste such as sewage and industrial effluent waters.
It is normally measured in both municipal and industrial wastewater treatment
plants and gives an indication of the efficiency of the treatment process.
COD is measured in both influent and effluent water (before
and after treatment). The efficiency of the treatment process is normally
expressed as COD Removal, measured as a percentage of
the organic matter removed during the cycle.
COD has further applications in power plant operations, chemical
manufacturing, commercial laundries, pulp & paper mills, agriculture
& animal waste runoff, environmental studies and general education.
The C 99 colorimeter can be used in the laboratory setting
or field site testing by personnel at any skill level.. Back
to Top
Oxygen
Demand and COD
Untreated wastewater is generally rich in organic matter. This organic
matter feeds the bacteria and algae normally present in healthy water
sources. The presence of excessive amounts of nutrients discharged as
a result of untreated wastewater will cause an increase in concentration
of both bacteria and algae within the surface water. Beside organic matter,
wastewater also contains both organic and oxidizable inorganic compounds.
These organic and inorganic compounds directly and indirectly consume
the available oxygen present in the ecosystem. This process is called
eutrification and will eventually kill off other living organisms (plants,
animals, & insects) in the aquatic system.
Governments strictly control these oxygen demanding pollutants by setting
standards for maximum levels of “oxygen demand” for all discharged
wastewaters. There are different methods known for measuring the oxygen
demand but BOD (Biological Oxygen Demand) and COD (Chemical
Oxygen Demand) are the most widely accepted methods. The COD
test has many advantages over the BOD method. The COD
test is more accurate and faster than the BOD method. The BOD method requires
a five to seven day incubation period and is more subject to operator
errors. The COD method usually takes under three hours
and is easy to perform by technical and non-technical personnel alike.
Hanna’s COD method also uses a special anti-interference
agent that removes chloride interference. Back to Top
Official Reporting
Method
Chemical Oxygen Demand (COD) is defined as the
amount of specified oxidant that reacts with a sample under controlled
conditions. The quantity of oxygen consumed is expressed in terms of its
oxygen equivalent: mg/L of O2.
The Hanna COD method is based on the well established
Closed Dichromate-Reflux Colorimetric Method and is in accordance with
the two main official courses for chemical analysis in water and wastewater:
“Standard Methods for the Examination of Water and Wastewater”
(20th ed.) Method #5220D and “US Environmental Protection Agency,
Methods and Guidance for Analyses of Water” (2nd ed.) EPA Method
#410.4.
Furthermore, the US Environmental Protection Agency specifies that the
dichromate reflux method is the only method acceptable for reporting purposes.
The advantage in using this method includes highly accurate certifiable
results. Back to Top
The
Hanna COD System
The Hanna closed-reflux colorimetric COD system complies
with the EPA recommended method, and all other recommended applications
that are based on the potassium dichromate method. The individual components
of the system are designed to interface with existing closed-reflux colorimetric
test systems or to supply everything needed to perform simple COD
tests in a few hours.
Our pre-dosed reagents have been developed to minimize the amount of required
testing sample, reagent chemicals and the subsequent waste. Hanna has
taken special precautions to remove any potential interference that may
be caused by the presence of Chloride within the sample solution
As COD levels vary depending on the application and process
measuring points, Hanna offers reagents to cover three separate ranges.
Simply select the most appropriate range for the application. Each box
of 25 vials is supplied with a Reagent Quality Certificate
produced by our quality assurance team. The reagents are traceable to
NIST SRM® 930e.
HI 93754A Low Range 0-150 mg/L
HI 93754B Medium Range 0-1500 mg/L
HI 93754C High Range 0-15000 mg/L
The organic and inorganic compounds present in the water sample are oxidized
under strong chromic acid conditions during a two-hour digestion period
at 150°C in a preheated reactor.
The Hanna reactor C 9800 is a block heater type with
an accurate temperature control system to ensure the digestion temperature
is exactly 150°C ±2°C as required by Standard Methods.
The C 9800 features a user-selectable timing mode (timed
or infinite) and an acoustic alarm to alert the user that the digestion
period is complete. In the timed mode, the reactor automatically switches
off after the digestion has completed. During the digestion period, your
safety is guaranteed using the HI 740217 protective shield.
After digestion, remove the vials from the reactor and place them in the
HI 740216 cooling rack. When the vials are cooled down to about
room temperature, direct COD readings can be obtained
with the C 99 COD analyzer. Using the closed-reflux colorimetric
method has many advantages over conventional methods.
With the Hanna COD solution, no volume correction is
necessary after digestion. The colorimetric method is also advantageous
because you are not required to perform time intensive and reagent consuming
titrations as with other methods.
The C 99 multi-parameter photometer is a high precision
instrument with an advanced optical system. A special microprocessor controlled
tungsten lamp and narrow band optical filters allow extremely accurate
and repeatable readings. This ion specific analyzer is programmed to test
up to 39 parameters including COD. With the C
99, there is no need for complicated programming or installation
of delicate filters. With a touch of a button, select the parameter you
want to test and your photometer is ready for measurement. Back
to Top
|
|