pH & ORP Electrode Selection


Hanna has created a vast assortment of electrodes to meet almost every application. The following listings show electrodes that were designed for specific applications as shown, but each electrode could be used for many different applications with similar requirements.

The following applications may be viewed on this page

Laboratory
Educational
Food Industry
General Electrodes
Replacement Electrodes for Hanna Meters

Laboratory Electrodes


Scroll down to view the following

Emulsion Strong Acid/Alkali Solution
Flasks Semi-solid Products
General Use (Gel) Titration (Platinum ORP)
General Use (Refillable) Vials & Test Tubes
Micro-plate Sampling less than 100µl

 

Laboratory-Emulsion
Combination pH Electrodes

Code HI 1053B HI 1053D HI 1053U HI 1050S
Body glass
Reference Junction single
Cell refillable
Junction Type 3 Ceramic Ø1.2mm
Flow Rate 40-50µl/H
Tip Shape Conic
Dimension 12 x 12mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C -5/+100
Pressure PSI/BAR 7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution
*Suggested Retail Prices (Valid only in USA)

Laboratory-Flasks
Combination pH Electrodes

Code HI 1331B HI 1331D HI 1331U HI 1311S
Body glass
Reference Junction single
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape Sphere
Dimension Ø8.0mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C -5/+100
Pressure PSI/BAR 7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution

Laboratory-General Use refillable
Combination pH Electrodes

Code HI 1230B HI 1230D HI 1230U HI 1210S
Body Ultem®
Reference Junction double
Cell gel
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape Sphere
Dimension Ø7.5mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C 0/+80
Pressure PSI/BAR 21.75/1.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution

Laboratory-General Use
Combination pH Electrodes

Code HI 1131B HI 1131D HI 1131U HI 1111S
Body glass
Reference Junction single
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape Sphere
Dimension Ø9.5mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C -5/+100
Pressure PSI/BAR 7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution

Laboratory-Biotechnology Microplate Sampling of less than 100µL
Combination pH Electrodes

Code HI 1083B HI 1083D HI 1083U
Body glass
Reference Junction single
Cell viscolene
Junction Type free diffusion layer/ open
Tip Shape sphere
Dimension Ø3.0mm
Plug Type BNC DIN US Standard
Cable 1 m, 3mm dia.
Cable Coaxial
Temp range °C 0/+50
Pressure PSI/BAR 1.45/0.1
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution

Laboratory-Strong Acid/Alkali Solution
Combination pH Electrodes

Code HI 1043B HI 1043D HI 1043U HI 1040S
Body glass
Reference Junction double
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Dimension Sphere
Size Ø9.5mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C -5/+100
Pressure PSI/BAR 7.25/0.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution
*

Laboratory-Semi Solid Products
Combination pH Electrodes

Code HI 2031B HI 2031D HI 2031U HI 2020S
Body glass
Reference Junction single
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape conic
Dimension 6 x 10mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C -5/+100
Pressure PSI/BAR 7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution
*

Laboratory-Titration
Combination Platinum ORP Electrodes

Code HI 3131B HI 3131D HI 3131U HI 3111S
Body glass
Reference Junction single
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape rod
Dimension Ø1mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C -5/+100
Pressure PSI/BAR 7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution

Laboratory-Vials & Test Tubes
Combination pH Electrodes

Code HI 1330B HI 1330D HI 1330U HI 1310S
Body glass
Reference Junction single
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape Sphere
Dimension Ø5.0mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C -5/+100
Pressure PSI/BAR 7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution
 

Educational Electrodes


Scroll down to view the following;

Gold ORP
Platinum ORP
Quality Control

Educational-General Use
Combination Gold ORP Electrodes

Code HI 4430B HI 4430D HI 4430U HI 4410S
Body Ultem®
Reference Junction single
Cell gel
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape rod
Dimension Ø1mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C 0/+80
Pressure PSI/BAR 21.75/1.5

Educational-General Use
Combination Platinum ORP Electrodes

Code HI 3230B HI 3230D HI 3230U HI 3210S
Body Ultem®
Reference Junction single
Cell gel
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape rod
Dimension Ø1mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C 0/+80
Pressure PSI/BAR 21.75/1.5

Educational-Quality Control
Combination pH Electrodes

Code HI 1332B HI 1332D HI 1332U HI 1312S
Body Ultem®
Reference Junction double
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape sphere
Dimension Ø7.5mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C 0/+80
Pressure PSI/BAR 7.25/0.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution
 

Food Industry Electrodes


Scroll down to view the following

Food & Wine Processing Food Industry
Sodium Concentration Analysis Meat & Cheese
Very High Humidity Milk & Yogurt

Food Industry-Food & Wine Processing
Combination pH Electrodes

Code FC 220B FC 220D FC 220U
Body glass
Reference Junction single
Cell refillable
Junction Type 3 Ceramic Ø1.2mm
Flow Rate 40-50µl/H
Tip Shape sphere
Dimension Ø9.5mm
Plug Type BNC DIN US Standard
Cable 1 m, 3mm dia.
Cable Coaxial
Temp range °C 0/+100
Pressure PSI/BAR 7.25/0.5
Note: The above electrodes use HI 8071 electrolyte (3.5M KCl+AgCl).

Food Industry-Sodium Concentration Analysis
Combination Sodium Electrodes

Code FC 300B FC 300D FC 300U
Body glass
Reference Junction single
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape sphere
Dimension Ø9.5mm
Plug Type BNC DIN US Standard
Cable 1 m, 3mm dia.
Cable Coaxial
Temp range °C 0/+100
Pressure PSI/BAR 7.25/0.5
Note: The above electrodes use HI 8093 electrolyte (1M KCl+AgCl).

Food Industry-Very High Humidity
AmpHel pH Electrodes

Code FC 911B FC 911D FC 911U
Body Kynar®
Reference Junction double
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape sphere
Dimension Ø7.5mm
Plug Type BNC DIN US Standard
Cable 1 m, 3mm dia.
Cable Biaxial
Temp range °C 0/+80
Pressure PSI/BAR 7.25/0.5
Note: The above electrodes use electrolyte that contains no Silver Chloride to avoid contamination of the sample.
*Suggested Retail Prices (Valid only in USA)
Kynar® is a registered Trademark of "Pennwalt Corporation".

Food Industry-General Use
Combination pH Electrodes

Code FC 100B FC 100D FC 100U
Body Kynar®
Reference Junction double
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape Sphere
Dimension Ø7.5mm.
Plug Type BNC DIN US Standard
Cable 1 m, 3mm dia.
Cable Coaxial
Temp range °C 0/+80
Pressure PSI/BAR 7.25/0.5
Note: The above electrodes use electrolyte that contains no Silver Chloride to avoid contamination of the sample.

Food Industry-Meat & Cheese
Combination pH Electrodes

Code FC 200B FC 200D FC 200U FC 200S
Body Kynar®
Reference Junction single
Cell viscolene
Junction Type free diffusion layer/ open
Tip Shape conic
Dimension 6 x 10mm
Plug Type BNC DIN US Standard Screw Cap
Cable 1 m, 3mm dia. NA
Cable Coaxial NA
Temp range °C 0/+50
Pressure PSI/BAR 1.45/0.1
Note: viscolene contains 3.5M KCl+AgCl

Food Industry-Milk, Yogurt
Combination pH Electrodes

Code FC 210B FC 210D FC 210U
Body glass
Reference Junction double
Cell viscolene
Junction Type free diffusion layer/ open
Tip Shape conic
Dimension 12 x 12mm
Plug Type BNC DIN US Standard
Cable 1 m, 3mm dia.
Cable Coaxial
Temp range °C 0/+50
Pressure PSI/BAR 1.45/0.1
Note: The above electrodes use electrolyte that contains no Silver Chloride to avoid contamination of the sample.

General Electrodes


Scroll down to view the following

pH Electrode (Half Cell) Combination pH Electrode w/ Flat Tip (Half Cell)
Ag/AgCl Reference Electrode (Half Cell) Calomel Reference Electrode

 

Half Cell Electrodes
Single pH Electrode-General Use

Code HI 2110B
Body glass
Tip Shape sphere
Dimension Ø9.5mm
Plug Type BNC
Cable 1 m, 3mm dia.
Cable Coaxial
Temp range °C -5/+100
Pressure PSI/BAR 43.5/3.0

Half Cell Electrodes
Single Ag/AgCl Reference Electrode-General Use With Wide Temp Range

Code HI 5311
Body glass
Reference Junction double
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape NA
Dimension NA
Plug Type Banana
Cable 4mm
Cable single
Temp range °C -5/+100
Pressure PSI/BAR 7.35/0.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution

Special pH Electrodes-Surface Measurement
Combination pH Electrode With Flat Tip

Code HI 1413B
Body glass
Reference Junction single
Cell viscolene
Junction Type free diffusion layer/ open
Tip Shape Flat
Dimension Ø10mm
Plug Type BNC
Cable 1 m, 3mm dia.
Cable Coaxial
Temp range °C -5/+50
Pressure PSI/BAR 1.45/0.1

Half Cell Electrodes
Single Calomel Reference Electrode-General Use W/Constant Temp Range

Code HI 5412
Body glass
Reference Junction single
Cell refillable
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape NA
Dimension NA
Plug Type Banana
Cable 4mm
Cable single
Temp range °C -5/+60
Pressure PSI/BAR 7.35/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl solution



Replacement Electrodes for Hanna Meters


Scroll down to view the following;

Use with HI 3050N & HI 9214 Use with Piccolo 2
Use with Checker® Use with Piccolo +
Use with Piccolo

Special pH Electrodes-Use With HI 3050N & HI 9214
Combination pH Electrode With Built-in Temp Sensor

Code HI 1217D HI 1217S
Body Ultem®
Reference Junction single
Cell Gel
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape sphere
Dimension Ø5.0mm
Plug Type DIN Screw Cap
Cable 1 m, 3mm dia. NA
Cable 5W NA
Temp range °C 0/+80
Pressure PSI/BAR 7.25/0.5

Special pH Electrodes-Use With Checker
Combination pH Electrode

Code HI 1270
Body Polypro
Reference Junction single
Cell viscolene
Junction Type free diffusion layer/ open
Tip Shape sphere
Dimension Ø3.0mm
Plug Type screw
Temp range °C 0/+50
Pressure PSI/BAR 1.45/0.1

Special pH Electrodes-For use with the Piccolo Line
Combination Amplified pH Electrode With Temperature Sensor

Code HI 1280 HI 1290 HI 1295
Application Piccolo Piccolo 2 Piccolo +
Body Polypro
Reference Junction single
Cell gel
Junction Type 1 Ceramic Ø1.2mm
Flow Rate 15-20µl/H
Tip Shape sphere
Dimension Ø5.0mm
Plug Type multi-pin
Temp range °C 0/+70
Pressure PSI/BAR 1.45/0.1

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664