pH & ORP Electrode Selection
Hanna has created a vast assortment of electrodes to meet almost every application. The
following listings show electrodes that were designed for specific applications as shown,
but each electrode could be used for many different applications with similar
requirements.
The following applications may be viewed on this page
Laboratory
Educational
Food Industry
General Electrodes
Replacement Electrodes for Hanna Meters
Laboratory Electrodes
Scroll down to view the following
Laboratory-Emulsion
Combination pH Electrodes
Code
HI 1053B
HI 1053D
HI 1053U
HI 1050S
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
3 Ceramic Ø1.2mm
Flow Rate
40-50µl/H
Tip
Shape
Conic
Dimension
12 x 12mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
-5/+100
Pressure PSI/BAR
7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M
KCl/AgCl solution
*Suggested Retail Prices (Valid only in
USA)
Laboratory-Flasks
Combination pH Electrodes
Code
HI 1331B
HI 1331D
HI 1331U
HI 1311S
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
Sphere
Dimension
Ø8.0mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
-5/+100
Pressure PSI/BAR
7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl
solution
Laboratory-General Use
refillable
Combination pH Electrodes
Code
HI 1230B
HI 1230D
HI 1230U
HI 1210S
Body
Ultem®
Reference
Junction
double
Cell
gel
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
Sphere
Dimension
Ø7.5mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
0/+80
Pressure PSI/BAR
21.75/1.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution
Laboratory-Gen eral Use
Combination pH Electrodes
Code
HI 1131B
HI 1131D
HI 1131U
HI 1111S
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
Sphere
Dimension
Ø9.5mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
-5/+100
Pressure PSI/BAR
7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl
solution
Laboratory-Biotechnology Microplate Sampling
of less than 100µL
Combination pH Electrodes
Code
HI 1083B
HI 1083D
HI 1083U
Body
glass
Reference
Junction
single
Cell
viscolene
Junction
Type
free diffusion layer/ open
Tip
Shape
sphere
Dimension
Ø3.0mm
Plug
Type
BNC
DIN
US Standard
Cable
1 m, 3mm dia.
Cable
Coaxial
Temp range °C
0/+50
Pressure PSI/BAR
1.45/0.1
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl
solution
Laboratory-Strong Acid/Alkali Solution
Combination pH Electrodes
Code
HI 1043B
HI 1043D
HI 1043U
HI 1040S
Body
glass
Reference
Junction
double
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Dimension
Sphere
Size
Ø9.5mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
-5/+100
Pressure PSI/BAR
7.25/0.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution
*
Laboratory-Semi Solid Products
Combination pH Electrodes
Code
HI 2031B
HI 2031D
HI 2031U
HI 2020S
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
conic
Dimension
6 x 10mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
-5/+100
Pressure PSI/BAR
7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl
solution
*
Laboratory-Titration
Combination Platinum ORP Electrodes
Code
HI 3131B
HI 3131D
HI 3131U
HI 3111S
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
rod
Dimension
Ø1mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
-5/+100
Pressure PSI/BAR
7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl
solution
Laboratory-Vials & Test Tubes
Combination pH Electrodes
Code
HI 1330B
HI 1330D
HI 1330U
HI 1310S
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
Sphere
Dimension
Ø5.0mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
-5/+100
Pressure PSI/BAR
7.25/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl
solution
Educational Electrodes
Scroll down to view the following;
Educational-General Use
Combination Gold ORP Electrodes
Code
HI 4430B
HI 4430D
HI 4430U
HI 4410S
Body
Ultem®
Reference
Junction
single
Cell
gel
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
rod
Dimension
Ø1mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
0/+80
Pressure PSI/BAR
21.75/1.5
Educational-General Use
Combination Platinum ORP Electrodes
Code
HI 3230B
HI 3230D
HI 3230U
HI 3210S
Body
Ultem®
Reference
Junction
single
Cell
gel
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
rod
Dimension
Ø1mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
0/+80
Pressure PSI/BAR
21.75/1.5
Educational-Quality Control
Combination pH Electrodes
Code
HI 1332B
HI 1332D
HI 1332U
HI 1312S
Body
Ultem®
Reference
Junction
double
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
sphere
Dimension
Ø7.5mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
0/+80
Pressure PSI/BAR
7.25/0.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution
Food Industry Electrodes
Scroll down to view the following
Food Industry-Food & Wine Processing
Combination pH Electrodes
Code
FC 220B
FC 220D
FC 220U
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
3 Ceramic Ø1.2mm
Flow Rate
40-50µl/H
Tip
Shape
sphere
Dimension
Ø9.5mm
Plug
Type
BNC
DIN
US Standard
Cable
1 m, 3mm dia.
Cable
Coaxial
Temp range °C
0/+100
Pressure PSI/BAR
7.25/0.5
Note: The above electrodes use HI 8071 electrolyte (3.5M KCl+AgCl).
Food Industry-Sodium Concentration Analysis
Combination Sodium Electrodes
Code
FC 300B
FC 300D
FC 300U
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
sphere
Dimension
Ø9.5mm
Plug
Type
BNC
DIN
US Standard
Cable
1 m, 3mm dia.
Cable
Coaxial
Temp range °C
0/+100
Pressure PSI/BAR
7.25/0.5
Note: The above electrodes use HI 8093 electrolyte (1M KCl+AgCl).
Food Industry-Very High Humidity
AmpHel pH Electrodes
Code
FC 911B
FC 911D
FC 911U
Body
Kynar®
Reference
Junction
double
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
sphere
Dimension
Ø7.5mm
Plug
Type
BNC
DIN
US Standard
Cable
1 m, 3mm dia.
Cable
Biaxial
Temp range °C
0/+80
Pressure PSI/BAR
7.25/0.5
Note: The above electrodes use electrolyte that contains no Silver
Chloride to avoid contamination of the sample.
*Suggested Retail Prices (Valid only in USA)
Kynar® is a registered Trademark of "Pennwalt Corporation".
Food Industry-General Use
Combination pH Electrodes
Code
FC 100B
FC 100D
FC 100U
Body
Kynar®
Reference
Junction
double
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
Sphere
Dimension
Ø7.5mm.
Plug
Type
BNC
DIN
US Standard
Cable
1 m, 3mm dia.
Cable
Coaxial
Temp range °C
0/+80
Pressure PSI/BAR
7.25/0.5
Note: The above electrodes use electrolyte that contains no Silver
Chloride to avoid contamination of the sample.
Food Industry-Meat & Cheese
Combination pH Electrodes
Code
FC 200B
FC 200D
FC 200U
FC 200S
Body
Kynar®
Reference
Junction
single
Cell
viscolene
Junction
Type
free diffusion layer/ open
Tip
Shape
conic
Dimension
6 x 10mm
Plug
Type
BNC
DIN
US Standard
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
Coaxial
NA
Temp range °C
0/+50
Pressure PSI/BAR
1.45/0.1
Note: viscolene contains 3.5M KCl+AgCl
Food Industry-Milk, Yogurt
Combination pH Electrodes
Code
FC 210B
FC 210D
FC 210U
Body
glass
Reference
Junction
double
Cell
viscolene
Junction
Type
free diffusion layer/ open
Tip
Shape
conic
Dimension
12 x 12mm
Plug
Type
BNC
DIN
US Standard
Cable
1 m, 3mm dia.
Cable
Coaxial
Temp range °C
0/+50
Pressure PSI/BAR
1.45/0.1
Note: The above electrodes use electrolyte that contains no Silver
Chloride to avoid contamination of the sample.
General Electrodes
Scroll down to view the following
Half Cell Electrodes
Single pH Electrode-General Use
Code
HI 2110B
Body
glass
Tip
Shape
sphere
Dimension
Ø9.5mm
Plug
Type
BNC
Cable
1 m, 3mm dia.
Cable
Coaxial
Temp range °C
-5/+100
Pressure PSI/BAR
43.5/3.0
Half Cell Electrodes
Single Ag/AgCl Reference Electrode -General Use With Wide Temp Range
Code
HI 5311
Body
glass
Reference
Junction
double
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
NA
Dimension
NA
Plug
Type
Banana
Cable
4mm
Cable
single
Temp range °C
-5/+100
Pressure PSI/BAR
7.35/0.5
Note: Double junction refillable electrodes use HI 7082 3.5M KCl solution
Special pH Electrodes-Surface Measurement
Combination pH Electrode With Flat Tip
Code
HI 1413B
Body
glass
Reference
Junction
single
Cell
viscolene
Junction
Type
free diffusion layer/ open
Tip
Shape
Flat
Dimension
Ø10mm
Plug
Type
BNC
Cable
1 m, 3mm dia.
Cable
Coaxial
Temp range °C
-5/+50
Pressure PSI/BAR
1.45/0.1
Half Cell Electrodes
Single Calomel Reference Electrode -General Use W/Constant Temp Range
Code
HI 5412
Body
glass
Reference
Junction
single
Cell
refillable
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
NA
Dimension
NA
Plug
Type
Banana
Cable
4mm
Cable
single
Temp range °C
-5/+60
Pressure PSI/BAR
7.35/0.5
Note: Single junction refillable electrodes use HI 7071 3.5M KCl/AgCl
solution
Replacement Electrodes for Hanna Meters
Scroll down to view the following;
Special pH Electrodes-Use With HI 3050N
& HI 9214
Combination pH Electrode With Built-in Temp Sensor
Code
HI 1217D
HI 1217S
Body
Ultem®
Reference
Junction
single
Cell
Gel
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
sphere
Dimension
Ø5.0mm
Plug
Type
DIN
Screw Cap
Cable
1 m, 3mm dia.
NA
Cable
5W
NA
Temp range °C
0/+80
Pressure PSI/BAR
7.25/0.5
Special pH Electrodes-Use With Checker
Combination pH Electrode
Code
HI 1270
Body
Polypro
Reference
Junction
single
Cell
viscolene
Junction
Type
free diffusion layer/ open
Tip
Shape
sphere
Dimension
Ø3.0mm
Plug
Type
screw
Temp range °C
0/+50
Pressure PSI/BAR
1.45/0.1
Special pH Electrodes-For use with the
Piccolo Line
Combination Amplified pH Electrode With Temperature Sensor
Code
HI 1280
HI 1290
HI 1295
Application
Piccolo
Piccolo 2
Piccolo +
Body
Polypro
Reference
Junction
single
Cell
gel
Junction
Type
1 Ceramic Ø1.2mm
Flow Rate
15-20µl/H
Tip
Shape
sphere
Dimension
Ø5.0mm
Plug
Type
multi-pin
Temp range °C
0/+70
Pressure PSI/BAR
1.45/0.1