The pH  electrodes listed below are for use with Models 350, 370, 3305, 3310, 3320, and 3330.  All electrodes should be used at atmospheric pressure only. All electrodes (except *) are combination type with integral reference, operate over the range of 0 - 14pH, have an overall length of 120mm and are fitted with a 1 meter cable as standard. Alternative cable lengths are available on request. 

    Temp. Range Diameter Application
924 001 General purpose, epoxy bodied 0 - 60șC 12mm Liquids
924 002 Spear type, 12mm stem, glass bodied 0 - 80șC 12mm Slurries
924 003 Redox - platinum, glass bodied 0 - 80șC 12mm Liquids
924 004 Micro 40mm stem, glass bodied 0 - 80șC 4.5mm (Stem) Liquids
924 005 General purpose, glass bodied 0 - 80șC 12mm Liquids
924 006 Flat head, glass bodied 0 - 80șC 12mm Surfaces
924 007 Semi-micro, 90mm stem, glass bodied 0 - 80șC 4.5mm (Stem) Liquids
924 008 Long reach micro, 150mm stem, glass bodied 0 - 80șC 7.5mm (Stem) Liquids
924 010 Spear type, 40mm stem, glass bodied 0 - 80șC 6mm (Stem) Semi-solids
924 011 Spear type, 25mm stem, glass bodied 0 - 80șC 4mm (Stem) Semi-solids
924 029 Low Conductivity Waters, plastic bodied 0 - 50șC 12mm Liquids
924 030 Tris buffer, 90mm stem, glass bodied 0 - 50șC 6mm (Stem) Biological fluids
924 047 3 in 1 electrode, epoxy bodied ** 0 - 80șC 12mm Liquids
924 015 pH electrode, glass bodied * 0 - 80șC 12mm Liquids
924 016 Calomel reference, SJ, glass bodied 0 - 50șC 12mm Liquids
924 017 Ag/AgCl reference, DJ, glass bodied 0 - 50șC 12mm Liquids
924 036 Ag/AgCl reference 0 - 100șC 12mm Liquids

** Integral Temperature Measurement.


Conductivity Cells

The following Conductivity Cells are for use with Models 4310, 4320 and 4330.

027 013 Conductivity Cell with ATC K=1
027 113 Conductivity Cell with ATC K=0.1
027 114 Conductivity Cell with ATC K=1 (flow through)
027 211 Conductivity Cell with ATC K=0.1 (Epoxy)
027 212 Conductivity Cell with ATC (K=1) (Epoxy)
027 213 Conductivity Cell with ATC (K=10)

pH Buffers

025 113 pH4 (100ml) capsule 10 off
025 114 pH7 (100ml) capsule 10 off
025 115 pH9 (100ml) capsule 10 off
025 116 pH10 (100ml) capsule 10 off
025 037 pH4 (500ml) red
025 038 pH7 (500ml) yellow
025 039 pH10 (500ml) blue
025 162 pH9.22 (500ml)
025 163 pH2 (500ml)

Conductivity Calibration Standards

025 138

1413”S standard (500ml)

025 156

12.88mS standard (500ml)

025 164

84”S standard (500ml)

025 139

10”S standard (500ml)

025 165

1382ppm TDS standard (500ml)


Miscellaneous accessories

025 160 3M KCl electrode fill solution
025 161 Electrode cleaning solution
025 157 Redox standard (200mV) (500ml)
025 158 Redox standard (300mV) (500ml)
025 159 Redox standard (465mV) (500ml)
021 030 UK 230V power supply
021 031 European 230V power supply
021 032 US 115V power supply
021 033 230V leaded power supply
544 008 Dust cover
903 200 Swing Arm electrode holder
543 001 40 column printer
542 009 Interface cable kit
552 050 BOD Kit
983 030 Zero powder
522 019 Membrane Kit and KCl
522 023 DO2 probe
027 234 ATC probe for use with Model 3305
027 232 ATC probe for use with Models 3310, 3320 and 4330

 

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117