Low Cost Single Function Calibrators
More Calibrators
LC100
Precision Loop Calibrator |
|
| COMMON
FEATURES |
 |
Very high
accuracy - ±0.015% of reading |
 |
Very high
resolution - 0.001 mA |
 |
% Error
function - eliminates manual error calculation |
 |
Extended
adjustment range—digital knob and user-selectable decade
output allow both large and incremental (0.001 mA step) output
changes |
 |
Reads 0 to
28.000 VDC |
 |
Built-in 250
Ohm resistor facilitates calibration of Hart™ devices |
 |
Remote
calibration through Automatic Step and Ramp functions |
 |
Loop
power measurement capability |
 |
Simulates,
powers, and measures two-wire transmitters |
 |
Five
preset outputs (4, 8, 12, 16, 20 mA) |
 |
Fuseless
input protection up to 250 VAC |
|

|
The Martel Electronics LC-100
Precision Loop Calibrator provides significantly extended performance
when compared to any competitive calibrator. With an accuracy of 0.015%
of reading, with 0.001 mA resolution, the LC-100 has the highest
accuracy in its class.
Unique features, such as a “% Error” function, which eliminates
manual error calculation and allows the display of the actual versus
ideal error at any calibration point, put the LC-100 way beyond similar
instruments.
The Martel LC-100 can simulate, power, and measure two-wire
transmitters. With automatic Step and Ramp functions, the LC-100 enables
remote calibration of 4-20 mA devices. |
Tuff-Tools
T100
Single Function Voltage, Frequency & Milliamp Calibrators Made With
the Technician in Mind |
|
| COMMON
FEATURES |
 |
High
Accuracy/Source and Read Capability membrane keypad with simple
controls |
 |
Rugged, Dust
Tight, Water Resistant Case |
 |
Easy to Read
Super-Twist LCD |
 |
Intuitive
Controls make operation Easy even for infrequent users |
 |
Powered by a
common 9 Volt battery |
|

|
The Tuff-Tools line of
calibrators is designed to give the technician laboratory grade accuracy
in a family of rugged, easy to use instruments.
The Tuff-Tools family consists of 3 Process Signal calibrators (mA,
Volts, Frequency), 2 Temperature calibrators (T/C, RTD) and a Pressure
calibrator available in several ranges (200" H 2 O, 30 PSI, 100 PSI).
Operation of these calibrators is made easy through the use of a sealed
membrane keypad with simple controls. The outputs are set through the
use of step and ramp keys which allows both large and small output
changes to be made with ease.
Each Unit Includes: Test leads, carrying case, 9V battery, NIST
Certificate, and instruction manual. |
| Thermocouple
- T120 |
| Range: |
0.00
to 24.00 mA
25.0% to 125.0% |
| Operating
Modes: |
Source,
Simulate, Read,
Read/Power |
| Accuracy¹
: |
±
0.025% FS ± 1 LSD |
| Operating
Temp.: |
0
to 50°C |
| Storage
Temp.: |
-20
to 60°C |
| Temperature
Stability²: |
.01%
F.S./°C |
| Loop
Power: |
24V
DC |
| Step
Size: |
4
mA (0, 4, 8, 12, 16, 20
and 24) |
| Scroll
Size: |
.01
mA |
| Load
Capacity: |
1000
Ohms Minimum |
| Weight: |
12
oz. |
| Size: |
1.43"
x 3.15" x 5.7" |
Note
1: 18°C to 28°C
Note 2: 0 to 18°C and 28°C to 50°C |
|
View
PDF file (96.8KB)
MS-420
Mini-Source Portable Calibrator |
|
| TYPICAL
APPLICATIONS |
 |
Chart
Recorder |
 |
Panel
Meter |
 |
Data
Acquisition |
 |
Other
Process Instruments |
|

|
This multi purpose
process loop tool offers high accuracy in an ultra-small, rugged
package. The MiniSource Process Calibrator has the ability to
calibrate or troubleshoot any 4 mA to 20 mA loop device.
A single pushbutton allows the user to select one of the 5
current outputs (4, 8, 12, 16 or 20 mA) which can drive up to
300 ohms, or act as a 2-wire simulator with an external loop
power supply of up to 30 VDC.
Each Unit Includes: 9 V battery, NIST Certificate, and
instruction manual. |
| General
Specifications: |
| Output: |
5
current steps
(4, 8, 12, 16, 20 mA) |
| Accuracy: |
±0.075
of full scale |
Voltage
Compliance: |
Source: Internal 9 volt battery
Simulate: External supply - up to 30 VDC |
Temperature
Stability: |
100 ppm/°C |
| Power
Supply: |
9
volt alkaline battery |
| Battery
Life: |
50
hours @ 4 mA out |
Temperature
Range: |
Operating: 0° to 50°C
Storage: –25° to 60°C
Output Terminations: Two alligator clips on 8"
leads. |
| Size: |
3.8"
x 2.4" x 1.0" |
|
|
IVC-222HPII
Voltage/Current Calibrator |
|
| COMMON
FEATURES |
 |
Remarkable
0.015% of reading accuracy |
 |
Four ranges;
200 mV, 2 V, 20 V, and 24 mA |
 |
Intuitive, easy
to use controls |
 |
RS-232
interface - can be computer controlled |
 |
Built-in 24
volt supply can drive 4 to 20 mA loops over 1000 ohms |
 |
Rugged,
lightweight, hand-held case |
|

|
The all new IVC-222HPII is a
gener-al purpose current and voltage source that can be used in
engineering, manu-facturing; test and process control applications. It
combines the latest digital and analog circuitry to achieve it’s rated
specifications in a small, reliable package.
This unit has the capability to store and recall up to two values in the
set-points provided by the SP1 and SP2 keys.
The IVC-222HPII has a RS-232 port which can be accessed via a custom
cable available from Martel allowing the unit to be computer controlled
for automated testing.
Each Unit Includes: Test leads, carrying case, 9V battery, NIST
Certificate, and instruction manual. |
| General
Specifications: |
| |
Voltage
Output |
mA
Output |
| Output
Range: |
200
mV 2 V 20 V |
24
mA |
| Resolution: |
0.01
mV 0.1 mV 1 mV |
mA |
| Accuracy
18°C to 28°C: |
±0.015%
of Reading ±2 count |
|
| Temperature
Stability: |
0
to 18°C
28 to 50°C |
|
| Load
Capability: |
±1
mA for rated accuracy |
1000
ohms |
| Capacitive
Load: |
No
limitations |
N/A |
| Output
Protection: |
Current
limited Internal Resett |
|
| Power: |
9V
Alkaline battery or optional NiCd |
|
| Case
Dimensions: |
1.43"
x 3.15" x 5.7" |
|
| Weight: |
12
oz. |
|
| Size: |
1.43"
x 3.15" x 5.7" |
|
|
| Range |
Min. |
Max. |
Accuracy
(% of reading ± counts) |
| mV |
0.00 |
200.00 |
0.015%
± 2 |
| V |
0.0000
0.000 |
2.0000
20.000 |
0.015%
± 2
0.015% ± 2 |
| mA |
0.000 |
24.000 |
0.015%
± 2 |
|
| Microprocessor Calibrator
Thermometer 433201 |
More_Info |
 |
Source and
Measure 8 thermocouple type devices J, K, T, E, C, R, S and N
|
| Type J or K Calibrator
Thermometer 42311 |
More_Info |
 |
Quick and easy
sourcing and measurement
|
| Unical Precision RTD
Calibrator 423412 |
More_Info |
 |
Calibrates 12
Thermocouples or 9 RTDs
|
| Unical Precision T/C
Calibrator 423408 |
More_Info |
 |
Calibrates 12
Thermocouples or 9 RTDs
|
 |
The new Fluke
705 Loop Calibrator is a cost-effective, integrated solution for
calibration, repair and maintenance of current loops
|
| Fluke 710 Series Pressure
Calibrators |
More_Info |
 |
The Fluke 710
Series Process Calibrators offer a clear new choice in single-function
calibrators. These hand-held calibrators deliver outstanding
performance, durability and reliability
|
 |
Measure
temperature from RTD output
|
 |
Measure
temperature from TC output
|
 |
Measure loop
current (0-20 mA, 4-20 mA) signals with 0.025% accuracy and 1 mA
resolution
|
| Fluke 787 ProcessMeter Loop
Calibrator |
More_Info |
 |
Fluke combined
the DMM you trust with the loop calibrator you need.
|
|