Amprobe Recorders       Digital                              Chart

PRODUCT FEATURE:
LAS-800 Single Phase AC Volts Spike/Surge/Sag
Strip Chart Recorder

Amprobe MODEL LAS-800
FEATURES

 

  • Solid state circuit design
  • Easy to use, affordable
  • All 3 disturbances appear on the same chart
  • Low battery indication
  • Response time to 350 nano Seconds
  • User adjustable thresholds for all 3 variables

Power line disturbances can cause modern electronic equipment, such as computers, to malfunction. Common types of power line disturbances are high frequency impulses (spikes), voltage dips (sags), and voltage increases (surges). Even though monitoring for these disturbances can be costly and time- consuming, it is important to monitor the line to determine if protection is necessary, and if so, the type.

The AMPROBE LAS-800 strip chart recorder offers an easy to use, affordable solution to monitoring. Through the use of advanced solid state circuit design, the LAS-800 can monitor the power line for all three types of disturbances and display the results on a strip chart. The AMPROBE LAS-800 can easily be moved from site to site because of its rugged design and small size.

Ranges: 0-220/440/880 volts, full scale, 50 or 60 Hz Nominal voltage ranges are average responding, calibrated in terms of RMS Spike-Sag-Surge voltage ranges are peak sensing, but scaled in terms of RMS

Ranges: 0-220/440/880 volts, full scale, 50 or 60 Hz
Nominal voltage ranges are average responding, calibrated in terms of RMS
Spike-Sag-Surge voltage ranges are peak sensing, but scaled in terms of RMS

Accuracy: Nominal voltage ranges ±3% Full Scale Sag & Surge modes, ±3% Full Scale,
±2% of reading based on sinusoidal waveforms.
NOTE: sag & surge response time is 1/2 cycle of 50 or 60 Hz sinewaves
Spike mode, ±3% Full Scale, ±10% of reading.
Spike accuracy is specified for a rectangular pulse whose rise time is greater than
35 nanoseconds and whose sum of rise time plus peak duration is at least
350 nanoseconds. Accuracy diminishes for narrower spikes.

Input Impedance: 220 volt range - 387 Kohms (±1%)/15pf)
440 volt range - 784K ohms (±1%)/15pf)
880 volt range - 1580K ohms (±1%)/15pf)

Threshold Adjustment Range: Surge & Spike are adjustable from 0% to 100% of full Scale. Sag is
adjustable from 0% to 50% of Full Scale.

Battery Backup (for memory only): Two 9V alkaline batteries Model MN1604

Line Power: 120VAC, 60 Hz, 9 Watts (50 Hz Available)

Operating Temperature Range: 32°F to 122°F (0°C to 50°C)

Chart Speed: 12"/Hour

Line Fuse: 0.2 amp, 250V Model 3AG-313

Input Overload: 50% Full Scale for 1 minute

Size: 7 1/2" x 5 1/4" x 9 1/4" (19.05cm x 13.34cm x 23.50 cm)

Weight: 5 Lbs. (2.27Kg)

Supplied with one red and one black test lead, one line power cord and one 30 foot roll of model 800S chart paper.

Not available with take-up reel capability, nor with one inch per hour chart speed.
ACCESSORIES AND REPLACEMENTS
9V alkaline battery MN1604
0.2 amp 250 volt fuse 3AG-313
Strip Chart (30 feet) 800S
"Power cord (Gray), 2 conductor (for oler recorders)" PC-3
Safety Voltage Test Leads VL-74
Instruction Book P/N 91175

(67K) Amprobe Catalog


Amprobe Model DM-I TM Recorder




Features

The AMPROBE DigiMaticTM model DM-I is a portable 3-phase micro- computer-based chartless recorder. It incorporates 4 LED digits which recall and display more than 41 days of data from 44 separate functions: present reading, peak, "Relative" time of peak, minimum reading, "Relative" time of minimum, maximum reading, "Relative" time of maximum, average reading, sweep of present readings, power failure, and total time.

"PEAK" indicates the highest current surge (80 msec. min) measured.
"MAX" indicates the largest average maximum voltage or current measured over 6 second intervals.


True RMS sensing
Built-in circuit will retain memory in case of power loss.
"Confidence Test" - at start of any recording run, all segments of all LED digits and all LED lamps will be illuminated for a few seconds.
Start switch has a safety feature which prevents loss of previously recorded data.
Monitors 9 readings sequentially in "record" mode "sweep" position.
Continuously monitors one of six variables at the turn of a switch in "present reading" mode.
Measures and records data from 6 different inputs in the "record" mode.
Ranges: 0-750 volts AC, auto-ranging 0-1000 amps AC, auto-ranging

Specifications

Ranges: 0-750 volts AC, auto-ranging
0-1000 amps AC, auto-ranging

Resolution: 0.1 (0-100.0)
1.0 (100-999.9)

Accuracy: Volts ±1.0% of Rdg ±2 LSD
Amps ±1.5% of Rdg ±2 LSD
Peak ±2.0% of Rdg ±5 LSD

Based on measurement frequency between 40-400 Hz.

Response Time: 6 sec. maximum in record mode
2 sec. in present reading mode
80 msec. in peak mode

Power: Switch selection of 120V/60Hz or 240/50 Hz
Battery back-up to retain memory in the event of power failure, requires 4 "C" type
zinc carbon or alkaline batteries.

Battery life: Fresh carbon cell batteries will last 96 hours; fresh alkaline batteries will last 144 hours.

Recording Time: 999.9 hours

Operating Temperature: 32° to 120°F (0° to 49°C), up to 85% RH

Sensing: True RMS on current and voltage functions
Peak sensing on peak current functions

Case Breakdown: 2500 volts

Overvoltage Protection: 100% or 1500 volts

Digit Size: 7/16" (1.1 cm)

Size: 13 1/2" L x 5 1/2" H x 10"W (34.3cm x 14cm x 25.4cm)

Weight: 7 1/2" (3.4Kg)

Accessories 
(67K) Amprobe Catalog

0.2 amp Slo-Bio fuse 3AG-313
Voltage leads (set of 4) DVL-1
1.5V Alkaline Battery (pkg. Of 2) MN1400
Instruction Book P/N 92375

Model

DigiMaticTM model DM-I


Amprobe Model DM-II TM Data Logger / Recorder



Features

You may not have to climb a mountain to get the job done, but whether you work indoors or outdoors, the DM-IITM gives you peak performance in any environment. The DM-IITM Data Logger/Recorder is the next step in chartless recording.

The New DigiMaticTM II is an AC Data Logger/Recorder in a stand alone configuration. Data can be viewed in the field via its large self-contained backlit LCD display or can be accessed and downloaded through a personal computer.

• Three DM-II™ versions: DM-II™ Standard Unit; DM-II™ CE CE Approved;
DM-II™ NA UL Approved
• Single or three phase capable
• AC voltage 5 to 600 volts
• AC current 1 to 1000 amperes
• 3 Channels for voltage measurements and 4 channels for current measurements
• Graphic display 160x160 pixel
• All readings are True RMS
• Power Measurements include: 1- Watts 3- VA
2- Vars 4- PF(Power Factor)
• Energy Measurements include: 1- KW-HR’s
2-Demand or Non Demand
• User selectable recording rates.
• DM-II View™ software allows downloading data to a personal computer running Windows™ 3.11/95 and NT environment.
Computer requirements: 486 - 50Mhz, 8Megs of RAM (16Meg recommended).
• Line Operated (120V/60Hz & 240V/50Hz)
• Battery backup protects memory if a power failure occurs and allows recording session to continue.
• Auto Ranging
• Real time clock
• Multi Languages built in: 1- English 2- German 5- French 3- Spanish 4- Italian
• Rugged ABS plastic case with a weather resistant design
• Made in USA

Specifications

Inputs: Voltage - Three voltage channels with common (V1, V2, V3 and COM). The test leads are flexible straight sheath banana plugs on each end, rated 1000Vrms and a length of 6 feet (set of four supplied). The alligator clips have a 1 inch jaw opening and are rated at 10A max (set of four supplied).

Current - Four current channels (I1, I2, I3, I4) DM-CT: 1 to 1000A ±1% of reading (four supplied)
ACF3000: 30A to 300A ±1% of full scale 300A to 3000A ±1% of full scale

Note: The ACF-3000 is an optional accessory. A total of three would be required for a 3Ø measurement. Adaptor ACF-5 is required.

Ranges: AC Voltage measurements (True RMS) 5 to 600 Vrms.
AC Current measurements (True RMS) 1 to 1000 Arms with four supplied DM-CT’s

Accuracy: Voltage measurements ± 1% of reading +3 LSD's
Current measurements ± 1% of reading +3 LSD's

Voltage and Current Measurement Selections: True RMS voltage and current, RMS max, RMS min, RMS avg, Peak max



Power measurement Capabilities: Real Power P (watts), Apparent Volt-amperes S (VA), Reactive Volt amperes Q (VAR), True Power Factor (tPF)

Energy Measurement Capabilities: Kilowatt Hours (KWH), Demand (KW)

Programmable Thresholds: User selectable high/low limits for RMS voltage and current.

Recording Modes/Rates/Intervals: User selectable normal and loop (wrap around) recording modes. User
selectable recording rates of 1 sec, 5 sec, 15 sec, 30 sec, 1 min, 5 min, 15 min, 30 min. Recording intervals for Demand (KW) are 15 min and 30 min.

Memory: Total of 600K RAM memory. The recording session length depends on the recording rate, the number of selections, recording mode, and recording interval. The memory has a lithium battery backup to preserve its contents in the event of the absence of AC power and batteries.

Real Time Clock: The user programmable real-time clock is displayed in 12/24 hour formats and HH:MM:SS Day month year, daylight savings option, accuracy ±1 min per month.

System Configuration: Total of four presorted setup configurations for 1Ø and 3Ø systems: 1Ø 2W, 1Ø 3W, 3Ø 3W Straight Delta, and 3Ø 4W Wye.
Note: Any or all parameters of a phase configuration can be recorded.

PC Interface: Optically isolated RS-232 serial interface. DM-II View™ software for display, analysis, and report generation. User selectable baud rates of 9600, 19200 and 38400 baud.

Power Requirements: AC line voltage with battery backup operation. The ON/OFF dual color LED indicates the unit’s power source - Green indicates AC line power and Red for battery backup power.

Designed to Meet: UL3111-1, CE (LVD/EMC/EMI)

Sample Rate: 130µ sec. (7.68 KHz, 128 samples per cycle per channel, total of 8 channels).

Case: Material: Injection molded flame retardant ABS911, rugged, water-resistant, and corrosion proof.
Case dimensions: 17.5” x 11.6” x 7.5”
Weight: 16 lbs. (7.3 kgs.) includes batteries, 4 CTs, voltage leads and alligator clips.
Pressure relief valve: Important - Be sure the knob located next to the handle is open when
encountering atmospheric changes.

Battery: 6 alkaline “D” cells (not supplied)

Battery Life: 21 hours continuous with backlight OFF, 1 sec. recording rate, normal recording mode, all parameters selected for 3Ø 4W WYE configuration

Operation Temperature Range: 32 to 122°F (0-50°C) RH<85%

Storage Temperature Range: -4 to 140 °F (-2 to 60°C) RH<90%



SYSTEM REQUIREMENTS FOR DM-II VIEW™ USER INTERFACE
Windows™ 3.11/Windows™ 95 and Windows™ NT compatible

486-50DX or higher

8MB RAM minimum, 16MB recommended

Hard disk requires 4.5MB for installation

Full memory download of 600KB requires 9.6MB on hard drive

Graphic Display: User adjustable contrast, LED backlight, 160x160 pixel, STN
Switch Keypad: 15 key membrane switch keypad, shielding protection, embedded dual color
red/green LED indicating power from line voltage or from batteries


Accessories
(67K) Amprobe Catalog



Test Leads & Alligator Clips (Set of 4)* DVL-2
Current Transducer (Black)* DM-CT-BK
Current Transducer (Red)* DM-CT-R
Current Transducer (Blue)* DM-CT-B
Current Transducer (Yellow)* DM-CT-Y
Output Lead* RS-232
Power Cord* PC-4
"DM-II View™ 3.5"" Discs (Set of 5)*" DISC-II
DM-II View™ Instruction Manual PIN 995754
Flexible Current Transducer (3000 Amps)** ACF-3000
Adapter for Flexible Current Transducer .
(BNC male to 2 Pin twist connector)** ACF-5
*Supplied
**Optional

(67K) Amprobe Catalog


Model: DM-III
Power Quality Recorder

  Home         Features | Specs | Accessories | Parts

  • Comes as a complete kit, CT’s and PC software are included with product
  • Works with single and three phase systems (Y and delta)
  • Detects and records voltage anomalies, Sags and Surges
  • Built in scope displays waveforms
  • Records up to 64 parameters (single or three phase)
  • Manual and programmable recording start
  • Password protection
  • Selectable fundamental frequency of 50 or 60 Hz
  • Special data compression system and user selectable
  • Manual and programmable recording start
  • Download capabilities, Windows compatible PC software
  • Line or battery powered

Unit Price: $3500.00  
  F E A T U R E S
Safety:      CATIII 600V Phase to Phase, CATIII 300V Phase to Ground, EN 61010-1+A2(1996)
Instruction Manual:      dmiii.pdf
Detailed Specs:      dmiii.pdf

  S P E C I F I C A T I O N S

AC Voltage including Sags and Surges:     0 - 600V
AC Current:     5 - 1000A (expandable to 3000A with optional CT’s)
Power:     Working (W), Reactive (VAR) and Apparent (VA)
Power Factor:     0.00 – 1.00
Energy:     Working (kWh), Reactive (VARh) and Apparent (VAh)
Peak Demand:     kW
Harmonics:     Up to 49 th
Frequency measurement:     57 to 63.6 Hz at 60Hz fundamental, 47 to 53 Hz at 50Hz fundamental
Phase sequence:     1/2/2003
Co-generation:     Computes incoming and outgoing energy
Selectable Fundamental Frequencies:     50/60 Hz
Available Recording Time:     Several hours to several years depending on setup

  O P T I O N A L    A C C E S S O R I E S

Part Number     Description
ACF-3000SR Optional Flexible Current Transducer For DM-III

  R E P L A C E M E N T    P A R T S      (supplied with product)

Part Number     Description
HW1254A Carrying Case For DM-III
DM-EXTPS External Power Supply 12VDC
DM-CT-HT Current Transducer For DM-III
KITENERGY3 Test Leads And Alligator Clips (Set of 4)
C232NG1 Special Download Cable

(67K) Amprobe Catalog                  

Amprobe products


CLAMP ON METERS

CONTINUITY TESTERS

DATALOGGERS

ENVIRONMENTAL

GROUND RESISTANCE

LEAK DETECTORS

MULTIMETERS

OHM - MEGOHM METERS

PHASE ROTATION

POWER

SOUND METERS

VOLTAGE TESTERS

WIRE TRACERS
   

 


Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117