|
Bridge
(Strain Gauge) Input Alarms
Bridge (Strain Gauge) Input Transmitters
Click on model number for data sheet and application information
|
Looptracker® LEDs
Output Test Button
Lifetime Warranty |
Reference Info
Alarm
Terminology
Deadband
Relay
Protection & EMI Suppression
Troubleshooting
Strain Gauge Type Sensors |
Model
|
Input Ranges
|
Output Ranges
|
Features
|

|
API
1500 G
Bridge Input Single Alarm Trip |
Specify Input Range
Factory Configured
Minimum: 5mVDC
Maximum: 1200mVDC
Specify Excitation Voltage
4-10 VDC
|
1 DPDT 7A
Contact Set
Field Adjustable
See Data Sheet for Alarm Options
|
- Looptracker LEDs for Input
- Alarm Status LEDs
- Internal Bridge Excitation Source
- Push to Test/Reset
- Uses API-011 11-Pin Socket
- Specify Power; 115VAC Std.
Opt. 230VAC or 9-30 VDC
|

|
API
1520 G
Bridge Input Dual Alarm Trip |
2 SPDT 7A
Contact Sets
Field Adjustable
See Data Sheet for Alarm Options
|
API
4051 G
Bridge to DC Transmitter |
Specify Input Range
Factory Configured
Others Available
1mV/V
2mV/V
3mV/V
5mV/V
10mV/V
20mV/V
50mV/V
100mV/V
200mV/V
Specify Excitation Voltage 4-10 VDC
|
Specify Output Range
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
±5V
±10V
0-20mA
4-20mA
|
- Looptracker LEDs for Input and Output
- Internal Bridge Excitation Source
- Output Test Button
- Uses API-011 11-Pin Socket
- Specify Power; 115VAC Std.
Opt. 230VAC or 9-30VDC
|

|
API
4058 G
Field Selectable Minuteman Setup
Bridge to DC Transmitter |
Field Configurable
0-5mVDC to
0-1200mVDC
Field Settable Excitation Voltage
0-10VDC in 1VDC Steps
|
18 Field Configurable Outputs
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
|
- Minuteman One-Minute Setup
- I/O Looptracker LEDs
- Internal Bridge Excitation Source
- Drive up to 4 bridges
- Output Test Button
- Uses API-011 11-Pin Socket
- Specify Power; 115VAC Std.
Opt. 230VAC or 9-30VDC
|

|
API
4059 G
Field Selectable Minuteman Setup
Isolated Bridge to DC Transmitter |
Field Configurable
0-5mVDC to
0-400mVDC
Field Settable Excitation Voltage
0-10VDC in 1VDC Steps
|
18 Field Configurable Outputs
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
|
- Minuteman One-Minute Setup
- I/O Looptracker LEDs
- Full I/O/Power Isolation
- Internal Bridge Excitation Source
- Drive up to 4 bridges
- Output Test Button
- Uses API-011 11-Pin Socket
- Specify Power; 115VAC Std.
- Opt. 230VAC or 9-30VDC
|

Socket Sold Separately
|
API
4059 DIN
Field Selectable Minuteman Setup
Isolated Bridge to DC Transmitter |
Field Configurable
0-5mVDC to
0-400mVDC
Field Settable Excitation Voltage
0-10VDC in 1VDC Steps
|
18 Field Configurable Outputs
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
|
- Minuteman One-Minute Setup
- I/O Looptracker LEDs
- Full I/O/Power Isolation
- Internal Bridge Excitation Source
- Drive up to 4 bridges
- Output Test Button
- DIN Rail or Surface Mount
- 55 mm Wide
- Specify Power; 115 VAC Std.
- Optional 230 VAC or 9-30 VDC
|

|
API
SUM-000
Bridge Summing Assembly Board
API
SUM-025
Field Selectable Minuteman Setup
Bridge Summing Assembly Board with 4059 G, 115VAC
powered
API
SUM Board Instruction Manual
|
Provisions for up to Four 350 Ω or greater Bridges,
Strain Gauges or Load Cells
Switch for Internal or External Excitation.
Call Factory for Special Configurations
|
11-Pin Socket for
API 4059 G or
API 4058 G
|
- Connect up to 4 Bridges
- 4 Trim Pots for Excitation Adjust
- 4 Trim Pots for Signal Adjust
|

|