Love Series
LoveLink
Data Acquisition and Logging Software
Low Cost, Easy to Use Operator Interface

Service Manual
Catalog Page

LoveLink™II is the second generation of data acquisition software from Love Controls. This easy to use program allows connection of up to 40 controls on a single computer port. Data logging can be set up by individual control with varying logging periods. LoveLink ™II is compatible with all Love Controls 2600, 8600, 16A, 32DZ, and 32A Series controls.


POPULAR MODELS
Model
Number
Description Price
 LoveLinkII  Data Acquisition and Logging Software   $55.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

Required Equipment
Computer Requirements

The LOVELINK™II application will run on both Windows® 95/98 and Windows® NT™ Workstation 4.0 (Service Pack 3 recommended). The hardware requirements for each of these operating systems can be found in the documentation provided with that operating system. One available RS-232 or RS-485 port is needed to communicate with the temperature control(s). A minimum of 3 MB of hard disk space is needed for the LOVELINK™II application files, and additional hard disk space is needed to store temperature log files. Log file size will vary depending on the Duration and Rate selected for the controls and the number of controls on line.

Control Requirements
The temperature controls supported by LOVELINK™II are the Love 2600, 8600, 16A, and 32A Series (with Option 992, RS-485 Serial Communications or Option 993, RS-232 Serial Communications). (Note:The 32A Series supports RS-485 communications only.)

Other Requirements
To communicate with controls equipped with Option 992, RS-485 Serial Communications, from an RS-232 communications port,an RS-485 to RS-232 converter (Mother Node) is needed.The converter models recommended are the Love Models 351, 352, and 356. For RS-485 systems a 120-ohm resistor is also needed to terminate the last control on the control network. Shielded twisted pair cable is recommended for wiring the controls together

Dwyer Model
LCL
Low Cost Data Logger
Accurate and Affordable, Records Pressure Readings

NEW!
Pressure Version
Service Manual
Catalog Page

Dimensional Enlargement

Accurately measure and record the temperature, temperature/humidity or pressure in environmental chambers, coolers, food or storage areas and greenhouses with the Series LCL Low Cost Data Logger. Single channel temperature logger, model LCL10, includes a built-in thermistor to record up to 10,000 measurements. Model LCL20 logs temp and humidity with a capacity of 8000 samples and calculates dew point based on this data. For remote temperature measurements, select dual channel model LCL22 which includes 2 external temperature probes. Model LCL40 will record up to 16,000 pressure samples for each recording. Quickly start or stop recording via a slide switch with locking protection to avoid accidental shutoff. During recording, the built-in LED flashes every 5 seconds to indicate operation. The LCL05 Windows™ software (sold separately) allows you to set the sampling rate, read the recorded data in text or graphical format with selectable °F/°C or to store the recorded data for future use.

POPULAR MODELS
Model
Number
Input Type Price
 LCL10  Single Channel Temperature   $79.95
 LCL20  Temperature/Humidity/Dew Point   $109.95
 LCL22  Dual Channel Temperature   $139.95
 LCL40  Pressure   $179.95
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

ACCESSORIES
Model
Number
Description Price
 LCL05  Windows Software and cable   $49.95
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
Temp Range: -40 to 150°F (-40 to 65°C) (LCL10 and LCL22); 32 to 140°F (0 to 60°C) (LCL20).
Relative Humidity: 0 to 95% RH, non-condensing.
Dew Point: 32 to 140°F (0 to 60°F).
Pressure Range: 0 to 500 psig.
Resolution: Temperature: 0.1°F (0.2°C), Humidity (LCL20): 0.1%, Dew Point (LCL20): 1%; Pressure: 0.15 psi.
Accuracy: Temperature: ± 2°F (± 1°C), Humidity (LCL20): ± 2%.
External Temperature Probe: 4" 304 stainless steel submersible tip with 6' long cable (two included with Model LCL22).
Sampling Method: Stop when full.
Sampling Rate: Selectable from 5 seconds to 60 minutes.
Memory Size: 10,000 samples (LCL10); 8,000 samples (LCL20); 8,000 samples per channel (LCL22); 16,000samples for each recording.
Time Accuracy: ± 100 ppm @ 75°F.
Storage Temperature: -40 to 170°F (-40 to 76°C).
Power: 3.6V Lithium battery (LCL10) included; 9V Alkaline battery (LCL20, LCL22 and LCL40) not included.
Battery Life: 3 years (LCL10); 1 year (LCL20, LCL22 and LCL40) average.
Software Requirements: IBM compatible PC Windows™ 98, 95 and 3.11.
Housing: ABS Plastic.
Weight: 3 oz (85 g).
Dimensions: 2.5" x 3.6" x 1.1" (64 x 91 x 28 mm).

Dwyer Series
BDL
Button Data Logger
Compact size, RS-232 Interface, Capable of storing 2048 readings

BDL-K Shown

Dimensional Enlargement

The Series BDL Button Data Logger records temperatures in applications where size and cost effectiveness are key. The BDL is housed in a stainless steel case and is water resistant, making it durable in hostile environments where excessive moisture is present. The BDL is self-powered and is capable of storing up to 2048 readings in user selectable increments of 1 to 255 minutes. This Series can accurately record temperatures in the -4 to 158°F (-20°C to 70°C) temperature range. The Model BDL-K Logger kit includes two buttons, 2 plastic holders, interface cable, and Windows software.

POPULAR MODELS
Model
Number
Description Price
 BDL-10  (Single Button)   $35.00
 BDL-K  (Kit)   $99.99
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

APPLICATIONS
Food processing verification, pharmaceutical storage, laboratories, transportation of temperature sensitive goods, equipment run time, HVAC system testing and balancing.

SPECIFICATIONS
No. of Channels: One internal temperature sensor.
Internal Temperature Sensor: -4 to 185°F (-20 to 85°C).
Operating Limits: -4 to 185°F (-20 to 85°C).
Resolution: 8-bits-0.9°F (0.5°C).
Memory Size: Capable of storing 2048 readings.
Alarm Thresholds: User selectable, event storage.
Sampling Rates: User selectable rates from 1 to 255 minutes.
Sampling Methods: Continous (First-in, First-out) Stop when full.
Start Delay: Up to 255 minutes.
Clock Accuracy: ±2 seconds per month.
PC Requirements: IBM or PC or 100% compatible Pentium 75 with at least one free serial port, 16MB of RAM memory, color monitor and mouse.
Software Requirements: Button Data Logger For Windows Versions 95, 98, NT or 2000.
Mounting: User selectable.
Weight: 14 oz (4 g).
Battery Life: 10 years, approximately.

Dwyer Model
MTL10
Mini Temperature Data Logger
High/Low Temperature Alarm with Visual Indication, Software Included.

Catalog Page

Dimensional Enlargement

Measure and record the temperature of the surounding environment with the Model MTL10 Mini Temperature Data Logger. Each unit is factory calibrated to an accuracy of ±0.9°F (±0.5°C) over the operating range of -40 to 185°F (-40 to 85°C). Model MTL10 can store up to 2048 temperature measurements and can be set for continous measurement or stop recording when the memory becomes full. Sampling raate is selectable from one minute to once every 4 hours. Recordings can be programmed to begin immediately, delayed (up to 6 weeks), or initiated by a push button. The logger has visual indication of an alarm condition without the need to connect to the computer.


POPULAR MODELS
Model
Number
Description Price
 MTL10  Mini Temperature Data Logger   $69.99
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
Temperature Range: -40 to 185°F (-40 to 85°C).
Temperature Resolution: ±0.9°F (±0.5°C)
Accuracy: ±0.9°F (±0.5°C)
Sampling Rate: Selectable from 1 min. to 4 hrs. in 1 min. increments.
Storage Capacity: 2048 samples
Interface: RS232 Serial Port.
Alarms: Programmable high/low
Alarm Memory: Up to 12 temperature high and 12 temperature low
Recording Start: Push button, computer controlled or up to 6 week delayed start
Recording Mode: Stop on memory full or continous recording with memory rollover
Real Time Clock: Displays seconds, minutes, hours, month, day of the week, and year
Real Time Status: Updated every second
Power: 3.0V Lithium battery
Batery Life: 3 years (approx).
Software Requirements: Intel compatible 486 or above and Windows 95 or later with 8 mB RAM and 2 mB hard drive disk space, one free RS232 port.
Housing: ABS plastic.
Weight: 3 oz. (85 g)

Dwyer Model
LS1
Data Logger Storage
For use with Series LCL Data Loggers, Capacity of 31 Data Loggers

Service Manual
Catalog Page

Dimensional Enlargement

Collect Data from your series LCL Low Cost Data Logger simply and easily with Dwyer's Model LS1Loggerstor. This data storage unit is battery powered, hand held instrument that allows the user to retrieve and store the full recordings from 31 Series LCL data loggers View the retrieved data on the alphanumeric display, print to any parallel printer or transfer recordings to a PC. Each recording is individually identified for easy tracking. Unit comes complete with battery, carrying case and logger connection cable.

 

POPULAR MODELS
Model
Number
Description Price
 LS1  Data Logger Storage   $179.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
Storage Capacity: Full recordings up to 31 LCL data loggers.
Logger Connection: DB25 female with custom cable (included).
Printer Connection: Parallel printer cable (not included)
Temperature Limits:
Operating: 32°F to 140°F (0°C to 60°C).
Storage: -40°F to 170°F (-40°C to 76°C).
Power: 9V alkaline battery (included).
Display: Alphanumerbic LCD, 16 characters; 2 lines
Weight:13 oz (369 g).


Dwyer Model
DL001
Temperature Data Logger
Self Powered, 2-Channel, Stores up to 32,768 Readings, Compact

Service Manual
Catalog Page

Dimensional Enlargement

Record temperature in a wide range of applications including HVAC testing and balancing, transportation, and energy management with the Model DL001 Temperature Data Logger. Temperature logger has an on-board thermistor and an external sensor channel for remote temperature measurements. Microprocessor controlled circuitry includes solid state memory that can store up to 32,768 readings. Model DL001 logger operates totally independently from any external power supply with built-in lithium battery. Units feature a magnetic backing and locking hole for easy and secure mounting. Quickly program the temperature logger or upload data to a computer using Model DL200 Windows™ software (sold separately).

POPULAR MODEL
Model
Number
Description Price
 DL001  Temperature Data Logger   $399.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

ACCESSORIES
Model
Number
Description Price
 DL200  Windows Software and Connecting Cable   $159.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
No. of Channels: Two, one internal thermistor and one external temperature sensor.
Internal Thermistor Range: -40 to 158°F (-40 to 70°C).
Internal Thermistor Resolution: 0.7°F (0.4°C), R25 value equal to 10,000W.
External Sensor: Interchangeable NTC (negative temperature coefficient) thermistor recommended (not included).
Memory Size: 32,768 readings.
Sampling Methods: Continuous (First-in, First-out) or Stop when full (Fill-then-stop).
Sampling Rates: 8 seconds to once every 5 days, selectable.
Resolution: 8 bits (1 in 256).
Power: 3.6V Lithium battery.
Power Consumption: 5-10 mA.
Clock Accuracy: ± 8 seconds per day plus one sampling interval.
Ambient Operating Temp: -50 to 160°F (-45 to 70°C), 0 to 95% RH, non-condensing.
Connection: Removable screw terminal.
Computer Requirements: IBM compatible 386 or above and Windows 3.1 or later with 2mB RAM and 2mB hard drive disk space, one serial port.
Housing: Noryl™.
Weight: 5 oz (110 g).

Dwyer Series
DL6
Pressure/Temperature/RH Data Logger
Self-Powered, 5-channel, Store up to 32,768 Readings, Compact

Service Manual
Catalog Page

Dimensional Enlargement

Monitor and troubleshoot HVAC systems, verify energy management systems, or track performance of pneumatically controlled valves with Series DL6 Pressure/Temperature/RH Data Logger. Units include an on-board thermistor for ambient temperature measurement and pressure module. Remote humidity/temperature sensor and plug-in humidity sensor are sold separately. Loggers can store up to 32,768 readings and operate totally independently from any external power supply with built-in lithium battery. Use Model DL200 Windows™ software (sold separately) to quickly program the logger or upload data to the computer.

POPULAR MODELS
Model
Number
Pressure Range Price
 DL6005  0 to 5 psig (30 kPa)   $875.00
 DL6030  0 to 30 psig (200 kPa)   $875.00
 DL6100  0 to 100 psig (700 kPa)   $875.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

 

ACCESSORIES
Model
Number
Description Price
 DL200  Windows Software and Connecting Cable   $159.00
 DL690  Remote Humidity/Temperature Sensor   $235.00
 DL691  Plug-in Humidity Sensor   $215.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
No. of Channels: Five; internal thermistor, pressure module (included), plug-in humidity sensor, remote humidity/temperature sensor
Internal Thermistor Range: -40 to 158° F (-40 to 70° C).
Internal Thermistor Resolution: 0.7° F (0.4° C), R25 value equal to 10,000 ohm.
Media: Air and noncorrosive gases.
Max Pressure Rating: 4x pressure range
Compensated Temp Range: 32 to 158° F (0 to 70°C)
Accuracy: ±1% FS
Thermal Accuracy: ±1% FS
Stability: ± 0.2% FS/yr
Memory Size: 32,768 readings.
Sampling Method: Continuous (First-in, First-out) or Stop when full(Fill-then-stop).
Sampling Rate: Selectable from 8 seconds to once every 5 days.
Resolution: 8 bits (1 in 256).
Power: Built-in 3.6V Lithium battery.
Power Consumption: 5 to 10 microAmps.
Clock Accuracy: ±8 sec/day plus one sampling interval.
Ambient Operating Temp: -50 to 160° F (-45 to 70° C), 0 to 95% RH, non-condensing.
Connection: Removable Screw Terminal.
Computer Requirements: IBM compatible 386 or above and Windows (3.1 or later) with 2MB RAM and 2MB hard drive disk space, one serial port.
Housing: Noryl™
Weight: 5 oz.(110 g)

Dwyer Series
DL7
Differential Pressure Data Logger
Also Measures and Logs Temperature, Self-Powered, 2-channel, Compact

Service Manual
Catalog Page

Dimensional Enlargement

Monitor and Record low differential pressures and temperature with the model DL7 Differential Pressure Data Logger. Unit includes an onboard thermistor for ambient temperature measurement. Sampling rates are user selectable from 0.04 seconds to 8 hours with First-in first-out or Fill-then-stop sampling options. Loggers can store up to 21,500 readings and operate totally independantly from any external power supply with built-in lithium battery. Use Model DL200 Windows™ software (sold separtely) to quickly program the logger or upload data to a computer. The series DL7 logger is ideal for monitoring air duct velocity, testing and balancing HVAC systems, or verifying room pressure.

POPULAR MODELS
Model
Number
Pressure Range Price
 DL70  ±0.5" w.c. (1.2 mbar)   $799.00
 DL71  ±1" w.c. (2.5 mbar)   $799.00
 DL72  ±2.5" w.c. (6.2 mbar)   $799.00
 DL75  ±5" w.c. (12.4 mbar)   $799.00
 DL710  ±10" w.c. (24.9 mbar)   $799.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

 

ACCESSORIES
Model
Number
Pressure Range Price
 DL200  Windows Software and Connecting Cable   $159.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
No. of Channels: Two; internal thermistor, and a differential pressure sensor.
Media: Dry air and noncorrosive gases
Max. Pressure Rating: 5 x pressure range
Accuracy: ± 0.05" w.c.
Resolution: ± 0.01" w.c.
Nonlinearity: ± 0.05% FS (BFSL)
Hysteresis and Repeatability: ± 0.05% FS
Internal Thermistor Range: -40 to 158°F (-40 to 70°C)
Internal Thermistor Resolution: 0.7°F (0.4°C), R25 value equal to 10,000 Ohm [10 KOhm @ 25° C (77° F)]
Compensated Temp Range: 32 to 158°F (0 to 70°C).
Thermal Accuracy: ± 0.5% FS.
Memory Size: 21,500 readings.
Resolution: 12 bits( 1 in 4096)
Stability: ± 0.5 % FS/yr
Sampling Methods: Continuous (First-in, First-out: not available from 40 ms to 8 sec.), Stop when full (Fill-then-stop), or Delayed Start.
Sampling Rates: Selectable from 0.04 seconds to 8 hours
Power: Built-in 3.6 V Lithium Battery
Power Consumption: 5 - 10 micro Amps
Clock Accuracy:
±2 sec/day plus one sampling interval
Ambient Operating Temp: -40 to 158°F (-40 to 70°C), 0 to 95% RH, non-condensing.
Connection: Two 1/8" I.D. permanent protective tubing
Computer Requirements: IBM compatible 386 or above and Windows (3.1 or later) with 2MB RAM and 2MB hard drive disk space, one serial port.
Housing: Noryl™
Weight: 4 oz (110 g).

Dwyer Series
DL8
Process Data Logger
8-Channels, Compact, Self-Powered, Stores up to 32,768 Readings

Service Manual
Catalog Page

Dimensional Enlargement

Eliminate traditional paper chart recorders with the Series DL8 Process Data Logger. This versatile, multi-channel data logger monitors and stores up to 32,768 process readings for later download to IBM compatible computer. Seven external input channels easily interface with common transducer and transmitter outputs. Internal thermistor measures ambient temperature outputs. Internal thermistor measures ambient temperature conditions. Programming is simple and easy with the DL200 Windows™ software and connecting cable (sold separately). The Series DL8 Process Data Logger is ideal for monitoring temperature, relative humidity, pressure, wind speed, current, voltage and power.

POPULAR MODELS
Model
Number
Input Type Price
 DL8  0-2.5 VDC, 0-5 VDC(2 ch.), 0-10 VDC, 0-200mV DC, and 0-25mA DC(2 ch.)   $739.00
 DL81  All channels 0 to 25mA   $839.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

ACCESSORIES
Model
Number
Description Price
 DL200  Windows Software and Cable   $159.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
No. Of Channels: Eight; One for internal thermistor and seven for external analog inputs.
Accuracy: ± 1% of full scale.
Internal Thermistor Range: -40 to 158°F (-40 to 70°C).
Memory Size: 32,768 readings.
Sampling Methods: Continuous (First-in, First-out) or Stop when full (Fill-then-stop).
Sampling Rates Selectable from 8 seconds to once every 5 days.
Resolution: 8 bits (1 in 256).
Power: Built-in 3.6V Lithium battery.
Power Consumption: 5-10 micro-Amps.
Clock Accuracy: ± 8 seconds per day plus one sampling interval.
Ambient Operating TEMP: -50 to 160°F (-45 to 70°C), 0 to 95% RH, non-condensing.
Connection: Removable screw terminal.
Computer Requirements: IBM Compatible 386 or above and Windows™ 3.1 or later with 2 mB RAM and 2 mB hard disk space, one serial port.
Housing: Noryl™.
Weight: 5 oz (110 g).

Dwyer Series
PD
Pro-Data Programmable Data Logger
Measure Temperature, Humidity, Dew Point, Pressure, or Voltage

Service Manual
Catalog Page

Dimensional Enlargement

Read, measure, and record temperature, humidity, dew point, pressure, and voltage with the multifunction Series PD Pro-Data Programmable Data Logger. The handheld measuring instrument has the capablility to record 4000 day/time stamped samples and store data up to 40 days. The nonvolatile memory will retain recorded information in the absence of power to be recalled later. Recorded data can be viewed on the alphanumeric LCD display, sent directly to a printer, or transferred to an IBM compatible computer for later analysis.

The dual channel logger uses plug-in sensors to measure the desired parameters. Sensors are available in three different configurations - temperature/humidity/dew point, temperature/pressure, or temperature/voltage. All sensors are field interchangeable for application flexibility and do not require recalibration when changed. Unit features programmable sampling rate, selectable °F or °C, backlit display, and rear panel keyholes for permanent mounting.

POPULAR MODELS
Model
Number
Sensors Included Price
 PD101  Temperature/Humidity/Dew Point   $459.00
 PD201  Temperature/Pressure   $635.00
 PD301  Temperature/Voltage   $459.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

 

ACCESSORIES
Model
Number
Description Price
 PD7  Replacement Temperature/Humidity Sensor   $165.00
 PD8  Replacement Pressure/Temperature Sensor   $270.00
 PD9  Replacement Temperature/Event Sensor   $165.00
 PD77  10 ft. Extension Cable for Humidity/Temperature Sensor   $25.00
 PD85  25 ft. Extension for Pressure/Temperature/Event Sensor   $21.00
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.

SPECIFICATIONS
Recording Time: 5 hr, 15 hr, 30 hr, 60 hr, 2 weekds, or 40 days (field selectable).
Sampling Rates: Field selectable from 5 seconds to 15 minutes.
Memory Size: 4,000 samples.
Temperature/Humidity/Dew Point Sensor: 4" plastic temp sensor for air only; Temp. Range: -40 to 170°F (-40 to 75°C), Accuracy: ± 2°F (± 1°C); Humidity Range: 0 to 100% @ 32 to 130°F (0 to 55°C), Accuracy: ± 2%; Dew Point Range: 32 to 130°F (0 to 55°C).
Temperature/Pressure Sensor: 4" SS submersible temp sensor; Temp. Range: -40 to 170°F (-40 to 75°C), Accuracy: ± 2°F (± 1°C); Press. Range: 0 to 500 psi (0 to 35 bar), accuracy: ± 1% FS.
Temperature/Voltage Sensor: 4" SS submersible temp sensor; Temp. Range: -40 to 170°F (-40 to 75°C), Accuracy: ± 2°F (± 1°C); Voltage Range: 24 to 270 VAC, 24 to 180 VDC.
Display: Alphanumeric backlit LCD, 16 characters x 2 lines.
Cable Length: All are 6 ft (1.8 m).
Power: 115 VAC 50/60 Hz adapter (220 VAC available) or 9V alkaline battery for 24 hr backup power source (not included). External power may be supplied from any 12 VDC source.
Printer Interface: Parallel centronics compatible printer port.
Computer Requirements: IBM compatible 286 or above and MS-DOS 3.0 or later. DB25 Male-Male.
Weight: 10 oz (284 g).

 

 

Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117