Series
LoveLink™ |
Data Acquisition and
Logging Software
Low Cost, Easy to Use Operator Interface |
|
LoveLink™II is the second generation of data acquisition
software from Love Controls. This easy to use program allows connection
of up to 40 controls on a single computer port. Data logging can be set
up by individual control with varying logging periods. LoveLink ™II is
compatible with all Love Controls 2600, 8600, 16A, 32DZ, and 32A Series
controls.
POPULAR
MODELS
Model
Number |
Description |
Price |
| LoveLinkII |
Data Acquisition and Logging Software |
$55.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
Required Equipment
Computer Requirements
The LOVELINK™II application will run on both Windows® 95/98 and
Windows® NT™ Workstation 4.0 (Service Pack 3 recommended). The
hardware requirements for each of these operating systems can be found
in the documentation provided with that operating system. One available
RS-232 or RS-485 port is needed to communicate with the temperature
control(s). A minimum of 3 MB of hard disk space is needed for the
LOVELINK™II application files, and additional hard disk space is
needed to store temperature log files. Log file size will vary depending
on the Duration and Rate selected for the controls and the number of
controls on line.
Control Requirements
The temperature controls supported by LOVELINK™II are the Love 2600,
8600, 16A, and 32A Series (with Option 992, RS-485 Serial Communications
or Option 993, RS-232 Serial Communications). (Note:The 32A Series
supports RS-485 communications only.)
Other Requirements
To communicate with controls equipped with Option 992, RS-485 Serial
Communications, from an RS-232 communications port,an RS-485 to RS-232
converter (Mother Node) is needed.The converter models recommended are
the Love Models 351, 352, and 356. For RS-485 systems a 120-ohm resistor
is also needed to terminate the last control on the control network.
Shielded twisted pair cable is recommended for wiring the controls
together
|
 |
Model
LCL |
Low Cost Data Logger
Accurate and Affordable, Records Pressure Readings |
 |
|
Accurately measure and record the temperature,
temperature/humidity or pressure in environmental chambers, coolers,
food or storage areas and greenhouses with the Series LCL Low Cost Data
Logger. Single channel temperature logger, model LCL10, includes a
built-in thermistor to record up to 10,000 measurements. Model LCL20
logs temp and humidity with a capacity of 8000 samples and calculates
dew point based on this data. For remote temperature measurements,
select dual channel model LCL22 which includes 2 external temperature
probes. Model LCL40 will record up to 16,000 pressure samples for each
recording. Quickly start or stop recording via a slide switch with
locking protection to avoid accidental shutoff. During recording, the
built-in LED flashes every 5 seconds to indicate operation. The LCL05
Windows™ software (sold separately) allows you to set the sampling
rate, read the recorded data in text or graphical format with selectable
°F/°C or to store the recorded data for future use.
POPULAR
MODELS
Model
Number |
Input Type |
Price |
| LCL10 |
Single Channel Temperature |
$79.95 |
| LCL20 |
Temperature/Humidity/Dew Point |
$109.95 |
| LCL22 |
Dual Channel Temperature |
$139.95 |
| LCL40 |
Pressure |
$179.95 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
ACCESSORIES
Model
Number |
Description |
Price |
| LCL05 |
Windows Software and cable |
$49.95 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
Temp Range: -40 to 150°F (-40 to 65°C) (LCL10 and LCL22); 32 to
140°F (0 to 60°C) (LCL20).
Relative Humidity: 0 to 95% RH, non-condensing.
Dew Point: 32 to 140°F (0 to 60°F).
Pressure Range: 0 to 500 psig.
Resolution: Temperature: 0.1°F (0.2°C), Humidity (LCL20): 0.1%,
Dew Point (LCL20): 1%; Pressure: 0.15 psi.
Accuracy: Temperature: ± 2°F (± 1°C), Humidity (LCL20): ±
2%.
External Temperature Probe: 4" 304 stainless steel
submersible tip with 6' long cable (two included with Model LCL22).
Sampling Method: Stop when full.
Sampling Rate: Selectable from 5 seconds to 60 minutes.
Memory Size: 10,000 samples (LCL10); 8,000 samples (LCL20); 8,000
samples per channel (LCL22); 16,000samples for each recording.
Time Accuracy: ± 100 ppm @ 75°F.
Storage Temperature: -40 to 170°F (-40 to 76°C).
Power: 3.6V Lithium battery (LCL10) included; 9V Alkaline battery
(LCL20, LCL22 and LCL40) not included.
Battery Life: 3 years (LCL10); 1 year (LCL20, LCL22 and LCL40)
average.
Software Requirements: IBM compatible PC Windows™ 98, 95 and
3.11.
Housing: ABS Plastic.
Weight: 3 oz (85 g).
Dimensions: 2.5" x 3.6" x 1.1" (64 x 91 x 28 mm).
|
 |
Series
BDL |
Button Data Logger
Compact size, RS-232 Interface, Capable of
storing 2048 readings |
|
The Series BDL Button Data Logger records temperatures in
applications where size and cost effectiveness are key. The BDL is
housed in a stainless steel case and is water resistant, making it
durable in hostile environments where excessive moisture is present. The
BDL is self-powered and is capable of storing up to 2048 readings in
user selectable increments of 1 to 255 minutes. This Series can
accurately record temperatures in the -4 to 158°F (-20°C to 70°C)
temperature range. The Model BDL-K Logger kit includes two buttons, 2
plastic holders, interface cable, and Windows software.
POPULAR
MODELS
Model
Number |
Description |
Price |
| BDL-10 |
(Single Button) |
$35.00 |
| BDL-K |
(Kit) |
$99.99 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
APPLICATIONS
Food processing verification, pharmaceutical storage, laboratories,
transportation of temperature sensitive goods, equipment run time, HVAC
system testing and balancing.
|
SPECIFICATIONS
No. of Channels: One internal temperature sensor.
Internal Temperature Sensor: -4 to 185°F (-20 to 85°C).
Operating Limits: -4 to 185°F (-20 to 85°C).
Resolution: 8-bits-0.9°F (0.5°C).
Memory Size: Capable of storing 2048 readings.
Alarm Thresholds: User selectable, event storage.
Sampling Rates: User selectable rates from 1 to 255 minutes.
Sampling Methods: Continous (First-in, First-out) Stop when full.
Start Delay: Up to 255 minutes.
Clock Accuracy: ±2 seconds per month.
PC Requirements: IBM or PC or 100% compatible Pentium 75 with at
least one free serial port, 16MB of RAM memory, color monitor and mouse.
Software Requirements: Button Data Logger For Windows Versions
95, 98, NT or 2000.
Mounting: User selectable.
Weight: 14 oz (4 g).
Battery Life: 10 years, approximately.
|
 |
Model
MTL10 |
Mini Temperature Data Logger
High/Low Temperature Alarm with Visual Indication,
Software Included. |
 |
|
Measure and record the temperature of the surounding
environment with the Model MTL10 Mini Temperature Data Logger. Each unit
is factory calibrated to an accuracy of ±0.9°F (±0.5°C) over the
operating range of -40 to 185°F (-40 to 85°C). Model MTL10 can store
up to 2048 temperature measurements and can be set for continous
measurement or stop recording when the memory becomes full. Sampling
raate is selectable from one minute to once every 4 hours. Recordings
can be programmed to begin immediately, delayed (up to 6 weeks), or
initiated by a push button. The logger has visual indication of an alarm
condition without the need to connect to the computer.
POPULAR
MODELS
Model
Number |
Description |
Price |
| MTL10 |
Mini Temperature Data Logger |
$69.99 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
Temperature Range: -40 to 185°F (-40 to 85°C).
Temperature Resolution: ±0.9°F (±0.5°C)
Accuracy: ±0.9°F (±0.5°C)
Sampling Rate: Selectable from 1 min. to 4 hrs. in 1 min.
increments.
Storage Capacity: 2048 samples
Interface: RS232 Serial Port.
Alarms: Programmable high/low
Alarm Memory: Up to 12 temperature high and 12 temperature low
Recording Start: Push button, computer controlled or up to 6 week
delayed start
Recording Mode: Stop on memory full or continous recording with
memory rollover
Real Time Clock: Displays seconds, minutes, hours, month, day of
the week, and year
Real Time Status: Updated every second
Power: 3.0V Lithium battery
Batery Life: 3 years (approx).
Software Requirements: Intel compatible 486 or above and Windows
95 or later with 8 mB RAM and 2 mB hard drive disk space, one free RS232
port.
Housing: ABS plastic.
Weight: 3 oz. (85 g)
|
 |
Model
LS1 |
Data Logger Storage
For use with Series LCL Data Loggers, Capacity of 31
Data Loggers |
 |
|
Collect Data from your series LCL Low Cost Data Logger simply
and easily with Dwyer's Model LS1Loggerstor. This data storage unit is
battery powered, hand held instrument that allows the user to retrieve
and store the full recordings from 31 Series LCL data loggers View the
retrieved data on the alphanumeric display, print to any parallel
printer or transfer recordings to a PC. Each recording is individually
identified for easy tracking. Unit comes complete with battery, carrying
case and logger connection cable.
POPULAR
MODELS
Model
Number |
Description |
Price |
| LS1 |
Data Logger Storage |
$179.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
Storage Capacity: Full recordings up to 31 LCL data loggers.
Logger Connection: DB25 female with custom cable (included).
Printer Connection: Parallel printer cable (not included)
Temperature Limits:
Operating: 32°F to 140°F (0°C to 60°C).
Storage: -40°F to 170°F (-40°C to 76°C).
Power: 9V alkaline battery (included).
Display: Alphanumerbic LCD, 16 characters; 2 lines
Weight:13 oz (369 g).
|
 |
Model
DL001 |
Temperature Data Logger
Self Powered, 2-Channel, Stores up to 32,768 Readings,
Compact |
 |
|
Record temperature in a wide range of applications including
HVAC testing and balancing, transportation, and energy management with
the Model DL001 Temperature Data Logger. Temperature logger has an
on-board thermistor and an external sensor channel for remote
temperature measurements. Microprocessor controlled circuitry includes
solid state memory that can store up to 32,768 readings. Model DL001
logger operates totally independently from any external power supply
with built-in lithium battery. Units feature a magnetic backing and
locking hole for easy and secure mounting. Quickly program the
temperature logger or upload data to a computer using Model DL200
Windows™ software (sold separately).
POPULAR
MODEL
Model
Number |
Description |
Price |
| DL001 |
Temperature Data Logger |
$399.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
ACCESSORIES
Model
Number |
Description |
Price |
| DL200 |
Windows Software and Connecting Cable |
$159.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
No. of Channels: Two, one internal thermistor and one external
temperature sensor.
Internal Thermistor Range: -40 to 158°F (-40 to 70°C).
Internal Thermistor Resolution: 0.7°F (0.4°C), R25 value equal
to 10,000W.
External Sensor: Interchangeable NTC (negative temperature
coefficient) thermistor recommended (not included).
Memory Size: 32,768 readings.
Sampling Methods: Continuous (First-in, First-out) or Stop when
full (Fill-then-stop).
Sampling Rates: 8 seconds to once every 5 days, selectable.
Resolution: 8 bits (1 in 256).
Power: 3.6V Lithium battery.
Power Consumption: 5-10 mA.
Clock Accuracy: ± 8 seconds per day plus one sampling interval.
Ambient Operating Temp: -50 to 160°F (-45 to 70°C), 0 to 95% RH,
non-condensing.
Connection: Removable screw terminal.
Computer Requirements: IBM compatible 386 or above and Windows
3.1 or later with 2mB RAM and 2mB hard drive disk space, one serial
port.
Housing: Noryl™.
Weight: 5 oz (110 g).
|
 |
Series
DL6 |
Pressure/Temperature/RH Data Logger
Self-Powered, 5-channel, Store up to 32,768 Readings,
Compact |
 |
|
Monitor and troubleshoot HVAC systems, verify energy
management systems, or track performance of pneumatically controlled
valves with Series DL6 Pressure/Temperature/RH Data Logger. Units
include an on-board thermistor for ambient temperature measurement and
pressure module. Remote humidity/temperature sensor and plug-in humidity
sensor are sold separately. Loggers can store up to 32,768 readings and
operate totally independently from any external power supply with
built-in lithium battery. Use Model DL200 Windows™ software (sold
separately) to quickly program the logger or upload data to the
computer.
POPULAR
MODELS
Model
Number |
Pressure Range |
Price |
| DL6005 |
0 to 5 psig (30 kPa) |
$875.00 |
| DL6030 |
0 to 30 psig (200 kPa) |
$875.00 |
| DL6100 |
0 to 100 psig (700 kPa) |
$875.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
ACCESSORIES
Model
Number |
Description |
Price |
| DL200 |
Windows Software and Connecting Cable |
$159.00 |
| DL690 |
Remote Humidity/Temperature Sensor |
$235.00 |
| DL691 |
Plug-in Humidity Sensor |
$215.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
No. of Channels: Five; internal thermistor, pressure module
(included), plug-in humidity sensor, remote humidity/temperature sensor
Internal Thermistor Range: -40 to 158° F (-40 to 70° C).
Internal Thermistor Resolution: 0.7° F (0.4° C), R25 value
equal to 10,000 ohm.
Media: Air and noncorrosive gases.
Max Pressure Rating: 4x pressure range
Compensated Temp Range: 32 to 158° F (0 to 70°C)
Accuracy: ±1% FS
Thermal Accuracy: ±1% FS
Stability: ± 0.2% FS/yr
Memory Size: 32,768 readings.
Sampling Method: Continuous (First-in, First-out) or Stop when
full(Fill-then-stop).
Sampling Rate: Selectable from 8 seconds to once every 5 days.
Resolution: 8 bits (1 in 256).
Power: Built-in 3.6V Lithium battery.
Power Consumption: 5 to 10 microAmps.
Clock Accuracy: ±8 sec/day plus one sampling interval.
Ambient Operating Temp: -50 to 160° F (-45 to 70° C), 0 to 95%
RH, non-condensing.
Connection: Removable Screw Terminal.
Computer Requirements: IBM compatible 386 or above and Windows
(3.1 or later) with 2MB RAM and 2MB hard drive disk space, one serial
port.
Housing: Noryl™
Weight: 5 oz.(110 g)
|
 |
Series
DL7 |
Differential Pressure Data Logger
Also Measures and Logs Temperature, Self-Powered,
2-channel, Compact |
 |
|
Monitor and Record low differential pressures and temperature
with the model DL7 Differential Pressure Data Logger. Unit includes an
onboard thermistor for ambient temperature measurement. Sampling rates
are user selectable from 0.04 seconds to 8 hours with First-in first-out
or Fill-then-stop sampling options. Loggers can store up to 21,500
readings and operate totally independantly from any external power
supply with built-in lithium battery. Use Model DL200 Windows™
software (sold separtely) to quickly program the logger or upload data
to a computer. The series DL7 logger is ideal for monitoring air duct
velocity, testing and balancing HVAC systems, or verifying room
pressure.
POPULAR
MODELS
Model
Number |
Pressure Range |
Price |
| DL70 |
±0.5" w.c. (1.2 mbar) |
$799.00 |
| DL71 |
±1" w.c. (2.5 mbar) |
$799.00 |
| DL72 |
±2.5" w.c. (6.2 mbar) |
$799.00 |
| DL75 |
±5" w.c. (12.4 mbar) |
$799.00 |
| DL710 |
±10" w.c. (24.9 mbar) |
$799.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
ACCESSORIES
Model
Number |
Pressure Range |
Price |
| DL200 |
Windows Software and Connecting Cable |
$159.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
No. of Channels: Two; internal thermistor, and a differential
pressure sensor.
Media: Dry air and noncorrosive gases
Max. Pressure Rating: 5 x pressure range
Accuracy: ± 0.05" w.c.
Resolution: ± 0.01" w.c.
Nonlinearity: ± 0.05% FS (BFSL)
Hysteresis and Repeatability: ± 0.05% FS
Internal Thermistor Range: -40 to 158°F (-40 to 70°C)
Internal Thermistor Resolution: 0.7°F (0.4°C), R25 value equal
to 10,000 Ohm [10 KOhm @ 25° C (77° F)]
Compensated Temp Range: 32 to 158°F (0 to 70°C).
Thermal Accuracy: ± 0.5% FS.
Memory Size: 21,500 readings.
Resolution: 12 bits( 1 in 4096)
Stability: ± 0.5 % FS/yr
Sampling Methods: Continuous (First-in, First-out: not available
from 40 ms to 8 sec.), Stop when full (Fill-then-stop), or Delayed
Start.
Sampling Rates: Selectable from 0.04 seconds to 8 hours
Power: Built-in 3.6 V Lithium Battery
Power Consumption: 5 - 10 micro Amps
Clock Accuracy:
±2 sec/day plus one sampling interval
Ambient Operating Temp: -40 to 158°F (-40 to 70°C), 0 to 95% RH,
non-condensing.
Connection: Two 1/8" I.D. permanent protective tubing
Computer Requirements: IBM compatible 386 or above and Windows
(3.1 or later) with 2MB RAM and 2MB hard drive disk space, one serial
port.
Housing: Noryl™
Weight: 4 oz (110 g).
|
 |
Series
DL8 |
Process Data Logger
8-Channels, Compact, Self-Powered, Stores up to 32,768
Readings |
 |
|
Eliminate traditional paper chart recorders with the Series
DL8 Process Data Logger. This versatile, multi-channel data logger
monitors and stores up to 32,768 process readings for later download to
IBM compatible computer. Seven external input channels easily interface
with common transducer and transmitter outputs. Internal thermistor
measures ambient temperature outputs. Internal thermistor measures
ambient temperature conditions. Programming is simple and easy with the
DL200 Windows™ software and connecting cable (sold separately). The
Series DL8 Process Data Logger is ideal for monitoring temperature,
relative humidity, pressure, wind speed, current, voltage and power.
POPULAR
MODELS
Model
Number |
Input Type |
Price |
| DL8 |
0-2.5 VDC, 0-5 VDC(2 ch.), 0-10 VDC,
0-200mV DC, and 0-25mA DC(2 ch.) |
$739.00 |
| DL81 |
All channels 0 to 25mA |
$839.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
ACCESSORIES
Model
Number |
Description |
Price |
| DL200 |
Windows Software and Cable |
$159.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
No. Of Channels: Eight; One for internal thermistor and seven for
external analog inputs.
Accuracy: ± 1% of full scale.
Internal Thermistor Range: -40 to 158°F (-40 to 70°C).
Memory Size: 32,768 readings.
Sampling Methods: Continuous (First-in, First-out) or Stop when
full (Fill-then-stop).
Sampling Rates Selectable from 8 seconds to once every 5 days.
Resolution: 8 bits (1 in 256).
Power: Built-in 3.6V Lithium battery.
Power Consumption: 5-10 micro-Amps.
Clock Accuracy: ± 8 seconds per day plus one sampling interval.
Ambient Operating TEMP: -50 to 160°F (-45 to 70°C), 0 to 95% RH,
non-condensing.
Connection: Removable screw terminal.
Computer Requirements: IBM Compatible 386 or above and Windows™
3.1 or later with 2 mB RAM and 2 mB hard disk space, one serial port.
Housing: Noryl™.
Weight: 5 oz (110 g).
|
 |
Series
PD |
Pro-Data Programmable Data Logger
Measure Temperature, Humidity, Dew Point, Pressure, or
Voltage |
 |
|
Read, measure, and record temperature, humidity, dew point,
pressure, and voltage with the multifunction Series PD Pro-Data
Programmable Data Logger. The handheld measuring instrument has the
capablility to record 4000 day/time stamped samples and store data up to
40 days. The nonvolatile memory will retain recorded information in the
absence of power to be recalled later. Recorded data can be viewed on
the alphanumeric LCD display, sent directly to a printer, or transferred
to an IBM compatible computer for later analysis.
The dual channel logger uses plug-in sensors to measure the desired
parameters. Sensors are available in three different configurations -
temperature/humidity/dew point, temperature/pressure, or
temperature/voltage. All sensors are field interchangeable for
application flexibility and do not require recalibration when changed.
Unit features programmable sampling rate, selectable °F or °C, backlit
display, and rear panel keyholes for permanent mounting.
POPULAR
MODELS
Model
Number |
Sensors
Included |
Price |
| PD101 |
Temperature/Humidity/Dew Point |
$459.00 |
| PD201 |
Temperature/Pressure |
$635.00 |
| PD301 |
Temperature/Voltage |
$459.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
ACCESSORIES
Model
Number |
Description |
Price |
| PD7 |
Replacement Temperature/Humidity Sensor |
$165.00 |
| PD8 |
Replacement Pressure/Temperature Sensor |
$270.00 |
| PD9 |
Replacement Temperature/Event Sensor |
$165.00 |
| PD77 |
10 ft. Extension Cable for
Humidity/Temperature Sensor |
$25.00 |
| PD85 |
25 ft. Extension for
Pressure/Temperature/Event Sensor |
$21.00 |
*Prices are
based in US currency and may change for international customers
due to and not limited to customs brokerage fees, export packing
and documentation, tariffs, duty and taxes.
|
|
SPECIFICATIONS
Recording Time: 5 hr, 15 hr, 30 hr, 60 hr, 2 weekds, or 40 days
(field selectable).
Sampling Rates: Field selectable from 5 seconds to 15 minutes.
Memory Size: 4,000 samples.
Temperature/Humidity/Dew Point Sensor: 4" plastic temp
sensor for air only; Temp. Range: -40 to 170°F (-40 to 75°C),
Accuracy: ± 2°F (± 1°C); Humidity Range: 0 to 100% @ 32 to 130°F (0
to 55°C), Accuracy: ± 2%; Dew Point Range: 32 to 130°F (0 to 55°C).
Temperature/Pressure Sensor: 4" SS submersible temp sensor;
Temp. Range: -40 to 170°F (-40 to 75°C), Accuracy: ± 2°F (± 1°C);
Press. Range: 0 to 500 psi (0 to 35 bar), accuracy: ± 1% FS.
Temperature/Voltage Sensor: 4" SS submersible temp sensor;
Temp. Range: -40 to 170°F (-40 to 75°C), Accuracy: ± 2°F (± 1°C);
Voltage Range: 24 to 270 VAC, 24 to 180 VDC.
Display: Alphanumeric backlit LCD, 16 characters x 2 lines.
Cable Length: All are 6 ft (1.8 m).
Power: 115 VAC 50/60 Hz adapter (220 VAC available) or 9V
alkaline battery for 24 hr backup power source (not included). External
power may be supplied from any 12 VDC source.
Printer Interface: Parallel centronics compatible printer port.
Computer Requirements: IBM compatible 286 or above and MS-DOS 3.0
or later. DB25 Male-Male.
Weight: 10 oz (284 g).
|
|