LevelTransmitters
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Echotouch
Two-Wire Ultrasonic Level Transmitter LU20-50_1 |
| LU20
Ultrasonic Loop Powered Level Transmitter GP = General Purpose IS = Intrinsically Safe |
|
|---|---|
| Range: | 0.5 to 18 feet (15 cm to 5.4 m) |
| Accuracy: | ± 0.25% of span in air |
| Resolution: | 0.125" (3 mm) |
| Frequency: | 50 kHz |
| Pulse rate: | 2 pulses per second |
| Beam width: | 8' conical |
| Deadband: | 0.5' (15 cm) minimum |
| Blocking distance: | 0.5 to 18 feet (15 cm to 5.4 m) |
| Display type: | 4 segment LCD |
| Display units: | Inch (cm) |
| Memory: | Non-volatile |
| Supply voltage: | GP: 12-36 VDC IS: 12-32 VDC |
| Max loop resistance | GP: 900 Ohms @ 36 VDC IS: 900 Ohms @ 32 VDC |
| Signal output: | GP: 4-20 mA, 12-36 VDC IS: 4-20 mA, 12-32 VDC |
| Signal invert: | 4-20 mA / 20-4 mA |
| Calibration: | Push button |
| Fail-safe diagnostics: | Reverts to 4 mA, 22 mA or remains constant |
| Temperature rating: | F: -40 degrees to 140
degrees C: -40 degrees to 60 degrees |
| Temp. compensation: | Automatic over entire range |
| Pressure rating: | 30 psi (2 bar) @ 25
degrees C., derated @ 1.667 psi (0.113 bar) per degree C. above 25 degrees C. |
| Enclosure rating: | NEMA 4X (IP65) |
| Enclosure material: | Polypropylene (PP), UL94 VO |
| Transducer material: | Polyvinylidene Fluoride (PVDF) |
| Mounting threads: | 2" NPT (2" G) |
| Mounting gasket: | Viton (2") metric only |
| Conduit connection: | 1/2" NPT (1/2" BSP) |
| CE Compliance: | EN 50082-2 immunity EN 55011 emission |
| CSA Certificate: | LR79326-10 |
|
Echotouch Intrinsically Safe Ultrasonic Level Transmitter LU20-50_1-IS........................$850 |
Application |
||||
|
The two-wire, intrinsically safe ultrasonic level transmitter is mounted through the top wall of the tank and provides non-contact measurement up to 18 feet. This device is ideal for use with hazardous bulk storage tanks, process vessels and waste sumps. Approved for use in Class I, Groups A, B, C and D; Class II, Groups E, F and G; Class III; T3C environments, the transmitter is an excellent choice for use with solvent, hydrocarbon and petroleum type liquids. | |||
Specifications |
||||
| LU20
Ultrasonic Loop Powered Level Transmitter GP = General Purpose IS = Intrinsically Safe |
|
|---|---|
| Range: | 0.5 to 18 feet (15 cm to 5.4 m) |
| Accuracy: | ± 0.25% of span in air |
| Resolution: | 0.125" (3 mm) |
| Frequency: | 50 kHz |
| Pulse rate: | 2 pulses per second |
| Beam width: | 8' conical |
| Deadband: | 0.5' (15 cm) minimum |
| Blocking distance: | 0.5 to 18 feet (15 cm to 5.4 m) |
| Display type: | 4 segment LCD |
| Display units: | Inch (cm) |
| Memory: | Non-volatile |
| Supply voltage: | GP: 12-36 VDC IS: 12-32 VDC |
| Max loop resistance | GP: 900 Ohms @ 36 VDC IS: 900 Ohms @ 32 VDC |
| Signal output: | GP: 4-20 mA, 12-36 VDC IS: 4-20 mA, 12-32 VDC |
| Signal invert: | 4-20 mA / 20-4 mA |
| Calibration: | Push button |
| Fail-safe diagnostics: | Reverts to 4 mA, 22 mA or remains constant |
| Temperature rating: | F: -40 degrees to 140
degrees C: -40 degrees to 60 degrees |
| Temp. compensation: | Automatic over entire range |
| Pressure rating: | 30 psi (2 bar) @ 25
degrees C., derated @ 1.667 psi (0.113 bar) per degree C. above 25 degrees C. |
| Enclosure rating: | NEMA 4X (IP65) |
| Enclosure material: | Polypropylene (PP), UL94 VO |
| Transducer material: | Polyvinylidene Fluoride (PVDF) |
| Mounting threads: | 2" NPT (2" G) |
| Mounting gasket: | Viton (2") metric only |
| Conduit connection: | 1/2" NPT (1/2" BSP) |
| CE Compliance: | EN 50082-2 immunity EN 55011 emission |
| CSA Certificate: | LR79326-10 |
|
Symprobe
Self Grounding RF Capacitance Level Transmitter LP75-20_1-_ |
Application |
||||
|
The two-wire, self grounding capacitance level transmitter is mounted through the top wall of the tank and provides continuous measurement up to 10 feet. This device is ideal for use with general purpose intermediate storage tanks and process vessels. The transmitter is best applied in conductive, non-coating or scaling type liquids including clean water, acid and chemical solutions. The all FEP Teflon probe is an excellent choice for highly corrosive media such as hydrochloric acid. | |||
Specifications |
||||
| LP75 Symprobe Capacitance Level Transmitter | |
|---|---|
| Range: | 1 to 10' (30 cm to 3 m) |
| Accuracy: | ± 1% of full span |
| Resolution: | ± 0.125" (3 mm) |
| Conductivity range: | > 100 micro-mhos |
| Dielectric range: | > 20 constants |
| Probe pF range: | 100 to 1000 pF |
| Supply voltage: | 14-36 VDC |
| Loop resistance: | 600 ohms @ 36 VDC |
| Signal output: | 4-20 mA, 14-36 VDC |
| Signal invert: | 4-20 mA or 20-4 mA |
| Adjustments: | Potentiometer |
| Indication: | LED for power status |
| Temperature rating: | F: -40 degrees to 158
degrees C: -40 degrees to 70 degrees |
| Pressure rating: | 150 psi (10 bar) @ 25
degrees C., derated @ 1.667 psi (0.113 bar) per degree C. above 25 degrees C. |
| Probe material: | FEP Teflon® |
| Enclosure rating: | NEMA 4X (IP65) |
| Enclosure material: | Polypropylene, UL94 VO |
| Mounting threads: | 3/4" NPT (3/4" G) |
| Mounting gasket: | Viton (3/4") metric only |
| Conduit connection: | 1/2" NPT |
| CE Compliance: | EN 50082-2 immunity EN 55011 emission |
* Symprobe probe design ensures reliable grounding in plastic tanks
* Solid state sensors with no moving parts
* Loop powered design, 4-20mA output
* Easy calibration
* Operates over wide range of process liquids and viscosities
* Standard probe lengths from 18" to 120"
* PP Adjustable in-tank mounting system
* Mounts up to four sensors
* Mixer compatible with rotational velocities of up to 1.5 fps
* Optional side mount bracket conveniently mounts Smart Trak to tank wall
* Permits different sensing technologies for additional safety
* Integral controller options available
* Lengths from 2' to 20'
* Calls immediate attention to alarm conditions
* High intensity strobe light reduces operator error
* Mounts directly on Sensor Mount Controllers
* Convenient reminder to refill tank
* Available in AC or DC versions
|