The new Fluke 705 Loop Calibrator is a cost-effective, integrated solution for
calibration, repair and maintenance of current loops. It features:
mA sourcing, simulation and measurement with 0.02% accuracy and 0.001 mA
resolution
Simultaneous mA and % of span display
Selectable step or ramp outputs
Internal loop supply
For a powerful loop calibrator at a very affordable price, choose the new Fluke
705 Loop Calibrator. This feature-rich solution to loop calibration, maintenance
and repair offers:
A large display and simple, pushbutton interface for ease of use.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.02%
Push button 25% steps for fast, easy linearity checks. Save time over
traditional knob type controls.
"Span Check" for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve
slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a transmitter at the
same time without carrying a DMM.
Single 9V battery that is easily changed.
0 - 20 mA or 4 - 20 mA default start up modes.
Fluke
714 Thermocouple Calibrator Features
Measure temperature from TC output
Simulate TC output
Operable with nine types of thermocouples
Calibrate linear TC transmitter with mV source function
Selectable șF or șC
Thermocouple mini-jack termination
Available as accessories: Fluke-700TC1 and TC2 Thermocouple Mini-plug Kits
Built for the masters of
temperature.
The Fluke 724: everything you need to troubleshoot and calibrate
temperature.
Now you can carry one tool to expertly test all the temperature sensors and
transmitters in your plant.
The Fluke 724 is the masters answer to temperature calibration. The Fluke
724 can measure and source 10 thermocouple types and 7 RTD types, plus volts and
ohms.
It even handles high-speed pulsed RTD circuits and provides loop power. The
dual line measure/source display lets you source temperature and view loop
current at the same time. And with its simple, no menus controls, the
Fluke 724 is easy to operate, too.
Pricing Information
Fluke 724 Temperature Calibrator
Comes with TL75 Test Leads, AC70A Test Clips, one pair of stackable test
leads, Product Overview Manuals in English, French, German, Spanish,
Italian, Portugese, Korean, Chinese and Japanese. Users manuals on
CD-ROM; CE and CSA Markings. Price $1,295
Accessories
700RTD Secondary RTD Thermometer Probe
Precision 4-wire, 100 Ohm RTD probe for precision temperature measurement.
Ships with Cal certificate and data from -200 to 500°C.
Call For Details
800-783-6664
700TC1 Thermocouple Mini-Plug Kit
10 plugs for J, K, T, E, R/S, B or Cu, L, U, C, N types.
Price $65
700TC2 Thermocouple Mini-Plug Kit
7 plugs for J (2), K (2), T, E, R/S types.
Price $55
Fluke
715 Volt/mA Calibrator Features
Measure loop current (0-20 mA, 4-20 mA) signals with 0.025% accuracy and 1 mA
resolution
Measure voltage output process signals from PLCs, transmitters
Source or simulate 24 mA loop current
Source voltage to 100 mV or 10V
24V loop supply with simultaneous current measurement
Function Specifications
Loop Supply Range: 24 V dc
Resolution: N/A
Accuracy: +/- 10%
Note: Drive; 20 mA into 1000 W for battery >6.8V; 700 W for battery 5.8 to
6.8 V
Measure/simulate mA/% of span Range: 0 to 24 mA (-25% to 125%)
Resolution: 0.001 mA
Accuracy: 0.015% + 2 counts
Note: Sink (simulate transmitter) Display mA or % of span
Measure/simulate mV Range: 0 to 100 mV
Resolution: 0.01 mV
Accuracy: 0.02% + 2 counts
Measure/simulate V Range: 0 to 10 V
Resolution: 0.001 V
Accuracy: 0.02% + 2 counts
Fluke
725 Multifunction Process Calibrator Description
Now you can source and measure with one affordable tool.
Take along the new Fluke 725 Multifunction Process Calibrator, and you're
equipped to test and calibrate almost any process parameter. Measure and source
mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure,
using optional pressure modules.
Do you need to calibrate transmitters? The 725's split display lets you view
input and output values simultaneously. For valve and I/P tests, you can source
mA while measuring pressure. The 725 has auto-stepping and auto-ramping for
remote testing, plus 25% stepping for fast linearity tests.
From the moment you pick it up, the Fluke 725 is ready to perform. Its simple
controls, without menus, make operation easy. Its memory functions make set up
fast. And its rugged design lets it work as hard as you do.
The new Fluke 725 Multifunction Process Calibrator is a powerful, yet
easy-to-use field calibrator. Use the measure and source functions to test and
calibrate almost any process parameter.
Features
Small, streamlined shape makes it easy to carry
Rugged, reliable design stands up to field use
Easy to read measure/source screen lets you view input and output simultaneously
Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors and
transmitters
Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure
to calibrate transmitters
Measure/source pressure using any of 28 Fluke 700Pxx Pressure Modules
Source mA with simultaneous pressure measurement to conduct valve and I/P tests
Support flow meter testing with frequency and CPM functions
Perform fast linearity tests with auto _ step and auto _ ramp features
Power transmitters during test using loop supply with simultaneous mA
measurement
Store frequently used test setups for later use
Backlight lets you work in poor light
Large battery capacity of four AA cells
Battery door for easy changes
Specifications
Voltage (max load, 1 mA) 0 to 100 mV:
Resolution: 0.01 mV
Accuracy:.02% Rdg + 2 LSD
Resistance 0W to 3200W (measure):
Resolution: 0.01W to 0.1W
Accuracy: 0.10W to 1.0W
15W to 3200W (source):
Resolution: 0.01W to 0.1W
Accuracy: 0.10W to 1.0W
Frequency ** 1 CPM to 10 kHz (measure):
Resolution: 5 digits
Accuracy: 0.05% Rdg + 1 LSD
2.0 to 1000.0 CPM (source):
Resolution: 0.1 CPM
Accuracy: ±.05%
1 to 1000 Hz (source):
Resolution: 1 Hz
Accuracy: ±.05%
1.0 to 10.0 kHz (source):
Resolution: 0.1 kHz
Accuracy: ±.25%
Loop Supply 24V dc:
Resolution: N/A
Accuracy: 10%
*Temperature coefficient, -10°C to 18°C, 28°C to 55°C,±.005% of range per
°C.
**(For frequency source, waveform is 5V p-p squarewave, -0.1V offset)
Fluke
740 Series Documenting Process Calibrator Features General
The 740 Series is easy to use with flexible test strategies, user-entered
values, custom units, even a built in calculator. And like all Fluke tools, it's
rugged, reliable and tough as nails. It's like having several powerful tools in
one - so you can work faster than ever:
Calibrate temperature, pressure, voltage, current, resistance, and frequency
Measure and source with one compact, rugged, reliable tool
Create and run automated as-found/as-left procedures to satisfy quality programs
or regulations. Supports linear, square-root devices plus one-point and
two-point limit switches
Record and document results
Transfer the results to a PC (743B and 744 only), saving the time to manually
transcribe data. Run popular instrumentation management software.
HART communication capability lets you program and control HART instrumentation
(744 only)
The Fluke 740 Calibrators, offered in three models, let you choose the right set
of capabilities for your needs.
The Fluke 741B offers Simultaneous source and measure capabilities for all
common process parameters. Create and execute automated procesures and
automatically capture the results.
The Fluke 743B offers all the apability of the 741B, plus adds a serial
interface for two-way communica-management applications
The Fluke 744 offers all of the capabilities of the 743B, plus the ability to
maintain the calibrate selected HART tranmistter without a second tool.
Fluke 741B MultiFunction Process Calibrator
A complete documenting calibrator
The 741B is the economical choice for plants that don't use PCs or that require
traditional paper forms. It has storage capacity for a day's calibration and
measurement data. When you're back at the shop recall the data on screen to fill
out calibration forms.
Comes with two sets of TL24 industrial test leads, two sets of AC20 test clips,
one set of TP20 test probes, a BP7217 battery pack, a BC7217 battery charger, an
instruction manual, NIST-traceable calibration report and data, and three year
warranty.
Dimensions 130 x 236 x 61 mm
Weight 1.4 kg (3 lb 1 oz)
Internal Battery Pack NiCd, 7.2V, 1700 mAh;
Battery Life Typical usage > eight hours
Battery Replacement Via snap-shut door without opening calibrator; no tools
required
Side Port Connections Pressure module connector
Connection for optional battery eliminator
Safety Complies with CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111,
and EN610-1:1993
Data Storage Capacity 1 day of calibration results
90 Day Specifications The standard specification intervals for the 741B is 1 and
2 years. Typical 90 day measurement and source accuracy can be estimated by
dividing the one year "% of reading" or "% of output"
specifications by 2. Floor specifications, expressed as "% of f.s." or
"counts" or "ohms" remain constant.
Fluke 743B Documenting Process Calibrator
More memory, plus a PC interface and data logging
The 743B has all the capabilities of the 741B plus a PC interface that lets you
download procedures, lists, and instructions created with software-or upload
data for printing, archiving, and analysis. With its expanded memory, the 743B
can hold a full week of calibrations and procedures.
Comes with two sets of TL24 industrial test leads, two sets of AC20 test clips,
one set of TP20 test probes, a BP7217 battery pack, a BC7217 battery charger, an
instruction manual, NIST-traceable calibration report and data, and three year
warranty. Every 743B includes a serial port cable and a DPC/TRACK Sample, which
includes utilities to upload calibration data to a PC and export to PC data
files.
Dimensions 130 x 236 x 61 mm
Weight 1.4 kg (3 lb 1 oz)
Internal Battery Pack NiCd, 7.2V, 1700 mAh
Battery Life Typical usage > eight hours
Battery Replacement Via snap-shut door without opening calibrator; no tools
required
Side Port Connections Pressure module connector
RS-232 connector to interface to your PC
Connection for optional battery eliminator
Safety Complies with CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111,
and EN610-1:1993
Data Storage Capacity 1 week of calibration results
90 Day Specifications The standard specification interval for the 743B is 1 or 2
years. Typical 90 day measurement and source accuracy can be estimated by
dividing the one year "% of reading" or "% of output"
specifications by 2. Floor specifications, expressed as "% of f.s.",
"counts" or "ohms", remain constant.
Fluke
787 ProcessMeter Loop Calibrator Features
Fluke combined the DMM you trust with the loop calibrator you need.
The Fluke 787 ProcessMeterT puts a complete troubleshooting solution in the palm
of your hand. Get in touch with more information, faster and easier with the
newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you
the measurement capabilities you expect from our rugged, reliable DMMs plus the
ability to source, simulate, or measure dc current with 1 microamp resolution
and accuracy of 0.05%. Put it all together and you have the ideal tool for
troubleshooting and calibrating current loop applications. So if you're tired of
always tracking down a calibrator, lugging around two tools and switching back
and forth, get the single best solution for doubling your power. The 787
ProcessMeter from Fluke.
DMM and loop calibrator in one tool
Precision 1000V, 440 mA digital multimeter
Measure ac and dc volts, ac and dc current, resistance, continuity, and
frequency
0.1% dc voltage accuracy
0.05% dc current accuracy, 1 A resolution to 30 mA
Simultaneous mA and % of scale readout
True rms ac voltage measurement to 1 kHz
Frequency measurement to 20 kHz
Min/Max/Average/TouchHold/Relative modes
Diode test and continuity beeper
DC current source/loop calibrator
20 mA current source/simulator
Simultaneous mA and % of scale readout
Manual step (25%, coarse, fine) plus auto step and auto ramp
Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
Externally accessible battery for easy battery changes
1000V overload protection on V, ohms, frequency
150V overload protection on mA, backed-up by 440 mA 1000V fuse
Designed to meet 1000 volt IEC 1010 Cat III standards
Technical Data
DC Current Output (Internal battery operation) Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up). Over-range to
24.000 mA
Drive Capability
12 V compliance, or 500 ohms @20 mA
Accuracy (% of span)
0.05 %
DC Current Simulate (External 24 volt loop supply) Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up). Over-range to
24.000 mA
Drive Capability
1000 ohms @20 mA
Accuracy (% of span)
0.05 %
Current Adjustment Modes Range and Resolution
Manual: Coarse Fine: 25% step
Automatic: Slow Ramp, Fast Ramp, 25% step
Measurement Accuracy
VDC Range and Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Best Accuracy (% of reading + LSD):
0.1% + 1
VAC (true RMS)
to 1 kHz * Range and Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Best Accuracy (% of reading + LSD):
0.7% + 2
mA DC Range and Resolution:
30.000 mA
Best Accuracy (% of reading + LSD:
0.05% + 2
A DC Range and Resolution:
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD):
0.2% + 2
A AC Range and Resolution:
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD):
1% + 2
Resistance Range and Resolution:
400.0 Ohms, 4.000 kOhms, 40.00 kOhms, 400.0 kOhms, 4.000 MOhms, 40.00MOhms
Best Accuracy (% of reading + LSD):
0.2% + 1
Frequency (0.5 Hz to 20 kHz) Range and Resolution:
199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz
Best Accuracy (% of reading + LSD):
0.005% + 1
Diode Test Range and Resolution:
2.400 V (measures diode voltage drop)
Best Accuracy (% of reading + LSD):
2% + 1
Continuity Range and Resolution
Beeps for resistance < approx. 100 ohms
*For measurement of adjustable speed motor drive output, consider the
Fluke 39, 41 or 43 power quality analyzers.
General Specifications
Maximum voltage applied between any jack and Earth Ground 1000 V rms
Storage Temperature -40 șC to 60 șC
Operating Temperature -20 șC to 55 șC
Temperature Coefficient 0.05 x (specified accuracy) per șC (for temperatures
< 18 șC or > 28 șC)
Relative Humidity 95% up to 30 șC; 75% up to 40 șC; 45% up to 50 șC; 35% up
to 55 șC
Vibration Random, 2g, 5-500 Hz
Shock 1 meter drop test
Safety Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA
C22.2 No. 1010.1-92 Overvoltage Category III
Size 32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x 7.35 in L)
Size, with holster and Flex-Stand 52 mm H x 98 mm W x 201 mm L (2.06 in H x 3.86
in W x 7.93 in L)
Weight 369 g (13 oz); with holster and Flex-Stand 638 g (22.5 oz)
Battery Single 9V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61)
Battery Life 50 hours typical (measurement), 12 hours typical (sourcing 12 mA)
Warranty 3 years
Phone:
813-971-5001
Fax : 813-971-5117
Omni
Controls Inc.
5309 Technology Dr.
Tampa, FL 33647
Toll
Free
1-800-783-6664
Sales@Omnicontrols.com
We
guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers