FEATURES:
- The Palmer-Bowlus
constricts the flow vertically and horizontally and can be molded to
be inserted into an existing half-round pipe.
- The Parshall flumes
constrict primarily horizontally, and are design for rectangular or
trapezoidal channels.
- "H" flumes attach
to the ends of pipes where the water is free-falling.
To
Order Call 1-800-783-6664
|
|
Product
Description
Global Water offers water flumes
constructed of high quality polyester resin and fiberglass. These flumes
are durable, highly accurate, and easy to install.
Global water offers primary device flumes that constrict an open channel's
flow either horizontally or vertically or both. Once the flume flow is
backed up behind the constriction, there is a defined relationship between the
upstream water level and the open-channel flow through the constriction.
This relationship can be determined either by an equation or a look-up table.
Global Water offers three standard molded flumes: the Palmer-Bowlus Flumes,
the Parshall Flumes, and the H Flumes.
- The Palmer-Bowlus constricts the flow vertically and horizontally and can
be molded to be inserted into an existing half-round pipe. Click HERE
for Diagrams and Palmer Bowlus flume table of Dimensions.
- The Parshall flumes constrict primarily horizontally, and are design for
rectangular or trapezoidal channels. Click HERE
for Diagrams and Parshall flume table of Dimensions/Flow Data.
- H flumes attach to the ends of pipes where the water is free-falling.
Click HERE for
Diagrams and H-flume table of Dimensions.
Installation
For a flume to work properly, there must be freely flowing water out of the
flume. The flow cannot be backed up downstream or the reading will be
erroneous and misleading. Make sure that you have free-flowing water
without major inflows downstream of the flume. The open channel flow
measurement can be made by using a float in an adjacent stilling well, a pressure
transducer, or by an ultrasonic sensor.
Options
& Prices
Contact
Global Water directly to obtain a quote for the following flumes:
- The Palmer-Bowlus constricts the flow vertically and horizontally and can
be molded to be inserted into an existing half-round pipe. Click HERE
for Diagrams and Palmer Bowlus flume table of Dimensions.
- The Parshall flumes constrict primarily horizontally, and are design for
rectangular or trapezoidal channels. Click HERE
for Diagrams and Parshall flume table of Dimensions/Flow Data.
- H flumes attach to the ends of pipes where the water is free-falling.
Click HERE for
Diagrams and H-flume table of Dimensions.
We recommend using the Water
Level Logger Flume and Weir Option with Global Water flumes.
|