Scott/Bacharach
|
SensorStik®
The Series 4500 Sensor Stik® is a field-proven in thousands of
applications world-wide providing single- and multi-point toxic gas
monitoring in a spectrum of applications.
Sensorstik is two-wire loop-powered and intrinsically-safe. Its small
footprint and ease of use have made it a leader in its field for years.
FEATURES:
• Easy-To-Use
• Intuitive user interface. 3 digit
LCD provides local display of concentration
• Rugged Design with
Fully-encapsulated, spun RESDEL epoxy enclosure
• EMI/RFI resistance
• 5 year transmitter warranty
• Patented no-pins sensor connector
• Non-intrusive zero and span
adjustment
• Small Footprint
• Intrinsically Safe
|
| Product
Specifications |
| Portable: |
No |
| Detects: |
Ammonia, Arsine, Boron Trichloride, Boron TriFluoride,
Bromine, Carbon Monoxide, Chlorine, Chlorine Dioxide, Diborane,
Dichlorosilane, Fluorine, Germane, Hydrides, Hydrogen, Hydrogen
Chloride, Hydrogen Cyanide, Hydrogen Fluoride, Hydrogen Selenide,
Hydrogen Sulfide, Methyl Mercaptan, Methylene Chloride, Nitric
Oxide, Nitrogen Dioxide, Nitrogen Trifluoride, Oxygen, Ozone,
Phosgene, Phosphine, Silane, Silicon Tetrafluoride, Sulfur
Dioxide, TEOS, Tungsten Hexafluoride |
| Technology: |
Electrochemical |
| Instrument Type: |
Toxic |
| Datasheets: |
4500
SensorStik
File Size: 427 kb Approx. Download Time on 56k
connection: 59 sec.
|
|
4700
TWISTIK
|
| All the same great features as the Sensor
Stik but the TWISTIK provides some additional maintenance-saving
features. The instrument can be calibrated either in place or off-site.
A built-in lithium battery keeps the transmitter continuously under
power while an innovative twist-lock connector enables users to quickly
remove the transmitter for off-site maintenance. This battery also
enables the TWISTIK to be installed without the typical warm-up time.
Built-in recharging circuitry quickly restores the battery to its
standard two-week lifetime.
Features:
- Easy-To-Use
- Intuitive user interface. 3 digit LCD provides local display of
concentration.
- Rugged Design with fully-encapsulated RESDEL epoxy enclosure
- EMI/RFI resistance.
- 5 year transmitter warranty.
- Patented no-pins sensor connector
- Non-intrusive zero and span adjustment
- Small Footprint
- Intrinsically Safe
|
|
|
GasPlus® Universal Toxic Gas Transmitter
The Series 4600 GasPLUS® is a toxic gas and oxygen transmitter designed
for single and multi-point monitoring applications where ruggedness,
flexibility, and ease of maintenance are critical.
The basic Series 4600 transmitter is a two-wire device providing a
4-20 mA output. For additional output flexibility, Series 4600 MB
transmitters offer RS-485/232 MODBUS® RTU output and relay contacts in
a multi-wire configuration.
FEATURES:
• Local display
• Non-intrusive calibration
• No sensor warm-up time
• Remote sensor maintenance
• Sensor removal without the need to
declassify the area
• Sensor end-of-life indicator
• Missing sensor indicator
• Horizontal conduit entries
4600MB ADDITIONAL FEATURES:
• Optional built-in alarm relays
• RS-485/232 MODBUS® RTU output
• Security lockout
`
APPROVALS:
4600): ETL & UL/C-UL Class I,Division 1,Groups
B,C,D (4600MB)Class 1/Div1/Groups B,C,&D
|
| Product
Specifications |
| Portable: |
No |
| Detects: |
Ammonia, Arsine, Boron Trichloride, Bromine, Carbon Monoxide,
Chlorine, Chlorine Dioxide, Diborane, Dichlorosilane, Fluorine,
Germane, Hydrogen, Hydrogen Chloride, Hydrogen Cyanide, Hydrogen
Fluoride, Hydrogen Selenide, Hydrogen Sulfide, Methanol,
Methylene Chloride, MethylIodide, Nitric Oxide, Nitrogen
Dioxide, Nitrogen Trifluoride, Oxygen, Ozone, Phosphine, Silane,
Sulfur Dioxide, TEOS |
| Technology: |
Electrochemical |
| Instrument Type: |
Toxic |
| Datasheets: |
4600
GasPlus Universal Toxic Gas Transmitter
File Size: 150 kb Approx. Download Time on 56k
connection: 20 sec.
|
|
|
GasPlus-IR® Carbon Dioxide Gas Transmitter
The Model 4679 IR is a rugged, reliable solution for carbon dioxide
gas detection. Designed with extensive user input, the instrument is
extremely flexible, easy to use, and easy to maintain.
IR technology provides numerous
advantages that may be benificial for your application’s conditions:
• Reduced maintenance (no span
calibration required).
• No saturation from high gas
concentrations
• No oxygen required for operation
• Continuous sensor fault monitoring
• Sensor lifetime not reduced by
exposure to gas
• Rapid speed of response
• Minimal temperature and humidity
effects
`
FEATURES:
• Low Maintenance
• No span calibration required
• Zero adjustment a quick,
non-intrusive procedure
• Many user adjustable parameters
• Rugged Design with nickel plated
optics component protection
• Multiple Output Choices 4-20mA and RS/485 (Modbus protocol)
outputs. Relays with user adjustable set/reset points, and time delays
are available as an option.
|
| Product
Specifications |
| Portable: |
No |
| Detects: |
Carbon Dioxide |
| Technology: |
Infrared |
| Instrument Type: |
Toxic |
| Datasheets: |
4679-IR
GasPlus Carbon Dioxide Gas Transmitter
File Size: 518 kb Approx. Download Time on 56k
connection: 1 min. 12 sec.
|
|
Sentinel® Infrared Combustible
Gas Detection Transmitter

Detection of Combustible Gas Using Infrared (IR) Sensor Technology.
This IR Combustible Gas Transmitter provides a very stable and low maintenance measurement
of the Lower Flammability Limit (LFL); and is a lower "cost of ownership"
alternative to conventional catalytic design gas detectors. A folded path, dual detector
scheme in standard size packaging offers replacement for conventional catalytic design gas
detection transmitters.
It is ideal in tough applications where poisons, frequent releases, or limited access
make catalytic technology difficult to maintain.
Features:
- Cannot be "poisoned"
- Doesn't require Oxygen
- Once a year calibration
- Switch selectable linearizations
- Over five year detector operating life
- Five year detector life
- Nonintrusive calibration via magnetic wand
Condensed Specifications
- Housing: NEMA 4, Epoxy painted steel.
- Power: 10 to 30 Volts DC, 3.6 Watts Max.
- Output: 4-20 mA into 100 Ohms Max. at 24 VDC.
- Detector: Infrared dual-wavelength type. 2-year warranted life,
5 years typical.
- Displays: Yellow blinking power LED, Red Fail/Calibration Mode LED, Optional 2 Digit LCD
Display of Percent LFL with Mode Indication.
- Hazardous Areas: Class 1, Division I, Groups B, C & D.
- Approvals: CE, CSA, UL and CENELEC
Condensed Ordering Information
| Part Number |
Description |
51-7456 |
0-100% LFL, nondisplay Infrared combustible transmitter
(diffusion)
|
51-7472 |
0-100% LFL, display Infrared combustible transmitter
(diffusion)
|
4888
NIC II Combustible Gas Transmitters
|
| With its field proven catalytic bead
technology, excellent zero stability, and a low maintenance design, the
NIC II transmitter offers a rugged, economical solution for combustible
gas detection. NIC II features non-intrusive calibration (via magnet) ,
a LCD display, optional local relays, and is available in diffusion,
duct mount, and sample draw configurations.
Features:
- Non-Intrusive Calibration
- Auto-Inhibit
- Simple User Interface
- Stand-Alone Capable
- Easy-To-Maintain
- Easy-To-Install
- Either 4-20 mA or MODBUS RS-485 outputs and optional integral
relays.
|
|
Download Data Sheet
4688-IR
GasPlus Combustible
|
| The Model 4688 IR is a rugged, reliable
solution for hydrocarbon gas detection. Designed with extensive user
input, the instrument is extremely flexible, easy to use, and easy to
maintain. The GASPLUS IR is suitable for most applications where
catalytic bead detectors are currently used - as well as some
applications where catalytic sensors won’t work.
Features:
- Low Maintenance
- No span calibration required
- Zero adjustment a quick, non-intrusive procedure
- Flexible, many parameters are user-adjustable, including gas to be
detected, decimal precision, damping, and engineering units.
- Rugged Design with conformally coated electronics, nickel plated
optics component protection
- Extensive Self Diagnostics with detailed fault codes aid in
troubleshooting
- Multiple Output Choices 4-20mA and RS/485 (Modbus protocol)
outputs. Relays with user adjustable set/reset points, and time
delays are available as an option.
- User-Friendly Display
- Low Cost of Ownership
|
|
Download Data Sheet
|
SafEye® Open Path Gas Transmitters
SafEye's unique,patented “Flash Type” light source provides for an
alignment tolerance of ±1° in all directions and is protected
against false gas reading and alarms due to partial beam blockage.
Unlike traditional open path systems, SafEye is immune to the false
alarms experienced by traditional open path systems that are caused by
responses to direct or reflected radiation from sunlight, flares,
illumination and other “black body” radiation sources. |
| Product
Specifications |
| Portable: |
No |
| Detects: |
Ammonia, Combustible, Hydrocarbon Combustible |
| Technology: |
Open Path |
| Instrument Type: |
Combustible, Toxic |
| Datasheets: |
SafEye®
Open Path Gas Transmitters
File Size: 394 kb Approx. Download Time on 56k
connection: 54 sec.
|
|
Monitors
|
Sentinel Area Monitor
The Gas Sentinel Area Monitor provides an excellent solution to one
or two-point continuous toxic, oxygen deficiency, and combustible gas
monitoring for commercial, municipal, and industrial locations.
FEATURES:
• Flexible Sensor Configuration
• Permits connection to any Scott
Instruments transmitter.
• Hazardous Location Installation
• Control unit suitable for Class I,
Div 2, Groups B,C,D
• FM & CSA Approved
• Multiple Outputs
• Discrete Alarm Relays
• Three SPDT relays per channel
• Local Horn
|
| Product
Specifications |
| Portable: |
No |
| Detects: |
|
| Technology: |
|
| Instrument Type: |
Receivers, System/Area Monitors |
| Datasheets: |
Sentinel
Area Monitor
File Size: 289 kb Approx. Download Time on 56k
connection: 40 sec.
|
|
|
Tox-Alarm® 1 or 2 Point Gas Monitor
The Series 5300 Tox Alarm Dual-Gas is an economical,
self-contained, one or two-point toxic gas monitoring system. Designed
to be easy to install, easy to operate, and easy to maintain, the
instrument requires no additional hardware or wiring.
FEATURES:
• Single or dual channel
• Built-in alarm horn and warning
lights
• Three on-board relays per channel
• Up to 3,000 feet sensoralarm
module separation possible.
• Line powered (70-270 VAC) - no
additional wiring required.
• Optional gell-cell battery backup.
|
| Product
Specifications |
| Portable: |
No |
| Detects: |
Ammonia, Arsine, Boron Trichloride, Bromine, Carbon
Monoxide, Chlorine, Chlorine Dioxide, Diborane, Dichlorosilane,
Fluorine, Germane, Hydrogen, Hydrogen Chloride, Hydrogen
Cyanide, Hydrogen Fluoride, Hydrogen Selenide, Hydrogen
Sulfide, Nitric Oxide, Nitrogen Dioxide, Oxygen, Ozone,
Phosphine, Silane, Sulfur Dioxide |
| Technology: |
|
| Instrument Type: |
System/Area Monitors |
| Datasheets: |
5300
Monitor
File Size: 589 kb Approx. Download Time on 56k
connection: 1 min. 22 sec.
|
|
6200
Single Channel Receiver
|
| The Series 6200 single channel receiver
provides a three-digit LED display of gas concentration, plus LED low
alarm, high alarm, and fail indicators. Front-panel pushbuttons enable
users to set alarm levels and reset alarms. An internal switch allows
alarm outputs to be inhibited for periodic system calibration and
adjustment.
Receivers are available in both panel-mount and wall-mount
configurations. The 24VDC-powered panel-mount configuration is housed in
a compact NEMA 1 enclosure, and provides common low alarm, high alarm,
horn, and fail open collector outputs. Housed in a NEMA 4x enclosure,
the wall-mount configuration provides a 110VAC (optional 220VAC) power
supply and relays for these open collector outputs. A front-panel
pushbutton on both versions enables users to reset alarms. The single
channel receiver also provides 0-1VDC or 0-10VDC analog concentration
output.
Features:
- Intuitive front-panel controls. with Easy-to-read LED
- Alarm inhibit switch.
- Panel-mount or wall-mount configurations.
- User-selectable latching/non-latching relay modes on high alarm.
- Accepts any 4-20mA 2-, 3-, and 4-wire gas transmitters.
|
|
Download Data Sheet
|
6800 Multichannel Receiver
The Series 6800 provides centralized display/alarming capabilites
and loop power for up to 16 EIT gas transmitters and other 4-20mA
instruments.
The Multichannel Rack Receiver is designed in 8-channel
“blocks” consisting of up to four 2-channel receiver modules and a
power supply module. The Series 6800 is available in 8-channel (9”
half rack) or 16-channel (18” full rack) versions depending on the
number of transmitters which will be used.
Each channel has a numeric and bar-graph LCD concentration display,
LED alarm indicators (3 alarm and one fail), and a slide-in
identification tag. Channel settings are configured by the plug-in
hand-held programmer —
FEATURES:
• Individual display of 2-16
channels -- expandable to meet your changing needs
• Centralized program memory --
allows replacement of channel cards "on the fly" without
losing alarm setpoint data
• 3 relays per channel and built-in
horn -- local and remote alarming
• Line-powered, with built-in loop power supply -- powers all
transmitters attached
|
| Product
Specifications |
| Portable: |
No |
| Detects: |
|
| Technology: |
|
| Instrument Type: |
Receivers |
| Datasheets: |
6800
Multichannel Receiver
File Size: 196 kb Approx. Download Time on 56k
connection: 27 sec.
|
|
Download Data Sheet
|