CURRENT TRANSDUCERS Electronic DCT DIN RAIL mount current transducers
DCTR True RMS
Measuring DIN RAIL mount current transducers NEW
Our most popular current transducers. Select the ACT where a UL listed product is required. Many panel builders and contractors use these where an analog signal proportional to AC current is required.
MCT5 Series DIN Rail Mount Series Same as CT5 in 1 inch thick DIN Rail-mount case.
SCT Series Split Core Current Transducers
Split-core transformer and electronics in the same easy to use case. Available now. Request product bulletin.
CTD Series — standard and large aperture
Similar to CT5 described in the above.
CTR True RMS Measuring Current Transducers
These current transducers provide a highly accurate analog output proportional to the RMS value of the current input. Use these true RMS measuring trans-ducers when harmonic content or distortion exists.
CT7 Series Low Current DC
CT8 Series Low Current True RMS Measuring
VT7 Series Shunt Isolators For use with existing millivolt shunts. These amplify the voltage drop across the shunt and provide an isolated, analog output proportional to the millivolt input.
VT8 Series Shunt Isolator For use with existing millivolt shunts. These provide an isolated DC analog output proportional to the RMS value of the input. Not in catalog — ask.
CURRENT TRANSDUCERS Hall Effect CTL
Series Open Loop Current Transducers Wide range of transducers available for monitoring 35 to 40,000 amperes. These high quality Hall Effect current transducers are used for monitoring DC or AC current. They are frequently used to monitor torque delivered by DC motors.
CTF and
CTFB Series Closed
Loop Precise, electronic Hall effect current transducers are ideal for monitoring DC, AC, pulse current, and variable frequency current. These closed loop or feedback style hall effect current transducers provide 0.1% linearity.
CTG Open
Loop High output Series High output, low excitation current Hall effect current transducers built for special applications.
CTA Series Signal Conditioners Signal conditioners are available for the CTL and the CTF series of Hall effect current transducers. Both instantaneous and true rms measuring signal conditioners are available.
CURRENT TRANSFORMERS CTX Split Core Current Transformer These highly linear split core current transformers are used with several OSI transducers and instruments including: DM2 Demand Meter, DLM Digital Load Monitor, WL40R watt-hour transducers, and the CTR true rms measuring currenttransducers.
DVT DIN RAIL mount voltage transducers NEW
DVTR
DIN RAIL mount true RMS measuring voltage transducers
VT & AVT
Series
MVT Series Same as the VT series above but in a 1 inch thick DIN Rail mount package.
VTR Series True RMS Measuring
VT7 Series
Use for monitoring DC voltage where isolation is required. Provides instantaneous output proportional to the input. Works on AC or DC. If DC input, then DC output. If AC input, then AC output. If you plan to use the VT7 on AC, then use the peak value of the AC voltage for the voltage rating on the VT7.
VT8 Series
True RMS Measuring Used for monitoring AC voltage where the frequency range is outside that which a transformer can handle. These provide very fast transient response.
DW5 DIN RAIL mount watt transducers NEW
GW5 and AGW Series Watt Transducers These are a high accuracy, electronic watt transducer. Use where high accuracy power readings are required. Applications include utility monitoring, power control, and power monitoring over a wide dynamic range.
PC5 & PC4 Series Long a standard of excellence from Ohio Semitronics, Inc. Many of these Hall effect watt transducers have been in continuous use for twenty years or more and are still performing within their accuracy rating. The PC5 watt transducers are highly recommended for use where frequency stability is lacking, high harmonics are present, or chopped current wave shapes exist. Recommended for monitoring loads controlled by phase angle-fired SCR controllers.
PC8 Series These DC to 400 hertz watt transducers are used world wide for monitoring DC power.
Designed specifically for variable frequency applications either single phase or polyphase.
MT Series Multipliers The MT series multipliers are designed to utilize existing signals that are proportional to the actual current and voltage delivered to a load. A typical application is in systems where shunts and perhaps voltage transducers are already in place.
High accuracy combination watt and watt-hour transducer may be used for tariff purposes, control, energy management, or as a sensor in a control system. The AGH is UL Listed.
Based on our PC5 series watt transducer and VFC integrators, these watt-hour transducers provide outputs for watts and watt-hours. Applications are similar to those listed for the PC5 series watt transducers.
SWH Series Split core integrated current transformer / watt-hour transducer in the same case.
WL Series These inexpensive watt-hour transducers provide excellent accuracy. The flat pack design and low cost has made this series very popular with energy management and sub-metering companies.
High accuracy, electronic transducer used where precision is required. Applications include power factor control and reactive power monitoring over a wide dynamic range.
These are available for three phase applications only . The GV5 series described above is the preferred series. Use the VAR5 series where frequency regulation is poor or distorted wave shapes exist. Please consult factory before specifying the VAR5 transducers.
VGH Series
The PTB board level transducer with multiple outputs has become very popular. The DSP digital transducer has also been gaining in popularity. DMT Series of DIN Rail Mount Multifunction Programmable Transducers.
DSP Digital Signal Processing Transducer Highly accurate electronic transducer provides RS-422 interface that communicates value of true rms current and true rms voltage for each phase, power for each phase and total power, and frequency. Connect direct to RS-422 board in computer or use RS-422 to RS-232 adapter and go straight into COM port on PC.
PTB Board Level Transducer Series Board level transducer provides analog output signals proportional to voltage, current, power, VA, power factor and pulses for watt-hours. This is a very economical choice where multiple analog signals are required.
PC20 Series of watt, VA, Power Factor Transducers Popular PC20 series provides analog outputs proportional to power, apparent power, and power factor where power factor is determined from the ratio or power to apparent power. In this way, the power factor output is linear with power factor and not phase angle.
GWV5 Series Watt and VAR Transducer These are a high accuracy combination watt and VAR transducer. Use wherever both watt and VAR readings are required.
WVL Series Watt-hour and VAR-hour Transducer Inexpensive series of watt-hour and VAR-hour transducers provide excellent accuracy. Easy to mount board level design coupled with low cost make these popular with energy management companies.
DPA Phase Angle Transducers
Use this transducer to measure the phase angle difference between a current input and voltage input. The output is linear with the phase angle shift.
PF5 Series
The PF5 series power factor (Phase Angle) transducers provide an analog output directly proportional to the phase angle shift between voltage and current. Models are available for single or three phase circuits. See Multiple Output Transducers for true Power Factor Transducers.
DPF Power Factor Transducer
Frequency transducers provide an analog output proportional to frequency. DFD Differential Frequency Transducer
Use this series for comparing frequencies of two different power systems.
DFT narrow range Frequency Transducers Use this series for measuring standard power frequencies.
DFTA Wide Frequency Range Frequency Transducers
Use this series for measuring frequency over a wide range such as 10 to 1000 Hertz.
AFT UL and CUL Listed
FTA Series
Integrators accept an analog input signal and integrate that signal with respect to time. They provide a pulse or relay contact closure output where each pulse represents so much integrated quantity — watt-hours or ampere-hours. VFC Series
Process accumulator will accept analog signal and provide an eight digit reading of the accumulated time integrated quantity.
Signal conditioners are used to convert one type of analog signal to another. For example a signal conditioner accepts a 0 to 1 mADC input and provides a 4 to 20 mADC output. SG and MSG Process Signal Conditioners The SG and MSG series of signal conditioners provide an isolated analog signal output proportional to the analog input. The SG’s are in our standard metal can while the MSG’s are in a 1 inch thick DIN Rail mount plastic case.
SCE Signal Converters The SCE signal converters accept a low level DC voltage or current and convert it to a 4 to 20 mADC signal. These do not provide isolation.
LRB Precision Load Resistors Use these precision load resistors to convert a low-level analog current signal to a voltage signal.
PI Low Level Converter Converts 4 to 20 mADC to either a 0 to 1 volt or a 0 to 1 mADC signal.
Accepts 0 to 1 mADC or 0 to 10-volt DC input.
CRD-020 Programmable Set Point Relay Accepts AC current input.
INSTRUMENTATIONLOAD MONITORSDLM Digital Load Monitors
DEMAND METER DM2 Demand Meter
WATT AND WATT-HOUR METERS WH50 Series of Watt-hour Meters Electronic watt and watt-hour meter offers many options and highly accurate measurement of power and energy.
WH30 Watt and Watt-hour Meters Long a standard of excellence from Ohio Semitronics, Inc. These Hall effect watt and watt-hour meters have been performing for decades at industrial sites.
WH70 Series DC Watt and Watt-hour Meters Long a standard of excellence from Ohio Semitronics, Inc. These Hall effect watt and watt-hour meters have been performing for decades at industrial sites.
AMPERE HOUR METER AH70 Ampere Hour Meters Uses for the AH70 series ampere hour meters include monitoring electrolytic operations as found in copper mines or plating operations, battery monitoring, mine operations (determining DC motor torque and operator efficiency), and appliance testing.
OPTIONS FOR WH AND AH METERS Options Available for WH and AH Series Instruments
RESALE ITEMS Current Transformers In addition to the current transformers manufactured by Ohio Semitronics, Inc., OSI carries a complete line of solid and split core transformers. Most of these transformers are UL and CUL Recognized.
OSI carries a small selection of panel meters that may be used with OSI transducers.
These are for use with OSI watt-hour transducers or the VFC integrators.
Allows user to safely install or remove transducers or meters in the current transformer circuit.
|
* True Power Measurement
* DC to 400 Hertz
* Non-contact & split-core
* Non-sinusoidal waveforms
* 56 models
* Input: Voltage: 0 to 25V thru 600V; Current: 0 to 5 thru 2000A
* Output: 1mA, 4-20 mA, 5V, 10V
* Accuracy ±1.0% F.S.
* Power Factor Measurement
* Volt Amp Measurement
* True Power Measurement1 phase
* 50-400 Hertz
* 32 models
* Input: AC Voltage 150, 300, 600; AC Current: 1, 5, 10, 20
* Outputs: W, VA & PF; 4-20mA, 5V, 10V
* Accuracy ±0.25% F.S.
* High Accuracy
* True Power Measurement
* Analog "Watts"
* Relay Closure "WH"
* 26 models
* UL models available
* Input: AC Voltage: 150, 300, 600; AC Current: 5, 10, 20
* Output: Analog: 1mA, 5V, 10V, 4-20mA; Relay: 1 watthour per count
* Accuracy: ±0.2% of reading
* True Power Measurement
* 48 to 70 Hertz
* Used in SCR Phase Fired Circuit
* Supplied and calibrated with current transformers
* 83 models
* Input: AC Voltage: 150, 300, 600; AC Current: 0-1A thru 2000A
* Output: 1mA, 4-20mA, 5V, 10V
* Accuracy: ±0.5% F.S.
* High Accuracy
* True Power Measurement
* 25 models
* Input: AC Voltage: 150, 300, 600; AC Current: 5, 10, 20
* Output: 1 mA, 4-20mA, 5V, 10V
* Accuracy: ±0.2% of reading
* 60 degrees leading and lagging
* Phase angle measurement
* 18 models
* Input: AC Voltage: 95-135, 205-300, 410-550; AC Current: 0 to 5, 10, 20
Phase: 1 phase 2-wire, 3 phase 3-wire, 3 phase 4-wire
* Output ±1mA, ±10V, 4-20mA, 20mA
* Accuracy ±0.5% F.S.
* Low cost, 50-400 Hz
* Calibrated with current transformers
* Input: AC Current 0-1A thru 0-2000 Amps
* Output: 1mA or 4-20mA
* Accuracy: 1 thru 20 Amps ±0.25% F.S.; 25A and Up ±0.5% F.S.
* Low cost, non contact, all in one package
* Input: AC Current 0 to 25A thru 0 to 1000A
* Output: 1mA or 4-20mA loop-powered
* Accuracy: ±0.5% F.S., Option J ±0.25% F.S.
* True RMS Measurement
* 50-400 Hertz
* 0.25%
* Input: AC Current 0 to 1 thru 0 to 20 Amps
* Output: 1mA, 5V, 10V, 4-20mA
* Accuracy: ±0.25% F.S.
* Low cost, 50-400 Hertz
* Input: AC Voltage 0-150, 300, 600
* Output: 1mA or 4-20mA
* Accuracy: ±0.5% F.S.
* Dip switch select current range
* Push button set point
* LED Threshold indication
* Over or under current
* Input: AC Current 0-5, 10, 15, 20
* Output - Form C SPDT 120V, 3A
* Accuracy : ±1%
* Set Point: 01 to 99 percent
* True RMS Measurements 50-400 Hertz
* Input: AC Voltage 0-150, 300, 600
* Output: 1mA, 5V, 10V, 4-20mA
* Accuracy: ±0.25% F.S.
* 1500V Isolation, High common mode
* Input: Voltage 50mV, 100mV, 200mV, 250mV thru 1000V
* Output: 1mA, 4-20mA, 5V, 10V
* Accuracy: ±0.5% F.S.
* 1000V Isolation, 72 Input/Output Combinations
* Input: 0-1mA, 20mA, 4-20mA, 10-50mA, 20-4mA, 0-5V, 10V, 1-5V
* Output: 0-1mA, 20mA, 4-20mA, 4-12-20mA, 0-5V, 10V, 1-5V
* Accuracy: ±0.25% F.S.
* High accuracy, analog output
* Input: Frequency 45-55, 55-65, 375-425 Hertz
* Voltage 95-135VAC
* Output: 5V, 10V, 1mA, 4-20mA
* Accuracy: ±0.05 Hertz 50/60 Hertz; ±0.2 Hertz 400 Hertz
Other Tranducers
![]() |
|