Water Quality Sensors


The Global Water Quality Sensors are rugged, industrial grade sensors designed for direct immersion or insertion into water streams.  Most sensors are powered by 10 to 36VDC and all sensors have a linear 4-20mA output.  25' cable lengths are standard with optional cable lengths to 500'.

Scroll to:
Download Files
Temperature Sensor
pH Sensor
Conductivity
Dissolved Oxygen Sensor
ORP/Redux Sensor
Turbidity Sensor
Prices

Download PDF Files:
Water Quality Sensor's Manual

Downloading the manual may take several minutes depending on your connection speed.
To view the manual your computer must have Adobe® Acrobat® Reader™ Version 4.0 or later.

Temperature Sensor WQ101

Output: 4-20 mA
Range: -50°C to +50°C
Accuracy: ±0.2° or ±0.1°C
Operating Voltage: 10-36 VDC
Current Draw: Same as sensor output
Warm Up Time: 5 seconds minimum
Operating Temperature: -50° to +100°C
Size of Probe: 3/4" diameter x 4 1/2" long
Weight: 1/2 lb.

Temperature Sensor Brochure

View Pricing information


pH Sensor WQ201

Output: 4-20 mA
Range: 0-14 pH
Accuracy: 2% of full scale
Operating Voltage: 10-36 VDC
Curren Draw: 5.5 mA plus sensor output
Warm Up Time: 3 seconds minimum
Operating Temperature: -5° to +55°C
Pressure Rating: 0-100 psi
Size of Probe: 1 1/4" diameter x 10" long
Weight: 1 lb.

pH Sensor Brochure

View Pricing information


Conductivity Sensor WQ301

Output: 4-20 mA
Range: 0-5,000, 0-10,000, 0-20,000 Micro Siemens (micro mhos) per cm
Accuracy: 1% of full scale
Operating Voltage: 12VDC (± 5%)
Current Draw: 0.8 mA plus sensor output
Warm Up Time: 3 seconds minimum
Operating Temperature: -40° to +55°C
Size of Probe: 1" diameter x 10 1/2" long
Weight: 1 lb.

Temperature Compensation: 2% per °C
Electrodes: 316 Stainless Steel
Conductivity Sensor Brochure

View Pricing information


Dissolved Oxygen Sensor WQ401

Output: 4-20 mA
Range: 0-100% Saturation, 0-8 ppm, temperature compensated to 25°C
Accuracy: ±0.5% of full scale
Operating Voltage: 10-36 VDC
Current Draw: 15.5 mA plus sensor output
Warm Up Time: 10 seconds minimum
Operating Temperature: -40° to +55°C
Size of Probe: 1 1/4" diameter x 11" long
Weight: 1 lb.

Membrane: 0.001 FEP Teflon (standard)
Combined Error: 2% FS
Dissolved Oxygen Sensor Brochure

View Pricing information


ORP/Redux Sensor WQ600

Output: 4-20 mA
Range: -500 to +500mV
Accuracy: 2% of full scale
Operating Voltage: 10-36VDC
Current Draw: 0.2 mA plus sensor output
Warm Up Time: 3 seconds minimum
Operating Temperature: -40° to +55°C
Size: 1" diameter x 10 1/2" long
Weight: 1 lb.

ORP/Redux Sensor Brochure

View Pricing information


Options and Prices

WQ101 Temperature Sensor...............$235
WQ201 pH Sensor.............................$460
WQ301 Conductivity Sensor................$520
Specify Sensor Range:  0-5,000, 0-10,000, 0-20,000 Micro Siemens (micro mhos)
WQ401 Dissolved Oxygen Sensor.......$635
WQ600 ORP/Redux Sensor................$465
WQEXC Extra Cable...........................$1.10/ft

WQ710 Turbidity Sensor......................$850

WQ770 Turbidity Meter........................$1095

WQ800 Multiparameter probe...................$2100
Measures pH, dissolved oxygen, temperature, and conductivity.

EZ100  Optional Sensor Display......................additional $295

 


Phone: 813-971-5001
Fax : 813-971-5117

Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Toll Free
1-800-783-6664

email sales@omnicontrols.com
Sales@Omnicontrols.com

We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers

 


Please Note: All prices subject to change without notice
copyright©omnicontrols.com - All Rights Reserved.
Terms and Conditions for Omni Controls Inc - online.
Legal Disclaimer
Supplementary Information and Cover Art Copyright omnicontrols.com. All rights reserved.

copyright © omnicontrols 2005
Omni Controls Inc.
5309 Technology Dr.
Tampa, FL 33647

Email: sales@omnicontrols.com

Phone: 800-783-6664
Fax: 813-971-5117