PASVE is a
ball-type mounting & service valve for HG and LEV/PRESS-EL PG/PGS type level and
pressure transmitters. PASVE makes it simple to disconnect the transmitter from the
process for maintenance and cleaning, without stopping the process or draining the tank.
PASVE is available in a manually operated type or equipped
with a pneumatic actuator.
Max. operating
pressure/temperature
Pressure 40 bar, temperature 250 °C,
(see the appended table).
Min. operating temp. -50 °C.
PVDF: See the appended table.
Materials
Wetted parts: AISI316L, for F type also
Titanium and PVDF. Seals PTFE or
PTFE with carbon and graphite filling.
Weight
PASVE GC 4.3 kg, PASVE GP 4.2 kg,
PASVE GF 8.4 kg, Actuator 5.5 kg
PASVE pH is a mounting/service valve
for pH sensors. It can be used with practically all ...
PASVE pH is a
mounting/service valve for pH sensors. It can be used with practically all pH sensors in
this size category.
PASVE pH allows the cleaning and calibration of pH sensors
without stopping the process. When required, this can be done automatically. To protect
the sensor in abrasive processes, it can be turned to the measuring position only for the
duration of the actual measurement
PASVE pH is available in a manually operated type or
equipped with a pneumatic or electric actuator.
SPECIFICATIONS:
Applicable pH sensors
refer to the Selection Table.
Max. operating
pressure/temperature
40 bar, 250 °C, /see the appended
table). Min. operating temp. -50 °C.
Sensor-specific limitations should also
be taken into account in applications.
Materials
Wetted parts: AISI316L, for type F
also Titanium, Hastelloy276 and PVDF
and for types T and D Titanium.
Seals: PTFE, or PTFE with carbon and
graphite filling.
Weight
PASVE pHC 4.7 kg, PASVE pHP 4.8 kg
PASVE pHF 8.9 kg,
Actuator 5.5 kg
The PASVE SC is
a miniature ball valve which readily accepts commercially available septum hygienic
rubbers. The PASVE SC provides you with the opportunity of taking hygienic samples from
your process without interrupting the process. The PASVE SC can be used in any industrial
process where it is necessary obtain a sample from the process which is not influenced or
contaminated from any outside disturbances.
The PASVE SC is a member of the Satron Pasve
Series, which is commonly used with pH probes, oxygen sensors and Satron's high precision
patented pressure and level transmitters.
SPECIFICATIONS:
Material
Housing: AISI316L
Gasket: PTFE seal
Max. process pressure: 10 bar (150 psi)
(subject to type of rubber septum selected)
Max. process temperature: 120 °C (250 °F)
(subject to type of rubber septum selected)
OPERATION
Position of taking
a sample
PROCESS
Taking a sample
Changing
the rubber septum
MOUNTING OF PASVE SC
1. Make a hole of 40 mm (1.6") for the valve
2. Open the locking screw
3. Remove the ball and gasket
4. Weld the frame using small rod (multiple seams)
5. Assemble the gasket and ball
6. Tighten the gasket (Do not use any tools)
7. Tighten the locking screw
MOUNTING COUPLINGS
for Levec transmitters
Prices - Please call 800-783-6664(Omni)
Thread couplings
STANDARD COUPLING G1
Order numbers :
AISI316L M546197
Hastelloy -C M5461973
Titanium M5461976
EExia COUPLING G1
Order numbers :
AISI316L M546194
Hastelloy -C M547886
Titanium M547885
HYGIENIC COUPLING G1
Order numbers :
AISI316L M548101
Hastelloy -C M548102
Titanium M548103
STANDARD COUPLING G1 WITH CLEANING
Order numbers :
AISI316L M1050020
Hastelloy -C M10500203
THREADED STEEL PIPE FITTING, G1
(FOR COUPLING G1/G1A) Order number M105 0220
COUPLING G1/ G1A
Order numbers :
AISI316L M1050002
Hastelloy -C M10500023
COUPLING G1 / M44x1.25 (PMC)
Order numbers :
AISI316L M1050004
Hastelloy -C M10500043
COUPLING G1 / PMC 1.5"
Order numbers :
AISI316L M1050010
Hastelloy -C M10500103
COUPLINGS SMS-STANDARD:
COUPLING G1 / SMS 38
Order number M105 0265
COUPLING G1 / SMS 51 Order number M105 0267
HG
pressure transmitter belongs to the series H transmitters which will have both
analog and smart properties. HG is used for 0-40 mbar...0-150 bar ranges. The transmitter
communicates in a 2-wire system. In pressure measuring applications HG-transmitters are
used for measuring the pressure of clean, sedimenting, crystallizing and sticking
materials. The transmitter's sensor is piezoresistive. The rangeability on Smart option is
15:1. The transmitter communicates digitally using the HART® protocol.
HT pressure transmitter belongs
to the series H transmitters which will have both analog and smart properties. HT is used
for 0-1.45 bar...0-1000 bar ranges. The transmitter communicates in a 2-wire system. In
pressure measuring applications HT-transmitters are used for measuring the pressure of
clean gases, steam and non-crystallizing liquids. The transmitter's sensor is
piezoresistive. The rangeability on Smart option is 15:1. The transmitter communicates
digitally using the HART® protocol.
HL pressure transmitter belongs
to the H transmitter family. The series H transmitters have both analog and smart
properties. HL is used for 0-40 mbar...0-150 bar ranges. The transmitter communicates in a
2-wire system. In pressure measuring applications HL-transmitters are used for measuring
the pressure of clean, sedimenting, crystallizing and sticking materials. The
transmitter's sensor is piezoresistive. The rangeability on Smart option is 15:1. The
transmitter communicates digitally using the HART® protocol.
HDL
differential pressure transmitter belongs to the H transmitter family. The series
H transmitters have both analog and smart properties. HDL is used for 10 mbar...22 bar
ranges. The transmitter communicates in a 2-wire system. In pressure measuring
applications HDL transmitters are used for liquid level, pipeline pressure and density
measurements. HDL transmitter is equipped with an SOS (Silicon On Sapphire) sensing
element. The rangeability on Smart option is 15:1. The transmitter communicates digitally
using the HART® protocol.
HV pressure transmitter belongs to the H transmitter family. The
series H transmitters have both analog and smart properties. HV is used for 0-40
mbar...0-2 bar ranges. The transmitter communicates in a 2-wire system.
HV pressure transmitter is suitable for liquid level measurements in ground and rock
tanks, and in open channels and ships' tanks. HV pressure transmitter can be used in
corrosive conditions and to measure contaminating liquids. Possible foam on the surface of
the measured liquid does not disturb the measurement. HV does not require compressed air
supply.
The transmitter's sensor is piezoresistive. The rangeability on Smart option is 15:1.
The transmitter communicates digitally using the HART® protocol.
Differential Pressure & Flow Measurement
HD
pressure transmitter belongs to H-transmitter family. The series H transmitters
have both analog and smart properties. HD is used for 0-1 mbar...0-150 bar ranges. The
transmitter communicates in a 2-wire system. In pressure measuring applications
HD-transmitters are used for measuring differential pressure and vacuum pressure. HD
transmitter is equipped with an SOS (Silicon On Sapphire) sensing element. The
rangeability on Smart option is 15:1. The transmitter communicates digitally using the
HART® protocol.