The +GF+ SIGNET 9010 Flow
Controller is engineered for liquid flow measurement and control in process pipes. The
modular design offers the advantage of expanding a system by plugging a relay card into
the main unit, or up to two analog output cards. All functions are accessed and controlled
from the front panel which is ideal for mounting into instrumentation panels.
Features
DC and/or AC powered
Pump pulsing capability
Programmable security access
Modular input/output options
Menu driven operation
8-digit totalizer
Applications
Proportional addition mixing/dosing
Flow rate alarm
Pump sequencing
Effluent totalization
Compatibility
All +GF+ SIGNET flow sensors
Technical Data
Operating
Range:
Frequency:
1 to 10 kHz
K-Factor range: 0.0001 to 19999
Power Requirements:
17 to 30 VDC @ 0.5A
max. and/or 90 to 132 VAC or 180 to 264 VAC, 50-60 Hz
4 to 20 mA, iso or
non-iso, internally pwrd. (2 of 3 card slots avail.)
Loop impedance: 425 ohm max.
Accuracy: +/-0.5% of full scale
Update Rate: 2.5 sec.
Voltage Output:
0 to 5 or 0 to 10
VDC, isolated or non-isolated
Min. load resistance: 1 k ohm
Output isolation: 500 VDC to earth ground (iso version only)
Alarm Contacts:
Two SPDT relays: 5A
@ 30 VDC or 250 VAC max. (1 of 3 card slots available)
Hi/Lo/Pulse programmable with adj. hysteresis or pulse programmable
Operating Cond.:
Operating
temperature: 32 to 130 degrees F
Relative humidity: 0 to 95%, non-condensing
Accuracy:
0.05% of reading
Materials:
Enclosure: ABS
Plastic, NEMA 4X/IP65
Panel and case gasket: Neoprene
Ordering Information
Part
No.
Description
3-9010.111
Flow Controller, 90
to 132 VAC, frequency input card
3.9010.121
Flow Controller, 180 to 264 VAC,
frequency input card
3-9010.110
Flow Controller, 90 to 132 VAC,
no input card
3-9010.120
Flow Controller, 180 to 264 VAC,
no input card
Accessories
3-9010.400-1
Frequency Input
Card, non-isolated
3-9010.400-3
0 or 4 to 20 mA
Input Card, isolated
3-9010.400-4
0 to 5 or 10 VDC
Input Card, isolated
3-9000.450-1
0/4 to 20 mA non-iso
output card
3-9000.450-2
0 to 5 VDC non-iso output card
3-9000.450-3
0 to 10 VDC non-iso output card
3-9000.460-1
0/4 to 20 mA iso output card
3-9000.460-2
0 to 5 VDC iso output card
3-9000.460-3
0 to 10 VDC iso output card
3-9000.440-1
2 relay card
3-5000.395
Splashproof Back Cover Kit
3-5000.598
Mounting Bracket
3-5000.399
Retrofit Adapter Kit
3-9000.392
Liquid Tight Connector Kit
+GF+ SIGNET 9030 pH
Controller
Description
Using the plug-in cards, the +GF+
SIGNET 9030 pH Controller can expand from on-off to proportional control, plus a variety
of outputs for recording or data logging. Combine the 9030 with +GF+ SIGNET electrodes and
pre-amplifier for a simple solution for any pH application.
Features
On-off or dual proportional control
Up to four relays
Up to two analog outputs
Applications
Plating baths
Fume scrubbers
Effluent pretreatment
Water and waste treatment systems
Groundwater remediation
Acid/base neutralization
Resource reclamation
Compatibility
2720 pH/ORP Pre-amp/Sensor System
Technical Data
Operating
Range:
pH: 0
to 14, input isolated
Temperature: 4 to 230 degrees F (Auto temp. comp. from 32 to 21 degrees F)
Power Requirements:
17 to 30 VDC @ 0.5A
max. and/or 90 to 132 VAC or 180 to 264 VAC, 50-60 Hz
4 to 20 mA, iso or
non-iso, internally pwrd. (2 of 3 card slots avail.)
Loop impedance: 425 ohm max.
Accuracy: +/-0.5% of full scale
Voltage Output:
0 to 5 or 0 to 10
VDC, isolated or non-isolated
Min. load resistance: 1 k ohm
Output isolation: 500 VDC to earth ground (iso version only)
Alarm Contacts:
Two SPDT relays: 5A
@ 30 VDC or 250 VAC max. (2 of 3 card slots available)
Hi/Lo programmable with adjustable hysteresis
Two SPST relays: 5A @ 30 VDC or 250 VAC max.
Hi/Lo/Pulse programmable with adj. hysteresis or pulse rate
Operating Cond.:
Operating
temperature: 32 to 130°F
Relative humidity: 0 to 95%, non-condensing
Accuracy:
+/-0.02 pH
Materials:
Enclosure: ABS
Plastic, NEMA 4X/IP65
Panel and case gasket: Neoprene
Ordering Information
Part
No.
Description
3-9030.111
pH Controller, 90 to
132 VAC
3.9030.121
pH Controller, 180 to 264 VAC
Accessories
3-9000.450-1
0/4 to 20 mA non-iso
output card
3-9000.450-2
0 to 5 VDC non-iso output card
3-9000.450-3
0 to 10 VDC non-iso output card
3-9000.460-1
0/4 to 20 mA iso output card
3-9000.460-2
0 to 5 VDC iso output card
3-9000.460-3
0 to 10 VDC iso output card
3-9000.440-1
2 relay card
3-9000.400-1
Dual Proportional relay card
3-5000.395
Splashproof Back Cover Kit
3-5000.598
Mounting Bracket
3-5000.399
Retrofit Adapter Kit
3-9000.392
Liquid Tight Connector Kit
+GF+ SIGNET 9040 ORP
Controller
Description
The +GF+ SIGNET 9040 ORP
Controller provides reliable control of oxidizing and reducing reactions. Multiple output
options allow for alarming, data logging, or simple process recording. Security features
prevent unwanted tampering..
Features
On-off or dual proportional control
Up to four relays
Up to two analog outputs
Applications
Effluent pretreatment
Water and waste treatment systems
Groundwater remediation
Resource reclamation
Cyanide destruction
Metals recovery and removal
Water sanitation systems
Disinfection
Compatibility
2720 pH/ORP Pre-amp/Sensor System
Technical Data
Operating
Range:
ORP:
+/-1000 mV's
Power Requirements:
17 to 30 VDC @ 0.5A
max. and/or 90 to 132 VAC or 180 to 264 VAC, 50-60 Hz
The +GF+ SIGNET 9050CR
Conductivity Controller offers modularity easily adaptable to any conductivity or
resistivity application. Easy single-point "wet-cal" allows for instant accurate
calibration. Programming options include display units and temperature compensation.
Outputs can be assigned to any channel or display parameters.
Features
Two-channel capability
µS, mS, K, M, ppm, and percent
rejection
Up to four relays can be installed
DC and/or AC powered
Applications
Reverse osmosis
Demineralization
Boiler protection
Water and waste treatment systems
Groundwater remediation
Cooling tower blowdown
Resource reclamation
Compatibility
2800 Series Conductivity Sensors
Technical Data
Operating
Range:
Conductance:
0.055 to 400,000 µS
Resistance: 10 k to 18.3 M (0.055 to 100 µS) must be performed in solution temperatures
from 20 to 100 degrees C
Temperature: PT-1000, 32 to 212 degrees F
(Temperature display and alarming from: 14 to 302°F)
Power Requirements:
17 to 30 VDC @ 0.5A
max. and/or 90 to 132 VAC or 180 to 264 VAC, 50-60 Hz
4 to 20 mA, isolated
or non-isolated, internally powered (2 of 3 card slots available)
Loop impedance: 425 ohm max.
Accuracy: +/-0.5% of full scale
Voltage Output:
0 to 5 or 0 to 10
VDC, isolated or non-isolated
Min. load resistance: 1 k ohm
Output isolation: 500 VDC to earth ground (isolated only)
Alarm Contacts:
Two SPDT relays: 5A
@ 30 VDC or 250 VAC max. (2 of 3 card slots available)
Hi/Lo/Pulse programmable with adj. hysteresis or pulse rate
Two SPST relays: 5A @ 30 VDC or 250 VAC max.
Hi/Lo/Pulse programmable with adj. hysteresis or pulse rate
Temperature compensation: Programmable 0 to 10% per degree C
TDS Conversion Factor: Prog. 0.00 to 3.00µS/ppm (default 2.00)
Operating Cond.:
Operating
temperature: 32 to 130 degrees F
Relative humidity: 0 to 95%, non-condensing
Accuracy:
+/-2% of reading
Materials:
Enclosure: ABS
Plastic, NEMA 4X/IP65
Panel and case gasket: Neoprene
Immunity:
IEC 801-2 level 4, IEC 801-3
level 1
Ordering Information
Part
No.
Description
3-9050CR.1
Cond./Resistivity
Controller 110VAC
3.9040.121
Cond./Resistivity Controller 220
VAC
Accessories
3-9000.450-1
0/4 to 20 mA non-iso
output card
3-9000.450-2
0 to 5 VDC non-iso output card
3-9000.450-3
0 to 10 VDC non-iso output card
3-9000.460-1
0/4 to 20 mA iso output card
3-9000.460-2
0 to 5 VDC iso output card
3-9000.460-3
0 to 10 VDC iso output card
3-9000.440-1
2 relay card
3-9000.400-1
Dual Proportional relay card
3-5000.395
Splashproof Back Cover Kit
3-5000.598
Mounting Bracket
3-5000.399
Retrofit Adapter Kit
3-9000.392
Liquid Tight Connector Kit
Phone:
813-971-5001
Fax : 813-971-5117
Omni
Controls Inc.
5309 Technology Dr.
Tampa, FL 33647
Toll
Free
1-800-783-6664
Sales@Omnicontrols.com
We
guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers