Signet Magmeter
Description
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Output Signal: | 4 to 20 mA non-isolated, internally powered |
| Operating Range: | 0.1 to 7 m/s, 0.3 to 20 ft/s |
| Full Scale Range: | 1 to 5 m/s, 3 to 15 ft/s recommended (minimum liquid conductivity = 20µS/cm) |
| Pressure/Temperature: | 180 psi @ 68 degres F, 25 psi @ 185 degrees F |
| Power Requirements: | 20 to 30 VDC |
| Alarm Contacts: | One SPDT relay: 0.5A @ 75VDC or 0.4A @ 60 VAC max. |
| Pipe Size Range: | 0.5 to 4 in. |
| Repeatability: | +/-2% of reading at measuring electrode with local calibration at flow velocities >1m/s |
| Materials: | Sensor tip: PVDF Sensor electrodes: 316L SS Sensor body: 316L SS Fitting adapter: 316L SS Adapter seal: NBR Sensor cap: glass-filled polypropylene O-rings: Viton® Housing: Aluminium, epoxy powder coated IP66/NEMA 4X Weight: 3.5 lbs. |
| Quality Standards: | CE |

Additional support may be required for small pipe diameters. Observe pressure/temperature specifications of all system components.
Dimensions
![]()

Part No. |
Description |
| 3-2560-1 | Flowmag with 0.5 in. NPT Cable Gland Ports |
| 3-2560-2 | Flowmag with PG16 Cable Gland Ports |
DescriptionThe +GF+ SIGNET 2550 Insertion Magmeter combines the installation and maintenance ease of insertion sensors with the features of a full-line magmeter to provide a low-cost alternative for the most demanding flow applications. The 2550 is easy to handle, and simple to remove from line for quick maintenance without major operational shutdowns.
| Output Signal: | Isolated current
output: 0/4 - 20 mA into 600 Ohm maximum load internally powered Isolated frequency output: 500 Hz = 20 ft/s, 50% duty cycle, open collector |
| Operating Range: | 0.3 to 20 ft/s (minimum liquid conductivity = 5 µS) |
| Pressure/Temperature: | 250 psi max. Ambient temperature: -4 to 176 degrees F Liquid temperature: 32 to 212 degrees F |
| Power Requirements: | 24 VDC +/-10%, 600 mA max. |
| Pipe Size Range: | 2 to 12 in. |
| Repeatability: | +/-2% of reading or +/-0.05 ft/s, whichever is greater |
| Materials: | Sensor body, retaining ring,
threaded nut: 316 SS Sensor tip: PFA Teflon® Electrodes: 316 SS O-rings: Viton® Housing: Die cast aluminum |
| The 2550 installs into
standard fittings with 2 in. NPT or ISO 7/1-R2 threads. Select a location where the flow
profile is fully developed and not affected by any disturbances. Mount the 2550 at any convenient angle. Full pipes are required. |
![]() |

Dimensions
![]()

Part No. |
Description |
| 3-2550.100-110 | Insertion Magmeter with 2 in. NPT Fitting |
| 3-2550.100-110T | Insertion Magmeter with 2 in. NPT Fitting and Installation Tool |
| 3-2550.100-111 | Insertion Magmeter with 2 in. ISO Fitting |
| 3-2550.100-111T | Insertion Magmeter with 2 in. ISO Fitting and Installation Tool |
Accessories |
|
| 3-2550.355 | Magmeter Installation Tool |
Complete Your Flow System
![]()
The 2550 is ready to provide data requirements for most flow control applications, from simple recording to total PLC system input. The frequency output signal also allows expansion of the flow control capability by connecting to a wide selection of flow instruments available from +GF+ SIGNET.

| LF430 Series TOSHIBA Magnetic Flowmeters (Magmeters) | More_Info |
| These
cost-effective flowmeters combine superior noise immunity with high
purity ceramic detection unit liners, allowing precise measurement in a
wide range of applications. |
|