SPECIFICATIONS
Display
2 lines, 6 characters each
Top line 0.6″ (15mm) characters
Bottom line 0.46″ (12mm) characters
Display Update Speed
200 ms (5 updates per second)
Accuracy
± 0.03% of calibrated span
Front panel rating
NEMA 4X, IP65
Storage Temp
-40° to 185° F (-40° to 85° C)
Operating Temp
-40° to 149° F (-40° to 65° C)
Programmable Features
Min/Max, Tare, Hold
Multiscale Input Display (e.g. Level & Volume
Noise Filter
High/Low Alarms
Alternating Pump Control
Time Delay for Output Relays
Methods
4 Front-panel Push Buttons
MeterView Pro Software (with PC)
Size>
6.42″ x 9.97″ x 8.47″ (163 mm x 202 x 215 mm)
Weight
16.0 oz (7.26 kg)
Input Options
0-20 mA, 4-20 mA
0-5 VDC, 1-5 VDC, 0-10 VDC, ±10 VDC
Output Options
2 or 4 SPDT Relays
Isolated 4-20 mA
FM Certificate
Enclosure Type 4X; IP66
ClassI, Div. 1, Groups B, C, D
Class II, Div. 1, Groups E, F, G
Class III, Div. 1 T5/T6
Class I, Zone 1, AEx D, IIC Gb T5/T6
Zone 21, Aex tb IIC T90°C; Ta -40°C to +6-°C
T6 Ta = -40°C to +60° C; T5 Ta = -40° C to +65° C
CSA Explosion Proof
Class I, Div. 1, Groups B, C, D
Class II, Div. 1, Groups E, F, G
Class III, Div. 1
Class I Zone 1 Ex d IIC
Zone 21 Ex tb IIC T90° C
-40°C > Tamb. > +65°C; Temperature Code T6
-40° C > Tamb. >: +65° C; Temperature Code T5
Enclosure Type 4X & IP66
ATEX
Ex II 2 G D
Ex d IIC T* Gb
Ex tb IIIC T90° C Db IP68
Ta + -40deg; C to + *° C
*T6 = -40° C to +60° C
*T5 = -40° C to +65° C
IECEx
Ex D IIC T* Gb
Ex tb IIIC T90° C Db IP68
Ta = -40° C to + *° C
*T6 = -40°C to +60°C
*T5 = -40° C to +65° C
Supply Voltage
VAC: 85-265
VDC: 12-24
Input Impedence
Voltage Inputs > 500 kΩ
Current Inputs: 50-100 Ω
SPDT Relays
3 A @ 30 VDC / 125/ 250 VAC resistive loads
1/14 HP (≈ 50 W) @ 125/250 VAC inductive loads
Input Contact/Digital Input
Contact Voltage: 3.3 VDC
Digital Input Logic High: 3-5 VDC
Digital Input Logic Low: 0-1.25 VDC
Default Logic: Normally Open/Low