Universal clamp-meter / multimeter.
The CMP-2000 is ruggedly constructed, and egonomically designed for technicians and engineers to use comfortably for long periods.
A variety of functions are all at your fingertips in a hand-held device.
Measures current up to 2,000 A; the large jaw is 2.4 ins diameter, and it can clamp around bus bars 2.75 x 0.7 ins.
Safety First!
CAT IV 600 V measurement category.
The instrument has an electronic overload protection of all functions and ranges.
Features:
- AC current measurement (TRUE RMS) up to 1,500 Amps and DC up to 2,000 Amps.
- Measurement of INRUSH current for start-up of electrical motors or equipment.
- AC voltage measurement (TRUE RMS) up to 750 VAC and DC up to 1,000 VDC.
- Resistance measurement for resistances below 30 Ω
- Continuity test with audio.
- Capacitance measurement.
- Temperature measurement (Fahrenheit or Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
AC current measurement (TRUE RMS) up to 1,500 A and DC up to 2,000 A.
Measurement of INRUSH current in start-up phase of electrical device.
AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1,000 V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
Capacitance measurement
Temperature measurement (Fahrenheit or Celsius).
Frequency measurement.
Duty cycle measurement.
Diode test.
Additionally:
- safe, insulated measuring clamp,
- autoranging,
- „DATA HOLD” function, for holding measured values,
- backlit LCD,
- „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
- „MAX/MIN” function,
- over range indication,
- „AUTO-OFF” function after 30 min.
Electric security:
- measurement category: CAT IV 600 V acc. to EN 61010 – 1,
- protection class acc. to EN 60529: IP20,
Other technical data:
- power supply, 9 V battery type 6LR61,
- display: 6,600 counts, backlit LCD,
- continuity test: threshold 30 Ω,
- diode test: test current of 0.8 mA , typical open circuit voltage 3.2 V DC, typical,
- low battery indication: BAT displayed,
- over range indication: ‘OL’ displayed,
- temperature sensor: type K thermocouple,
- input impedance: ca.10 MΩ (V DC and V AC),
- AC bandwidth: 50 to 500 Hz,
- auto power OFF: 30 minutes,
- dimensions: 11″ x 4.25″ x 2.09″ / 281 x 108 x 53 mm,
- weight: 1.26 lbs / 570 g (with battery),
- accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.
Rated operational conditions:
- able to open the clamp: Ø 2.25″ / 57 mm wire; 2.75″ x 0.7″ / 70 x 18 mm bus bar,
- operating temperature: 32F to 122F / 0 to +50 °C,
- storage temperature: -4F to 140F / -20 to +60 °C,
- operating altitude: max 6,562 ft / 2,000 m.
DC current measurement
Range | Resolution | Accuracy |
0.0 to 659.9 A | 0.1 A | ±(2.0% m.v. + 5 digits) |
660 to 2000 A | 1 A | ±(3.0% m.v. + 5 digits) for 660 to 1000 A |
±(5.0% m.v. + 5 digits) for 1000 to 2000 A |
AC current measurement (TRUE RMS)
Range | Resolution | Accuracy |
0.0 to 659.9 A | 0.1 A | ±(2.0% m.v. + 10 digits) for 50 to 60 Hz |
±(3.0% m.v. + 10 digits) for 61 to 400 Hz | ||
660 to 1,500 A | 1 A | ±(2.5% m.v. + 10 digits) for 50 to 60 Hz and 660 to 1000 A |
±(3.5% m.v. + 10 digits) for 61 to 400 Hz and 660 to 1000 A | ||
±(5.0% m.v. + 10 digits) for 50 to 400 Hz and 1000 to 1500 |
DC voltage measurement
Range | Resolution | Accuracy |
0.000 to 6.599 V | 0.001 V | ±(0.5% m.v. + 2 digits) |
6.60 to 65.99 V | 0.01 V | |
66.0 to 659.9 V | 0.1 V | |
660 to 1,000 V | 1 V |
AC voltage measurement (true RMS)
Range | Resolution | Accuracy |
0.000 to 6.599 V | 0.001 V | ±(1.5% m.v. + 8 digits) for 50 to 500 Hz |
6.60 to 65.99 V | 0.01 V | |
66.0 to 659.9 V | 0.1 V | |
660 to 750 V | 1 |
Resistance measurement
Range | Resolution | Accuracy |
0.0 to 659.9 Ω | 0.1 Ω | ±(1.0% m.v. + 5 digits) |
0.660 to 6.599 kΩ | 0.001 kΩ | |
6.60 to 65.99 kΩ | 0.01 kΩ | |
66.0 to 659.9 kΩ | 0.1 kΩ | |
0.660 to 6.599 MΩ | 0.001 MΩ | ±(2.0% m.v. + 5 digits) |
6.60 to 66.00 MΩ | 0.01 MΩ | ±(3.5% m.v. + 5 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
0.0 to 6.599 nF | 0.001 nF | ±(3.0% m.v. + 30 digits) |
6.60 to 65.99 nF | 0.01 nF | ±(3.0% m.v. + 10 digits) |
66.0 to 559.9 nF | 0.1 nF | ±(3.0% m.v. + 30 digits) |
6.600 to 59.999 µF | 0.001 µF | ±(3.0% m.v. + 10 digits) |
66.00 to 659.99 µF | 0.01 µF | |
660 to 659.999 µF | 0.100 µF | |
0.660 to 6.600 mF | 0.001 mF |
Frequency measurement
Range | Resolution | Accuracy |
10 to 65.99 Hz | 0.01 Hz | ±(0.1% m.v. + 5 digits) |
66.0 to 659.9 Hz | 0.1 Hz | |
0.660 to 6.599 kHz | 0.001 kHz | |
6.60 to 65.99 kHz | 0.01 kHz | |
66.0 to 659.9 kHz | 0.1 kHz | |
0.660 to 1.000 MHz | 0.001 MHz |
Temperature measurement
Range | Resolution | Accuracy |
-20 to 0°C | 1°C | ±(2.0% m.v. + 3°C) |
0 to 399°C | ±(1.0% m.v. + 2°C) | |
400 to 1,000°C | ±(2.0% m.v. + 3°C) | |
-4 to 31°F | 1°F | ±(2.0% m.v. + 6°F) |
32 to 749°F | ±(1.0% m.v. + 4°F) | |
750 to 1832°F | ±(2.0% m.v. + 6°F) |
Duty cycle measurement
ange | Resolution | Accuracy |
5 to 95% | 0.1% | ±(2.0% m.v. + 10 digits) |
„m.v.”- measured value
Be the first to review “Clamp multimeter CMP-2000”