The FLIR CM46 clamp meter is designed for commercial and residential electricians. Featuring both AC/DC measurement, the meter is equipped with a bright backlit display for use inside electrical panels. Accu-Tip™ technology delivers amperage measurements on smaller-gauged wires more accurately — to a tenth of a digit. The meter also offers MAX/MIN/AVG recording; measures DCµA, temperature, capacitance, and frequency; and has electrical field detection to help you determine voltage presence and relative strength of the field.
OVERVIEW
- Backlight LCD: Yes
- Jaw Opening: 30 mm Max
- Warranty: Limited Lifetime
COMPLIANCE & CERTIFICATIONS
- Certifications: UL , CE
ENVIRONMENTAL
- Drop test: 2m
- Operating Temperature: -10°C to 50°C (14 to 122°F)
- Temperature: -40°C to 400°C (-40°F to 752°F) (Basic Accuracy ±1.0%)
MEASUREMENT & ANALYSIS
- AC Voltage (Digital Low Pass Filter-VFD): 600 V (Basic Accuracy ±1.0%)
- AC/DC Voltage (Digital Low Pass Filter – VFD): 600 V (Basic Accuracy ±1.2%)
- Accu-Tip Clamp-On AC Current: 60 A (Basic Accuracy ±1.5%)
- Accu-Tip Clamp-On DC Current: 60 A (Basic Accuracy ±2.0%)
- Capacitance: 2500 µF (Basic Accuracy ±2.0%)
- Clamp-On DC Current: 400 A (Basic Accuracy ±2.0%)
- Continuity:10Ω< & < 250Ω
- DC microA: 2000 µA (Basic Accuracy ±1.0%)
- DC Voltage: 600 V (Basic Accuracy ±1.0%)
- Diode: 2.0 V (Basic Accuracy ±1.5%)
- Frequency: 50-400 Hz (Basic Accuracy ±1.0%)
- Resistance: 60 kΩ (Basic Accuracy ±1.0%)
- Clamp-On AC Current (50-100 Hz): 400 A (Basic Accuracy ±1.8%)
- Clamp-On AC Current (100-400 Hz): 400 A (Basic Accuracy ±2.0%)
METER DATA
- Category: CAT IV 300V / CAT III 600V
- Display: 3-5/6 digits 6000 counts
- NCV: Yes
- Recording: Min / Max / Avg
POWER
- Battery type: 2x AAA