Specifications PDF Fluke Norma 4000 Idealfor field testing the Fluke Norma 4000 Three Phase Power Analyzer offers easyand straight forward operation with unmatched price performance Featuresinclude 1 to 3 power phases 5 7 144 mm color display harmonic analysis scope mode vector diagram display recorder function Fluke NormaView PCsoftware and expandable 4 MB RAM data memory Fluke Norma 5000 Providingthe highest bandwidth on the market the Fluke Norma 5000 Six Phase PowerAnalyzer is the ideal test and analysis tool for the development of frequencyconverters and lighting equipment Features include 3 to 6 power phases optional internal printer and all of the Fluke Norma 4000 features andfunctionality described above Compact design makes it easy to carry and saves working space Simple user interface ensures easy intuitive operation A variety of standard configurations allows users to choose the exact functionality required for their unique application Simultaneous parallel acquisition of all phases allows accurate viewing of dynamic events on all phases at exactly the same point in time All inputs are galvanically isolated to avoid short circuits in all applications Voltage current and power harmonics measured up to the 40th harmonic for complete analysis FFT analysis vector diagram and Digital Oscilloscope DSO mode included in the base unit for complete analysis capability User selectable average time from 15ms up to 3600s for dynamic measurements 4 MB on board memory expandable to 128 MB for storage of measured values Fast and easy connection to a PC RS232 and USB included as standard optional IEEE488 Ethernet or USB2 0 PI1 process interface to measure torque and speed with external sensors plus four analog outputs for easy use on motor and drive applications 341kHz or 1 MHz sample rates for detailed signal analysis Bandwidth from dc to 3 MHz 10 MHz for reliable measurement precision Fluke NormaView PC software for data download analysis report writing General Specifications Number of Phases Fluke Norma 4000 1 to 3 Fluke Norma 5000 3 4 or 6 Weight Fluke Norma 4000 Approx 5 kg 11 lb Fluke Norma 5000 Approx 7 kg 15 lb Size Fluke Norma 4000 150 mm x 237 mm x 315 mm 5 9 in x 9 3 in x 12 4 in Fluke Norma 5000 150 mm x 447 mm x 315 mm 5 9 in x 17 6 in x 12 4 in On board Printer Fluke Norma 4000 No Fluke Norma 5000 Yes optional Display Color 5 7 144 mm 320 x 240 pixel User selectable background lighting and contrast Bandwidth dc to 3MHz or dc to 10MHz depending on input module Basic Accuracy 0 2 0 1 or 0 03 depending on input modules Sampling Rate 0 33 MHz or 1 MHz depending on input modules Voltage Input Range 0 3 V to 1000 V Current Input Range direct not via shunt 0 03 mA to 20 A depending on input module Memory for Configurations 4 MB Memory for Settings 0 5 MB Fast Fourier Transformation FFT To the 40th harmonic RS232 USB Interface Standard PI1 Process interface 8 analog impulse inputs and 4 analog outputs Optional IEEE 488 2 GPIB interface 1 MBit s Ethernet 10 MBit s or 100 MBit s Optional Fluke NormaView PC software for data download analysis report writing Standard Basic Functions Fast Fourier Transformation FFT Calculation of harmonics with graphical representation Up to 3 bar graphs are displayed at the same time Measured values U I P per phase Order 1st to 40th harmonics maximum half sample frequency Digital Oscilloscope DSO Simultaneous display of up to 3 measured values on sample level Quick view of curve form and distortion Integration function energy Simultaneous display of up to 6 configurable numeric values Start Stop conditions and positive negative direction available Vector Display Vector display of HO1 up to 6 signals For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal Recorder Display of average values over time for trend determination RAM data memory Storing of sample and average values setting of start and stop conditions From the RAM approximately 4 MB are available for the storage of measured values Configuration Set up the analyzer to measure and display data in the format required Ambient Conditions Working Temperature Range 5 C to 35 C 41 F to 95 F Storage Temperature Range 20 C to 50 C 4 F to 122 F Housing Material Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements Climatic Class KYG DIN 40040 max 85 relative humidity non condensing Power supply 85 V ac to 264 V ac 50 Hz to 60 Hz dc 100 to 260 V ca 40 VA European plug with switch Binding post for current available on some models Measuring Inputs Safety sockets 4 mm 2 for each input External shunt connection over BNC socket Operation Membrane keyboard with cursor function keys and direct functions Connections Rear panel of the 3 phase Analyzer Measured Values Non gapping calculation of averaged values for each phase In three phase system additionally calculation of total power and averaging of V and I of the three phases The fundamental H01 will be calculated in synchronous mode also for these values Urms effective value Urm rectified mean Um mean value Up Up Upp peak values Ucf crest factor Ucf Uff form factor Ufc fundamental content Uthd distortion factor DIN IEC Irms effective value Irm rectified mean Im mean value Ip Ip Ipp peak values Icf crest factor Icf Iff form factor Ifc fundamental content Ithd distortion factor DIN IEC P active power W Q reactive power Var S apparent power VA cos phase angular Integral function for active power P reactive power Q apparent power S voltage Um and current Im Number of digits 4 or 5 dependent on measured value Frequency and Synchronization Range DC and 0 2 Hz to sample rate Accuracy 0 01 of measured value reading Channels which can be selected all U I or external input One of three low pass filter with different frequencies can be switched into the signal The frequency is always visible on the top of the screen The BNC synchronization socket on backside of the instrument can be used either as input or output The input signals can be measured up to the sample rate of the power phase The maximum level must not be higher then 50V The output signal is a pulsed 5Volts TTL signal frequency depends on the measured synch frequency Configuration Memory Up to 15 user configurations can be saved into a permanent memory and reloaded later on Changes that were not saved are lost after switching off the instrument Interface RS232 interface for upload of firmware and data exchange with the PC A printer can be connected over an external converter Options IEEE 488 2 1 MBit s Ethernet 10 MBit s or 100 Mbit s Standards and Safety Electrical Safety EN 61010 1 2nd Edition 1000 V CAT II 600V CAT III Degree of pollution 2 safety Class I EN 61558 for transformer EN 61010 2 031 032 for accessories Maximum inputs For voltage inputs Measurement range 1000 Veff 2 kVpeak For current inputs Measurement range 10 Aeff 20 Apeak Test voltage
Fluke Norma 5000 High Precision Power Analyzer
$64177.99
Fluke Norma 5000 High Precision Power Analyzer
NORMAL DELIVERY 1-2 weekCall us to get the exact delivery date.
International Credit cards are not accepted on online orders.
Brand:Fluke
Warranty: As per Manufacturer policy
100% Genuine Product
Brand Warranty
Easy and Secure Payment
Timely delivery with complete tracking
Be the first to review “Fluke Norma 5000 High Precision Power Analyzer”