PIE Model 541 – Frequency Read & SourceCalibrator with Totalizer. Includes wire kit,
carrying case and FREE NIST Traceable Certificate of Calibration
Frequency Read & SourceFunctions
-
Accuracy ± 0.005% of range
-
Source and Read
-
Six Ranges 1 count per hour to 20.000Khz
-
Calibrate Totalizer input and outputs from 1 to 99999
-
Count Pulses 1 to 99999
-
LED indicator for gate time
Read Function
-
Read a wide range of Frequencies and Waveforms
-
Read 50mV to 120V peak
-
Read signals from Flowmeter pickups, Velocity and
-
Motion Detectors
-
Totalizers
Source Function
Sine and Square waves, Zero Basedand Zero Crossing
-
Frequency from 1CPH to 20 KHz
-
Adjustable amplitude from 100mV to 12Volts peak-to-peak
-
Simulates Vibration Pickups, Variable Speed Drives and more
Calibrate Totalizers
Output a number of pulses from 1to 100 minutes
Gate Trigger Indicator
The LED flashes in synch with theoutput frequency. This allows easy adjustment of the
attenuation for proper gate triggering.
Full 5 Digit Display
-
True ±0.005% of range accuracy
-
Bar graph for quick reference of trigger level and output levels, 5% of frequency range
High contrast graphic display viewable in all lighting conditions and angles
EZ-Dial™Knob
Change the speed of dialing yourtest point by just pushing down on the knob
EZ-Check™Switch
Stop watch style push button foraccurate totalizer measurements and for high and low readings
Â
Uses a standard 9V AlkalineBattery
Superior battery life of 24 hoursunder typical continuous usage
Easy access to battery compartment
240 VAC Tolerant
Fuse-less protection fromaccidental misuse
Lightweight and rugged with asolid feel
Convenient Velcro® hand strapallows for a firm confident grip or attachment to pipes and ladders.
Description
The Practical InstrumentElectronicsÂ’ Model 541 is the best tool for calibration, test, and diagnosing
turbine meters, frequency counters, vibration systems, tachometers, vortexshedders, integrators,
and any other Frequency devices in the shop, plant and/or field. The Model 541brings all the features
you would expect from a frequency calibrator and timesaving new ones. The model541 comes with an
LED indicator showing gate time for easy trigger level adjustment. Makeadjustments with the EZ-Dial™
Knob or test limits with the dual action EZ-Check™Switch. Save hours of troubleshooting
time on problems when compared to other calibration methods. When calibrating atotalizer,
the model 541 eliminates the need of a stop watch. This calibrator willautomatically
stop when the selected
number of pulses has been sent to the totalizer.
General Specifications:
(Unless otherwise indicatedall specifications are rated from a nominal 23 °C, 70 % RH
for 1 year from calibration)
Operating Temperature Range -20 to 60 °C (-5 to 140 °F) Storage Temperature
Range -30 to 60 °C (-22 to 140 °F)
Relative Humidity Range 10 %≤RH ≤90 % (0 to 35 °C), Non-condensing
10 % ≤RH≤ 70 % (35 to60 °C), Non-condensing
Size 7.00 X 3.30 X 2.21 inches (177.8 x 83.8 x 56.1mm)
Weight 12.0 oz (340 grams)
Battery 9V Alkaline
Miscellaneous Low batteryindication with nominal 1 hour of operation left
Over-voltage protection to 120Vrms (rated for 30 seconds) or 240 Vrms
(rated for 15 seconds)
High contrast graphic liquidcrystal display with 0.45″ (11.4 mm) highdigits
Â
Common Specifications for allFrequency Modes:
Frequency Ranges 1CPH to 20.000KhzAccuracy ± 0.005% of range
Temperature Effect ≤ 10ppm/°C of range
Â
Frequency Ranges Specifications:
-
1 CPH< CPH Range < 20000 CPH
-
0.1 CPM (0.0167Hz)< CPM Range < 2000.0 CPM (33.33Hz)
-
0.01Hz < Hz < 200.00Hz
-
0.1Hz < Hz Range < 2000.0Hz
-
0.001KHz < KHz Range < 20.000KHz
-
Totalize inputs/outputs from 1 to 99999 counts in 0.1 minutes to 100.0 minutes
Calibration Certificate
-
NIST Traceable Certificate provided
-
Option: Test data available upon request at additional charge.
Be the first to review “Frequency Read & Source Calibrator”