GL500 2 1DATALOGGERDataloggersand recorders with serial RS232 or USB connections FEATURES Rugged and easy to use USB or Serial communication ports available Records over 81 000 readings Battery powered for remote locations User friendly Windows and PDA software included Accepts any 4 20mA input To Order Call 1 800 876 1172 Datalogger Options Prices On this page Datalogger Product Description Datalogger Specifications Datalogger Software Information Downloads PDF Dataloggers Brochure Dataloggers Manual Datalogger PDA Software Manual DataloggerProduct DescriptionThe GL500 2 1 Dataloggeris the latest addition to Global Water s line of rugged remote dataloggers The dataloggers feature two analog channels and one digital channel forrecording data as well as monitoring battery voltage The dataloggerrecords over 81 000 readings and has four unique recording options fast 10samples per second programmable interval 1 second to multiple years logarithmic and exception Start and stop alarm times can be programmedto synchronize multiple dataloggers delay sampling until a preset time orlimit the number of recordings during a day The dataloggers are availablefor computers with either a RS 232 serial communications port GL500S 2 1version or a USB port GL500U 2 1 version Remote MonitoringThe GL500 2 1 dataloggers can monitor two 4 20mA sensors 0 5 volt inputs areavailable as a factory option and features a scalable digital input thataccepts switch closure signals from rain gauges or relays as well as pulsesfrom various external monitoring and control devices The dataloggerprovides switched power to the sensors based on the programmable sample intervaland sensor warm up time settings 2 wire and 3 wire sensors can be quicklyconnected to the datalogger s internal terminal strip and calibrated via theGlobal Logger software The GL500S 2 1 Datalogger Serial Communicationsversion can be accessed through dial out to a remote modem attached to theserial communication port SoftwareThe GL500 2 1 dataloggers include Global Logger II Windows software and PDAsoftware which allow for easy setup calibration upload and transfer to aspreadsheet program using a laptop desktop or PDA The Global Logger IIWindows software has online help files that are easily accessed using drop downmenus and links to quickly find the answers to your questions Please note The Global Logger PDA software included with the datalogger does not support the Palm operating system For more information onsupported PDAs click HERE Bluetooth CapabilityThe AK1500 Bluetooth Adaptor was designed to eliminate the need for custom PDAcables to communicate between your PDA and the GL500S 2 1 Dataloggers Theadaptor connects to the datalogger s serial port using the same interface cableprovided with the software cable kit The interface operates from a single9 volt battery and is turned on automatically when the cable connects thedatalogger and Bluetooth adapter Because the Bluetooth module consumespower when turned on it is recommended that the cable be disconnected from thedatalogger when not in use A red LED shows the power status and is oncontinuously while the adaptor is plugged into the datalogger There isalso a blue LED that shows the status of the Bluetooth connection DataloggersSpecificationsGlobal DataloggersMemory Non volatile flash memoryPower Voltage Two 9VDC alkaline batteries standard 8 VDCMin to 24 0 VDC Absolute Maximum Standby Current 65uA Typical Logging Current 5mA Typical sensor currentAnalog Sensor Inputs 4 20mA 0 5VDC as factory option Resolution 12 Bit 4096 Steps Channels 2 Input channels battery voltagemonitor Sensor Warm up Time Programmable 0 60 SecDigital Inputs Switch closure or pulse input Maximum Input Voltage 24VDC Maximum Frequency 100Hz Minimum Pulse Width 2mS Maximum Count 65 535 16 Bit Sample Modes Fixed Interval Programmable from 1 Sec to 1 Year High Speed 10 Samples per second Logarithmic Sample Rate Approximation Exception Log only on deviation from previous reading Storage Capacity 81 759 Recordings for all inputs plus time stampData Overwrite Select memory wrap or unwrap unwrap will stop loggingdata once memory is full Communication Ports GL500S 2 1 RS 232 4 pin circular connector GL500U 2 1 USB Type BSelectable Baud Rates 9600 19200 28800 38400 57600 115200Clock Synchronizes to the time and date of user s computerClock Accuracy 1 minute per monthOperating Temperature Industrial 40 to 185 F 40 to 85 C Battery may not apply Enclosure PVC 3x3x3 inch 7 6×7 6×7 6 cm Weight 0 5 lbs 227 g BluetoothFormat Bluetooth 2 0 SPP Serial Port Protocol Baud Rate Auto Detect up to 115K BaudPower 9 V Alkaline approx 20 hours continuous useCurrent 30mA AverageRange 20 Feet MaximumOperating Temp 40 to 185 F 40 to 85 C Compatible Software Global Logger II version 2 1 5 or higher Global Logger II PDA software version 2 0 1 FL16 Flow Monitor version 2 3 2Datalogger SoftwareCompatible with Microsoft s Windows 98 ME 2000 NT XP and VistaWindows and Excel are trademarks of the Microsoft CorporationTabular Display PrintoutData in standard spreadsheet format CSV Programmable alarm start and stop timesField calibration software and help files includedPDA software CE and Mobile compatible For more information onsupported PDAs click HERE Optional Weather Proof EnclosureExpanded UV protected PVC 9 x 7 5 x 4 5 Optional Battery Included with Weather Proof Enclosure 12 Volt 2 2 A hr Rechargeable Gell Cell Weight 3 5 lbs with data logger DataloggerSoftware InformationThe Datalogger includes Global Water Datalogger Software Windows basedsoftware that provides many useful features such as real time readout measurement interval and engineering unit selection station ID setting andsensor calibration The software makes accessing recorded data and settingoptions easy Data downloaded from the datalogger can easily be opened inany PC spreadsheet program for analysis and graphic presentation GloblalWater s Datalogger Software will run on a PC type laptop or desktop computerrunning Windows 98 or later To communicate with the Datalogger astandard RS232 serial cable for the GL500S 2 1or a USB Type B cable for theGL500U 2 1 is required Purchase of the datalogger includes theappropriate communication cable for communication between the datalogger andyour computer
Datalogger
$54.68
Datalogger
NORMAL DELIVERY 1-2 weekCall us to get the exact delivery date.
International Credit cards are not accepted on online orders.
Brand:Global Water
Warranty: As per Manufacturer policy
100% Genuine Product
Brand Warranty
Easy and Secure Payment
Timely delivery with complete tracking
Be the first to review “Datalogger”