PIE Model 532 High Accuracy mA & V Calibrator with Patented Current Leakage Test.
Includes rubber boot, carrying case and FREE NIST Traceable Certificate of Calibration
True ±0.012% of readingaccuracy
4 to 20 mA Loop Functions
Source and Read 0.000-24.000 mA Simulate 2-WireTransmitters
Power 2-Wire Transmitters and Read 0.000-24.000mA
Display current in mA or -25.00-125.00 % of 4-20 mA
Read & Source Voltage Function
Read 0.00 to ± 30.00 VDC with 4X over rangeability Source 0.000 to 24.000 VDC
with up to 20 mA output Direct Calibration1.000V to 5.000V
Full 5 Digit Display
Bar graph for quick reference of input andoutput levels
High contrast graphic display viewable in alllighting conditions and angles
Loop Diagnostic – PATENTEDFEATURE
Displays loop current, voltage, resistance, ACvoltage and
mode of operation simultaneously eliminatingmultiple DMM
connections.
Make DYNAMIC loop readings under actualoperating conditions
Included in the loop diagnostic features is itsability to measure ground current leakage from faulty
wiring, flooded conduit,and corrosion bridges. This leakage subtracts from the signal current sensed by
the receiving system (ie: DCS), causing a measurement error.
EZ-Dial™Knob
Change the speed of dialing your test point byjust pushing down on the knob
Easily adjust output by 0.001 mA (0.01 %) or0.100 mA (1.00 %)
EZ-Check™Switch with EZ-Step™Button
3 position tactile switch with push button fortrue one handed calibrations
Push button for stepping through calibrationpoints
16 different step sizes
Hands-free auto step and auto ramp modes
Selectable soak and step time for working withvalves
The Practical Instrument ElectronicsÂ’ Model 532 is the best tool for calibration, test, and diagnosing process loops.
The Model 532 brings all the features you would expect from a loop calibrator and timesaving new ones.
Make adjustments with the EZ-Dial™ Knob or test limits with the dual action EZ-Check™ Switch.
Powerful ramping functions are only a button away on the Model 532. Save potentially hours of troubleshooting
time on problem loops with the 532Â’s unique Loop Diagnostic Mode. In Loop Diagnostic Mode, the loop current,
voltage, resistances, AC voltage, and mode of operation are all displayed simultaneously; without the need of
multiple DMM connections. Loop diagnostic is available in every mode of operation and truly is a diagnostic monitor,
as parameters are continuously updated in real time. The smart diagnostic tool even indicates the most likely cause of loop failure!
The Model 532 can detect loop current, voltage, resistance,
AC voltage and HART®
protocol if present in the loop. You are able to connect the
532 to either side of the loop and in every operation mode
diagnose what is happening in the loop without the need of a
DMM. Just press the loop diagnostic button once
connected and see if there is a problem with the loop.
General Specifications:
(Unless otherwise indicated all specifications are rated from a nominal 23 °C, 70 % RH for 1 year from calibration)
Operating Temperature Range -20 to 60 °C (-5 to 140 °F) Storage Temperature Range -30 to 60 °C (-22 to 140 °F)
Relative Humidity Range 10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing
10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing Size 7.00 X 3.30 X 2.21 inches (177.8 x 83.8 x 56.1mm)
Weight 12.0 oz (340 grams)
Battery 9V AlkalineSource/Power and Measure 2-Wire Transmitter Specifications:
|
≥ 24 Volts |
|
1200 Ω at 20 mA for entire battery life, 950Ω w/HART® mode enabled |
|
Open loop or out of compliance conditions are indicated by appropriate error display Battery life in: Source mode ≥ 18 hrs at 12mA typical (HART® disabled) Power measure ≥ 10 hrs at 12mA typical HART® protocol mode is a selectable option at turn on. HART® protocol mode places a 250Ω resistor in series with the output Selectable EZ-Step(s) for Source Mode/2-Wire Transmitter Simulation: 2 to 16 selectable step settings
Selectable time settings for stepping and soak: STEP: 5 to 900 seconds SOAK: 0 to 900 seconds |
Be the first to review “mA & V Calibrator”